CH 3 Ckto 1

This document contains configuration settings for a motor protection relay. It lists default parameters like message cycle time and temperature display unit. It also includes configuration of digital and analog inputs/outputs, protection elements, motor data, and RTD sensor settings. The status section provides recent motor operating conditions and the cause of the last trip event.

Uploaded by

Geraldine Ch
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
72 views36 pages

CH 3 Ckto 1

This document contains configuration settings for a motor protection relay. It lists default parameters like message cycle time and temperature display unit. It also includes configuration of digital and analog inputs/outputs, protection elements, motor data, and RTD sensor settings. The status section provides recent motor operating conditions and the cause of the last trip event.

Uploaded by

Geraldine Ch
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 36

CH 3 CKTO 1

PASSCODE
REFERENCE
Default Message Cycle Time 2.0 s
Default Message Timeout 300 s
Average Motor Load Calculation Period 15 min
Temperature Display Unit Celsius
Trace Memory Trigger Position 25%
Trace Memory Buffers 8 x 28 cycles
Display Update Interval 0.4 s
Motor Load Filter Interval 0 cycles

MESSAGE SCRATCHPAD
First Scratchpad Message Text 1 Text 1
Second Scratchpad Message Text 2
Third Scratchpad Message Text 3
Fourth Scratchpad Message Text 4
Fifth Scratchpad Message GE MULTILIN 469 Motor Relay
COMMUNICATION
Ethernet Subnet Mask 255.255.252. 0
DeviceNet MAC ID 63
DeviceNet Baud Rate 125 kbps
Front RS232 baud rate 19200 baud
Slave Address 2
Computer RS485 Baud Rate 19200 baud
Computer RS485 Parity None
Auxiliary RS485 Baud Rate 19200 baud
Auxiliary RS485 Parity None
SYSTEM SETUP
CURRENT SENSING
Phase CT Primary 100 A
Motor Full Load Amps 55 A
Ground CT Type 5 A Secondary
Ground CT Primary 50 A
Phase Differential CT Type None
VOLTAGE SENSING
VoltageTransformer Connection Type Open Delta
Voltage Transformer Ratio 35.00 :1
Motor Nameplate Voltage 4160 V
POWER SYSTEM
Nominal System Frequency 60 Hz
System Phase Sequence ABC
DIGITAL INPUTS
STARTER
Starter Status Switch Start Aux a
OUTPUT RELAYS
TRIP RELAY
Force R1 Operate Time 0s
ALARM RELAY
Force R4 Operate Time 0s
AUX RELAY 2
Force R2 Output Operate Time 0s
AUX RELAY 3
Force R3 Operate Time 0s
BLOCK START RELAY
Force R5 Operate Time 0s
PROTECTION
THERMAL MODEL
469 THERMAL MODEL
Curve Style Standard
Overload Pickup Level 1.15 FLA
Unbalance k Factor 3
Cool Time Constant Running 15 min
Cool Time Constant Stopped 30 min
Hot/Cold Safe Stall Ratio 1
Thermal Capacity Alarm Latched
Thermal Capacity Alarm Relays Alarm
Thermal Capacity Alarm Level 75 % used
Thermal Capacity Alarm Events On/Yes
Overload Trip Relays Trip
OVERLOAD CURVE
Standard Overload Curve Number 14
CURRENT ELEMENTS
SHORT CIRCUIT TRIP
Short Circuit Trip Latched
Overreach Filter On/Yes
Short Circuit Trip Relays Trip
Short Circuit Trip Pickup 6.0 CT
Intentional Short Circuit Trip Delay 50 ms
OVERLOAD ALARM
Overload Alarm Latched
Overload Alarm Relays Alarm
Overload Alarm Events On/Yes
Overload Alarm Delay 1.0 s
MECHANICAL JAM
Mechanical Jam Trip Latched
Mechanical Jam Trip Relays Trip
Mechanical Jam Pickup 3.00 xFLA
Mechanical Jam Delay 2s
UNDERCURRENT
Block Undercurrent from Start 0s
CURRENT UNBALANCE
Current Unbalance Alarm Unlatched
Current Unbalance Alarm Relays Alarm
Current Unbalance Alarm Pickup 15%
Current Unbalance Alarm Delay 10 s
Current Unbalance Alarm Events On/Yes
Current Unbalance Trip Latched
Current Unbalance Trip Relays Trip
Current Unbalance Trip Pickup 20%
Current Unbalance Trip Delay 5s
GROUND FAULT
Ground Fault Alarm Unlatched
Ground Fault Alarm Relays Alarm
Ground Fault Alarm Pickup 0.36 CT
Intentional GF Alarm Delay 0 ms
Ground Fault Alarm Events On/Yes
Ground Fault Trip Latched
Ground Fault Trip Relays Trip
Ground Fault Trip Pickup 0.36 CT
Intentional GF Trip Delay 110 ms
MOTOR STARTING
ACCELERATION TIMER
Accleration Timer Trip Latched
Acceleration Timer Trip Relays Trip
Acceleration Timer from Start 18.0 s
START INHIBIT
Start Inhibit Block On/Yes
Thermal Capacity Used Margin 25%

RESTART BLOCK
Restart Block On/Yes
Restart Block Time 15 s
RTD TEMPERATURE
RTD TYPES
Stator RTD Type 100 Ohm Platinum
Bearing RTD Type 100 Ohm Platinum
Ambient RTD Type 100 Ohm Platinum
Other RTD Type
RTD #1
RTD #1 Application Stator
RTD #1 Name
RTD #2
RTD #2 Application Stator
RTD #2 Name
RTD #3
RTD #3 Application Stator
RTD #3 Name
RTD #4
RTD #4 Application Stator
RTD #4 Name
RTD #5
RTD #5 Application Stator
RTD #5 Name
RTD #6
RTD #6 Application Stator
RTD #6 Name
RTD #7
RTD #7 Application Bearing
RTD #7 Name
RTD #8
RTD #8 Application Bearing
RTD #8 Name
RTD #9
RTD #9 Application Bearing
RTD #9 Name
RTD #10
RTD #10 Application Bearing
RTD #10 Name
RTD #11
RTD #11 Application Other
RTD #11 Name
RTD #12
RTD #12 Application Ambient
RTD #12 Name
VOLTAGE ELEMENTS
UNDERVOLTAGE
Undervoltage Alarm Unlatched
Undervoltage Alarm Relays Alarm
Undervoltage Alarm Pickup 0.90 Rated
Starting Undervoltage Alarm 0.85 Rated
Undervoltage Alarm Delay 10.0 s
Undervoltage Alarm Events On/Yes

