26360, 80207 NAMUR
3/2, 5/2 & 5/3 spool valves
electromagnetic actuated, indirectly controlled
G 1/4 and NAMUR interface
For single and double operated actuators
Manual override with and without detent
Simple design of soft seal spool system
Easily interchangeable solenoid
Maintenance-free
All valves available with Ex protected
coils (ATEX or other international approvals)
Approval depends on magnetic
system, see page 3!
Technical features
Medium: Mounting: Materials:
Compressed air, filtered, Optional, preferably with Housing: aluminium anodised
lubricated or non-lubricated solenoid on top Pilot flange: plastic (POM)
Operation: Fluid/Ambient temperature: Seals: NBR
Indirect solenoid operated -10 ... +60°C
T-spool valves Depending on solenoid system
Port size: Air supply must be dry enough
G 1/4 to avoid ice formation at
Operating pressure: temperatures below +2°C.
max. 10 bar (see specifications)
Flow direction:
Fixed
Technical data
3/2 way
Symbol Port size Operating pressure Flow Switching time Manual override Weight without Dimension Model *1)
1, 2 3, 4 (bar) min. max. (l/min) (ms) with/without detent solenoid (kg) No.
2 3 G 1/4 Flange 1 10 1200 35 – 0,24 1 8020745
1 3
2 3 G 1/4 Flange 1 10 1200 35 without 0,24 1 8020746
1 3
2 3 G 1/4 Flange 1 10 1200 35 with 0,24 1 8020747
1 3
*1) When ordering, please indicate solenoid, voltage and current (frequency).
12/11 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en 5.4.386.01
26360, 80207 NAMUR
5/2 way
Symbol Port size Operating pressure Flow Switching time Manual override Weight without Dimension Model *1)
1, 2 3, 4 (bar) min. max. (l/min) (ms) with/without detent solenoid (kg) No.
4 2 G 1/4 Flange 1 10 1200 35 – 0,55 2 2636045
4 2
513
513
4 2 G 1/4 Flange 1 10 1200 35 without 0,55 2 2636046
513
4 2 G 1/4 Flange 1 10 1200 35 with 0,55 2 2636047
513
44 2 G 1/4 Flange 1 10 1200 30 – 0,90 3 2636245
2
5 11 3
5 3
G 1/4 Flange 1 10 1200 30 without 0,90 3 2636246
4 2
513
42 2 G 1/4 Flange 1 10 1200 30 with 0,90 3 2636247
53 1 3
5/3 way
Symbol Port size Operating pressure Flow Switching time Manual override Weight without Dimension Model *1)
1, 2 3, 4 (bar) min. max. (l/min) (ms) with/without detent solenoid (kg) No.
4 2 G 1/4 Flange 3 10 950 40 with 1,0 4 2636447
513
*1) When ordering, please indicate solenoid, voltage and current (frequency).
N/en 5.4.386.02 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12/11
26360, 80207 NAMUR
Solenoid operators
Power consumption Rated current Ex-Protection Protection Temperature Electrical connection Weight Dimension Circuit Model
24 V d.c. 230 V a.c. 24 V d.c. 230 V a.c. (ATEX- class *7) Ambient/ No. diagram
(W) (VA) (mA) (mA) Category) Fluid (°C) (kg) No.
