Chapter Contents
This chapter addresses the architecture and components of Cisco Catalyst 6500 Series
Virtual Switching System (VSS) 1440. Although this design guide focuses on the
deployment specifics of the VSS (and not technology itself), sufficient detail is included for
all the necessary components of the VSS that can affect campus design. This includes
operational characteristics, design tradeoffs, and best-practice configuration
recommendations. For further details about VSS technology, refer to the following
document:
Cisco Catalyst 6500 Series Virtual Switching System (VSS) 1440 White Paper on VSS
technology:
http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps9336/white_paper_c11_429
338.pdf
The VSS forms two Cisco Catalyst 6500 switches into a single, logical network entity. Two
chassis combine to form a single virtual switch domain that interacts with rest of the network
as single logical switch and/or router. See Figure 2-1.
The VSS domain consists of two supervisors—one in each member chassis connected via
a Virtual Switch Link (VSL). A VSL facilitates the communication between two switches.
5
Within the VSS, one chassis supervisor is designated as active and the other as hot-
standby. Both use Stateful Switch Over (SSO) technology. The switch containing the active
supervisor is called active switch and the switch containing hot-standby supervisor is called
hot-standby switch. VSS operates on a unified control plane with a distributed forwarding
architecture in which the active supervisor (or switch) is responsible for actively participating
with the rest of the network and for managing and maintaining control plane information.
The active switch maintains and updates the hot-standby supervisor with up-to-date
information about the states of the system and network protocols via the VSL. If the active
supervisor fails, the hot-standby supervisor assumes the active roles in managing the
control plane. Both physical chassis do the data forwarding and data forwarding is done in a
distributed manner. The devices adjacent to the VSS are connected via a Multichassis
EtherChannel (MEC) to form a single logical connection. The single logical switch, in
combination with the MEC, forms the foundation of a highly available, loop-free topology.
The rest of this section details the operation and best-practice configuration for components
of the VSS that influence the deployment of a VSS in the campus distribution block. This
design guide does not provide detailed step-by-step instructions about transitioning an
existing network to a VSS-based environment, nor does it cover all preparatory work;
however, it does cover essential steps that can affect the deployment of a VSS in the
campus.
Virtual Domain
Defining the domain identifier (ID) is the first step in creating a VSS from two physical
chassis. A unique domain ID identifies two switches that are intended to be part of the same
VSS pair that defines the VSS domain. Assignment of a domain ID allows multiple virtual
switch pairs to be connected in a hierarchical manner. Only one VSS pair can participate in
a particular domain. The domain ID can have a value ranging from 1 to 255 and must be
unique when multiple VSS pairs are connected together. See Figure 2-2.
The domain ID is defined in both physical switches as shown in the following examples.
Standalone Switch 1:
VSS-SW1# config t
6
VSS-SW1(config)# switch virtual domain 10
Standalone Switch 2:
VSS-SW2# config t
The use of a domain ID is important for networks in which VSS is deployed at multiple
layers in a manner as shown in Figure 2-2. This unique ID is used in many different protocol
and systems configurations—such as virtual Media Access Control (MAC), Port
Aggregation Protocol (PAgP), and Link Aggregate Control Protocol (LACP) control packets.
If two connected VSS domains contain the same domain ID, the conflict will affect VSS
operation.
The following command output example illustrates the domain ID used in the LACP system
ID. The last octet—0a (hex)— is derived from the domain ID of 10 (decimal).
32768,0200.0000.000a <--
Tip The recommendation is to use a unique domain ID as a best practice, even when you
are not connecting multiple VSS domains together.
Switch Identifier
A VSS comprises of pair of physical switches and requires a switch ID to identify each
chassis with a unique number. The switch ID can be either 1 or 2 and must be unique on
each member chassis. This number is used as part of the interface naming to ensure that
the interface name remains the same regardless of the virtual switch role (active or hot-
standby switch). Usually the switch ID should be set in configuration mode as shown in the
following examples.
7
Standalone Switch 1:
VSS-SW1# config t
VSS-SW1(config-vs-domain)# switch 1
Standalone Switch 2:
VSS-SW2# config t
VSS-SW2(config-vs-domain)# switch 2
However, when a hardware problem on one supervisor prompts the adoption of a new
supervisor, you can set the switch ID via the command-line interface (CLI) in enable mode
as shown in the following configuration examples.
Standalone Switch 1:
Standalone Switch 2:
Both methods write the switch identifier in each member chassis ROMMON. The domain ID
and switch number via following can be shown via the following CLI example.
Caution Avoid using the command write erase to copy a new startup configuration. This
command will erase switch numbers stored in ROMMON and any subsequent reboot will
cause both switches to come up in standalone mode. Use the switch set switch_num 1/2
command only after both switches are rebooted because the CLI to set the switch number
is not available in VSS mode.
The VSS is made of two physical chassis combined to form a single logical entity. This
unification of the control plane is only possible if the system controls, signaling, and
backplane exist as a single entity in both chassis. This extension of the system control
plane is achieved via a special purpose EtherChannel bundle. The link belonging to
EtherChannel is called Virtual Switch Link (VSL). The VSL serves as logical connection that
carries critical system control information such as hot-standby supervisor programming, line
card status, Distributed Forwarding Card (DFC) card programming, system management,
diagnostics, and more. In addition, VSL is also capable of carrying user data traffic when
necessary. Thus, the VSL has a dual purpose, supporting system control synchronization
and a data link.
