FX-Cube Hardware Manual Version : V1.
00
FX-Cube
CAR TOP INSPECTION BOARD
HARDWARE MANUAL
FX-Cube Hardware Manual Version: V1.00
Publisher Arkel Elektrik Elektronik San. ve Tic. A.Ş.
Eyüp Sultan Mah. Şah Cihan Cad. No:69
Sancaktepe/Istanbul 34885 TURKIYE
Tel: (+90 216) 540 03 10-11-12
Fax: (+90 216) 540 03 09
E-mail: [email protected]
www.arkel.com.tr
Date of issue 11.2019
Document version V1.00
This document has been created to be a guide for Arkel customers. Reproduction, transfer, distribution or storage of part or
all of the contents in this document in any form without the prior written permission of Arkel is prohibited. Arkel reserves
the right to make changes and improvements to any of the products described in this document without prior notice.
Arkel is not responsible for those mistakes that may be found in this manual and for the damages that they may cause.
FX-Cube Hardware Manual Version : V1.00
1. FX-Cube Overview
FX-Cube is a board that provides control of the inputs and outputs (Car calls, car fan, over load) in the elevator car by the
serial communication with the ARCUBE control panel. Serial communication saves many cables between the main control
board and the cabinet.
General
Dimensions
216 x 150 × 33 (All female terminals are plugged in)
Width × Length × Height (mm)
Operating Temperature 0 - 60 °C
Weight 465 gr.
Electrical Characteristic
Normally 24VDC (18-30VDC)
Supply voltage
Battery 12V 1.2Ah (Built-in battery charger)
1,44W (Stand-By)
Power consumption
10,8W (Max.) (All calls, outputs, battery charging are active.)
Gray/Inverted Max. current is 22mA at 24V
Gray/Binary/Inverted Binary
7Segment 30 mA output current per one-segment
Display outputs
(Short circuit protected)
31,32,02 (Normal and 30 mA output current (Short circuit
inverted) protected)
Programmable (3 pieces)
500,501 (Inspection operation
buttons)
LS(LiftSense)
817, 818 (Lower / Upper
forced deceleration magnetic Input current 6,2mA at 24VDC for one
Inputs switch) input
K20, DTS, FAN, FSL (Door
open-close buttons, fan sensor,
photocell sensor)
K16, K19 (Door open-close
limits)
804, 805 (Over load, full load)
Max switching voltage 250VAC/30VDC
3 programmable relays
Max switching current 3A
Outputs
Car light relay output 220VAC (3A fuse protected)
Car fan relay output
16 call button inputs and led Inputs active with 0Vdc (-),
Calls
outputs Led outputs short circuit protected
Emergency light output 12V (Max. 200mA)
Alarm button Active with 0Vdc (1000)
Gong output 8R/0.5W speaker
Buzzer output 8R/0.5W speaker
Continuous output with battery backup in
Magnetic switches supply output MLO (Max. 200mA)
case of power supply failure
AV-AR (0-10V)
Load cell connection
AI-AR (4-20 mA)
➢ Programmable inputs (804, 805, fan, photocell, ➢ 7Segment/ Gray/Inverted Gray/Binary/Inverted
etc.); 500,501 inputs; LiftSense input (LS) Binary indicator outputs
➢ Car fan, car light outputs ➢ Built-in battery charger
FX-Cube Hardware Manual Version: V1.00
➢ Alarm button input ➢ Car call button connection
➢ Emergency light output ➢ Programmable relay outputs (Door open, door close
➢ Gong output etc.)
➢ Buzzer output ➢ Load cell connection
➢ Magnetic switches supply output ➢ Announcement device used with external SD card
➢ Up/Down direction arrows and out of service ➢ Car-related safety circuit line
display outputs ➢ YH1, YH2, …. YH7 replacement terrminals
2. FX-Cube Technical Parameters
2.1 Display Outputs 2.3 Calls
It is possible to get the outputs for 7Segment, gray, binary FX-Cube has 16 calls button inputs (Active low) and led
from the indicator outputs. The connection diagrams of outputs. Led outputs are short-circuit protected.
gray, binary, common anode 7Segment indicators and
31-32-02 outputs are shown in the figure below.
2.4 Down-Up Direction Arrow and Out of
Service Outputs
The outputs are preferable as parametric selection of
2.2 Programmable Inputs and Programmable normal and invert switching. These outputs are over-
Relay Outputs current protected.
FX-Cube has 3 programmable relay outputs, 3
programmable inputs.
FX-Cube Hardware Manual Version : V1.00
2.5 Other Connections
Connection diagrams of inspection operation buttons (500,501), LiftSense input (LS), magnetic switches supply output
(MLO), alarm button (ALB), gong, call active (SPE) outputs, battery connection (Built-in battery charger), car light and
car fan are as follows.
*Volume level on SPE output can be adjusting via trimmer potentiometer.
*The battery connection must be done for alarm button, gong output and emergency light output to work properly.
3. FX-Cube Mechanical Dimensions