Installation NOTE: " Failure to observe this distance may result in wear on the
drive's internal and external gears or breakage of the rack with
engine starting."
1 - Observe if the gate is sliding freely in all its route, observing 7- Adjust the end magnets in open mode FA and closed FF,
support guide, rail, stops and pulleys placing a magnet on each end of the rack, observing the polarity of
2 - Provide a power and ground point, passing a conduit, each magnet between open and closed gate.
starting from the driver to the power board with a 10A bipolar NOTE: "The magnets must always be attached to the angle
circuit breaker. bracket, even during opening and closing adjustments to
NOTE: It is mandatory to install a shutdown device (bipolar prevent damage to the control unit"
circuit breaker with minimum contact opening equal to 3mm) 8 - Fix the control unit on the support guide inside the actuator
that must be incorporated into fixed wiring. (fixing instructions Page2).
3 - Provide the means by which you want to fix the drive. 9 - End of stroke HALL sensor The hall sensor identifies the
• Concrete Base • Metal Base • Cross Arm Brace (Air Base) Use polarity of the magnets, north and south. (instructions Page 6)
the measurements in the manual to mark the location of the NOTE: For bench tests, it should simulate the movement of
bolts. the magnet installed in the gate, remembering that when the
4- Place the washers on the base, screw the driver onto the control is activated the limit switch must be active.
washers and place the driver in the manual mode. In the installation and adjustment of the magnets, in the first
5 - Close the gate, support the rack on the gear and fix the bar two commands the control unit must recognize the FA and FF
in the gate with solder or screw, 30 by 30 cm. magnets.
6 - Once the racks have been fixed, remove the washers placed 10 - The use of the Active infrared sensor - SIA 30 is
on the base and fix the motor again, and check the spaces MANDATORY to activate the system of anti-locking protection,
between the rack and the gear. avoiding collision with obstacles, accidents with people or material
NOTE: " The washers placed at the beginning of the racks goods.
attachment serve to give the minimum mandatory height of 2 11 - The gates and actuators need periodic maintenance and
mm between the rack and the external gear of the engine." lubrication every 6 months for proper operation.
1
Support guide
Tx
Rail and Stopper
Pulleys
FF - End of stroke closed gate
FA -End of stroke open gate
2 3 4
Washers
Fixing
Hall magnet
FA - Open
FF - Closed t
h
Central fixing
central fitting
central fixing
central fixing Central fixed with screw
Measurements in
millimeters
Face of the
Gate
203mm
70mm
272mm
272mm
83mm
140mm
72 mm
58 mm
189.50mm
227mm 227mm
DZ3 TURBO / DZ4 TURBO Dz3 / DZ4 / DZ3 TURBO / DZ4 TURBO
Dz3 / DZ4
DZ4 BI TURBO DZ4 BI TURBO
Face of
the Gate
74
,
222 mm
192mm
151mm
83 mm
72 mm
227m
m
189.50mm
! ATTENTION !
Follow each one carefully:
1 - The installer must follow all instructions contained in this manual.
2 - Keep automatic equipment controls (control buttons, remote control etc.) out of reach of children. 3 - Perform control
operations from points where the automatic gate is visible.
4 - Use remote controls only if you can see the automatic gate.
5 - Warning: ROSSI assumes no liability for any damage caused by non-observance, at the time of installation, of safety regulations and laws
currently in force. NBR 5410:1997 - ABNT - Associação Brasileira de Normas Técnicas.
6 - This manual is intended exclusively for specialized personnel who are aware of the manufacturing criteria and the accident protection devices
related to motorized gates and doors.
7- If not provided for the switchboard, install beforehand a bipolar disconnect type switch with a minimum contact opening of 3mm,
of a mark which complies with international standards and provide for the equipment grounding.
8- For cables section, ROSSI recommends using a minimum section of 2.5mm and observing the laws in force in the country.
9- Keep this manual for future reference
10- This appliance is not intended for use by people (including children) with reduced physical, sensory or mental capacities, or people with
lack of experience and knowledge, unless they have received instructions regarding the use of the device or are under the supervision of a
person responsible for their safety.
11- It is recommended that children be supervised to ensure that they are not playing with the device. 12- The installer must provide all
information regarding automatic operation, emergency unlocking and deliver the user manual with the appropriate information.
13- It is mandatory to use the active infrared sensor - SIA 30 FS, to activate the anti-locking protection system and allow the FS control unit to
operate, avoiding collision with obstacles and accidents with people or material goods.
14- Before installing the unit, check that the driven part is in good mechanical condition, correctly balanced and opens and closes correctly
15- Check the installation frequently to detect imbalances and signs of wear or damage to cables, springs and assembly. Do not use in case
of repairs or if adjustment is required.
16- Disconnect the equipment from the power when cleaning or maintening.
17- Check if the temperature of the equipment is indicated and where it will be used.
Page 3
SIA30 FS Active Infrared Sensor
INSTALATION
- The gate barrier sensor SIA30 must be installed with a max. distance between the Transmitter and the Receiver.