The VSL link is treated as a systems control link and encapsulates all traffic into a special
system header called the Virtual Switch Header (VSH). This encapsulation is done via
dedicated hardware resources and the VSL can only be configured on a 10-Gigabit
interface with following hardware ports:
•WS-X6708
9
The size of the VSH is the same as that of the internal compact header used by the Cisco
Catalyst 6500—it is 32 bytes long. This header is placed after the Ethernet preamble and
directly before the Layer-2 header. See Figure 2-3.
The VSS features a single control plane with a distributed forwarding architecture (see the
"Stateful Switch Over Technology" section). Although only one supervisor manages the
control plane, both switches participate in learning the control plane information. Any
network and system control plane information learned via the hot-standby switch is sent to
the active supervisor which in turn updates the hot-standby supervisor. This bidirectional
process of learning and updating between switches is carried out over the VSL link.
The VSL is an integral component of the VSS because it is the only path through which the
two independent systems can become aware of each other during system initialization. This
mutual awareness during system initialization is needed to determine the respective role of
each physical chassis in becoming either the active or hot-standby virtual switch. For this
reason, VSL links are brought up very early in the boot up process—before any other major
service or component. To accomplish this task, each switch stores the switch number and
other information necessary in ROMMON to activate the VSL link and associated line card
booting sequence. During the VSL initialization, the system undergoes a variety of
compatibility checks required to form a virtual switch. The VSS requires identical supervisor
types and Cisco IOS software versions on both chassis. Please refer to the applicable
release note for additional system requirements needed to form a virtual switch. VSL link
initialization and maintenance are done through the VSL Protocol (VSLP) framework, which
consists of two protocols: Link Management Protocol (LMP) and Role Resolution Protocol
(RRP). LMP manages link integrity, while RRP determines the role of each switch member
in the virtual switch domain. RRP is covered under "Stateful Switch Over Technology"
section.
LMP is the first protocol to be initialized, once the VLS line card diagnostics is finished and
VSL link comes on line. See Figure 2-4. The LMP is designed to perform following critical
functions:
10
•Establishing and verifying bidirectional communications during startup and normal
operation.
•Independently transmitting and receiving LMP hello timers to monitor the health of the VSL
and peer switch.
LMP operates independently on each member switch in the same Virtual Switch Domain
(VSD). Unlike other protocols—such as PAgP, LACP and Interior Gateway Protocol (IGP)
hello—that use a single control plane over which the active switch originates and terminates
the protocol, both switches in the VSD independently originate and terminate LMP control-
plane packets on the Switch Processor (SP). See the dotted-red circle highlighting in Figure
2-5. LMP is designed to run on each VSL member link to maintain multiple state machines
with the same peer over different ports. In a case in which a unidirectional condition on a
port is detected, LMP marks it as down and attempts to restart VSLP negotiation—instead
of err-disabling the port. On each member switch of a VSD, LMP internally forms a single
unique peer group (PG) ID with a common set of VSL links. When all VSL interfaces are
down, LMP destroys the peer group and notifies RRP to take an appropriate action. The
active switch will detach all the interfaces associated with the hot-standby switch. At the
same time the hot-standby switch performs switchover, assumes the active role, and
detaches all interfaces associated with the previously active switch.
LMP hello packets are Logical Link Control (LLC)/ Sub-network Access Protocol (SNAP)-
encapsulated with the destination MAC address matching the Cisco Discovery Protocol
(CDP)—01.00.0C.CC.CC.CC. All inter-chassis control plane traffic, including LMP and hello
packets, are classified as bridge protocol data unit (BDPU) packets and are automatically
placed in transmit priority queue.
11
Control Link and Inter-Chassis Control Plane
The VSL bundle is special purpose EtherChannel that can have up to eight members. Only
one link out of a configured member is selected as the control link and that control link is the
only link that can carry the inter-chassis control plane. The control link carries the inter-
switch External Out-of-Band Channel (EOBC) control traffic that includes the Switch Control
Packet (SCP) for line card communication, Inter-process Communication Packets (IPC),
and Inter-Card Communication (ICC) for communicating the protocol database and state—
as well as updates to the hot-standby supervisor. In addition, the same link can carry user
and other network control traffic—depending how the traffic is hashed (based on source and
destination MAC and/or IP addresses). The remaining bundled links carry network control
plane and user data traffic, but not the inter-chassis control plane traffic (see the "Traffic
Prioritization and Load-sharing with VSL" section). The control link is shown in Figure 2-4
The control-link selection procedure is determined by the VSS system and cannot be
managed by the user. During the bootup process, the first VSL link that establishes LMP
relationship (state-machine) will be selected as the control link. Based on the Cisco Catalyst
6500 architecture, the supervisor module becomes operational ahead of any other module
installed in the switch. If the 10-Gbps port of Sup720-10G module is bundled in the VSL
EtherChannel, then it will be selected as control-link interface whenever both switches
undergo the boot process.
