LH 32 Mounting manual
Important safety and mounting EN Delivery includes
instructions A: 1 x brace for vertical inclination
B: 1 x brace for horizontal inclination
• Read and follow the safety and mounting instructions, keep these
C: 1 x adapter plate for wall installation
instructions easily accessible and always include them when pas-
D: 1 x T-nut, 2 x M6, 60 mm
sing the LH 32 on to third parties.
E: 2 x metal washers, M6
• Also read and follow the installation instructions contained in the
F: 1 x O-ring
operating manual of the studio monitor to be mounted.
G: 6 x Allen screws, M6x12
• When mounting, follow the local, national and international regu-
H: 2 x Allen screws, M8x12
lations and standards.
I: 1 x Allen key, 4 mm
J: 1 x Allen key, 5 mm
Intended use
The LH 32 is a holder for fastening a studio monitor to a wall and Specifications
providing optimal orientation. The LH 32 is only suitable for 2-way
Weight approx. 0.8 kg
studio monitors and must only be used indoors in clean, dry rooms
Dimensions when assembled 116 x 98 x 98 mm (H x W x D)
such as studios.
Max. load 10 kg
Additional mounting elements are needed to properly mount the
LH 32 and an attached studio monitor to the wall, which are not inclu-
ded with delivery. Warranty
The LH 32 must not be used for other purposes or in other environ- For the current terms and conditions of the warranty, please visit
ments. In case of any damage or any deviation from the safety and www.neumann.com.
mounting instructions, immediately dismount the studio monitor and
the LH 32.
Required qualifications
Only skilled personnel may attach the LH 32 to the studio monitor and
mount it on the wall. Due to his/her technical training, know-how and
experience as well as knowledge of relevant provisions, regulations
and standards, the specialist must be able to assess assigned tasks,
recognize potential hazards and ensure appropriate safety measures.
Safety instructions for mounting
• Mount only one LH 32 to one studio monitor, as described in these
assembly instructions.
• If the studio monitor is heavy, find a second person to help carry
out the work; during the work, place the studio monitor on a flat,
stable surface that can support its weight.
• Place something soft underneath the studio monitor so that you do
not scratch its surface while performing the work.
• Always use the enclosed original accessories.
• The wall must be able to support the weight of the studio monitor
and all accessories used, such that no parts will fall even if some-
one pulls hard on the power or audio cables. When calculating the
weight, also take into account the additional leverage.
• When mounting the LH 32 on the wall, use fastening elements (not
included with delivery) that are sufficiently dimensioned to ensure
that the entire weight is held securely.
• Mount the LH 32 and the attached studio monitor to a flat, non-slip
wall.
• Before starting work, prepare the adapter plate and fasten it to the
wall. Then attach the two braces for horizontal and vertical inclina-
tion adjustment to the adapter plate and hook the studio monitor
into the LH 32. Then adjust the studio monitor to the desired inc-
lination.
• Tighten all screws by hand. Once you have finished mounting and
aligning the studio monitor, ensure that all screws are firmly tigh-
tened.
• Take additional measures to ensure that the LH 32 and the attached
studio monitor cannot fall. Use safety wires that are sufficiently
dimensioned for the weight to be secured.
• Do not use the LH 32 in environments that are exposed to external
vibrations.
• Every 3 months, check that all screws are properly tightened and
that the LH 32, the studio monitor and the wall on which the LH 32
is mounted are in the proper condition.
• Replace the safety wire once it has already prevented the studio
monitor from falling once.
georg neumann gmbh · Leip ziger S tr . 112 · 10117 ber lin · germany 04/17 · 544944/A04
te l +49 (0)30 / 41 77 24-0 · fax -50 · [email protected] om · www.neumann.c om
LH 32 Mounting manual
1
A B
C
F
E F I
J
G H D
3–4 x
G
3–4 x
I
G
LH 32 Mounting manual
A
I
G
E
B
1
2
3 E
I G
4 0° – 25°
20° – 40°
> 40°
LH 32 Mounting manual
5
180°
6 7
G/H
3–4 x
I/J
M6: G, I
M8: H, J
LH 32 Mounting manual
1 2 33
1 = ≤ 10°
2 = ≤ 25°
3 = > 25°
1 = > 25°
2 = ≤ 25°
3 = ≤ 10°