2,7 - 113 - - IP 65 with -25 ... +60 Connector 0,15 1 1 0242
connector *5) Fluid: max. 80 DIN EN 175301-803
Form A *6)
- 4,2 - - - IP 65 with -25 ... +60 Connector 0,16 1 1 0245
connector *5) Fluid: max. 80 DIN EN 175301-803
Form A *6)
2,7 - 331 - II3G Ex nA II T4 -20 ... +60 Connector 0,16 1 1 3215
II3D Ex tD A22 IP65 DIN EN 175301-803 Form A
T90°C included in delivery
3,6 - 150 - II2G Ex m II T4 -20 ... +70 Cable 3 m 0,4 5 4 0298
II2D Ex tD A21 IP66 *8)
T 110°C *1)
- 4,6 - 18 II2G Ex m II T4 -20 ... +70 Cable 3 m 0,4 5 7 0299
II2D Ex tD A21 IP66 *8)
T 110°C *1)
3,9 - 162 - II2G Ex emb II T4/T6 -40 ...+55 T6 M20 x 1,5 *6) 0,5 6 4 4210
II2D Ex tD A21 -40 ... +80 T4 *8)
IP66 T130°C *2), *10)
- 5,3 - 23 II2G Ex emb II T4/T6 -40 ...+55 T6 M20 x 1,5 *6) 0,5 6 7 4211
II2D Ex tD A21 -40 ... +80 T4 *8)
IP66 T130°C *2), *10)
3,9 - 162 - II2G Ex dmb IIC T4/T6 -40 ...+55 T6 1/2-14 NPT *6) 0,8 7 4 4610
Ex emb II T4/T6 -40 ... +80 T4 *8)
II2D Ex tD A21
IP66 T130°C *3)
- 5,3 - 23 II2G Ex dmb IIC T4/T6 -40 ...+55 T6 1/2-14 NPT *6) 0,8 7 7 4611
Ex emb II T4/T6 -40 ... +80 T4 *8)
II2D Ex tD A21
IP66 T130°C *3)
3,9 - 162 - II2G Ex dmb IIC T4/T6 -40 ...+55 T6 M20 x 1,5 *6) 0,8 7 4 4612
Ex emb II T4/T6 -40 ... +80 T4 *8)
II2D Ex tD A21
IP66 T130°C *3)
- 5,3 - 23 II2G Ex dmb IIC T4/T6 -40 ...+55 T6 M20 x 1,5 *6) 0,8 7 7 4613
Ex emb II T4/T6 -40 ... +80 T4 *8)
II2D Ex tD A21
IP66 T130°C *3)
5,5 - - 228 - XP/DIP, Div. 1 u. 2 -20 ... +60 Flying leads 450 mm 0,5 8 1 3722
CI. I, Gr. A-D
CI. II, Gr. E-G
CI. III,
T3 (160°C) *4)
NEMA 4, 4X,
6, 6P, 7, 9
- 5,9 - 26 - XP/DIP, Div. 1 u. 2 -20 ... +60 Flying leads 450 mm 0,5 8 5 3723
CI. I, Gr. A-D
CI. II, Gr. E-G
CI. III,
T3 (160°C) *4)
NEMA 4, 4X,
6, 6P, 7, 9
Standardvoltages 24 V d.c., 230 V a.c., other voltages on request. *8) Suitable for outdoor installation
Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *10) IEC Ex Certificate of Conformity
*1) EG-Type-Examination-Certificate KEMA 02 ATEX 1347X Attention:
*2) EG-Type-Examination-Certificate KEMA 98 ATEX 4452 X The protection class for coil series 46xx is determined by the choice of
cable gland.
*3) EG-Type-Examination-Certificate PTB 02 ATEX 2085 X
Example: if an ATEX-certified cable gland is used that has Ex d type of
*4) CSA-LR 57643-6, FM Approval protection, the solenoid will have the protection class Ex dmb;
*5) Required connector: type 0570275 if a cable gland with Ex e type of proteciton is used, the solenoid will
*6) Connector cable gland not supplied, see table »Accessories« have protection class Ex emb.
