S2 Datasheet PDF

The document summarizes the RKI S2 series gas sensor/transmitters. It states that the S2 series can detect various gases including LEL, H2S, CO, H2, and CO2. It also detects toxic gases like NH3, AsH3, Cl2, ClO2, HCN, and SO2. The transmitters for combustible/toxic gases are explosion-proof. They have a patented water-repellent coating and 4-20 mA output. The S2 series can interface with RKI controllers and PLC/DCS systems from up to 8,000 feet away depending on wire gauge.

Uploaded by

Nelson Guerrero
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views4 pages

S2 Datasheet PDF

The document summarizes the RKI S2 series gas sensor/transmitters. It states that the S2 series can detect various gases including LEL, H2S, CO, H2, and CO2. It also detects toxic gases like NH3, AsH3, Cl2, ClO2, HCN, and SO2. The transmitters for combustible/toxic gases are explosion-proof. They have a patented water-repellent coating and 4-20 mA output. The S2 series can interface with RKI controllers and PLC/DCS systems from up to 8,000 feet away depending on wire gauge.

Uploaded by

Nelson Guerrero
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

FO26-1710/1000

S2 SENSOR / TRANSMITTER S2 SENSOR / TRANSMITTER

— Available gases include


◦ LEL, H2S, CO, PPM H2, and CO2
Explosion Proof
O2 / CO / H2S ◦ Toxic gases include NH3, AsH3,
Cl2, ClO2, HCN, & SO2
— Infrared sensor for combustibles
AC power supply Remote horns & lights and CO2
Explosion Proof
LEL — Hydrogen-Specific now available
Calibration kits
— Patented water repellent sensor coating
NH3 Sensor — 4-20 mA output
— Explosion proof construction
Calibration adaptors Splash guards — Optional stainless steel junction box

Remote Mount
Flow through adaptors Dataloggers Calibration Adaptor

Direct Interface with Beacon 110 / 200 / 410A / 800 Controllers


S2 Wiring Matrix
Number Maximum Distance to Controller
S2 of The RKI S2 series gas sensor/transmitters are highly reliable and very cost effective for the detection of common gas
Transmitter Wires to 18 AWG 16 AWG 14 AWG hazards. The S2 series are available for LEL, H2 Specific (LEL, and ppm), Oxygen, H2S, CO, and for a variety of toxic
Controller wire wire wire gases. The transmitters for LEL, H2 Specific, Oxygen, H2S, CO2, and Carbon Monoxide are explosion-proof with flame
LEL / IR / CO2 3 2500 ft. 5,000 ft. 8,000 ft. arrestors, and approved for use in hazardous areas (Class l, Div 1 Groups B, C, D). An optional non-explosion proof
version is available for oxygen, H2S, CO, and CO2 in non-hazardous atmospheres. LEL sensors are available using
Oxygen 2 2500 ft. 5,000 ft. 8,000 ft. catalytic bead and infrared technologies.
H2S 2 2500 ft. 5,000 ft. 8,000 ft.
The toxic sensors are electrochemical type plug-in sensors, which provide high specificity, fast response, and long life.
CO 2 2500 ft. 5,000 ft. 8,000 ft. The plug-in design allows quick replacement in the field with no tools required. Toxic sensors are designed for use in
Toxics 2 2500 ft. 5,000 ft. 8,000 ft. Class I, Div. 2 hazardous locations. Sensors available for NH3, AsH3, Cl2, ClO2, HCN, PH3, and SO2.
Made in the USA The S2 transmitters can be used either indoors or outdoors. The flame arrestors for the explosion-proof versions
utilize a patented coating which make them water repellent. Splash guards are also available for use in very wet
Authorized Distributor:
environments. An optional stainless steel junction box is available for corrosive environments.
All of the S2 transmitters are designed to interface with RKI controllers, or with PLC/DCS systems.