The show vslp lmp neighbor command output illustrated in Figure 2-6 depicts the current
control link interface (see the dotted red circle) and list of backup VSL interfaces (which can
be used if the current control-link path fails). Backup interfaces are member links of the local
virtual switch's VSL EtherChannel. For a highly redundant VSL network design, the VSL
EtherChannel must be bundled with multiple, VSL-capable 10-Gbps ports between the
switch members. In such a case, the first listed interface under the Interfaces column of the
show vslp lmp neighbor command will immediately become control link interface if the
current control link interface fails. When the 10-Gbps port of a Sup720-10G module is
restored and rejoins the VSL EtherChannel, it will be placed as the next available control-
link backup path without affecting the current control link interface (see second part of the
output illustrated Figure 2-6 after control link is brought back up).
12
The LMP heart beat—also referred as the LMP hello timer—plays a key role in maintaining
the integrity of VSS by checking peer switch availability and connectivity. Both VSS
members execute independent, deterministic SSO switchover actions if they fail to detect
the LMP hello message within configured hold-timer settings on the last bundled VSL link.
The set of LMP timers are used in combination to determine the interval of the hello
transmission applied to maintain the healthy status of the VSL links. The three timers are as
follows:
Figure 2-7 illustrates an example CLI output depicting the timer values per VSL link
member.
By default, the LMP hello transmit timer (T4) and receive timer (min_rx) are assigned values
of 500 msec each. The hold-timer (T5 timer) is derived from a min_rx and default multiplier
of 120 (the CLI does not show the default multiplier). By default, a VSL member link time
out is detected in 60,000 msec (60 seconds). The expiration of T5 indicates possible
instability on the remote peer (active or hot-standby switch). Each switch member will take
an independent action if the T5 timer expires. These actions include (but are not limited to)
the following:
•If expiration occurs on a VSL port that is the control link, then the switch that detected the
problem will force the new control link selection. It is entirely possible that T5 timer would
have not yet expired on the remote peer; however, the remote peer switch will respect the
request and reprogram internal logic to send control plane traffic to the newly elected VSL
port as the control link port.
13
•If expiration occurs on a non-control link port, the switch that detected the failure selects an
available port for user data traffic. Eventually, the remote peer detects a change and
removes the link from the bundle.
•If expiration occurs on the last VSL port (a combination control link and user data port) and
the timeout is detected on the active switch, then the active switch removes all the peer
switch interfaces and announces the change to rest of the network—depending on the
configuration on those interface (Layer-2 or Layer-3 protocol). Eventually, the peer switch
that is in hot-standby mode will detect the T5 timer expiration and LMP will inform RRP,
which forces the hot-standby switch to become the active switch. This triggers a condition
known as dual active in which both switches declare active roles leading to instability in the
network (refer to the "Campus Recovery with VSS Dual-Active Supervisors" section on
page 4-18 for information about avoiding such conditions).
The LMP timer is used primarily for ensuring the integrity of VSS (during high CPU usage or
abnormal software behavior). Normal hardware failure detection or switchover (user or
system initiated) is invoked via the hardware mechanism known as Fast Link Notification
(FLN). When an applicable event occurs, FLN informs the firmware of WS-X6708 or
Sup720-10G ports to take any necessary action—typically within 50 to 100 msec. FLN is
not designed to detect the failure of the remote switch. In most cases, modifying the default
LMP timer to a shorter value does not improve convergence. This is because inter-chassis
control plane protocol timer (IPC timer) expires before LMP timers and thus supersede the
action taken.
Unintended effects can result when VSLP timers are aggressively modified. For example,
modifying the VSLP timer to a lower value will add significant instability. An example
scenario description follows:
When configured with a lower VSLP timer value, the VSL will typically fail to establish
neighbor relationships between member switches—leading to continuous rebooting (a crash
in Cisco IOS parlance) of the switch. During the boot up process, the VSS switch must
process multiple high-priority activities. When enabled with an aggressive VSLP timer, each
member might be unable to maintain the VSLP session due to the lack of resources. When
LMP hello times out on either side, LMP removes the VSL member link from VSL
EtherChannel. Eventually, all links between the active and hot-standby switches can fail.
For the hot-standby switch, this is considered a catastrophic error and the only way to
recover is to immediately send a reset signal (crash) and start over. This can continue until
at least one LMP session is established and thus can cause significant network instability.
14
In addition, a VSS member might also fail to send or receive LMP hello message within a
configured T5 timer limit due to VSL link congestion or high CPU utilization. In such
situations, the VSS system will become unstable, which can lead to a dual-active condition.
Tip Cisco strongly recommends that you do not modify the default LMP (VSLP) timers.
RRP is responsible for determining the operational status of each VSS switch member.
Based on the configured parameter, a member switch can assume a role of the active, hot
standby, or Route Process Redundancy (RPR). The RRP provides checks for Cisco IOS
software compatibility. If the software versions are not compatible, RRP forces one of the
switches into RPR mode and all line cards are powered off. The "Virtual Switch Role,
Priorities and Switch Preemption" section provides details of the RRP because its
application is more relevant to chassis redundancy and SSO operation.
