GE Power
Christian BAUER
                                                                                                                                     Service Engineering
                                                                                                                                     Distributed Power
                                                                                                                                     GE Jenbacher GmbH & Co OG
  Distribution list                                                                                                                  Achenseestr. 1-3
  Jenbach, Subsidiaries, Service Providers                                                                                           A-6200 Jenbach, Austria
                                                                                                                                     T +43 5244 600 2399
                                                                                                                                     [email protected]
  Service Technician Instruction                                                                              ST-156                 14 March 2017
Engine type                              All
Subject                                  Compatibility between DIA.NE WIN and DIA.NE XT
                                         Importing parameters via DIA.NE WIN
The Service Technician Instruction ST-156 describes which versions of DIA.NE WIN and DIA.NE XT are mutually
compatible and what risks an incorrect combination, particularly in the case of a parameter import via DIA.NE
WIN, could involve.
AFFECTED ENGINES / SCOPE OF THIS BULLETIN
ST-156 is relevant to all systems equipped with DIA.NE WIN (WIN server). It is important that you always read this
instruction carefully before each parameter import via DIA.NE WIN.
DESCRIPTION OF THE CONTENT
Where DIA.NE WIN is used on a system (e.g. for a parameter import), the version of DIA.NE WIN must be compatible
with the version of DIA.NE XT (RPS version) installed on the system. The table below is intended to clarify the required
compatibility.
            DIA.NE XT                                DIA.NE WIN                             DIA.NE WIN                            DIA.NE WIN                            DIA.NE WIN
          (RPS VERSION)                               IPC5000                             APC620 CELERON                         APC620 ATOM                          APC910 CELERON
                 2.07                                     1.0.x                                   ≥ 2.2.0                             ≥ 4.2.0                                 ≥ 5.5.1
                 2.10                                     1.1.x                                   ≥ 2.1.0                             ≥ 4.2.0                                 ≥ 5.5.1
                 2.20                                      ---                                    ≥ 2.2.0                             ≥ 4.2.0                                 ≥ 5.5.1
                 2.30                                      ---                                    ≥ 2.3.0                             ≥ 4.2.0                                 ≥ 5.5.1
                 2.50                                      ---                                    ≥ 2.5.0                             ≥ 4.2.0                                 ≥ 5.5.1
                 2.60                                      ---                                    ≥ 2.6.0                             ≥ 4.2.0                                 ≥ 5.5.1
                 3.10                                      ---                                    ≥ 3.1.0                             ≥ 4.2.0                                 ≥ 5.5.1
                 3.20                                      ---                                    ≥ 3.2.0                             ≥ 4.2.0                                 ≥ 5.5.1
                 3.30                                      ---                                       ---                              ≥ 4.3.0                                 ≥ 5.5.1
                 3.40                                      ---                                       ---                              ≥ 4.4.0                                 ≥ 5.5.1
                 3.50                                      ---                                       ---                              ≥ 4.5.0                                 ≥ 5.5.1
Table 01: Compatibility between DIA.NE WIN and DIA.NE XT
NOTE: Explanations of the terms used (DIA.NE XT, DIA.NE WIN) and server types (IPC5000, APC620 Celeron, APC620 Atom, APC910 Celeron) are
provided at the end of this bulletin.
                                                                                     GE PROPRIETARY INFORMATION
  The information contained in this document is General Electric Company proprietary information and is disclosed in confidence. It is the property of GE and may not be used, disclosed to
  others or reproduced without the express written consent of GE. This includes, but is not limited to, use of the information to create, manufacture, develop or derive any repairs, modifications,
  spare parts, designs or configuration changes, or to obtain government or regulatory approval to do so. If consent is given for reproduction in whole or in part, this notice and the notice set
  out on each page of this document shall appear in any such reproduction in whole or in part.
ST-156_EN.docx                                                                                    Index: 02                                                                                      1/6
GE proprietary information: CONFIDENTIAL                                                                                                      Uncontrolled when printed or transmitted electronically
Use or disclosure of data contained on this sheet is subject to the restrictions on the cover or on the first page.