World Leader In Gas Detection & Sensor Technology

RKI Instruments, Inc. | 33248 Central Ave. Union City, CA 94587 | Phone (800) 754-5165 | (510) 441-5656 | Fax (510) 441-5650
Gas Detection For Life www.rkiinstruments.com
Explosion Proof Non Explosion Proof
LEL LEL H2 PPM O2 H2S CO CH4 HC CO2
General H2 Specific Hydrogen Oxygen Hydrogen Carbon Methane Hydrocarbons Carbon O2 H2S CO Toxics CO2
Oxygen Hydrogen Sulfide Carbon Monoxide See chart below Carbon Dioxide
Purpose Sulfide Monoxide Dioxide

65-2396RK-02 65-2397RK-02
65-2405RK 65-2451RK 65-2442RK-1000
65-2396RK-03 See chart 65-2397RK-03
Part # 65-2322RK 65-2331RK 65-2336RK 65-2394RK-CH4 65-2394RK-HC Part # 65-2320RK 65-2330RK 65-2335RK
65-2396RK-05 below 65-2397RK-05
65-2405RK-05 65-2451RK-05 65-2442RK-2000
65-2396RK-10 65-2397RK-10
Metal oxide
Sensor Catalytic
semiconductor
Galvanic cell Electrochemical Infrared Sensor Galvanic cell Electrochemical Infrared

0-1000 ppm 0 - 5000 ppm 0 - 5000 ppm


0-100% LEL 0 - 5% Vol. See chart 0 - 5% Vol.
Measuring Range 0-100% LEL 0-25% Vol. 0-100 ppm 0-300 ppm 0-100% LEL Measuring Range 0-25% Vol. 0-100 ppm 0-300 ppm
(H2 Specific) 0 - 50% Vol. below 0 - 50% Vol.
0-2000 ppm 0 - 100% Vol.
0 - 100% Vol.

Lower Detectable Lower Detectable Limit (LDL) 0.1% Vol. 2% of full scale
2% of full scale 0.1% Vol. 2% of full scale
Limit (LDL)
Accuracy ± 5% of ± 5% of ± 10% of ± 5% of
Accuracy ± 5% of ± 10% of ± 5% of ± 5% of ± 5% of ± 0.5% O2 reading reading reading or reading or
(whichever is greater) ± 2 ppm H2S ± 5 ppm CO ± 5% of full scale ± 2% of full scale
(whichever is reading or reading or ± 0.5% O2 reading reading reading or
greater) ± 2% LEL ± 5% of full scale ± 2 ppm H2S ± 5 ppm CO ± 2% of full scale
Response Time (T-90) 20 Seconds 45 Seconds 30 Seconds 60 Seconds 30 Seconds
Response Time 60 mA (power wires)
30 Seconds 20 Seconds 45 Seconds 90 Seconds 60 Seconds 90 Seconds 30 Seconds
(T-90) Max Current Draw (24VDC) 25 mA max, 2 wires 25 mA (signal wires)
Max Current Draw 60 mA (power wires) 3 wires
70 mA (power wires) 25 mA (signal wires) 3 wires 25 mA max, 2 wires
(24VDC) 25 mA (signal wires) 3 wires
2 years normal 5 years plus with
Life Expectancy 2 to 3 years with normal service
2 to 3 years service normal service
Life with normal 3-5 years with 5 years plus with
Expectancy exposure to normal service normal service
2-3 years with normal service 5 years plus with normal service Operating Environment
flammable gas
Location Indoor Class I, Div. 2
Operating Environment -4°F to 122°F 14°F to 104°F -40°F to 122°F
Temperature
-20°C to 50°C -10°C to 40°C -40°C to 50°C
Location Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D.
0 - 99% RH
-40°F to 167°F -40°F to 167°F -4°F to 113°F -40°F to 104°F 23°F to 104°F -40°F to 122°F Humidity 0 - 99% RH non condensing 5-95% RH
Temperature non condensing
-40°C to 75°C -40°C to 75°C -20°C to 45°C -40°C to 40°C -5°C to 40°C -40°C to 50°C
Housing
Humidity 0 - 99% RH, non condensing
Housing J-Box Cast aluminum, explosion-proof
Housing
Sensor Plastic or aluminum
Housing J Box Cast aluminum explosion proof, optional stainless steel J-box available
Controls
Sensor Stainless steel explosion proof
Zero Sets transmitter output to 4 mA with zero output from sensor