Configuring VSL is the second step in creating a virtual switch (after defining the domain
ID). The VSL bundle is a special-purpose port channel. Each standalone switch is required
to be configured with unique port-channel interface numbers; before assigning a port-
channel number, you must make sure that the port-channel interface number is not used by
an existing standalone configuration on either switch. The following configuration steps are
required in each switch to convert the standalone switch to a VSS. The detailed conversion
process is beyond the scope of this document. For addressing VSS conversion, refer to the
Migrate Standalone Cisco Catalyst 6500 Switch to Cisco Catalyst 6500 Virtual Switching
System document at the following URL:
http://www.cisco.com/en/US/products/ps9336/products_tech_note09186a0080a7c74c.shtml
Standalone Switch 1:
15
VSS-SW1(config-if)# interface range Ten5/4 - 5
Standalone Switch 2:
Since VSL EtherChannel uses LMP per member link, the link-aggregation protocols, such
as PAgP and LACP, are not required; each member link must be configured in
unconditional EtherChannel mode using the channel-group group-number mode on
command. Once the VSL configuration is completed, using the switch convert mode virtual
CLI command at the enable prompt will start the conversion process. The conversion
process includes changing the interface naming convention from slot/interface to
switch_number/slot/interface, saving the configuration, and rebooting. During switch
rebooting, the systems recognize the VSL configuration and proceeds with their respective
VSL ports initialization processes. The two switches communicate with each other and
determine which will have active and hot-standby roles. This exchange of information is
evident through the following console messages:
configuration...
Interface TenGigabitEthernet
Interface TenGigabitEthernet
Interface TenGigabitEthernet
Interface TenGigabitEthernet
<snip>
A first-time VSS conversion requires that you must execute the following command as the
final step of accepting the virtual mode operation of the combined switches. If the switch
has been converted, or partially converted, you cannot use this command.
The preceding command forces the integration of all VSL-link related configurations from
the hot-standby switch and populates the running configuration with those commands. In
addition, the startup configurations are updated with the new merged configurations. The
following prompt appears:
Building configuration...
[OK]
17
Note Only VSL-related configurations are merged with the conversion step. All other
configurations must be managed per your network site implementation requirements. Follow
the related Cisco product documentation for further details.
VSL Characteristics
The VSL port channel is treated as an internal systems link. As a result, its configuration,
resiliency, mode of operation, quality of service (QoS), and traffic load sharing follow a set
of rules that are specific to VSL. This section covers configuration requirements relating to
those rules. The logical port channel and its member link both have distinct sets of
restrictions.
6500-VSS(config)# int po 1
6500-VSS(config-if)# ?
18
VSL member links are in restricted configuration mode once the VSL configuration is
applied. All Cisco IOS configuration options are disabled except following:
•EtherChannel
•Netflow configuration
6500-VSS(config-if)# ?
19
When configuring VSL interfaces, only one VSL EtherChannel configuration per virtual-
switch is possible. Configuring an additional VSL EtherChannel will result in an error. The
following are examples of error messages generated:
% Can not configure this as switch 1 VSL Portchannel since it already had VSL Portchannel
1 configured
6500-VSS(config-if)#
% Can not configure this as switch 2 VSL Portchannel since it already had VSL Portchannel
2 configured
In addition, for post VSS conversion, a neighbor switch port cannot be bundled into the local
switch's VSL EtherChannel. In the example used here, the Switch 1 VSL EtherChannel
cannot bundle a physical port from Switch 2. However, a regular EtherChannel does not
have such a restriction. The following example output illustrates the error message
generated when attempting to configure this unsupported mode:
VSL bundle across chassis not allowed TenGigabitEthernet2/5/5 is not added to port
channel
The remainder of this section covers design considerations for prioritizing traffic over VSL
links, resiliency, and traffic load-sharing options available with VSL.
20
approach for classifying user traffic at the edge and using those priorities intelligently via the
Differentiated Services Code Point (DSCP) trust model. This design guide does not cover
generic QoS requirements and behavior in VSS; however, this section does address QoS
as it applies to a VSL link in terms of default behavior, how the control plane is protected,
and implementation options that network designers should consider.
http://www.cisco.com/en/US/docs/solutions/Enterprise/WAN_and_MAN/QoS_SRND_40/Qo
SCampus_40.html
Due to the ease of configuration, flexibility, and bandwidth requirement, the distribution layer
traditionally leverages line cards for connectivity to the core and access layer, thus the use
of supervisor ports is limited. The access layer uses the uplink from either a supervisor or a
dedicated port on non-modular switches. The Sup720-10G supervisor offers a new option of
using the 10-Gbps port available on the supervisor to provide uplink connectivity to the core.
This requires an understanding of the current design choices with the Sup720-10G uplink
port with respect to QoS when used as the VSL port and/or uplink to the rest of the network.
The VSL link can only be configured on 10-Gbps ports. Choosing the VSL link configuration
on either a supervisor port or line card affects the QoS capability on the unused ports of the
supervisor. The Sup720-10G supervisor has two 10-Gbps ports and three 1-Gbps ports.
