BDT13 – Differential type pressure gauge 100 & 160mm

Product description
Badotherm differential pressure gauge model BDT13 has a stainless
steel diaphragm and one pointer to read the differential pressure.
The variation in high static pressure makes this gauge suitable for
almost all differential measurements. This pressure gauge is typically
used for applications in the chemical, petro-chemical, oil & gas,
power and utilities, machine building and general process industries.

Design standard
DIN 16003

Dial sizes, ranges & accuracy


Possibilities in ranges and accuracies are led by the dial size.
Accuracy class is based on dry gauges. Liquid filling can affect the
accuracy. Compound and vacuum ranges are possible as well based
on the standard ranges
Process connection

Dial size Ranges Accuracy Threaded version


160mm 0…16 mbar to 0…60 mbar (flange 150mm) 1.6% Standard thread optional
100mm G½A G ½, M20x1.5
0…100 mbar to 0…25 bar (flange 100mm) 1.6%
160mm ½” NPT-m ½” NPT-f, R ½
¼ NPT – f ¼ NPT-m

Mounting variation Other thread standards such as ISO 7-1 R (BSPT), or DIN 13-1
All BDT13 gauges are bottom connection type A. (M20x1.5) can be selected as well.
• type A (10) bottom connection, direct mounting -> See datasheet “thread information" for specific thread details
• type C (13) bottom connection, surface mounting (back)
• type C2 (14) bottom connection, pipe mounting (back)

Materials of construction
BDT13
Case
AISI 304 (optionally 316)
Bezel
Connection1 AISI 316
Process cover flange AISI 316
Sensing element1 AISI 316
Movement Stainless steel
Pointer
Aluminium
Dial
Window gasket NBR
Fill plug NBR (HNBR for filled gauges)
Flange gasket1 FKM
Window Glass
*1 wetted materials

PG 7004
2nd of June 2020
Page11ofof8 8
Page
BDT13

Pressure limitations Degree of protection


The gauge are built to withstand harsh environments however the
The BDT13 has a standard degree of protection of IP65. The values
DIN 16003 limits the use of a pressure gauge according below table.
are determined according the IEC/EN 60529.
Dial size Steady Fluctuating Static pressure
100mm /160mm FSV 0.9 x FSV See overpressure table Add-on contacts
FSV: full scale value
The BDT13 can be equipped with an add-on contact mounted in a
Static pressure table
Optional
Makrolon hood. For low pressures <100 mbar inductive contacts are
range standard
16 mbar advised.
25 mbar
25 bar -
40 mbar Case filling
60 mbar Case filling for a BDT13 is only required to protect against corrosion
100 mbar
of the aluminium parts or fogging inside the case. Case filling for
160 mbar
250 mbar ranges <100 mbar is not possible. As there is no sensing element
400 mbar inside the case that needs dampening the use of case filling is not
600 mbar
required for that goal however the gauges can be filled with different
1.0 bar
1.6 bar 100 bar 200 bar kind of fill fluids. The fill fluids available are:
2.5 bar • BPF01 - Glycerine 86%
4.0 bar
• BPF02 - Silicon
6.0 bar
10 bar • BPF03 - Silicon for contacts
16 bar • BPF04 - Mineral oil (Foaming service)
25 bar
• BPF05 - Halocarbon (inert fluid for oxygen service)

Temperature limitations Special service


The gauges can be supplied cleaned for oxygen use. This means the
The gauges can withstand ambient and process temperature up to a
gauge is assembled and tested in a special area free of oil. The
certain limit. The limitations on temperature are:
Ambient Medium Storage gauges are individually packed in a plastic bag with marking. The
Dry case -20°C …+60°C -20°C…+200°C1 symbol used is:
-40…+70°C
Filled case -20°C …+60°C -20°C…+90°C
1: only with NBR gasket selection

The variation of indication from the reference temperature (20°C)


shall not exceed: ± 0.5% / 10K FSV Certification & Declaration
Calibration
Gauges are full range calibrated as a factory standard. Optionally
Window you can select a 5 points calibration certificate
Standard BDT13 gauges have a glass window. Optionally it can be ATEX 114 - 2014/68/EU
selected with laminated safety glass or plastic ATEX restrictions are explained in the IOM and in the ATEX
background datasheet.
Pointer
EN 10204 material certificate
Standard pointer is a slotted black painted aluminum pointer and
A material 3.1 certificate on the wetted parts can be supplied.
optionally with a micro adjustable pointer

Dial facing
The dial plate is made from aluminum and coated with UV resistant
white coating. The black dial markings, scale, numbering, and
interval is according the EN 837. Options like colored dial, customer
logo, or colored segments are possible as well. Scale interval and
numbering is following the EN837.