Controls Span Sets transmitter output to 20 mA with full scale output from sensor

Zero Sets transmitter output to 4 mA with zero output from sensor Operating Voltage 19 VDC to 30 VDC

Span Sets transmitter output to proper level when span gas is applied Output 4-20 mA signal

Output 4 - 20 mA signal Controllers Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410A, and 800, also PLC and DCS systems

Operating 19-30VDC (250 OHMS Warranty One year materials and workmanship
11 VDC to 30 VDC 19 VDC to 30 VDC impedance max) 11 VDC to 30 VDC
Voltage * Partial pressure sensor for helium (He) applications. Consult factory for details.

65-2405RK 65-2451RK Non Explosion Proof Toxic Assemblies


UL UL
Part Number With J-Box Gas Range Resolution Sensor Type
Approvals UL CSA NRTL C UL US
65-2405RK-05 65-2451RK-05 65-2340RK-NH3 Ammonia (NH3) 0 - 75.0 ppm 0.1 ppm ESM -01
CSA CSA 65-2340RK-AsH3 Arsine (AsH3) 0 - 1.50 ppm 0.01 ppm ESM -01

Controllers Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410A, and 800, also PLC and DCS systems 65-2341-CL2 Chlorine (Cl2) 0 - 3.00 ppm 0.01 ppm CT-7

65-2341-CL2-10 Chlorine (Cl2) 0 - 10.0 ppm 0.1 ppm CT-7


Warranty One year materials and workmanship
65-2341-CLO2 Chlorine Dioxide (ClO2) 0 - 1.00 ppm 0.01 ppm CT-7

65-2340RK-HCN Hydrogen Cyanide (HCN) 0 - 15.0 ppm 0.1 ppm ESM -01

65-2340RK-PH3 Phosphine (PH3) 0 - 1.00 ppm 0.01 ppm ESM -01


ESM-01 CT-7 65-2340RK-SO2 Sulfur Dioxide (SO2) 0 - 6.00 ppm 0.01 ppm ESM -01

www.rkiinstruments.com S2 Sensor / Transmitter (800) 754-5165 S2 Sensor / Transmitter


Explosion Proof Non Explosion Proof
LEL LEL H2 PPM O2 H2S CO CH4 HC CO2
General H2 Specific Hydrogen Oxygen Hydrogen Carbon Methane Hydrocarbons Carbon O2 H2S CO Toxics CO2
Oxygen Hydrogen Sulfide Carbon Monoxide See chart below Carbon Dioxide
Purpose Sulfide Monoxide Dioxide

65-2396RK-02 65-2397RK-02
65-2405RK 65-2451RK 65-2442RK-1000
65-2396RK-03 See chart 65-2397RK-03
Part # 65-2322RK 65-2331RK 65-2336RK 65-2394RK-CH4 65-2394RK-HC Part # 65-2320RK 65-2330RK 65-2335RK
65-2396RK-05 below 65-2397RK-05
65-2405RK-05 65-2451RK-05 65-2442RK-2000
65-2396RK-10 65-2397RK-10
Metal oxide
Sensor Catalytic
semiconductor
Galvanic cell Electrochemical Infrared Sensor Galvanic cell Electrochemical Infrared

0-1000 ppm 0 - 5000 ppm 0 - 5000 ppm


0-100% LEL 0 - 5% Vol. See chart 0 - 5% Vol.
Measuring Range 0-100% LEL 0-25% Vol. 0-100 ppm 0-300 ppm 0-100% LEL Measuring Range 0-25% Vol. 0-100 ppm 0-300 ppm
(H2 Specific) 0 - 50% Vol. below 0 - 50% Vol.
0-2000 ppm 0 - 100% Vol.
0 - 100% Vol.