OVERVOLTAGE
Overvoltage Alarm Unlatched
Overvoltage Relays Alarm
Overvoltage Alarm Pickup 1.05 Rated
Overvoltage Alarm Delay 10.0 s
Overvoltage Alarm Events On/Yes
Overvoltage Trip Latched
Overvoltage Trip Relays Trip
Overvoltage Trip Pickup 1.10 Rated
Overvoltage Trip Delay 3.0 s
PHASE REVERSAL
Voltage Phase Reversal Trip Latched
Voltage Phase Reversal Trip Relays Trip
POWER ELEMENTS
POWER FACTOR
Block Power Factor Element from Start 1s
REACTIVE POWER
Block kvar Element from Start 1s
UNDERPOWER
Block Underpower From Start 0s
REVERSE POWER
Block Reverse Power From Start 0s
TORQUE SETUP
Stator Resistance 0.004 mOhm
Pole Pairs 2
Torque Unit Newton-meter
OVERTORQUE SETUP
Overtorque Alarm Relays Alarm
Overtorque Alarm Level 4000.0 Nm
Overtorque Alarm Delay 1.0 s
CURRENT DEMAND
Current Demand Period 15 min
KW DEMAND
kW Demand Period 15 min
KVAR DEMAND
kvar Demand Period 15 min
KVA DEMAND
kVA Demand Period 15 min
ANALOG OUTPUTS
Analog Output 1 Selection None
Analog Output 2 Selection None
Analog Output 3 Selection None
Analog Output 4 Selection None
STATUS
MOTOR STATUS
Motor Status Running
Motor Load 0.43 FLA
Motor Thermal Capacity Used 0%
Estimated Time to Trip on Overload Never
Motor Speed Low Speed (Speed 1)
Phase A Current 47 A
Phase B Current 45 A
Phase C Current 41 A
Average Phase Current 49 A
Current Unbalance 3%
Vab 4026 V
Vbc 4011 V
Vca 4063 V
Average Line Voltage 4029 V
System Frequency 59.93 Hz
Power Factor 0.50 Lag
Real Power 147 kW
Real Power (HP) 327 hp
Reactive Power 264 kvar
Apparent Power 280 kVA
TRIP STATUS
Cause of Last Trip Acceleration Trip
Time of Last Trip 18:11:58
Date Of LastTrip 4/10/2020
Motor Speed During Trip Low Speed (Speed 1)
Pre-Trip Tachometer RPM 0 R.P.M
Phase A Pre-Trip Current 624 A
Phase B Pre-Trip Current 622 A
Phase C Pre-Trip Current 622 A
Pre-Trip Motor Load 5.87 FLA
Pre-Trip Current Unbalance 0%
Pre-Trip Ground Current 0.00 A
Phase A Pre-Trip Differential Current 0A
Phase B Pre-Trip Differential Current 0A
Phase C Pre-Trip Differential Current 0A
Pre-Trip Temperature of Hottest Stator RTD -----
Pre-Trip Temperature of Hottest Bearing RTD -----
Pre-Trip Temperature of Hottest Other RTD -----
Pre-Trip Ambient RTD Temperature -----
Pre-Trip Voltage Vab 3455 V
Pre-Trip Voltage Vbc 3440 V
Pre-Trip Voltage Vca 3467 V
Pre-Trip Voltage Van 0V
Pre-Trip Voltage Vbn 0V
Pre-Trip Voltage Vcn 0V
Pre-Trip System Frequency 60.02 Hz
Pre-Trip Real Power 736 kW
Pre-Trip Reactive Power 3645 kvar
Pre-Trip Apparent Power 3719 kVA
Pre-Trip Power Factor 0.20 Lag
Pre-Trip Temp. of Hottest Stator RTD (°F) -----
Pre-Trip Temp. of Hottest Bearing RTD (°F) -----
Pre-Trip Temp. of Hottest Other RTD (°F) -----
Pre-Trip Temp. of Hottest Ambient RTD (°F) -----
ALARM STATUS
Thermal Capacity Alarm Status Not Active
Overload Alarm Status Not Active
Current Unbalance Alarm Status Not Active
Ground Fault Alarm Status Not Active
Undervoltage Alarm Status Not Active
Overvoltage Alarm Status Not Active
Overload Lockout Block 0 min
Start Inhibit Block Lockout Time 0 min
Start/Hour Block Lockout Time 0 min
Time Between Starts Lockout Time 0 min
Restart Block Lockout 0s
INPUTS STATUS
Access Switch Status Open
Test Switch Status Open
Starter Switch Status Shorted
Emergency Restart Switch Status Open
Remote Reset Switch Status Open
Assignable Input 1 Status Open
Assignable Input 2 Status Open
Assignable Input 3 Status Open
Assignable Input 4 Status Open
Trip Coil Supervision No Coil
BLOCK STATUS
Overload Lockout Block 0 min
Start Inhibit Block Lockout Time 0 min
Start/Hour Block Lockout Time 0 min
Time Between Starts Lockout Time 0 min
Restart Block Lockout 0s
CLOCK STATUS
Date for Real Time Clock 5/10/2020
Time for Real Time Clock 10:55:08
SYSTEM STATUS
General Status Relay in Service Active
General Status Active Trip Condition Inactive
General Status Active Alarm Condition Inactive
General Status Motor Stopped Inactive
General Status Motor Starting Inactive
General Status Running Active
General Status Overload Pickup Inactive
General Status Unbalance Pickup Inactive
General Status Ground Pickup Inactive
General Status Hot RTD Inactive
General Status Loss of Load Inactive
Output Relay Status R1 Trip Inactive
Output Relay Status R2 Auxiliary Inactive
Output Relay Status R3 Auxiliary Inactive
Output Relay Status R4 Alarm Inactive
METERING DATA
CURRENT
Phase A Current 47 A
Phase B Current 45 A
Phase C Current 41 A
Average Phase Current 49 A
Motor Load 0.43 FLA
Current Unbalance 3%
U/B Biased Motor Load 0.38 FLA
Ground Current 0.00 A
RTD
RTD #1 Temperature No RTD
RTD #2 Temperature No RTD
RTD #3 Temperature No RTD
RTD #4 Temperature No RTD
RTD #5 Temperature No RTD
RTD #6 Temperature No RTD
RTD #7 Temperature No RTD
RTD #8 Temperature No RTD
RTD #9 Temperature No RTD
RTD #10 Temperature No RTD
RTD #11 Temperature No RTD
RTD #12 Temperature No RTD
Hottest Stator RTD No RTD
RTD #1 Application Stator
RTD #2 Application Stator
RTD #3 Application Stator
RTD #4 Application Stator
RTD #5 Application Stator
RTD #6 Application Stator
RTD #7 Application Bearing
RTD #8 Application Bearing
RTD #9 Application Bearing
RTD #10 Application Bearing
RTD #11 Application Other
RTD #12 Application Ambient
VOLTAGE
Vab 4026 V
Vbc 4011 V
Vca 4063 V
Average Line Voltage 4029 V
System Frequency 59.93 Hz
POWER
Power Factor 0.50 Lag
Real Powe 147 kW
Real Power (HP 327 hp
Reactive Power 264 kvar
Apparent Power 280 kVA
Positive watt Hours 6296.699 MWh
Positive var Hours 12062.313 Mvarh
Negative var Hours 0.000 Mvarh
DEMAND
Current Demand 45 A
Real Power Demand 147 kW
Reactive Power Demand 266 kvar
Apparent Power Demand 314 kVA
Peak Current Demand 79 A
Peak Real Power Demand 411 kW
Peak Reactive Power Demand 303 kvar
Peak Apparent Power Demand 515 kVA
PHASOR
VALUEV: Phase A Current 47 A 81 °
VALUEV: Phase B Current 45 A 196 °
VALUEV: Phase C Current 41 A 316 °
VALUEV: Vab 4.026 kV 0 °
VALUEV: Vbc 4011 V 299 °
VALUEV: Vca 4063 V 194 °
VALUEV: Van 0V0°
VALUEV: Vbn 0 V 194 °
VALUEV: Vcn 0 V 299 °
LEARNED DATA
MOTOR LEARNED DATA
Learned Acceleration Time 2.5 s
Learned Starting Current 645 A
Learned Starting Capacity 7%
Last Acceleration Time 2.5 s
Last Starting Current 634 A
Last Starting Capacity 7%
Average Motor Load Learned 0.41 FLA
RTD LEARNED DATA
RTD #1 Max. Temperature 250 °C
RTD #2 Max. Temperature 71 °C
RTD #3 Max. Temperature 71 °C
RTD #4 Max. Temperature 71 °C
RTD #5 Max. Temperature 71 °C
RTD #6 Max. Temperature 71 °C
RTD #7 Max. Temperature 71 °C
RTD #8 Max. Temperature 72 °C
RTD #9 Max. Temperature 72 °C
RTD #10 Max. Temperature 71 °C
RTD #11 Max. Temperature 71 °C
RTD #12 Max. Temperature 71 °C
MAINTENANCE
TRIP COUNTERS
Total Number of Trips 163
Overload Trips 11
Short Circuit Trips 30
Mechanical Jam Trips 7
Current Unbalance Trips 5
Ground Fault Trips 32

Motor Acceleration Trips 53


Undervoltage Trips 23
Overvoltage Trips 2

GENERAL COUNTERS
Number of Motor Starts 4303
Number of Emergency Restarts 8
Number of Starter Operations 4283
TIMERS
Motor Running Hours 45538 hr
Time Between Starts Timer 0 min
Start Timer 1 0 min
Start Timer 2 0 min
Start Timer 3 0 min
Start Timer 4 0 min
Start Timer 5 min
PRODUCT INFORMATION
SR469 MODEL INFO.
Order Code 469-P5-HI-A20-E
Serial Number B3083160
CALIBRATION INFO.
Original Calibration Date (Info) 08/14/2008
Last Calibration Date (info) 08/14/2008
PRODUCT ID
Product Hardware Revision I
Product Software Revision 00 00
Boot Program Revision 00 00
Boot Program Modification Number 00 00
CH 3 CKTO 2 CH2 CKTO 2
PASSCODE PASSCODE
PREFERENCES PREFERENCES
Default Message Cycle Time 2.0 s Default Message Cycle Time
Default Message Timeout 300 s Default Message Timeout
Average Motor Load Calculation Period15 min Average Motor Load Calculation Period
Temperature Display Unit Celsius Temperature Display Unit
Trace Memory Trigger Position 25% Trace Memory Trigger Position
Trace Memory Buffers 8 x 28 cycles Trace Memory Buffers
Display Update Interval 0.4 s Display Update Interval
Motor Load Filter Interval 0 cycles Motor Load Filter Interval