*7) IP-Protection class according to EN60529
12/11 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en 5.4.386.03
26360, 80207 NAMUR
Accessories
Cable gland
Protection class Ex e, Ex d
(ATEX),
Nickel plated brass
Page 10
Thread Cable Ø Material Protection class (ATEX) Model
M 20x1,5 5,0...8,0 mm Nickel plated brass II2GD Ex e 0588819
M 20x1,5 10...14 mm Nickel plated brass II2GD Ex d 0588851
1/2-14-NPT 7,5...11,9 mm Nickel plated brass II2GD Ex d 0588925
Accessories
Connector Silencer *1) Exhaust guard *2) Throttle control plate Flange plate Yoke
Form A
Page 10 Page 10 Page 9 Page 9 Page 9
0570275 M/S2 (G1/4) 0613422 (G1/4 or 1/4 NPT) 4040239 0612790 (NAMUR single connection plate) 0540593
C/S2 (1/4 NPT) 0612791 (NAMUR-rip use in combination with 0612790, Alu)
*1) For indoors use
*2) For outdoors use
N/en 5.4.386.04 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12/11
26360, 80207 NAMUR
Dimensions
Valves
1
14
5 18 3
2
12
1
141
0
1
3
G1/4
1
2
71
24
ø 19,5
ø 15,5
12
ø 5,5
3
12
M5
23
3
32 5
55 7 30 5
14
5 18 3
2
14
1
153
0
1
G1/4
3
2
24
ø 19,5
ø 15,5
12
ø 5,5
1
12
M5
24
4
35
35
1 Manual override without detent
5
2 Manual override with detent
32 5 3 Solenoid 4 x 90° turnable
55 7 30 5
12/11 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en 5.4.386.05
26360, 80207 NAMUR
14
3 5 18 3
14
2
1
0
1
3
G1/4
5
2
24
ø 19,5
ø 15,5
102
12
ø 5,5
1
242
12
M5
24
4
3
51
12
32 5
55 7 30 5
5 18
4 3
2
14
132
1
0
3
G1/4
5
2
24
ø 19,5
ø 15,5
124
12
ø 5,5
~ 264
1
12
M5
24
4
3
62
1 Manual override without detent
2 Manual override with detent
32 5
55 7 30 5 3 Solenoid 4 x 90° turnable
N/en 5.4.386.06 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12/11
26360, 80207 NAMUR
Dimensions
Solenoid operators
1 71 1
38
15,5
40,5
41,5
M16 X 1,5 12
29,5
28
18
2
5 6 107
40,5
64,5
91,5
27
41
82,5 M 20 x 1,5
89 42
54,5
33
19,5
63,5
73
7 70,5 2
8
1/2 - 14 NPT
41,5
40,5
20
3 59 84
63 2
33,5
43
56
26 4
29 43
122
1 Connector can be indexed by 4x90°
2 Ø 16 or 13 (with spacer tube)
3 M20 x 1,5 or 1/2 - 14 NPT
4 Flying leads AWG 18 (450 mm long)
12/11 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en 5.4.386.07
26360, 80207 NAMUR
Circuit diagrams
1 4 5 6
NAMUR hole pattern (driving side)
32
M5 4
2
24
2 3
3
NAMUR quick exhaust module for a better
2 Port 2 (A)
kv-value by exhaust see data sheet 5.4.820
3 Coding stud threaded
NAMUR interlinking plates in redundancy design
for »safety exhausting« and »safety ventilating« 4 M5 (10 deep)
see data sheet 5.4.830 5 Port 3 (R)
N/en 5.4.386.08 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12/11
26360, 80207 NAMUR
Single connection plate NAMUR slot
Type: 0612790 Type: 0612791
19 25,5 M 5 (4x)
19
25,5
G 1/4
35
19
41
16
51
11,5
30
9,5
16
12 12 5,5
34,5 41
104
5,5
ø 9,5 19
ø 5,5 G 1/4
12
5
11
60°
29
19
12
10
ø9 27 21
ø 14,5
Yoke Throttle control plate
Type: 0540593 Model: 4040239
19,5
2x
15,5
65
45
32
M5
50
41
12
12
5 20
76 4
12
8
25
M5
7,5
B B
15,5
15,5
A A
12/11 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en 5.4.386.09
26360, 80207 NAMUR
Silencer Exhaust guard
Model: M/S2, C/S2 Model: 0613422
42,5 26,5
8 10
ø 15,5
1/4”
1/4”
ø 21
Cable gland
C C
B D B D
A
0588925 only
A B C øD Model
M20 x 1,5 9 36 5 ... 8 22 0588819
M20 x 1,5 14 39 10 ... 14 24 0588851
1/2-14 NPT 15 58 7,5 ... 11,9 24 0588925
Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes
systems only. Do not use these products where pressures and of all component parts used in pneumatic systems and to provide
temperatures can exceed those listed under »Technical features«. adequate safeguards to prevent personal injury or damage to
equipment in the event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in
for non-industrial applications, life-support systems, or other ap- the system instructional manual if protection against
plications not within published specifications, consult NORGREN. a failure mode cannot be adequately provided.
System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in warnings found in instruction sheets packed and shipped with
fluid power systems can fail in various modes. these products.
N/en 5.4.386.10 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12/11