- It must be at the same height and in the same alignment (when aligned the led indicator of the receiver goes out), ideal height for installation in gates is
50cm.Fig 01
- Installation should be done as close as possible to the gate.
NOTES ON INSTALLATION
• Do not set near plants and objects that could interrupt the beam of SIA30
• The transmitter and receiver can not be installed on mobile, unstable bases or in places that move easily.
• Always leave lenses clean
• Do not install the receiver with the lens facing the sun.
Rx Tx
Easy alignment drilling
measures
Max. 30m
R
0.50m
X
Tx
Page 4
User Manual
120°
Adjust Button
- Brake
- Soft stop
Hall-Sensor
Clutch Adjustment
Led - ST
Soft Stop – 1
Enable Lock - 2 Green Led - FA (End of Stroke Open)
Pause (automatic closing) - 3
Building / Residential - 4
Red Led - FF (End of Stroke Closed)
Jumper-
Note: For compatibility with previous
versions close Jumper
Features
- Automatic source 90V - 240V ~ ac - Receiving frequency 433 Mhz - Programmable soft stop - Traffic Light / garage light output
- Limit switch HALL sensor - Residential and building function - Switch - Photocell input
- Internal memory for 30 buttons - Adjustable automatic closing (Pause) - Adjustable electronic clutch - Exit lock (FHC)
- HCS reception system, anti-cloning - Soft start - Clears individual passkey codes
Page 5
05 - External button and traffic light / Light 06 - Antenna 07 - Record digital access key
16cm from core Mesh Delete individual buttons:
without mesh
Core
LED ST This feature allows you to erase from the
SIN -GND - Traffic light central memory the encoding,
consists of interconnecting a independently of the key code, without
signal with the central gate affecting others. For this the access key
must be in hand to perform this procedure.
Coaxial cable
16cm
1
2 2 – Lock 2 SIA 30 FS.
3 3 – Pause 3
4 4 - connect the
4 - Building
photocell's GND to
the TX-terminal of
• To enable, set the switch to ON position
the control unit
• 1 - Soft stop
Decrease gate speed shortly before reaching the end of stroke, with two levels of intensity, light or
heavy gate. Photocell FAIL SAFE TX- 12v GND 12v CM NF
to enable put DIP 1 to ON and press the SET button (6 times function.
- lightweight gate) or (7 times to return to the normal level). - Photocell must be switched on in Normally Closed (NF)
Note: Enabling DIP 1 is at normal intensity. Wiring diagram WITHOUT FS function
• 2 - Lock
The programming lock when enabled causes the control panel, after receiving an opening control, first NA CM GND 12V
send a pulse to open the lock and after a few seconds starts opening the gate. Note: Connection mode
• 3- Automatic closing (Pause);
Set the pause switch to ON position and give the opening command. When the open limit switch (FA) compatible with the
is reached, the ST LED will start flashing in 1-second intervals, allow the desired time to elapse for the previous switches or with
pause value and give the command again. Each flashing indicates 1 second elapsed until 12h (E.g. if the function Fail Safe
the LED blinks 20 times, the pause time will be 20 seconds. After this operation is completed, the DISABLED (central FS
pause will be programmed, every opening that occurs and elapses in the programmed time will connection with the jumper
automatically close the gate.)
To disable this feature, simply put the pause switch in the OFF position. In the next control the pause
closed).
will be disabled. (for this type of configuration, it is of utmost importance, for the safety of the user, to
use barrier sensors 'SIA 30'.)
• 4 - Building GND12v GND12v CM NA
Building - All controls open the gate, that only closes by automatic closing, which will only stop at the Note: For compatibility with previous versions, close the Jumper
open limit, if there is another control during the opening, central will ignore it. After the gate reaches (Input NA)
the open limit switch it will start the automatic closing time count, the gate will only close after the
scheduled time elapses. If there is a remote control or button control, the time will be reset and the
count will start again. If the gate is closing, any control will make the gate stop and open again. (Note:
In building mode the automatic closing is enabled automatically, just adjust the time in the 1st control.) - The gate barrier sensor must be installed with the Transmitter and Receiver.
Residential - Accepts all controls and pushbutton (1st - control opens, 2nd - to, 3rd – closes - Must be at the same height and in the same alignment, ideal height for installation in gates is 50cm.
- Installation should be done as close as possible to the gate.
- The certification is valid only with the use of approved ROSSI photocells: SIA 30 FS
10 - Clutch Adjustment 11 - Electronic Brake Adjustment
ADJUSTMENT - Adjustment of BRAKE levels
The control unit has 5 levels of electronic brake.
Clutch Adjustment Press and release the SET button at intervals of less than 1sec. according
• Adjust trimpot to minimum; to the desired level.
• Start the engine through the remote control; Level 1 = 25% of brake - Press 1 time
• Gradually increase the drive force until you Level 2 = 50% of brake - Press 2 times
move the gate; Level 3 = 75% of brake - Press 3 times
• adjust the trimpot slightly above that Level 4 = 100% brake - Press 4 times
Level 5 = Press 5 times
necessary to move the gate. NOTE: At the end of each setting, wait 2 seconds and the ST LED will
blink at which level it is programmed.
Page 6