MESSAGE SCRATCHPAD MESSAGE SCRATCHPAD


First Scratchpad Message Text 1 Text 1 First Scratchpad Message Text 1
Second Scratchpad Message Text 2 Second Scratchpad Message Text 2
Third Scratchpad Message Text 3 Third Scratchpad Message Text 3
Fourth Scratchpad Message Text 4 Fourth Scratchpad Message Text 4
Fifth Scratchpad Message GE MULTILIN 469 Motor Relay Fifth Scratchpad Message GE MULTILIN 469 Motor Rel
COMMUNICATION COMMUNICATION
Ethernet Subnet Mask 255.255.252. 0 Ethernet Subnet Mask
DeviceNet MAC ID 63 DeviceNet MAC ID
DeviceNet Baud Rate 125 kbps DeviceNet Baud Rate
Front RS232 baud rate 19200 baud Front RS232 baud rate
Slave Address 2 Slave Address
Computer RS485 Baud Rate 9600 baud Computer RS485 Baud Rate
Computer RS485 Parity None Computer RS485 Parity
Auxiliary RS485 Baud Rate 9600 baud Auxiliary RS485 Baud Rate
Auxiliary RS485 Parity None Auxiliary RS485 Parity
SYSTEM SETUP SYSTEM SETUP
CURRENT SENSING CURRENT SENSING
Phase CT Primary 800 A Phase CT Primary
Motor Full Load Amps 106 A Motor Full Load Amps
Ground CT Type 5 A Secondary Ground CT Type
Ground CT Primary 50 A Ground CT Primary
Phase Differential CT Type None Phase Differential CT Type
VOLTAGE SENSING VOLTAGE SENSING
VoltageTransformer Connection Type Open Delta VoltageTransformer Connection Type
Voltage Transformer Ratio 35.00 :1 Voltage Transformer Ratio
Motor Nameplate Voltage 4160 V Motor Nameplate Voltage
POWER SYSTEM POWER SYSTEM
Nominal System Frequency 60 Hz Nominal System Frequency
System Phase Sequence ABC System Phase Sequence
PRESET MOTOR VALUES
Motor Running Hours 6051 hr
Positive watt Hours 854.496 MWh
Positive var Hours 1070.765 Mvarh
Negative var Hours 0.000 Mvarh
DIGITAL INPUTS DIGITAL INPUTS
STARTER STARTER
Starter Status Switch Start Aux a Start Aux a Starter Status Switch
OUTPUT RELAYS OUTPUT RELAYS
TRIP RELAY TRIP RELAY
Force R1 Operate Time 0s Force R1 Operate Time
ALARM RELAY ALARM RELAY
Force R4 Operate Time 0s Force R4 Operate Time
AUX RELAY 2 AUX RELAY 2
Force R2 Output Operate Time 0s Force R2 Output Operate Time
AUX RELAY 3 AUX RELAY 3
Force R3 Operate Time 0s Force R3 Operate Time
BLOCK START RELAY BLOCK START RELAY
Force R5 Operate Time 0s Force R5 Operate Time
PROTECTION PROTECTION
THERMAL MODEL THERMAL MODEL
469 THERMAL MODEL 469 THERMAL MODEL
Curve Style Standard Curve Style Standard
Overload Pickup Level 1.15 FLA Overload Pickup Level
Unbalance k Factor 3 Unbalance k Factor
Cool Time Constant Running 15 min Cool Time Constant Running
Cool Time Constant Stopped 30 min Cool Time Constant Stopped
Hot/Cold Safe Stall Ratio 1 Hot/Cold Safe Stall Ratio
Thermal Capacity Alarm Latched Thermal Capacity Alarm
Thermal Capacity Alarm Relays Alarm Thermal Capacity Alarm Relays
Thermal Capacity Alarm Level 75 % used Thermal Capacity Alarm Level
Thermal Capacity Alarm Events On/Yes Thermal Capacity Alarm Events
Overload Trip Relays Trip Trip Overload Trip Relays
OVERLOAD CURVE OVERLOAD CURVE
Standard Overload Curve Number 14 14 Standard Overload Curve Number
CURRENT ELEMENTS CURRENT ELEMENTS
SHORT CIRCUIT TRIP SHORT CIRCUIT TRIP
Short Circuit Trip Latched Latched Short Circuit Trip
Overreach Filter
Short Circuit Trip Relays Trip Trip Short Circuit Trip Relays
Short Circuit Trip Pickup 6.0 CT 6.0 CT Short Circuit Trip Pickup
Intentional Short Circuit Trip Delay 50 50 ms Intentional Short Circuit Trip Delay
OVERLOAD ALARM OVERLOAD ALARM
Overload Alarm Latched Latched Overload Alarm
Overload Alarm Relays Alarm Alarm Overload Alarm Relays
Overload Alarm Events On/Yes On/Yes Overload Alarm Events
Overload Alarm Delay 1.0 s 1.0 s Overload Alarm Delay
MECHANICAL JAM MECHANICAL JAM
Mechanical Jam Trip Latched Latched Mechanical Jam Trip
Mechanical Jam Trip Relays Trip Trip Mechanical Jam Trip Relays
Mechanical Jam Pickup 3.00 xFLA 3.00 xFLA Mechanical Jam Pickup
Mechanical Jam Delay 2 s 2s Mechanical Jam Delay
UNDERCURRENT UNDERCURRENT
Block Undercurrent from Start 0 s 0s Block Undercurrent from Start
CURRENT UNBALANCE CURRENT UNBALANCE
Current Unbalance Alarm Unlatched Unlatched Current Unbalance Alarm
Current Unbalance Alarm Relays Alarm Alarm Current Unbalance Alarm Relays
Current Unbalance Alarm Pickup 15 % 15% Current Unbalance Alarm Pickup
Current Unbalance Alarm Delay 10 s 10 s Current Unbalance Alarm Delay
Current Unbalance Alarm Events On/YeOn/Yes Current Unbalance Alarm Events
Current Unbalance Trip
Current Unbalance Trip Relays
Current Unbalance Trip Pickup
Current Unbalance Trip Delay
GROUND FAULT GROUND FAULT
Ground Fault Alarm Unlatched Unlatched Ground Fault Alarm
Ground Fault Alarm Relays Alarm Alarm Ground Fault Alarm Relays
Ground Fault Alarm Pickup 0.36 CT 0.36 CT Ground Fault Alarm Pickup
Intentional GF Alarm Delay 0 ms 0 ms Intentional GF Alarm Delay
Ground Fault Alarm Events On/Yes On/Yes Ground Fault Alarm Events
Ground Fault Trip Latched Latched Ground Fault Trip
Ground Fault Trip Relays Trip Trip Ground Fault Trip Relays
Ground Fault Trip Pickup 0.36 CT 0.36 CT Ground Fault Trip Pickup
Intentional GF Trip Delay 110 ms 110 ms Intentional GF Trip Delay
MOTOR STARTING MOTOR STARTING
ACCELERATION TIMER ACCELERATION TIMER
Accleration Timer Trip Latched Latched Accleration Timer Trip
Acceleration Timer Trip Relays Trip Trip Acceleration Timer Trip Relays
Acceleration Timer from Start 18.0 s 18.0 s Acceleration Timer from Start
START INHIBIT START INHIBIT
Start Inhibit Block On/Yes On/Yes Start Inhibit Block
Thermal Capacity Used Margin 25 % 25% Thermal Capacity Used Margin
JOGGING BLOCK (continued from last page)
Jogging Block On/Yes
Maximum Starts/Hour Permissible 4
Time Between Starts 0 min
RESTART BLOCK RESTART BLOCK
Restart Block On/Yes On/Yes Restart Block On/Yes
Restart Block Time 15 s 15 s Restart Block Time 10 s
RTD TEMPERATURE RTD TEMPERATURE
RTD TYPES RTD TYPES
Stator RTD Type 100 Ohm Platinum Stator RTD Type
Bearing RTD Type 100 Ohm Platinum Bearing RTD Type
Ambient RTD Type 100 Ohm Platinum Ambient RTD Type
Other RTD Type 100 Ohm Platinum Other RTD Type
RTD #1 RTD #1
RTD #1 Application Stator RTD #1 Application None
RTD #1 Name
RTD #2 RTD #2
RTD #2 Application Stator RTD #2 Application None
RTD #2 Name
RTD #3 RTD #3
RTD #3 Application Stator RTD #3 Application None
RTD #3 Name
RTD #4 RTD #4
RTD #4 Application Stator RTD #4 Application None
RTD #4 Name
RTD #5 RTD #5
RTD #5 Application Stator RTD #5 Application None
RTD #5 Name
RTD #6 RTD #6
RTD #6 Application Stator RTD #6 Application None
RTD #6 Name
RTD #7 RTD #7
RTD #7 Application Bearing RTD #7 Application None
RTD #7 Name
RTD #8 RTD #8
RTD #8 Application Bearing RTD #8 Application None
RTD #8 Name
RTD #9 RTD #9
RTD #9 Application Bearing RTD #9 Application None
RTD #9 Name
RTD #10 RTD #10
RTD #10 Application Bearing RTD #10 Application None
RTD #10 Name
RTD #11 RTD #11
RTD #11 Application Other RTD #11 Application None
RTD #11 Name
RTD #12 RTD #12
RTD #12 Application Ambient RTD #12 Application
RTD #12 Name
VOLTAGE ELEMENTS VOLTAGE ELEMENTS
UNDERVOLTAGE UNDERVOLTAGE
Undervoltage Active Only If Bus Energi On/Yes
Undervoltage Alarm Unlatched Unlatched Undervoltage Alarm