The Sup720-10G uplink ports can be configured in one of two modes:
In this mode, all ports must follow a single queuing mode. If any 10-Gbps port is used for
the VSL link, the remaining ports (10 Gbps or 1Gbps) follow the same CoS-mode of
queuing for any other non-VSL connectivity because VSL only allows class of service
(CoS)-based queuing.
In this mode all 1-Gbps ports are disabled, as the entire module operates in a non-blocking
mode. Even if only one 10G port used as VSL link, still both 10-Gbps port is restricted to
CoS-based trust model. 12.2(33)SXI removes this limitation by allowing the unused (non-
VSL configured)10-Gbps port be configured based on user preference, including DSCP-
based queuing.
21
Figure 2-8 shows that a 10-Gbps-only mode increases transmit queue from default 1p3q4t
to the 1p7q4t setting. It also increases the receive queue size from 2p4t to 8q4t similar to
the WS-X6708 module. However, the default Tx and Rx queue mapping remains CoS-
based with or without 10-Gbps-only mode. As a result, there is no real benefit to using an
improved queue structure to map each class of traffic in separate queues because the
default COS-to-queue mapping cannot be changed.
If one of the WS-X6708 line card port is used as the VSL link, port queuing for that port is
limited to being CoS-based; however, the remaining ports can have independent sets of
QoS configuration.
The resilient VSL design uses these facts as a design factor. Table 2-1 summarizes the
options and restrictions for Sup720-10G uplink ports. The "Resilient VSL Design
Consideration" section describes incorporating these design factors when developing highly
resilient and flexible VSL configurations.
10g-only mode
Queue Structure
Tx- 1p7q4t
Rx - 8q4t
Tx -1p3q4t
22
Rx - 2q4t
Or
Both 10-Gbps ports can have independent sets of QoS configuration including trust model
and queuing mode.
All ports are available. All uplinks can only use a single QoS configuration (maps,
thresholds, and queues).
If both 10-Gbps ports are used as the VSL link, only CoS-based trust mode supported.
Even if only a single 10-Gbps port is used as the VSL link, both 10-Gbps ports are restricted
to the CoS-based trust model in Cisco IOS 12.2(33) SXH. Cisco IOS 12.2(33) SXI removes
23
this limitation by allowing the remaining 10-Gbps port to be configured based on user
preference, including DSCP-based queuing.
Both 10-Gbps ports are used or a single 10- Gbps port is used as the VSL uplink; you can
only define one QoS configuration. Because VSL only allows CoS-based queuing, the
remaining non-VSL ports follow the COS-based queuing for any non-VSL connectivity.
The VSL (by default) uses a CoS-based trust model. This default CoS-trust setting on VSL
EtherChannel cannot be modified or removed. Regardless of the QoS configuration in
global mode, the VSL EtherChannel is set to CoS-based queuing mode. Figure 2-9 shows
the QoS configuration of VSL link on SW1 and SW2. As with a standalone switch, the VSS
uses the internal CoS-based queuing with various mapping tables for placing user traffic
into the egress queue. Traffic traversing the VSL link uses the same facilities with a CoS-
based trust model. The Weighted Round Robin (WRR) queuing scheduler is enabled by
default on each VSL member link. The VSL link's QoS configuration does not alter the QoS
marking set in the user traffic when that traffic traverses the VSL link.
The best-practice recommendation for VSL link resiliency is to bundle two 10-Gbps ports
from different sources. Doing this might require having one port from the supervisor and
other from a Cisco 6708 line card. By default, the Sup720-10G supervisor 10-Gbps port has
a non-Distributed Forwarding Card (DFC) 1p3q4t Tx-queue structure in contrast with the
WS-X6708 linecard which has a DFC-based 1p7q4t Tx-queue structure. For the
conventional configuration of EtherChannel, a bundle between non-congruent queue
structures would fail. However, the VSL bundle is by default enabled with the configuration
which allows the EtherChannel to be formed. This is enabled via the no mls qos channel-
consistency command.
The following QoS configuration restrictions apply once the port is bundled in the VSL
EtherChannel:
24
•The CoS-mode setting cannot be changed or removed from VSL port-channel.
•User-defined Modular QoS CLI (MQC) service-policies cannot be attached to the VSL
EtherChannel.
•Bundling of the 10-Gbps port in the VSL port-channel will fail if unsupported QoS
capabilities are preconfigured. All QoS configuration must be removed prior bundling the
port into the VSL EtherChannel.
Note The WS-X6708 module supports independent QoS policies on non-VSL configured
ports, even if one of its 10-Gbps ports is bundled in the VSL EtherChannel.
25
Prioritizing Specific Traffic Types
The VSL link can potentially carry three types of traffic and uses QoS mapping to
distinguish between each. Traffic types carried over a VSL link include the following:
•Failure of uplink from access layer to VSS causing downstream traffic to flow over the VSL
link
•Remote Switched Port Analyzer (SPAN) traffic from one VSS switch member to the other
•Service-module traffic flow from FWSM, Wireless Services Module (WiSM), Intrusion
Detection System (IDS), and other modules
VSL itself does not alter the QoS marking of user data traffic. It simply categorizes the
preceding types of traffic using the CoS-based queuing. As a result, any ingress traffic QoS
marking that is not based on CoS must use the internal QoS mapping table to provide the
26
translation to CoS-based queuing. Any end-user application traffic marked with 802.1p CoS
5, DSCP 46, or IPP 5 will be placed in the priority-queue.