PG 7004
2nd of June 2020 Page 2 of 8
BDT13

Wetted part and diaphragm combinations


Retaining bolts & nuts
For specific use the BDT13 can be made in several material
The retaining bolts for the process cover flange depends on the static
combination. Basically the connection material, process cover, vent
pressure range. Up to 100 bar M12 bolts are use. 200 bar static
screw, and diaphragm are seen as wetted part metal parts. The
pressure is using M16 bolts. Most common materials are in the below
closing gasket can be selected separately matching the process
table.
Grade bolt Grade nut Material conditions. The most commonly used are marked with ◄ but all other
ISO 3506-1 A2-70 ISO 3506-2 A3 AISI 304 combination are possible as well.
ISO 3506-1 A4-80 ISO 3506-2 A4 AISI 316
ASTM A192 B8M ASTM A192 8M AISI 316
Flange + vent + Diaphragm material
ASTM A192 B7 ASTM A192 2H Carbon steel connection Material General name UNS Wst.
ASTM F468 F468W ASTM F468 F467W K500 AISI 316L S31603 1.4404
Super Duplex Super Duplex S32760 AISI 316(L) ◄
Alloy C276 N27600 2.4810
AISI 304L AISI 304L S30400 1.4306
Torque AISI 310 MoLn 25-22-2 LMN S31050 1.4466
AISI 316 UG AISI 316 UG S31600 1.4435
The closing between upper part and lower part is done with retaining AISI 321 AISI 321 S32100 1.4541
bolts. The torque of the M12 bolts is 55 Nm (40.5 ft-lb) and for the AISI 904(L) AISI 904L N08904 1.4539
M16 bolts is 90Nm (55.3 ft-lb) Alloy 20 Alloy 20 N08020 2.4660
Alloy 400◄ Alloy 400 N04400 2.4360
Alloy 600 Alloy 600 N06600 2.4816
Gaskets Alloy 625 Alloy 625 N06625 2.4856
For the BDT13 a gasket is supplied for the closing between the upper Alloy 825 Alloy 825 N08825 2.4858
Alloy B2 Alloy B2 N10665 2.4617
and the lower part. The standard flange gasket is FKM (Viton)
Alloy C-22 Alloy C-22 N06022 2.4602
material. Depending on the chemical compatibility the option of NBR Alloy C-276◄ Alloy C-276 N10276 2.4810
or EPDM Duplex F44 254 SMO (6Mo) S31254 1.4547
Duplex F51/F60◄ Duplex 2205 S32205 1.4462
Material Operating temperature Duplex F53 Super Duplex 2507 S32750 1.4410
FKM◄ -40 / +108°C Duplex F55 Super Duplex 2507 S32750 1.4410
NBR -25 / +204°C Nickel 201 Nickel 201 N02201 2.4068
EPDM -55 /+ 150°C Titanium Gr. 2 Titanium Gr. 1 R50250 2.7025
◄: Standard gasket Zirconium 702 Zirconium 702 R60702 -

Mounting manifold or diaphragm seals


The BDT13 is most commonly used in combination with a manifold
for easy testing and equalising. Advised valves for mounting to the
BDT13 is the BDTM932 or the BDTM953.

Diaphragm seals can be mounted as well to the BDT13 however only


a 81mm diaphragm is possible for the ranges ≥100 mbar and 89mm
diaphragm for ranges <100 mbar. Another aspect to keep in mind
that mounting effect of the diaphragm seals cannot be zero adjusted
on the BDT13. A levelled mounting (e.g. flow) is advised. Please
contact Badotherm Sales department for the correct combination.

PG 7004
2nd of June 2020 Page 3 of 8
BDT13

Dimensions table threaded

Type A (10)

Dial
type Range d L L1 L2 H H1 H2 E B weight filled
size
BDT13 (25 bar SP) 16…60mbar 160.0 160.0 202.0 52.0 150.0 236.0 150.0 11.2 kg 12.1 kg
100.0 110.0 150.0 50.0 100.0 73.6 6.4 kg 6.9 kg
BDT13 (100 bar SP)
160.0 160.0 152.0 52.0 65.0 7.2 kg 8.3 kg
≥100 mbar 100.0 186.0 100.0
100.0 110.0 150.0 50.0 9.6 kg 10.1 kg
BDT13 (200 bar SP) 140.0 113.6
160.0 160.0 152.0 52.0 10.4 kg 11.5 kg

Type C

PG 7004
2nd of June 2020 Page 4 of 8
BDT13

Type C2

type Range Dial size C1 C2 C3


BDT13 (25 bar SP) 16…60mbar 160.0 272.0 216.5 76.0
100.0 220.0 164.5
BDT13 (100 bar SP)
160.0 222.0 166.5
≥100 mbar 51.0
100.0 220.0 164.5
BDT13 (200 bar SP)
160.0 222.0 166.5