Undervoltage Alarm Relays Alarm Alarm Undervoltage Alarm Relays
Undervoltage Alarm Pickup 0.90 Rated 0.90 Rated Undervoltage Alarm Pickup
Starting Undervoltage Alarm Pickup 0.8 0.85 Rated Starting Undervoltage Alarm
Undervoltage Alarm Delay 10.0 s 10.0 s Undervoltage Alarm Delay
Undervoltage Alarm Events On/Yes On/Yes Undervoltage Alarm Events
OVERVOLTAGE OVERVOLTAGE
Overvoltage Alarm Unlatched Unlatched Overvoltage Alarm
Overvoltage Relays Alarm Alarm Overvoltage Relays
Overvoltage Alarm Pickup 1.05 Rated 1.05 Rated Overvoltage Alarm Pickup
Overvoltage Alarm Delay 10.0 s 10.0 s Overvoltage Alarm Delay
Overvoltage Alarm Events On/Yes On/Yes Overvoltage Alarm Events
Overvoltage Trip Latched Latched Overvoltage Trip
Overvoltage Trip Relays Trip Trip Overvoltage Trip Relays
Overvoltage Trip Pickup 1.10 Rated 1.10 Rated Overvoltage Trip Pickup
Overvoltage Trip Delay 3.0 s 3.0 s Overvoltage Trip Delay
PHASE REVERSAL PHASE REVERSAL
Voltage Phase Reversal Trip Latched Latched Voltage Phase Reversal Trip
Voltage Phase Reversal Trip Relays Trip Trip Voltage Phase Reversal Trip Relays
POWER ELEMENTS POWER ELEMENTS
POWER FACTOR POWER FACTOR
Block Power Factor Element from Start 1 s Block Power Factor Element from Start
REACTIVE POWER REACTIVE POWER
Block kvar Element from Start 1 s 1s Block kvar Element from Start
UNDERPOWER UNDERPOWER
Block Underpower From Start 0 s 0s Block Underpower From Start
REVERSE POWER REVERSE POWER
Block Reverse Power From Start 0 s 0s Block Reverse Power From Start
TORQUE SETUP TORQUE SETUP
Stator Resistance 0.004 mOhm 0.004 mOhm Stator Resistance
Pole Pairs 2 2 Pole Pairs
Torque Unit Newton-meter Torque Unit Torque Unit
OVERTORQUE SETUP OVERTORQUE SETUP
Overtorque Alarm Relays Alarm Alarm Overtorque Alarm Relays
Overtorque Alarm Level 4000.0 Nm 4000.0 Nm Overtorque Alarm Level
Overtorque Alarm Delay 1.0 s 1.0 s Overtorque Alarm Delay
CURRENT DEMAND CURRENT DEMAND
Current Demand Period 15 min 15 min Current Demand Period
KW DEMAND KW DEMAND
kW Demand Period 15 min 15 min kW Demand Period
KVAR DEMAND KVAR DEMAND
kvar Demand Period 15 min 15 min kvar Demand Period
KVA DEMAND KVA DEMAND
kVA Demand Period 15 min 15 min kVA Demand Period
ANALOG OUTPUTS ANALOG OUTPUTS
Analog Output 1 Selection None None Analog Output 1 Selection
Analog Output 2 Selection None None Analog Output 2 Selection
Analog Output 3 Selection None None Analog Output 3 Selection
Analog Output 4 Selection None None Analog Output 4 Selection
STATUS STATUS
MOTOR STATUS MOTOR STATUS
Motor Status Stopped Stopped Motor Status
Motor Load 0.00 FLA 0.00 FLA Motor Load
Motor Thermal Capacity Used 0 % 0% Motor Thermal Capacity Used
Estimated Time to Trip on Overload Ne Never Estimated Time to Trip on Overload
Motor Speed Low Speed (Speed 1) Low Speed (Speed 1) Motor Speed
Phase A Current 0 A 0A Phase A Current
Phase B Current 0 A 0A Phase B Current
Phase C Current 0 A 0A Phase C Current
Average Phase Current 0 A 0A Average Phase Current
Current Unbalance 0 % 0% Current Unbalance
Vab 4033 V 4033 V Vab
Vbc 4035 V 4035 V Vbc
Vca 4058 V 4058 V Vca
Average Line Voltage 4039 V 4039 V Average Line Voltage
System Frequency 59.96 Hz 59.96 Hz System Frequency
Power Factor 1.00 Lag 1.00 Lag Power Factor
Real Power 0 kW 0 kW Real Power
Real Power (HP) 0 hp 0 hp Real Power (HP)
Reactive Power 0 kvar 0 kvar Reactive Power
Apparent Power 0 kVA 0 kVA Apparent Power
TRIP STATUS TRIP STATUS
Cause of Last Trip Acceleration Trip Acceleration Trip Cause of Last Trip
Time of Last Trip 16:19:29 16:19:29 Time of Last Trip
Date Of LastTrip 07/9/2020 9/7/2020 Date Of LastTrip
Motor Speed During Trip Low Speed (SpLow Speed (Speed 1) Motor Speed During Trip
Pre-Trip Tachometer RPM 0 R.P.M 0 R.P.M Pre-Trip Tachometer RPM
Phase A Pre-Trip Current 555 A 555 A Phase A Pre-Trip Current
Phase B Pre-Trip Current 555 A 555 A Phase B Pre-Trip Current
Phase C Pre-Trip Current 556 A 556 A Phase C Pre-Trip Current
Pre-Trip Motor Load 5.23 FLA 5.23 FLA Pre-Trip Motor Load
Pre-Trip Current Unbalance 0 % 0% Pre-Trip Current Unbalance
Pre-Trip Ground Current 0.00 A 0.00 A Pre-Trip Ground Current
Phase A Pre-Trip Differential Current 0 0 A Phase A Pre-Trip Differential Current
Phase B Pre-Trip Differential Current 0 12:00 AM Phase B Pre-Trip Differential Current
Phase C Pre-Trip Differential Current 0 0 A Phase C Pre-Trip Differential Current
Pre-Trip Temperature of Hottest Stator ----- Pre-Trip Temperature of Hottest Stator R
Pre-Trip Temperature of Hottest Beari ----- Pre-Trip Temperature of Hottest Bearing
Pre-Trip Temperature of Hottest Other ----- Pre-Trip Temperature of Hottest Other R
Pre-Trip Ambient RTD Temperature ----- Pre-Trip Ambient RTD Temperature
Pre-Trip Voltage Vab 3462 V 3462 V Pre-Trip Voltage Vab
Pre-Trip Voltage Vbc 3474 V 3474 V Pre-Trip Voltage Vbc
Pre-Trip Voltage Vca 3497 V 3497 V Pre-Trip Voltage Vca
Pre-Trip Voltage Van 0 V 0V Pre-Trip Voltage Van
Pre-Trip Voltage Vbn 0 V 0V Pre-Trip Voltage Vbn
Pre-Trip Voltage Vcn 0 V 0V Pre-Trip Voltage Vcn
Pre-Trip System Frequency 60.02 Hz 60.02 Hz Pre-Trip System Frequency
Pre-Trip Real Power 604 kW 604 kW Pre-Trip Real Power
Pre-Trip Reactive Power 3279 kvar 3279 kvar Pre-Trip Reactive Power
Pre-Trip Apparent Power 3335 kVA 3335 kVA Pre-Trip Apparent Power
Pre-Trip Power Factor 0.18 Lag 0.18 Lag Pre-Trip Power Factor
Pre-Trip Temp. of Hottest Stator RTD (° ----- Pre-Trip Temp. of Hottest Stator RTD (°F)
Pre-Trip Temp. of Hottest Bearing RTD ( ----- Pre-Trip Temp. of Hottest Bearing RTD (°F
Pre-Trip Temp. of Hottest Other RTD (°F ----- Pre-Trip Temp. of Hottest Other RTD (°F)
Pre-Trip Temp. of Hottest Ambient RTD ----- Pre-Trip Temp. of Hottest Ambient RTD (°
ALARM STATUS ALARM STATUS
Thermal Capacity Alarm Status Not Acti Not Active Thermal Capacity Alarm Status Not Active
Overload Alarm Status Not Active Not Active Overload Alarm Status Not Active
Current Unbalance Alarm Status Not Ac Not Active Current Unbalance Alarm Status Not Acti
Ground Fault Alarm Status Not Active Not Active Ground Fault Alarm Status Not Active
Undervoltage Alarm Status Not Active Not Active Undervoltage Alarm Status Not Active
Overvoltage Alarm Status Not Active Not Active Overvoltage Alarm Status Not Active
Overload Lockout Block 0 min 0 min Overload Lockout Block
Start Inhibit Block Lockout Time 0 min 0 min Start Inhibit Block Lockout Time
Start/Hour Block Lockout Time 0 min 0 min Start/Hour Block Lockout Time
Time Between Starts Lockout Time 0 m 0 min Time Between Starts Lockout Time
Restart Block Lockout 0 s 0s Restart Block Lockout
INPUTS STATUS INPUTS STATUS
Access Switch Status Open Open Access Switch Status
Test Switch Status Open Open Test Switch Status
Starter Switch Status Open Open Starter Switch Status
Emergency Restart Switch Status Open Open Emergency Restart Switch Status
Remote Reset Switch Status Open Open Remote Reset Switch Status
Assignable Input 1 Status Open Open Assignable Input 1 Status
Assignable Input 2 Status Open Open Assignable Input 2 Status
Assignable Input 3 Status Open Open Assignable Input 3 Status
Assignable Input 4 Status Open Open Assignable Input 4 Status