The active switch always originates and terminates network control plane traffic from
participating adjacent devices. The active switch always uses a locally attached interface
(link) to forward the control plane traffic. The network control plane traffic that must traverse
the VSL due to either a failure of local links connected to active switch or traffic sourced by
a hot-standby switch, including the following:
•Layer-3 protocol traffic for Layer-3 Equal Cost Multipath (ECMP) links on the hot-standby
switch—Routing protocol control traffic, such as hello, update, database, and so on
•Traffic intended for the VSS supervisor—Internet Control Message Protocol (ICMP)
responses from other devices, time-to-live (TTL) with value of 1 in increments of hop counts
(it must terminate at the active switch), SNMP, Telnet/SSH, and so on.
All communications among VSS member switches are defined as inter-switch traffic. VSS
systems automatically classify the following inter-switch control plane protocols as Bridge
Protocol Data Unit (BPDU)-type traffic:
•Inter-Switch Communication
–Inter-Chassis Ethernet Out Band Channel (EOBC) traffic— Serial Communication Protocol
(SCP), IPC, and ICC
–Virtual Switch Link Protocol (VSLP) —LMP and RRP control-link packets
•Any Layer-2 per link protocol—Spanning Tree Protocol (STP) BPDU, Port Aggregation
Protocol (PagP)+, LACP, CDP and Unidirectional Link Detection (UDLD), Link Layer
Discovery Protocol (LLDP), Root Link Query (RLQ), Ethernet Operations, Administration,
and Maintenance (OAM), 802.1x, Dynamic Trunking Protocol (DTP), and so on.
27
These BPDU packets are automatically placed in transmit priority-queue ahead of any other
traffic
Note Network control plane traffic (Layer 2 and Layer 3) is always sent out links connected
to the active switch. It will only cross over the VSL either due to a local link being
unavailable or the protocol frame needing to be originated from the hot-standby port (e.g.
PAgP, LACP or UDLD).
Note Priority-queues are shared by the high-priority user data traffic (marked as expedited
forwarding -EF) along with control plane traffic. However, an internal mechanism always
ensures that control plane traffic takes precedence over of any other priority-queued traffic.
This ensures that user data does not inadvertently affect the operational stability of the
entire VSS domain.
As described in the preceding section, the VSL carries multiple types of the traffic over the
VSL bundle. From the traffic load-sharing perspective, the VSL bundle is just like any other
EtherChannel. It follows the same rules of EtherChannel hashing algorithm available in any
given Cisco IOS software. In standalone or virtual-switch mode, a single EtherChannel load-
balance hashing is applicable system wide. This means the VSL bundle uses the same
configured load-sharing mode that applies to all EtherChannel groups in the VSS. The
following output example illustrates load-balancing options:
28
src-dst-mac Src XOR Dst Mac Addr
Note This section only covers the characteristics of EtherChannel related to VSL. For
generic EtherChannel design and recommendation refer to the "MEC Configuration"
section.
The load-balancing method implemented applies to all network control traffic and user data
traffic. The only exceptions to this rule are inter-switch communication traffic (always carried
by control link) and LMP hello (sent on every VSL link). The network control plane and user
data traffic use source and/or destination MAC addresses and/or the IP address as input to
the hash calculation that is used to load-share the traffic. The network control plane traffic
that can be load-shared between VSL links includes, but is not limited to, the following (note
the difference in QoS categorization of the traffic):
•Layer-2 protocol traffic—Broadcast, STP BPDU, PAgP+, LACP, CDP and UDLD , LLDP,
RLQ , Ethernet OAM, 802.1x, and DTP
•Layer-3 protocol traffic for Layer-3 ECMP links on the hot standby switch—Routing protocol
control traffic (such as Hello, Update, and database) and ICMP response
•Traffic designated to VSS supervisor—ICMP response from other devices, TTL with 1, and
so on
The type of user data traffic crossing VSL links are described in the "Prioritizing Specific
Traffic Types" section section.
29
Hashing Methods—Fixed versus Adaptive
Traffic across port-channel is distributed based on Result Based Hash (RBH) computation
for each port-channel member link. Whenever a port-channel member link is added or
removed from a group, RBH must be recomputed for every link in the group. For a short
period of time, each flow will be rehashed—causing disruption for the traffic. This hash
implementation is called fixed.
As of Cisco IOS Release 12.2(33) SXH, Cisco Catalyst 6500 supports the enhanced hash
algorithm that pre-computes the hash for each port-channel member link. When the link
member fails, dynamic pre-computation of hashing allows new flows to be added to the
existing link and also reduces the loss of packets for the flows that were already hashed to
the link. This enhanced hash implementation is called adaptive. The following example
illustrates the hash-distribution options:
This command will take effect upon a member link UP/DOWN/ADDITION/DELETION event.
Tip It is recommended to keep the VSL link load-sharing hash method to default (adaptive)
as that method is more effective in recovering flows from failed links.