                                                                                                                           SERVICE TECHNICIAN INSTRUCTION ST-156
                                                                                                                      Compatibility between DIA.NE WIN and DIA.NE XT
                                                                                                                                 Importing parameters via DIA.NE WIN
Staff at Plant Scheduling ensure that the versions of DIA.NE WIN and DIA.NE XT used are mutually compatible and the
system is properly configured when it leaves the factory. If, however, the DIA.NE XT version (RPS version) on an engine
is changed, a new engine is integrated into an existing system with an existing DIA.NE WIN server or a WIN server is
used to import parameters on any system, there is a risk that the DIA.NE WIN/XT configuration will be incompatible.
This gives rise to the danger of an incomplete or incorrect parameter import and potentially serious consequential
damage.
PARAMETER IMPORT VIA DIA.NE WIN IN THE CASE OF AN INCOMPATIBLE DIA.NE WIN/XT CONFIGURATION
This section is intended to show the progress and the consequences of a parameter import via DIA.NE WIN when, for
example, one of the WIN versions 3.2.0, 3.2.1, 3.2.2 (server APC620 Celeron) or 4.2.0, 4.2.1, 4.2.2 (server APC620 Atom)
is used on a system with a DIA.NE XT version (RPS version) from 3.30 (i.e. 3.30 or higher).
NOTE: As can be seen from the table at the beginning of this bulletin, only the DIA.NE WIN servers APC620 Atom with a WIN version from 4.3.0
onwards or APC910 Celeron with a WIN version from 5.5.1 onwards would be permitted in the case of a system with a DIA.NE XT version (RPS
version) from 3.30 onwards.
 The system highlights the fact that parameters are missing.
     Fig. 01: Missing parameters
ST-156_EN.docx                                                                                    Index: 02                                                                      2/6
GE proprietary information: CONFIDENTIAL                                                                                      Uncontrolled when printed or transmitted electronically
Use or disclosure of data contained on this sheet is subject to the restrictions on the cover or on the first page.
                                                                                                                           SERVICE TECHNICIAN INSTRUCTION ST-156
                                                                                                                      Compatibility between DIA.NE WIN and DIA.NE XT
                                                                                                                                 Importing parameters via DIA.NE WIN
 Once again, the system highlights the fact that the parameter import is incomplete.
     Fig. 02: Incomplete parameter import
 CAUTION: This parameter import would not only be incomplete, it would also be incorrect. For example,
  DIA.NE WIN versions 3.2.0, 3.2.1, 3.2.2 (server APC620 Celeron) and 4.2.0, 4.2.1, 4.2.2 (server APC620 Atom)
  overwrite some parameters of DIA.NE XT versions (RPS versions) from 3.30 (i.e. 3.30 or higher) INCORRECTLY.
  The import would for example result in incorrect knock limits and therefore an almost completely inactive
  knock monitoring system, giving rise to the danger of serious engine damage. You should therefore never
  allow yourself to be misled into thinking that if you manually add those parameters which the system
  highlights as missing, the process will be concluded (fully and correctly).
CONCLUSION
A parameter import via DIA.NE WIN is only permitted when the versions of DIA.NE WIN and DIA.NE XT are
mutually compatible as shown in the table at the beginning of this bulletin!!!
ST-156_EN.docx                                                                                    Index: 02                                                                      3/6
GE proprietary information: CONFIDENTIAL                                                                                      Uncontrolled when printed or transmitted electronically
Use or disclosure of data contained on this sheet is subject to the restrictions on the cover or on the first page.
                                                                                                                                 SERVICE TECHNICIAN INSTRUCTION ST-156
                                                                                                                            Compatibility between DIA.NE WIN and DIA.NE XT
                                                                                                                                       Importing parameters via DIA.NE WIN
DETERMINING THE DIA.NE XT AND DIA.NE WIN VERSIONS/VERSION NUMBERS
The illustration below shows how to check the versions/version numbers of DIA.NE WIN and DIA.NE XT (menu 'System'
>> submenu 'System data').
                                                                                                           CAUTION: This illustration shows an
                                                                                                           INcompatible DIA.NE WIN/XT configuration!
     Fig. 03: DIA.NE WIN and DIA.NE XT versions used
     NOTE
     DIA.NE XT:              The deciding factor is the line DIA.NE XT – RPS. An example with XT version 3.3 can be seen above.
     DIA.NE WIN:             The deciding factor is the line DIA.NE WIN – DEF. An example with WIN version 4.2.2 can be seen above.
