HXC-F Manual
HXC-F Manual
Operation Manual
V1.0-2013
I. Precautions Before Using The Scale
Environment
TABLE OF CONTENTS
The scale should always be used in an environment, which is free
I. Precautions Before Using The Scale---------------------1 from excessive air currents, corrosives, vibration, and temperature or
humidity extremes. These factors will affect displayed weight
II. Explanation Of Display Symbols-------------------------2
reading.
III. Keypad Functions----------------------------------------2
DO NOT install the scale :
IV. Operations------------------------------------------------4 z Next to open windows or doors causing drafts or rapid
Turn on Scale
Do not turn on scale with anything on the platform. The
switch is located on the right side of the scale. The scale will return to
zero for normal weighing. The scale is then ready for use. Give a
warm-up for 15~30 minutes before use is most suggested.
1
II. Explanation Of Display Symbols
: Use this key to accumulate weight value.
: Scale is in TARE mode.
: Press this key to clear the accumulated value.
: Scale is in stable mode.
: This key is for quantity warning function.
: Scale is in ZERO mode.
3
2
IV. Operations (IV) COUNTING
Push the ON/OFF switch to “ I “ position to turn on the scale & to A known unit weight can be directly input by giving the
At this moment, place objects in the container. The display will If the quantity of item put on the pan for sampling (sample size) is
show the net weight value. Remove both the container and
not enough, the indicator“◀”will be shown at the left side of to
objects, the display will show the gross weight (container + objects )
remind user to add more for sampling for getting accurate
accompanied by a negative sign.
quantity calculation.
2. If the container’s weight is known before, it is allowed to input the
(V) ACCUMULATION
value and press to subtract the container’s weight, and then
place objects with container on the pan. 1.Accumulate weight value
4
5
2.Accumulate quantity V.Calibration
a.Under counting mode, press to accumulate quantity.
b.The WEIGHT display will show total weight value, UNIT WEIGHT Switch on the scale and press for about 4 seconds.
display will show "Addxx" (0<xx<99), TOTAL COUNTS display will show
Press to bring the display to zero in case there is any zero
total quantity.
drifting while unloaded.
※ The value or quantity shown on the display will disappear in about 3
1. Single point calibration
seconds.
Place weights on the pan and input the weight value.
Press to clear accumulated value or quantity.
Calibration would be finished automatically when it is stable.
2. three points calibration
(VI) WARNING FUNCTION
1.Input quantity that needs warning while exceeding,and press . a.Press key.
2.The indicator“◀”will be shown at the left side of on screen. b.The TOTAL COUNTS will show the weight value (P1) that needs for
3.Under counting mode, if the quantity above preset value. calibration
Scale will beep. c.Place equivalent weights and wait for next step.
(For example, you input 100. When the quantity is more than 100pcs, d.When it shows P2, P3 value, repeat step b and c.
scale beeps )
4.Press to eliminate warning mode.
(VIII) BACKLIGHT
6 7