Lower Detectable Lower Detectable Limit (LDL) 0.1% Vol. 2% of full scale
2% of full scale 0.1% Vol. 2% of full scale
Limit (LDL)
Accuracy ± 5% of ± 5% of ± 10% of ± 5% of
Accuracy ± 5% of ± 10% of ± 5% of ± 5% of ± 5% of ± 0.5% O2 reading reading reading or reading or
(whichever is greater) ± 2 ppm H2S ± 5 ppm CO ± 5% of full scale ± 2% of full scale
(whichever is reading or reading or ± 0.5% O2 reading reading reading or
greater) ± 2% LEL ± 5% of full scale ± 2 ppm H2S ± 5 ppm CO ± 2% of full scale
Response Time (T-90) 20 Seconds 45 Seconds 30 Seconds 60 Seconds 30 Seconds
Response Time 60 mA (power wires)
30 Seconds 20 Seconds 45 Seconds 20 Seconds 45 Seconds 30 Seconds 30 Seconds
(T-90) Max Current Draw (24VDC) 25 mA max, 2 wires 25 mA (signal wires)
Max Current Draw 60 mA (power wires) 3 wires
70 mA (power wires) 25 mA (signal wires) 3 wires 25 mA max, 2 wires
(24VDC) 25 mA (signal wires) 3 wires
2 years normal 5 years plus with
Life Expectancy 2 to 3 years with normal service
2 to 3 years service normal service
Life with normal 3-5 years with 5 years plus with
Expectancy exposure to normal service normal service
2-3 years with normal service 5 years plus with normal service Operating Environment
flammable gas
Location Indoor Class I, Div. 2
Operating Environment -4°F to 122°F 14°F to 104°F -40°F to 122°F
Temperature
-20°C to 50°C -10°C to 40°C -40°C to 50°C
Location Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D.
0 - 99% RH
-40°F to 167°F -40°F to 167°F -4°F to 113°F -40°F to 122°F 23°F to 104°F -40°F to 122°F Humidity 0 - 99% RH non condensing 5-95% RH
Temperature non condensing
-40°C to 75°C -40°C to 75°C -20°C to 45°C -40°C to 50°C -5°C to 40°C -40°C to 50°C
Housing
Humidity 0 - 99% RH, non condensing
Housing J-Box Cast aluminum, explosion-proof
Housing
Sensor Plastic or aluminum
Housing J Box Cast aluminum explosion proof, optional stainless steel J-box available
Controls
Sensor Stainless steel explosion proof
Zero Sets transmitter output to 4 mA with zero output from sensor

Controls Span Sets transmitter output to 20 mA with full scale output from sensor

Zero Sets transmitter output to 4 mA with zero output from sensor Operating Voltage 19 VDC to 30 VDC

Span Sets transmitter output to proper level when span gas is applied Output 4-20 mA signal

Output 4 - 20 mA signal Controllers Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410A, and 800, also PLC and DCS systems

Operating 19-30VDC (250 OHMS Warranty One year materials and workmanship
11 VDC to 30 VDC 19 VDC to 30 VDC impedance max) 11 VDC to 30 VDC
Voltage * Partial pressure sensor for helium (He) applications. Consult factory for details.