     The illustration above therefore shows an incompatible DIA.NE WIN/XT configuration. As can be seen from the table at the beginning of this
     bulletin, only the DIA.NE WIN servers APC620 Atom with a WIN version from 4.3.0 onwards or APC910 Celeron with a WIN version from 5.5.1
     onwards would be permitted in the case of a system with a DIA.NE XT version (RPS version) from 3.30 onwards.
WHAT TO DO WHEN A DIA.NE WIN/XT CONFIGURATION IS INCOMPATIBLE
Before every parameter import via DIA.NE WIN you must ensure that the DIA.NE WIN version used is compatible with
the DIA.NE XT version (RPS version) installed on the system. If necessary, upgrade DIA.NE WIN.
 DIA.NE WIN upgrade by GE employee (Jenbach, subsidiaries)
  The hard drive on the DIA.NE WIN server can be upgraded from a flash card by an IT Manager (Excellence Centre).
 DIA.NE WIN upgrade by NON-GE employee (service providers)
  The hard drive on the DIA.NE WIN server has to be replaced.
ST-156_EN.docx                                                                                    Index: 02                                                                             4/6
GE proprietary information: CONFIDENTIAL                                                                                             Uncontrolled when printed or transmitted electronically
Use or disclosure of data contained on this sheet is subject to the restrictions on the cover or on the first page.
                                                                                                                                   SERVICE TECHNICIAN INSTRUCTION ST-156
                                                                                                                              Compatibility between DIA.NE WIN and DIA.NE XT
                                                                                                                                         Importing parameters via DIA.NE WIN
EXPLANATION OF TERMS
Below are brief explanations of the terms used in this ST-156.
 DIA.NE XT
  Engine management system for all types of Jenbacher gas engines. It consists of a control unit, which includes a
  visualisation unit, in a single device. DIA.NE XT exists in a variety of versions and with different software version
  numbers (RPS versions).
     Fig. 04: DIA.NE XT (RPS versions 2.07 - 2.60)                                                         Fig. 05: DIA.NE XT3 (RPS versions 3.10 - 3.50)
 DIA.NE WIN
  A "Human-Machine Interface" based on the Windows operating system for Jenbacher gas engines. It offers both
  customers and Jenbacher maintenance staff a wide range of facilities that assist in the commissioning, on-going
  servicing, monitoring and maintenance of engines and for diagnostic purposes.
     4 different DIA.NE WIN servers are used in the field:
     o IPC5000                     …with software versions 1.0.0 - 1.1.x
     o APC620 CELERON              …with software versions 2.1.0 - 3.2.x
     o APC620 ATOM                 …with software versions 4.2.0 - 4.5.x
     o APC910 CELERON              …with software versions from 5.5.1 onwards
     Fig. 06: DIA.NE WIN – IPC5000
ST-156_EN.docx                                                                                    Index: 02                                                                                5/6
GE proprietary information: CONFIDENTIAL                                                                                                Uncontrolled when printed or transmitted electronically
Use or disclosure of data contained on this sheet is subject to the restrictions on the cover or on the first page.
                                                                                                                            SERVICE TECHNICIAN INSTRUCTION ST-156
                                                                                                                       Compatibility between DIA.NE WIN and DIA.NE XT
                                                                                                                                  Importing parameters via DIA.NE WIN
                                                                                        How to tell Celeron and Atom apart:
                                                                                        The Atom variant of the DIA.NE WIN
                                                                                        server APC620 can be identified by a
                                                                                        sticker below the orange cover. The
                                                                                        Celeron does not have a sticker.
      Fig. 07: DIA.NE WIN – APC620 Celeron/Atom
      Fig. 08: DIA.NE WIN – APC910 Celeron
RELEVANT DOCUMENTS
When working on GE Jenbacher modules, all applicable local regulations must of course be observed in addition to
our documentation. In relation to this Service Technician Instruction we stress the fact that the following documents
must also be observed:
 DIA.NE WIN User Manual
 DIA.NE XT User Manual
REVISION CODE
 INDEX             DATE                         DESCRIPTION / REVISION SUMMARY
 02                Mar. 14, 2017                DIA.NE WIN server APC910 Celeron added
 01                Jun. 18, 2014                First version of this document
Table 02: Revision history