Trip Coil Supervision No Coil No Coil Trip Coil Supervision
BLOCK STATUS BLOCK STATUS
Overload Lockout Block 0 min 0 min Overload Lockout Block
Start Inhibit Block Lockout Time 0 min 0 min Start Inhibit Block Lockout Time
Start/Hour Block Lockout Time 0 min 0 min Start/Hour Block Lockout Time
Time Between Starts Lockout Time 0 m 0 min Time Between Starts Lockout Time
Restart Block Lockout 0 s 0s Restart Block Lockout
CLOCK STATUS CLOCK STATUS
Date for Real Time Clock 10/6/2020 6/10/2020 Date for Real Time Clock
Time for Real Time Clock 10:59:08 10:59:08 Time for Real Time Clock
SYSTEM STATUS SYSTEM STATUS
General Status Relay in Service Active Active General Status Relay in Service
General Status Active Trip Condition InaInactive General Status Active Trip Condition
General Status Active Alarm Condition IInactive General Status Active Alarm Condition
General Status Motor Stopped Active Active General Status Motor Stopped
General Status Motor Starting Inactive Inactive General Status Motor Starting
General Status Running Inactive Inactive General Status Running
General Status Overload Pickup Inactiv Inactive General Status Overload Pickup
General Status Unbalance Pickup InactiInactive General Status Unbalance Pickup
General Status Ground Pickup Inactive Inactive General Status Ground Pickup
General Status Hot RTD Inactive Inactive General Status Hot RTD
General Status Loss of Load Inactive Inactive General Status Loss of Load
Output Relay Status R1 Trip Inactive Inactive Output Relay Status R1 Trip
Output Relay Status R2 Auxiliary InactivInactive Output Relay Status R2 Auxiliary
Output Relay Status R3 Auxiliary InactivInactive Output Relay Status R3 Auxiliary
Output Relay Status R4 Alarm Inactive Inactive Output Relay Status R4 Alarm
METERING DATA METERING DATA
CURRENT CURRENT
Phase A Current 0 A 0A Phase A Current 0 A
Phase B Current 0 A 0A Phase B Current 0 A
Phase C Current 0 A 0A Phase C Current 0 A
Average Phase Current 0 A 0A Average Phase Current 0 A
Motor Load 0.00 FLA 0.00 FLA Motor Load 0.00 FLA
Current Unbalance 0 % 0% Current Unbalance 0 %
U/B Biased Motor Load 0.00 FLA 0.00 FLA U/B Biased Motor Load 0.00 FLA
Ground Current 0.00 A 0.00 A Ground Current 0.00 A
RTD RTD
RTD #1 Temperature No RTD No RTD RTD #1 Temperature
RTD #2 Temperature No RTD No RTD RTD #2 Temperature
RTD #3 Temperature No RTD No RTD RTD #3 Temperature
RTD #4 Temperature No RTD No RTD RTD #4 Temperature
RTD #5 Temperature No RTD No RTD RTD #5 Temperature
RTD #6 Temperature No RTD No RTD RTD #6 Temperature
RTD #7 Temperature No RTD No RTD RTD #7 Temperature
RTD #8 Temperature No RTD No RTD RTD #8 Temperature
RTD #9 Temperature No RTD No RTD RTD #9 Temperature
RTD #10 Temperature No RTD No RTD RTD #10 Temperature
RTD #11 Temperature No RTD No RTD RTD #11 Temperature
RTD #12 Temperature No RTD No RTD RTD #12 Temperature
Hottest Stator RTD No RTD No RTD Hottest Stator RTD
RTD #1 Application Stator Stator RTD #1 Application
RTD #2 Application Stator Stator RTD #2 Application
RTD #3 Application Stator Stator RTD #3 Application
RTD #4 Application Stator Stator RTD #4 Application
RTD #5 Application Stator Stator RTD #5 Application
RTD #6 Application Stator Stator RTD #6 Application
RTD #7 Application Bearing Bearing RTD #7 Application
RTD #8 Application Bearing Bearing RTD #8 Application
RTD #9 Application Bearing Bearing RTD #9 Application
RTD #10 Application Bearing Bearing RTD #10 Application
RTD #11 Application Other Other RTD #11 Application
RTD #12 Application Ambient Ambient RTD #12 Application
VOLTAGE VOLTAGE
Vab 4033 V 4033 V Vab
Vbc 4035 V 4035 V Vbc
Vca 4058 V 4058 V Vca
Average Line Voltage 4039 V 4039 V Average Line Voltage 4110 V
System Frequency 59.96 Hz 59.96 Hz System Frequency 60.00 Hz
POWER POWER
Power Factor 1.00 1 Power Factor 1.00
Real Power 0 kW 0 kW Real Power 0 kW
Real Power (HP) 0 hp 0 hp Real Power (HP) 0 hp
Reactive Power 0 kvar 0 kvar Reactive Power 0 kvar
Apparent Power 0 kVA 0 kVA Apparent Power 0 kVA
Positive watt Hours 854.496 MWh 854.496 MWh Positive watt Hours 3695.260 MWh
Positive var Hours 1070.765 Mvarh 1070.765 Mvarh Positive var Hours 8556.681 Mvarh
Negative var Hours 0.000 Mvarh 0.000 Mvarh Negative var Hours 0.000 Mvarh
DEMAND DEMAND
Current Demand 3 A 3A Current Demand 14 A
Real Power Demand 8 kW 8 kW Real Power Demand 25 kW
Reactive Power Demand 15 kvar 15 kvar Reactive Power Demand 97 kvar
Apparent Power Demand 18 kVA 18 kVA Apparent Power Demand 102 kVA
Peak Current Demand 85 A 85 A Peak Current Demand 32 A
Peak Real Power Demand 367 kW 367 kW Peak Real Power Demand 126 kW
Peak Reactive Power Demand 328 kvar328 kvar Peak Reactive Power Demand 172 kvar
Peak Apparent Power Demand 559 kVA559 kVA Peak Apparent Power Demand 218 kVA
PHASOR PHASOR
VALUERS: Phase A Current 0 A 103 ° 0 A 103 ° VALUEar: Phase A Current 0 A 216 °
VALUERS: Phase B Current 0 A 103 ° 0 A 103 ° VALUEar: Phase B Current 0 A 126 °
VALUERS: Phase C Current 0 A 103 ° 0 A 103 ° VALUEar: Phase C Current 0 A 306 °
VALUERS: Vab 4.033 kV 0 ° 4.033 kV 0 ° VALUEar: Vab 4.126 kV 0 °
VALUERS: Vbc 4035 V 300 ° 4035 V 300 ° VALUEar: Vbc 4075 V 298 °
VALUERS: Vca 4058 V 103 ° 4058 V 103 ° VALUEar: Vca 4146 V 127 °
VALUERS: Van 0 V 0 ° 0V0° VALUEar: Van 0 V 0 °
VALUERS: Vbn 0 V 103 ° 0 V 103 ° VALUEar: Vbn 0 V 127 °
VALUERS: Vcn 0 V 300 ° 0 V 300 ° VALUEar: Vcn 0 V 298 °
LEARNED DATA LEARNED DATA
MOTOR LEARNED DATA MOTOR LEARNED DATA
Learned Acceleration Time 3.5 s 3.5 s Learned Acceleration Time 2.3 s
Learned Starting Current 576 A 576 A Learned Starting Current 388 A
Learned Starting Capacity 8 % 8% Learned Starting Capacity 9 %
Last Acceleration Time 3.3 s 3.3 s Last Acceleration Time 1.8 s
Last Starting Current 567 A 567 A Last Starting Current 380 A
Last Starting Capacity 8 % 8% Last Starting Capacity 7 %
Average Motor Load Learned 0.02 FLA 0.02 FLA Average Motor Load Learned 0.22 FLA
RTD LEARNED DATA RTD LEARNED DATA
RTD #1 Max. Temperature 40 °C 40 °C RTD #1 Max. Temperature
RTD #2 Max. Temperature 40 °C 40 °C RTD #2 Max. Temperature
RTD #3 Max. Temperature 40 °C 40 °C RTD #3 Max. Temperature
RTD #4 Max. Temperature 40 °C 40 °C RTD #4 Max. Temperature
RTD #5 Max. Temperature 40 °C 40 °C RTD #5 Max. Temperature
RTD #6 Max. Temperature 40 °C 40 °C RTD #6 Max. Temperature
RTD #7 Max. Temperature 40 °C 40 °C RTD #7 Max. Temperature
RTD #8 Max. Temperature 40 °C 40 °C RTD #8 Max. Temperature
RTD #9 Max. Temperature 40 °C 40 °C RTD #9 Max. Temperature
RTD #10 Max. Temperature 40 °C 40 °C RTD #10 Max. Temperature
RTD #11 Max. Temperature 40 °C 40 °C RTD #11 Max. Temperature
RTD #12 Max. Temperature 40 °C 40 °C RTD #12 Max. Temperature
MAINTENANCE MAINTENANCE
TRIP COUNTERS TRIP COUNTERS
Total Number of Trips 13 13 Total Number of Trips 139
Overload Trips 9
Short Circuit Trips 31
Mechanical Jam Trips 1
Current Unbalance Trips 15
Current Unbalance Trips 1 1 Ground Fault Trips 13
Phase Differential Trips 1
Motor Acceleration Trips 5 5 Motor Acceleration Trips 36
Undervoltage Trips 6 6 Undervoltage Trips 23
Overvoltage Trips 1 1 Overvoltage Trips 10

