0% found this document useful (0 votes)
873 views6 pages

SR Vivodent S Pe - S DCL: Tooth Mould Chart

SR

Uploaded by

楊王向均
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
873 views6 pages

SR Vivodent S Pe - S DCL: Tooth Mould Chart

SR

Uploaded by

楊王向均
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

SR Vivodent  S PE | S DCL

The exceptionally esthetic tooth for sophisticated needs

Tooth mould chart


SR Vivodent® S PE
SR Orthotyp® S PE
SR Vivodent® S DCL
SR Orthotyp® S DCL
SMALL
SR Vivodent  S PE | SR Vivodent  S DCL
A22

A44

A11
9.6
9.7

9.3
7.9 7.7 7.9
41.6 41.3 41.8

A13
10.6

10.2
A42

42.6 8.0 42.8 8.4

10.2

10.5
9.7

A4

A5
A3

31.7 4.7 32.0 4.7 34.4 5.2

SR Orthotyp  S PE | SR Orthotyp  S DCL


29.5
9.9
N3U
N3L

9.0

31.9

MEDIUM
SR Vivodent  S PE | SR Vivodent  S DCL

A24B
A26

A54

11.0
10.8
11.4
47.0 8.8 47.0 8.8 8.4
43.9

A12
A25

11.5

10.1
46.0 8.9 44.1 8.6

A66

10.7
45.6 8.7

10.5
10.6
9.6

A7

A8
A6

35.0 5.2 35.9 5.4 38.4 5.6

SR Orthotyp  S PE | SR Orthotyp  S DCL


30.6 31.8
10.3 10.7
N4U

N5U
N4L

N5L

9.3 9.7
33.3 34.7


LARGE
SR Vivodent  S PE | SR Vivodent  S DCL
A27

A14

A17

12.7
11.8

11.5
9.0 9.7
48.7 45.9 8.9 51.0

A15
A68

11.7
10.5
48.8 9.0 48.8 9.1

11.8
12.5

A10
A9

36.8 5.6 38.6 5.7

SR Orthotyp  S PE | SR Orthotyp  S DCL


33.4
11.2
N6U
N6L

36.3 10.2

PROCESSING INSTRUCTIONS
Shades Posterior teeth
SR Vivodent® S DCL: This tooth mould chart facilitates the selection of posterior tooth sizes to match the selected anterior teeth.
– 16 A – D shades (A1, A2, A3, A3.5, A4, B1, B2, B3, B4, C1, C2, C3, C4, D2, D3, D4) Ivoclar Vivadent offers a variety of posterior teeth, which give the clinician the opportunity to select a tooth
– 4 Bleach shades (BL1, BL2, BL3, BL4) shape that will best meet the functional and esthetic needs of the patient.
SR Vivodent® S PE:
– 20 PE shades (01, 1A, 2A, 1C, 2B, 1D, 1E, 2C, 3A, 5B, 2E, 3E, 4A, 6B, 4B, 6C, 6D, 4C, 3C, 4D) Occlusal concept
SR Orthotyp S DCL and SR Orthotyp S PE are the classic choice for use in complete, partial, hybrid and implant-retained
dentures. The Orthotyp teeth are set up in accordance with a normal bite situation in a one-to-two-tooth relation. In this
Shade selection
way, the primary contacts in the centric position are located in the central fossae in the mandible as well as on the
The tooth shade is determined with the help of a shade guide according to the marginal ridges.
A– D or PE shade system of Ivoclar Vivadent.
The sample teeth of the SR Vivodent S DCL and SR Vivodent S PE shade guide
feature the same layering structure and material as the marketed original teeth.
Shade deviations will be consequently reduced to a minimum. The shade selection Classic occlusion One-to-two-tooth setup
with the patient should be carried out under defined light conditions
(5,500 K colour temperature) or during daylight (preferably light from the north).