30
The current EtherChannel hardware can only load-share with three unique binary buckets,
thus any combination of links in the EtherChannel bundle that can fill the all the buckets
would optimally use all the links in the bundle. This translates into a number of links in the
bundle with a formula of the power of 2 for optimal load sharing.
Tip Always bundle the numbers of links in the VSL port-channels in the power of 2 (2, 4,
and 8) to optimize the traffic flow for load-sharing.
The following key factors should be considered when designing resilient VSL:
•Use port-channels with more than one member in a bundle to reduce the number of
potential single points of failure (ports, line cards)
•Use redundant hardware (ports, line cards, and internal resources connecting the port)
•Use diverse fiber paths (separate conduits, fiber terminations, and physical paths) for each
VSL links.
•Manage traffic forwarded over the VSL link to avoid single homed devices. This is covered
under the "Traffic Flow in the VSS-Enabled Campus" section on page 3-5.
31
•Since the VSL can only be configured on 10-Gbps port, choices for deploying the VSL
bundle are limited to the Sup720-10G, WS-X6708, or WS-X6716 hardware. Besides
redundancy, capacity planning also influences number of VSL members per VSL bundle.
The capacity planning is explained under the "Capacity Planning for the VSL Bundle"
section on page 3-12. There are three design options for avoiding a single point-of-failure:
Design option 1 (Figure 2-10) is the most common and most intuitive choice. It uses both
10-Gbps ports on the supervisor. However, this option does not provide optimal hardware
diversity as both ports are connected to single internal fabric connection. The probability of
having both port connections to the fabric backplane having hardware errors is low, but not
impossible.
–Use one 10-Gbps port from the Sup720-10G supervisor and another from a VSL capable
line card (WS-X6708 or WS-X6716)
Design option 2 (Figure 2-11) diversifies the VSL links onto two separate hardware line
cards—one port from the Sup720-10G uplink and another from the WS-X6708 line card.
This is the best baseline and most practical option for balancing cost and redundancy. This
design restricts unused ports on Sup720-10G with CoS-based queuing. Cisco IOS 12.2(33)
SXI removes this restriction.
Figure 2-11 Distributed VSL Bundle between Bundle and 67xx Line Card
–Use both 10-Gbps ports from VSL capable line cards (WS-X6708 or WS-X6716)
Design option 3 (Figure 2-12) uses separate line cards for VSL connectivity. This provides
the best flexibility in term of QoS configurations for uplink ports on supervisors, but is not as
cost effective as design option 2.
32
Figure 2-12 Distributed VSL Bundle between Dual 67xx Cards
Besides avoiding single point-of-failure, the right design selection depends on the
availability of the hardware and usage of the uplink ports on the supervisor (see the "VSL
QoS and Prioritization of Traffic" section). If one 10-Gbps uplink port is used as the VSL
link, then the other 10-Gbps port can only have CoS-based queuing. The Cisco IOS
software as of Cisco IOS 12.2(33) SXI removes the CoS-based queuing restriction and
allows the other non-VSL 10-Gbps port to be configured for DSCP-based queuing. If any of
the Sup720-10G ports are used for connectivity to the core or other network layer in which
QoS requirements require flexibility, then design options 2 and 3 are the available choices.
For superior resiliency, having one VSL link on the supervisor and other on a line card is the
best option. This design option avoids possible catastrophic disconnection of line cards and
allows more ports to be added in the VSL bundle for future growth. Table 2-2 details the
design choices for the VSL links. You should be aware that there is no clear choice that
emerges from the following options for all implementations; however,Table 2-2 does provide
some risk categorization for available choices.
Design 1-1
Design 1-2
Design 2-1
Design 2-2
Design - 3
33
Hardware Configuration
VSL link both on Sup 720-10G uplinks. All uplink ports are available.
VSL link both on Sup 720-10G uplink. Only 10-Gbps ports are available.
One port on Sup 720 and other on 10-Gbps line card. All uplink ports are available.
One port on Sup 720 and other on line card. Only 10-Gbps ports are available.
All uplink ports are available. 10-Gbps and one Gbps are sharing the total 20 Gbps of
bandwidth.
All uplink ports are available. 10-Gbps and one Gbps are sharing the total 20 Gbps of
bandwidth.
CoS-based only since all 10-Gbps ports are used as VSL link. However loses three 1-Gbps
ports.
34
Limited though practical. All uplink ports can only have CoS-based queuing. 10-Gbps line
card can have independent QoS.
More Limited then option 2-1. The reminder 10-Gbps port follows the same QoS
configuration as VLS port. 12.2(33) SXI removes this restriction. 10-Gbps line card can
have independent QoS.
Most Flexible. All sup uplink can be used. All ports on 10 Gbps can have independent QoS
in 10g-only mode.
Possibility of losing both ports on distinct hardware is remote. Risk of failure—very rare.
Possible, due to loss of connectivity to line card in extreme conditions. Risk-Extremely low.
Optimal
Optimal
Optimal
35
Optimal
Delayed
Cost effective, efficient, least flexible for QoS configurations on one Gbps uplink. Not
recommended due to least diversity of hardware.