GENERAL COUNTERS GENERAL COUNTERS


Number of Motor Starts 642 642 Number of Motor Starts
Number of Emergency Restarts
Number of Starter Operations 632 632 Number of Starter Operations
TIMERS TIMERS
Motor Running Hours 6051 hr 6051 hr Motor Running Hours
Time Between Starts Timer 0 min 0 min Time Between Starts Timer
Start Timer 1 0 min 0 min Start Timer 1
Start Timer 2 0 min 0 min Start Timer 2
Start Timer 3 0 min 0 min Start Timer 3
Start Timer 4 0 min 0 min Start Timer 4
Start Timer 5 0 min 0 min Start Timer 5
PRODUCT INFORMATION PRODUCT INFORMATION
SR469 MODEL INFO. SR469 MODEL INFO.
Order Code 469-P5-HI-A20 469-P5-HI-A20 Order Code
Serial Number A3000000 A3000000 Serial Number B3000538
CALIBRATION INFO. CALIBRATION INFO.
Original Calibration Date (Info) 01/1/2 1/1/2000 Original Calibration Date (Info)
Last Calibration Date (info) 01/1/2000 1/1/2000 Last Calibration Date (info)
PRODUCT ID PRODUCT ID
Product Hardware Revision I I Product Hardware Revision
Product Software Revision 00 00 00 00 Product Software Revision
Boot Program Revision 00 00 00 00 Boot Program Revision
Boot Program Modification Number 00 00 00 Boot Program Modification Number
CH 2 CKTO 1
PASSCODE
PREFERENCES
2.0 s Default Message Cycle Time 2.0 s
300 s Default Message Timeout 300 s
15 min Average Motor Load Calculation Period 15 min
Celsius Temperature Display Unit Celsius
25% Trace Memory Trigger Position 25%
8 x 28 cycles Trace Memory Buffers 8 x 28 cycles
0.4 s Display Update Interval 0.4 s
0 cycles Motor Load Filter Interval 0 cycles

MESSAGE SCRATCHPAD
First Scratchpad Message Text 1
Second Scratchpad Message Text 2
Third Scratchpad Message Text 3
Fourth Scratchpad Message Text 4
MULTILIN 469 Motor Relay Fifth Scratchpad Message GE MULTILIN 469 Motor Relay
COMMUNICATION
255.255.252. 0 Ethernet Subnet Mask 255.255.255. 0
ID 63 DeviceNet MAC ID 1
125 kbps DeviceNet Baud Rate 125 kbps
19200 baud Front RS232 baud rate 19200 baud
2 Slave Address 2
19200 baud Computer RS485 Baud Rate 19200 baud
None Computer RS485 Parity None
19200 baud Auxiliary RS485 Baud Rate 19200 baud
None Auxiliary RS485 Parity None
SYSTEM SETUP
CURRENT SENSING
100 A Phase CT Primary 100 A
55 A Motor Full Load Amps 55 A
5 A Secondary Ground CT Type 5 A Secondary
50 A Ground CT Primary 50 A
None Phase Differential CT Type None
VOLTAGE SENSING
Open Delta VoltageTransformer Connection Type Open Delta
35.00 :1 Voltage Transformer Ratio 35.00 :1
4160 V Motor Nameplate Voltage 4160 V
POWER SYSTEM
60 Hz Nominal System Frequency 60 Hz
ABC System Phase Sequence ABC
PRESET MOTOR VALUES
Motor Running Hours 23195 hr
Positive watt Hours 1488.877 MWh
Positive var Hours 3192.256 Mvarh
Negative var Hours 0.000 Mvarh
DIGITAL INPUTS
STARTER
Start Aux a Starter Status Switch Start Aux a
OUTPUT RELAYS
TRIP RELAY
0s Force R1 Operate Time 0s
ALARM RELAY
0s Force R4 Operate Time 0s
AUX RELAY 2
0s Force R2 Output Operate Time 0s
AUX RELAY 3
0s Force R3 Operate Time 0s
BLOCK START RELAY
0s Force R5 Operate Time 0s
PROTECTION
THERMAL MODEL
469 THERMAL MODEL
Standard Curve Style Standard Standard
1.15 FLA Overload Pickup Level 1.15 FLA
3 Unbalance k Factor 3
15 min Cool Time Constant Running 15 min
30 min Cool Time Constant Stopped 30 min
1 Hot/Cold Safe Stall Ratio 1
Latched Thermal Capacity Alarm Latched
TAlarm Thermal Capacity Alarm Relays Alarm
75 % used Thermal Capacity Alarm Level 75 % used
On/Yes Thermal Capacity Alarm Events On/Yes
Trip Overload Trip Relays Trip
OVERLOAD CURVE
12 Standard Overload Curve Number 12
CURRENT ELEMENTS
SHORT CIRCUIT TRIP
Latched Short Circuit Trip Latched
On/Yes Overreach Filter On/Yes
Trip Short Circuit Trip Relays Trip
12.0 CT Short Circuit Trip Pickup 12.0 CT
50 ms Intentional Short Circuit Trip Delay 50 ms
OVERLOAD ALARM
Unlatched Overload Alarm Unlatched
Alarm Overload Alarm Relays Alarm
On/Yes Overload Alarm Events On/Yes
1.0 s Overload Alarm Delay 1.0 s
MECHANICAL JAM
Latched Mechanical Jam Trip Latched
Trip Mechanical Jam Trip Relays Trip
3.00 xFLA Mechanical Jam Pickup 3.00 xFLA
2s Mechanical Jam Delay 2s
UNDERCURRENT
0s Block Undercurrent from Start 0s
CURRENT UNBALANCE
Unlatched Current Unbalance Alarm Unlatched
Alarm Current Unbalance Alarm Relays Alarm
15% Current Unbalance Alarm Pickup 15%
9s Current Unbalance Alarm Delay 9s
On/Yes Current Unbalance Alarm Events On/Yes
Latched Current Unbalance Trip Latched
Trip Current Unbalance Trip Relays Trip
20% Current Unbalance Trip Pickup 20%
3s Current Unbalance Trip Delay 3s
GROUND FAULT
Unlatched Ground Fault Alarm Unlatched
Alarm Ground Fault Alarm Relays Alarm
0.10 CT Ground Fault Alarm Pickup 0.10 CT
200 ms Intentional GF Alarm Delay 200 ms
On/Yes Ground Fault Alarm Events On/Yes
Latched Ground Fault Trip Latched
Trip Ground Fault Trip Relays Trip
0.36 CT Ground Fault Trip Pickup 0.36 CT
110 ms Intentional GF Trip Delay 110 ms
MOTOR STARTING
ACCELERATION TIMER
Latched Accleration Timer Trip Latched
Trip Acceleration Timer Trip Relays Trip
12.0 s Acceleration Timer from Start 12.0 s
START INHIBIT
On/Yes Start Inhibit Block On/Yes
25% Thermal Capacity Used Margin 25%
om last page) JOGGING BLOCK (continued from last page)
On/Yes Jogging Block On/Yes On/Yes
4 Maximum Starts/Hour Permissible 4 4
0 min Time Between Starts 0 min 10 min
RESTART BLOCK
On/Yes Restart Block On/Yes
10 s Restart Block Time 10 s
RTD TEMPERATURE
RTD TYPES
100 Ohm Platinum Stator RTD Type 100 Ohm Platinum
100 Ohm Platinum Bearing RTD Type 100 Ohm Platinum
100 Ohm Platinum Ambient RTD Type 100 Ohm Platinum
100 Ohm Platinum Other RTD Type 100 Ohm Platinum
RTD #1
None RTD #1 Application None None