65-2405RK 65-2451RK Non Explosion Proof Toxic Assemblies


UL UL
Part Number With J-Box Gas Range Resolution Sensor Type
Approvals UL CSA NRTL C UL US
65-2405RK-05 65-2451RK-05 65-2340RK-NH3 Ammonia (NH3) 0 - 75.0 ppm 0.1 ppm ESM -01
CSA CSA 65-2340RK-AsH3 Arsine (AsH3) 0 - 1.50 ppm 0.01 ppm ESM -01

Controllers Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410A, and 800, also PLC and DCS systems 65-2341-CL2 Chlorine (Cl2) 0 - 3.00 ppm 0.01 ppm CT-7

65-2341-CL2-10 Chlorine (Cl2) 0 - 10.0 ppm 0.1 ppm CT-7


Warranty One year materials and workmanship
65-2341-CLO2 Chlorine Dioxide (ClO2) 0 - 1.00 ppm 0.01 ppm CT-7

65-2340RK-HCN Hydrogen Cyanide (HCN) 0 - 15.0 ppm 0.1 ppm ESM -01

65-2340RK-PH3 Phosphine (PH3) 0 - 1.00 ppm 0.01 ppm ESM -01


ESM-01 CT-7 65-2340RK-SO2 Sulfur Dioxide (SO2) 0 - 6.00 ppm 0.01 ppm ESM -01

www.rkiinstruments.com S2 Sensor / Transmitter (800) 754-5165 S2 Sensor / Transmitter


FO26-1710/1000

S2 SENSOR / TRANSMITTER S2 SENSOR / TRANSMITTER

— Available gases include


◦ LEL, H2S, CO, PPM H2, and CO2
Explosion Proof
O2 / CO / H2S ◦ Toxic gases include NH3, AsH3,
Cl2, ClO2, HCN, & SO2
— Infrared sensor for combustibles
AC power supply Remote horns & lights and CO2
Explosion Proof
LEL — Hydrogen-Specific now available
Calibration kits
— Patented water repellent sensor coating
NH3 Sensor — 4-20 mA output
— Explosion proof construction
Calibration adaptors Splash guards — Optional stainless steel junction box

Remote Mount
Flow through adaptors Dataloggers Calibration Adaptor

Direct Interface with Beacon 110 / 200 / 410A / 800 Controllers


S2 Wiring Matrix
Number Maximum Distance to Controller
S2 of The RKI S2 series gas sensor/transmitters are highly reliable and very cost effective for the detection of common gas
Transmitter Wires to 18 AWG 16 AWG 14 AWG hazards. The S2 series are available for LEL, H2 Specific (LEL, and ppm), Oxygen, H2S, CO, and for a variety of toxic
Controller wire wire wire gases. The transmitters for LEL, H2 Specific, Oxygen, H2S, CO2, and Carbon Monoxide are explosion-proof with flame
LEL / IR / CO2 3 2500 ft. 5,000 ft. 8,000 ft. arrestors, and approved for use in hazardous areas (Class l, Div 1 Groups B, C, D). An optional non-explosion proof
version is available for oxygen, H2S, CO, and CO2 in non-hazardous atmospheres. LEL sensors are available using
Oxygen 2 2500 ft. 5,000 ft. 8,000 ft. catalytic bead and infrared technologies.
H2S 2 2500 ft. 5,000 ft. 8,000 ft.
The toxic sensors are electrochemical type plug-in sensors, which provide high specificity, fast response, and long life.
CO 2 2500 ft. 5,000 ft. 8,000 ft. The plug-in design allows quick replacement in the field with no tools required. Toxic sensors are designed for use in
Toxics 2 2500 ft. 5,000 ft. 8,000 ft. Class I, Div. 2 hazardous locations. Sensors available for NH3, AsH3, Cl2, ClO2, HCN, PH3, and SO2.
Made in the USA The S2 transmitters can be used either indoors or outdoors. The flame arrestors for the explosion-proof versions
utilize a patented coating which make them water repellent. Splash guards are also available for use in very wet
Authorized Distributor:
environments. An optional stainless steel junction box is available for corrosive environments.
All of the S2 transmitters are designed to interface with RKI controllers, or with PLC/DCS systems.

World Leader In Gas Detection & Sensor Technology

RKI Instruments, Inc. | 33248 Central Ave. Union City, CA 94587 | Phone (800) 754-5165 | (510) 441-5656 | Fax (510) 441-5650