PG 7004
2nd of June 2020 Page 5 of 8
BDT13

Product code 100, 160mm


Code
Example code: BDT13 160 A G12M S303 S363 S304 A 0 G B36 16

BDT13◄
BDT13-02
T YPE
100 mm◄ 100
160 mm◄ 160
M OUNTING
Bottom connection - direct mounting (13) ◄ A
Bottom connection – wall mounting C
Bottom connection – pipe mounting C2
C ONNECTION
G1/2◄ G12M
1/2" NPT N12M
R 1/2 R12M
M20 x 1.5 M20M
1/4” NPT-f N14F
S ENSING ELEMENT
AISI 316◄ S363
Alloy 400 A400
Alloy C276 A276
Duplex 2205 2205
PROCESS FLANGES & CONNECTIONS
AISI 316(L)◄ S316
Alloy 400 A400
Alloy C276 A276
Duplex F51/F60 DF51
CASE /BEZEL MATERIAL
AISI 304◄ S304
AISI 316 S300
POINTER
Adjustable slotted pointer◄ A
Micro adjustable pointer M
Add-on contact device (see table 4) A__
L IQUID FILLING *1
Dry◄ 0
BPF 01 - Glycerine filled 1,23 (86%) 1
BPF 02 - Silicone filled 2
BPF 03 – Silicone Contact use 3
W INDOW
Glass◄ G
Laminated safety glass L
Acrylic (SAN) A
RANGE
See page table 1 and table 2 ….
A CCURACY
1,6*2 ◄ 16
◄: is the sign for the standard pressure gauge.
1: Not in combination with span <100 mbar
2: accuracy is without the addition of fill fluid or contact device.

PG 7004
2nd of June 2020 Page 6 of 8
BDT13

Tabel 1: Pressure Range code


bar mbar psi kPa kgf/cm2
Code Range Code Range Code Range Code Range Code Range
B31 0…0,6 M19◄ 0…16 P32 0…15 L31 0…60 K31 0…0,6
B35 0…1 M20◄ 0…25 P35 0…25 L35 0…100 K35 0…1
B36 0…1,6 M21◄ 0…40 P37 0…35 L36 0…160 K36 0…1,6
B38 0…2,5 M22◄ 0…60 P40 0…60 L38 0…250 K38 0…2,5
B40 0…4 M24 0…100 P43 0…100 L40 0…400 K40 0…4
B42 0…6 M25 0…160 P46 0…150 L42 0…600 K42 0…6
B45 0…10 M27 0…250 P48 0…250 L45 0…1000 K45 0…10
B50 0…16 M29 0…400 P51 0…350 K50 0…16
B54 0…25 M31 0…600 K54 0…25
M35 0…1000
◄ not possible with the BDT13-02

Table 2: Secondary scale Table 3: General option code


Dual scale option code Option (start options with X_) code
PSI red #PR Cleaned for Oxygen use _CFO
PSI black #PB NACE ISO 15156 (MR 01 75) _N75
PSI blue #PBL ATEX II 2G Ex h IIC _ATEX
bar red #BR 3.1 material certificate _IC31
bar black #BB Calibration certificate 5 points *1 _CC5
bar blue #BBL Adjusting key for contact _AKC
Add the code behind the pressure code Lead cable + Adjusting key for contact _LCK
(e.g. B45#PR for 0…10 bar//psi with red scale) 1: excluding contact device and case filling

Table 4: Contact option code Table 5: Gasket option code


Option code
Option (start options with X_) code
NBR NB
M1 (make contact) _AM1
EPDM EP
M2 (break contact) _AM2
Snap-action M11 (make - make contact) _AM11
magnetic contact* M12 (make - break contact) _AM12 Table 6: Bolting option code
M21 (break - make contact) _AM21 Option code
M22 (break – break contact _AM22 ISO 3506-1 A4-80 A480
I1 (make contact) _AI1 ASTM A192 B8M SB8M
I2 (break contact) _AI2 ASTM A192 B7 SB7
I11 (make - make contact) _AI11 ASTM F468 Alloy K500 B500
Inductive contact
I12 (make - break contact) _AI12 Super Duplex BSDX
I21 (break - make contact) _AI21
I22 (break – break contact) _AI22
<100 mbar only Inductive contact possible. Accuracy BDT13 is excluding contact
Contacts are without cable and adjusting key.

PG 7004
2nd of June 2020 Page 7 of 8
BDT13

Change log
Date Change
22-4-2020 Table header static pressure changed from “overpressure” to “static pressure”
2-6-2020 Coding tables adjusted with more options and removed ranges from ranges table
PG 7004
2nd of June 2020

Holland – Romania – India – Thailand – Dubai – USA

To our knowledge, the information contained herein is accurate as of the date of this document. However neither Badotherm, nor its affiliates makes
any warranty, express or limited, or accepts any liability in connection with this information or its use. This information is for technical skilled persons
at their own discretion and risk and does not relate to the use of this product in combination with any other product. The user alone finally determines
suitability of any information or material in contemplated use, the manner of use and whether any patents are infringed. This information gives typical
properties only. Badotherm reserves the right to make changes to the specifications any materials without prior notice. The latest version of the
datasheet can be found on www.badotherm.com.

© 2015 Badotherm, all rights reserved. Trademarks and/or other products referenced herein are either trademarks or registered trademarks of
Badotherm.

Page 8 of 8

You might also like