Anterior Teeth
Anterior tooth selection

If possible, the anterior teeth should be selected directly with the patient according to anatomical and mimic characteristics.
The anterior teeth are categorized into triangular, oval and square shapes. However, it should be noted that each mould
Minimum layer thickness
has its own distinctive character.
It must be ensured that the stability of the teeth and the correct shade effect are maintained. It is therefore recommended
Triangular tooth moulds to observe the minimum layer thickness.
This group is characterized by teeth having a crown which tapers towards the cervical ridge. The vertical curvature is – Anterior teeth: min. 2.5 mm
moderate. – Posterior teeth: Central fossa min. 2.0 mm, cusp tips min. 2.5 mm, cervical area min. 2.5 mm
Oval tooth moulds To ensure that removable dentures remain functional over longer periods of time, the following prerequisites should be met:
The teeth of this category have a pronounced curvature. The labial curvature is particularly marked. – The dentures should be planned and fabricated in close cooperation with the dentist.
Square tooth moulds – Dentist and dental technician should ensure a balanced occlusion and articulation.
With this angular shape, the central incisor is dominant. The vertical labial curvature is moderate. – All dental products should be used according to the instructions of the manufacturer. Denture teeth, in particular, should
not be weakened by excess grinding.
Chairside – In order to ensure a reliable bond with the denture base material, the teeth are cleaned with steam, roughened and
The facial meter allows fast and targeted selection of the appropriate anterior tooth size. wetted with monomer. When completing the denture with an auto-curing polymer, we also recommend using
Step 1: Measure the interalar width of the nose with the facial meter and select the appropriate tooth size S/M/L. mechanical retentions.
Step 2: Select between triangular, oval and square tooth shapes within this size range. – The application of a glaze varnish or denture cleaning spray is not recommended.
– The teeth should not come into contact with a flame or direct heat.
The papillameter is the ideal device for the definition of the length of the upper lip and the lip closure line. – Heat development as a result of too much pressure during grinding must be prevented.
Especially for the length of the anterior teeth, the lip closure line provides one of the most important pieces of information. – We recommend wearing a face mask and using extraction equipment for protection against grinding dust.
– Cleaning is performed with commercial cleaning agents. Contact with solvents must be prevented.
Labside – If an allergy against components of the product is known, prefabricated teeth should not be used.
The following reference points are determined with the help of a model analysis: – When using C&B veneering materials, the corresponding Instructions for Use must be observed.
a) Position of the canines – We recommend wearing protective goggles to protect your eyes from grinding chips.
Identify the first large pair of palatine rugae; the midpoint of the labial surface of the upper canines is aligned at a
distance of approx. 9 mm.
b) Contact point of the central incisors
The labial surface of the central incisors is aligned at a distance of approx. 7 mm from the centre of the papilla
incisiva.
The length of the arch measured across these three points can be used as a reference to select a set of anterior teeth with
an appropriate width from the tooth mould chart.
COMBINATION TABLE

SR Vivodent® S PE | S DCL SR Orthotyp® S PE | S DCL (22°)


Anteriors Posteriors
Upper Lower Upper/Lower

A22 A3, A4, A5 N3U/N3L, N4U/N4L


A42 A3, A4, A5 N3U/N3L, N4U/N4L

SMALL A44 A3, A4, A5 N3U/N3L, N4U/N4L

A11 A3, A4, A5 N3U/N3L, N4U/N4L


A13 A3, A4, A5, A6 N3U/N3L, N4U/N4L

A25 A6, A7, A8 N4U/N4L, N5U/N5L


A26 A7, A8 N4U/N4L, N5U/N5L

A54 A7, A8 N4U/N4L, N5U/N5L


MEDIUM
A12 A6, A7, A8 N4U/N4L, N5U/N5L Ivoclar Vivadent Training Centre
A24B A6, A7, A8 N4U/N4L, N5U/N5L Always being on the latest standard of knowledge is a
A66 A6, A7, A8 N4U/N4L, N5U/N5L sign of your competence. Ivoclar Vivadent supports you
in achieving this goal by conveying to you both
A27 A9, A10 N5U/N5L, N6U/N6L knowledge about the latest products and know-how
A68 A9, A10 N5U/N5L, N6U/N6L with regard to practice-oriented application and
N5U/N5L, N6U/N6L working techniques. The Ivoclar Vivadent ICDE
LARGE A14 A8, A9
N5U/N5L, N6U/N6L continuously offers basic and advanced training courses
tailored to your needs.
A15 A10 N5U/N5L, N6U/N6L
A17 A9, A10 N5U/N5L, N6U/N6L
Have a look at our website.
This combination table is recommended as a guideline. In case of particular anatomical conditions, deviations are possible.

Ivoclar Vivadent AG
Bendererstr. 2
EN ISO 22112:2006 (D) 9494 Schaan
Descriptions and data constitute no warranty of Liechtenstein
attributes.
© Ivoclar Vivadent AG, Schaan/Liechtenstein Tel. +423 235 35 35
Date information prepared: 2017-02-07
Fax +423 235 33 60
688409/en www.ivoclarvivadent.com

You might also like