0% found this document useful (0 votes)
186 views1 page

Metsec Framing Detail sf441 PDF

The document provides instructions for fixing a Metsec cripple stud extending from the lintel to the top of the jamb stud. Type G1 fixings should be located centrally in the vertical slot of the cripple stud's flanges at 300mm centres and at the head as per SF200 series details. Additional fixings may be required at the Metsec jamb studs according to project-specific designs.

Uploaded by

BanditAkos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
186 views1 page

Metsec Framing Detail sf441 PDF

The document provides instructions for fixing a Metsec cripple stud extending from the lintel to the top of the jamb stud. Type G1 fixings should be located centrally in the vertical slot of the cripple stud's flanges at 300mm centres and at the head as per SF200 series details. Additional fixings may be required at the Metsec jamb studs according to project-specific designs.

Uploaded by

BanditAkos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Fixing type G1 to each flange,

fix to jamb and cripple stud.


Metsec cripple stud Important
extending from lintel to top of Fixing to be located centrally in
jamb stud. Type G1 fixings the vertical slot, level with the
at 300mm centres fixing mark line

Fixings at head as SF200


series details. Extra fixings
Fixing type G1 required at Metsec jamb
to both flanges studs. Refer to project
specific design.

Single lintel shown but extended cripple


stud can be used with other lintel details

NOTES DRAWN DATE


THIS DRAWING IS A STANDARD DETAIL AND SHOULD BE READ IN
CONJUNCTION WITH METSEC PROJECT DRAWINGS OR INDICATIVES EL 26/05/09

CHECKED DATE

JBC 29/05/09

CLIENT PROJECT JOB No.

- - -
STATUS TITLE HIGH LOAD DETAIL - SINGLE JAMB: DWG No. REV
A MINOR CHANGES TO TEXT 14/02/12 JBC RMT
REF REVISION DATE BY CHK STANDARD DETAIL DEFLECTION HEAD - SLOTTED HEAD TRACK SF 441 A