RTD #2
None RTD #2 Application None None

RTD #3
None RTD #3 Application None None

RTD #4
None RTD #4 Application None None

RTD #5
None RTD #5 Application None None

RTD #6
None RTD #6 Application None None

RTD #7
None RTD #7 Application None None

RTD #8
None RTD #8 Application None None

RTD #9
None RTD #9 Application None None

RTD #10
None RTD #10 Application None None

RTD #11
None RTD #11 Application None None

RTD #12
None RTD #12 Application None

VOLTAGE ELEMENTS
UNDERVOLTAGE
Undervoltage Alarm Unlatched
Unlatched Undervoltage Alarm Relays Alarm
Alarm Undervoltage Alarm Pickup 0.90 Rated
0.90 Rated Starting Undervoltage Alarm 0.85 Rated
0.85 Rated Undervoltage Alarm Delay 10.0 s
10.0 s Undervoltage Alarm Events On/Yes
On/Yes
OVERVOLTAGE
Unlatched Overvoltage Alarm Unlatched
Alarm Overvoltage Relays Alarm
1.05 Rated Overvoltage Alarm Pickup 1.05 Rated
10.0 s Overvoltage Alarm Delay 10.0 s
On/Yes Overvoltage Alarm Events On/Yes
Unlatched Overvoltage Trip Unlatched
Trip Overvoltage Trip Relays Trip
1.10 Rated Overvoltage Trip Pickup 1.10 Rated
3.0 s Overvoltage Trip Delay 3.0 s
PHASE REVERSAL
Latched Voltage Phase Reversal Trip Latched
Trip Voltage Phase Reversal Trip Relays Trip
POWER ELEMENTS
POWER FACTOR
1s Block Power Factor Element from Start 1s
REACTIVE POWER
1s Block kvar Element from Start 1s
UNDERPOWER
0s Block Underpower From Start 0s
REVERSE POWER
0s Block Reverse Power From Start 0s
TORQUE SETUP
0.004 mOhm Stator Resistance 0.004 mOhm
2 Pole Pairs 2
Newton-meter Torque Unit Newton-meter
OVERTORQUE SETUP
Alarm Overtorque Alarm Relays Alarm
4000.0 Nm Overtorque Alarm Level 4000.0 Nm
1.0 s Overtorque Alarm Delay 1.0 s
CURRENT DEMAND
15 min Current Demand Period 15 min
KW DEMAND
15 min kW Demand Period 15 min
KVAR DEMAND
15 min kvar Demand Period 15 min
KVA DEMAND
15 min kVA Demand Period 15 min
ANALOG OUTPUTS
None Analog Output 1 Selection None
None Analog Output 2 Selection None
None Analog Output 3 Selection None
None Analog Output 4 Selection None
STATUS
MOTOR STATUS
Stopped Motor Status Running
0.00 FLA Motor Load 0.36 FLA
0% Motor Thermal Capacity Used 0%
ENever Estimated Time to Trip on Overload Never
Low Speed (Speed 1) Motor Speed Low Speed (Speed 1)
0A Phase A Current 22A
0A Phase B Current 21A
12:00 AM Phase C Current 19A
12:00 AM Average Phase Current 21
0% Current Unbalance 1%
4126 V Vab 4122V
4075 V Vbc 4109V
4146 V Vca 4151V
4110 V Average Line Voltage 4105V
60.00 Hz System Frequency 59.95Hz
1.00 Lag Power Factor 0.28 Lag
0 kW Real Power 53 kw
0 hp Real Power (HP) 43Hp
0 kvar Reactive Power 137 kVA
0 kVA Apparent Power 140 kVA
TRIP STATUS
Trip Cause of Last Trip Acceleration Trip
15:59:05 Time of Last Trip 3:44:46
6/7/2020 Date Of LastTrip 8/8/2020
Low Speed (Speed 1) Motor Speed During Trip Low Speed (Speed 1)
0 R.P.M Pre-Trip Tachometer RPM 0 R.P.M
21 A Phase A Pre-Trip Current 390 A
22 A Phase B Pre-Trip Current 391 A
21 A Phase C Pre-Trip Current 390 A
0.36 FLA Pre-Trip Motor Load 7.09 FLA
1% Pre-Trip Current Unbalance 0%
0.00 A Pre-Trip Ground Current 0.00 A
0A Phase A Pre-Trip Differential Current 0A
12:00 AM Phase B Pre-Trip Differential Current 0A
Phase C Pre-Trip DifferentiaPhase C Pre-Trip Differential Current 0A
----- Pre-Trip Temperature of Hottest Stator RTD -----
----- Pre-Trip Temperature of Hottest Bearing RTD -----
----- Pre-Trip Temperature of Hottest Other RTD -----
----- Pre-Trip Ambient RTD Temperature -----
3467 V Pre-Trip Voltage Vab 3709 V
3393 V Pre-Trip Voltage Vbc 3694 V
3512 V Pre-Trip Voltage Vca 3717 V
0V Pre-Trip Voltage Van 0V
0V Pre-Trip Voltage Vbn 0V
0V Pre-Trip Voltage Vcn 0V
59.97 Hz Pre-Trip System Frequency 60.07 Hz
45 kW Pre-Trip Real Power 763 kW
112 kvar Pre-Trip Reactive Power 2380 kvar
121 kVA Pre-Trip Apparent Power 2499 kVA
0.37 Lag Pre-Trip Power Factor 0.31 Lag
----- Pre-Trip Temp. of Hottest Stator RTD (°F) -----
----- Pre-Trip Temp. of Hottest Bearing RTD (°F) -----
----- Pre-Trip Temp. of Hottest Other RTD (°F) -----
----- Pre-Trip Temp. of Hottest Ambient RTD (°F) -----
ALARM STATUS
Not Active Thermal Capacity Alarm Status Not Active
Not Active Overload Alarm Status Not Active
Not Active Current Unbalance Alarm Status Not Active
Not Active Ground Fault Alarm Status Not Active
Not Active Undervoltage Alarm Status Not Active
Not Active Overvoltage Alarm Status Not Active
0 min Overload Lockout Block 0 min
0 min Start Inhibit Block Lockout Time 0 min
0 min Start/Hour Block Lockout Time 0 min
0 min Time Between Starts Lockout Time 0 min
0s Restart Block Lockout 0s
INPUTS STATUS
Open Access Switch Status Open
Open Test Switch Status Open
Open Starter Switch Status Open
Open Emergency Restart Switch Status Open
Open Remote Reset Switch Status Open
Open Assignable Input 1 Status Open
Open Assignable Input 2 Status Open
Open Assignable Input 3 Status Open
Open Assignable Input 4 Status Open
No Coil Trip Coil Supervision No Coil
BLOCK STATUS
0 min Overload Lockout Block 0 min
0 min Start Inhibit Block Lockout Time 0 min
0 min Start/Hour Block Lockout Time 0 min
0 min Time Between Starts Lockout Time 0 min
0s Restart Block Lockout 0s
CLOCK STATUS
5/10/2020 Date for Real Time Clock 5/10/2020
10:04:13 Time for Real Time Clock 10:17:50
SYSTEM STATUS
Active General Status Relay in Service Active
Inactive General Status Active Trip Condition Inactive
Inactive General Status Active Alarm Condition Inactive
Active General Status Motor Stopped Inactive
Inactive General Status Motor Starting Inactive
Inactive General Status Running Active
Inactive General Status Overload Pickup Inactive
Inactive General Status Unbalance Pickup Inactive
Inactive General Status Ground Pickup Inactive
Inactive General Status Hot RTD Inactive
Inactive General Status Loss of Load Inactive
Inactive Output Relay Status R1 Trip Inactive
Inactive Output Relay Status R2 Auxiliary Inactive
Inactive Output Relay Status R3 Auxiliary Inactive
Inactive Output Relay Status R4 Alarm Inactive
METERING DATA
CURRENT
0A Phase A Current 22A
0A Phase B Current 21A
0A Phase C Current 19A
0A Average Phase Current 21A
0.00 FLA Motor Load 0.36 FLA
0% Current Unbalance 1%
0.00 FLA U/B Biased Motor Load 0.38 FLA
0.00 A Ground Current 0.00 A
RTD
No RTD RTD #1 Temperature No RTD
No RTD RTD #2 Temperature No RTD
No RTD RTD #3 Temperature No RTD
No RTD RTD #4 Temperature No RTD
No RTD RTD #5 Temperature No RTD
No RTD RTD #6 Temperature No RTD
No RTD RTD #7 Temperature No RTD
No RTD RTD #8 Temperature No RTD
No RTD RTD #9 Temperature No RTD
No RTD RTD #10 Temperature No RTD
No RTD RTD #11 Temperature No RTD
No RTD RTD #12 Temperature No RTD
No RTD Hottest Stator RTD No RTD
None RTD #1 Application None
None RTD #2 Application None
None RTD #3 Application None
None RTD #4 Application None
None RTD #5 Application None
None RTD #6 Application None
None RTD #7 Application None
None RTD #8 Application None
None RTD #9 Application None
None RTD #10 Application None
None RTD #11 Application None
None RTD #12 Application None
VOLTAGE
4126 V Vab 4122 V
4075 V Vbc 4109 V
4146 V Vca 4151 V
4110 V Average Line Voltage 4105 V
60.00 Hz System Frequency 59.95 Hz
POWER
1 Power Factor 0.28 Lag
0 kW Real Power 53 kW
0 hp Real Power (HP) 43 hp
0 kvar Reactive Power 137 kvar
0 kVA Apparent Power 140 Kva
3695.260 MWh Positive watt Hours 1488.877 MWh
8556.681 Mvarh Positive var Hours 3192.256 Mvarh
0.000 Mvarh Negative var Hours 0.000 Mvarh
DEMAND
14 A Current Demand 21 A
25 kW Real Power Demand 57 kW
97 kvar Reactive Power Demand 136 kvar
102 kVA Apparent Power Demand 150 kVA
32 A Peak Current Demand 34 A
126 kW Peak Real Power Demand 166 kW
172 kvar Peak Reactive Power Demand 147 kvar
218 kVA Peak Apparent Power Demand 224 kVA
PHASOR
0 A 216 ° VALUEar: Phase A Current 22 A 114 °
0 A 126 ° VALUEar: Phase B Current 21 A 236 °
0 A 306 ° VALUEar: Phase C Current 19 A 356 °
4.126 kV 0 ° VALUEar: Vab 4.122 kV 0 °
4075 V 298 ° VALUEar: Vbc 4109 V 300 °
4146 V 127 ° VALUEar: Vca 4151 V 220 °
0V0° VALUEar: Van 0V0°
0 V 127 ° VALUEar: Vbn 0 V 220 °
0 V 298 ° 0 V 298 ° 0 V 300 °
LEARNED DATA
MOTOR LEARNED DATA
2.3 s Learned Acceleration Time 1.8 s
388 A Learned Starting Current 403 A
9% Learned Starting Capacity 8%
1.8 s Last Acceleration Time 1.8 s
380 A Last Starting Current 408 A
7% Last Starting Capacity 8%
0.22 FLA Average Motor Load Learned 0.38 FLA
RTD LEARNED DATA
No RTD RTD #1 Max. Temperature No RTD
No RTD RTD #2 Max. Temperature No RTD
No RTD RTD #3 Max. Temperature No RTD
No RTD RTD #4 Max. Temperature No RTD
No RTD RTD #5 Max. Temperature No RTD
No RTD RTD #6 Max. Temperature No RTD
No RTD RTD #7 Max. Temperature No RTD
No RTD RTD #8 Max. Temperature No RTD
No RTD RTD #9 Max. Temperature No RTD
No RTD RTD #10 Max. Temperature No RTD
No RTD RTD #11 Max. Temperature No RTD
No RTD RTD #12 Max. Temperature No RTD
MAINTENANCE
TRIP COUNTERS
139 Total Number of Trips 167
9 Overload Trips 1
31 Short Circuit Trips 39
1 Mechanical Jam Trips 1
15 Current Unbalance Trips 15
13 Ground Fault Trips 22
1
36 Motor Acceleration Trips 14
23 Undervoltage Trips 68
10 Overvoltage Trips 5
Voltage Phase Reversal Trips 2
GENERAL COUNTERS
6147 Number of Motor Starts 5771
68 Number of Emergency Restarts 6
6109 Number of Starter Operations 5740
TIMERS
57262 hr Motor Running Hours 23195 hr
0 min Time Between Starts Timer 0 min
0 min Start Timer 1 0 min
0 min Start Timer 2 0 min
0 min Start Timer 3 0 min
0 min Start Timer 4 0 min
0 min Start Timer 5 0 min
PRODUCT INFORMATION
SR469 MODEL INFO.
469-P5-HI-A20-E Order Code 469-P5-HI-A20-E
B3000538 Serial Number B3000538 B3004056
CALIBRATION INFO.
02/17/2010 Original Calibration Date (Info) 11/13/2010
02/17/2010 Last Calibration Date (info) 1/1/2000
PRODUCT ID
I Product Hardware Revision I
00 00 Product Software Revision 05 10
00 00 Boot Program Revision 00 00
00 00 Boot Program Modification Number 00 00
Date of Event 4/10/2020 4/10/2020
Time of Event '18:09:17.23 '17:54:02.42
Cause of Event Undervoltage Alarm Motor Started
Motor Speed Low Speed (Speed 1) Low Speed (Speed 1)
Tachometer (RPM) 0 0
Phase A Current (Amps) 25 394
Phase B Current (Amps) 25 393
Phase C Current (Amps) 24 401
Motor Load (FLA) 0.45 7.2
Current Unbalance (%) 1 3
Ground Current (Amps) 0 0
Phase A Diff. Current (Amps) 0 0
Phase B Diff. Current (Amps) 0 0
Phase C Diff. Current (Amps) 0 0
Hottest Stator RTD# 0 0
Hottest Stator RTD Temperature (°C) -52 -52
Hottest Bearing RTD# 0 0
Hottest Bearing RTD Temperature (°C) -52 -52
Hotter Other RTD# 0 0
Hottest Other RTD Temperature (°C) -52 -52
Hottest Ambient RTD# 0 0
Ambient RTD RTD Temperature (°C) -52 -52
Phase A-B Voltage (Volts) 3492 3754
Phase B-C Voltage (Volts) 3519 3496
Phase C-A Voltage (Volts) 3533 3864
Phase A-N Voltage (Volts) 0 0
Phase B-N Voltage (Volts) 0 0
Phase C-N Voltage (Volts) 0 0
Frequency (Hz) 59.99 59.93
Real Power (KW) 93 628
Reactive Power (Kvar) 119 2414
Apparent Power (KVA) 151 2494
Power Factor 0.62 0.25
Analog Input 1 (Units) 0 0
Analog Input 2 (Units) 0 0
Analog Input 3 (Units) 0 0
Analog Input 4 (Units) 0 0
Torque (Nm) 0 0
Event Temp. of Hottest Stator RTD(Fahrenheit -61 -61
Event Temp. of Hottest Bearing RTD(Fahrenhe -61 -61
Event Temp. of Hottest Other RTD(Fahrenheit -61 -61
Event Temp. of Hottest Ambient RTD(Fahrenhe -61 -61
4/10/2020 4/10/2020
'17:47:25.09 '17:43:03.44
Cont. Power Applied Control Power Lost Undervoltage Alarm Motor Started
Low Speed (Speed 1) Low Speed (Speed 1) Low Speed (Speed 1) Low Speed (Speed 1)
0 0 0 0
0 0 21 404
0 0 22 406
0 0 21 372
0 0 0.38 7.16
0 0 1 13
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
-52 -52 -52 -52
0 0 0 0
-52 -52 -52 -52
0 0 0 0
-52 -52 -52 -52
0 0 0 0
-52 -52 -52 -52
0 0 3536 3534
0 0 3501 3732
0 0 3539 3712
0 0 0 0
0 0 0 0
0 0 0 0
0 0 60 60.01
0 0 52 1185
0 0 117 2130
0 0 129 2437
0 0 0.4 0.49
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
-61 -61 -61 -61
-61 -61 -61 -61
-61 -61 -61 -61
-61 -61 -61 -61
Cont. Power Applied Control Power Lost Undervoltage Alarm
Low Speed (Speed 1) Low Speed (Speed 1) Low Speed (Speed 1)
0 0 0
0 0 25
0 0 25
0 0 24
0 0 0.45
0 0 1
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
-52 -52 -52
0 0 0
-52 -52 -52
0 0 0
-52 -52 -52
0 0 0
-52 -52 -52
0 0 3457
0 0 3371
0 0 3538
0 0 0
0 0 0
0 0 0
0 0 60
0 0 83
0 0 118
0 0 145
0 0 0.58
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
-61 -61 -61
-61 -61 -61
-61 -61 -61
-61 -61 -61