Practical. Future enhancement makes it best overall from cost, efficiency and link
redundancy. Though reduced QoS flexibility.
Practical. Future enhancement makes it best overall from cost, efficiency and link
redundancy.
Most efficient port usage and flexible QoS. Not as cost effective and optimized as design
option 1-1 and 1-2.
1Queue structure and depth is not a factor in VSL since the mapping and ration remains the
same. Refer to "VSL QoS and Prioritization of Traffic" section.
2The VSL link on Sup720-10G ports will come up faster than VSL on line cards since line
cards need more time for image download, initialization etc. VSS is optimized for faster
booting with VSL link on supervisor port.
This design guide does not cover operational monitoring and troubleshooting of VSS;
however, critical information is included to emphasize the need to manage bandwidth
utilization—and the health of the VSL port-channel and its member links. Relevant CLI
output examples are shown throughout this section.
36
Troubleshooting of the VSS and VSL port-channel interface might require the port-channel
to be spanned to the port to which the network packet decoder is attached. The VSL port-
channel can be spanned. However, you can only span a local port-channel to a local
destination. Refer to the following CLI command output.
Port: Te1/5/4
Port: Te1/5/5
Port: Te2/5/4
Port: Te2/5/5
Session 2
---------
Source Ports :
Both : Po1
Port: Te1/5/4
Port: Te1/5/5
Port: Te2/5/4
Port: Te2/5/5
Note that the Giants counters on the VSL interface (see the output that follows) might lead
to an assumption that something is wrong. In fact, this is a normal output. The reason that
the interface counters notice the giants is due to fact that VSL inter-switch control frame
packets are sent at 1518 bytes + 32 byte of DBUS header between the active and hot-
standby switches. Such oversized packets are seen as giants on VSL EtherChannel.
! <snip>
38
Port Single-Col Multi-Col Late-Col Excess-Col Carri-Sen Runts Giants
Po1 0 0 0 0 0 0 19788377
Te1/2/8 0 0 0 0 0 0 34
Te1/5/4 0 0 0 0 0 0 19788414
<snip>
Po2 0 0 0 0 0 0 693910
Te2/2/8 0 0 0 0 0 0 89
Te2/5/4 0 0 0 0 0 0 693821
The Stateful Switch Over (SSO) technology enables supervisor redundancy in a standalone
Cisco Catalyst 6000 Series platform. SSO keeps the necessary control plane and protocol
states replicated to the backup supervisor. As a result, if an active supervisor fails, a hot-
standby supervisor has enough information about that system and network to continue
forwarding packets and to continue in network protocol participation with the rest of the
network devices. The dual supervisor-enabled system goes through various states during
power-up. During initialization, Cisco IOS determines whether the system has dual
supervisors, determines the hardware mode—simplex (single supervisor) or duplex (dual
supervisor), and identifies which supervisor assumes the active or hot-standby role. Cisco
IOS software also checks the software version on each supervisor and determines whether
the state of the supervisor can enter into SSO or RPR mode. Each supervisor follows the
redundancy facility (RF) states described in Table 2-3, depending on the adopted role
(active or hot standby). For the supervisor that is elected as primary, the supervisor
transitions from lowest (disabled) to highest (active) mode after successful SSO startup.
The hot-standby supervisor goes through a separate state transition as described in Table
2-3 under the heading States when becoming Standby-hot.
RF State Activity
39
Common States to both supervisor
RF_UNKNOWN = 0,
RF_DISABLED = 1,
RF_INITIALIZATION = 2,
RF_NEGOTIATION = 3,
RF_STANDBY_COLD = 4,
RF_STANDBY_CONFIG = 5,
RF_STANDBY_FILESYS = 6,
40
Sync file system from active to hot-standby
RF_STANDBY_BULK = 7,
RF_STANDBY_HOT = 8,
RF_ACTIVE_FAST = 9,
RF_ACTIVE_DRAIN = 10,
RF_ACTIVE_PRECONFIG = 11,
RF_ACTIVE_POSTCONFIG = 12
RF_ACTIVE = 13,
41
Control and data plane active and participating with network
Among these thirteen states, 13-Active and 8-Standby-Hot are critical for determining
operational redundancy. These are summarized in the following brief descriptions:
•State 13-ACTIVE—In this active state, the supervisor is responsible for packet forwarding
and managing the control plane. The control plane functions includes handling Layer-3
routing protocol, Layer-2 protocols (STP, BPDU), management—such as Telnet, Simple
Network Management Protocol (SNMP), and secure shell (SSH), link and device
management (SPAN and CDP), and so on. The active supervisor synchronizes
configuration with the secondary supervisor. Finally, the active supervisor synchronizes the
state and database of the protocols to the secondary supervisor once the hot-standby
supervisor assumes the state of Standby-HOT (hot standby).
•State 8-Standby-Hot—In this hot-standby state, the supervisor is fully synchronized with
the active supervisor and is capable of assuming the active role when needed. This is the
final state of the hot-standby supervisor. In this state, each SSO-aware protocol, based on
relevant events (such as interface state change, MAC update/change/up/down, and so on),
triggers a message from the active supervisor to the hot-standby supervisor. Whenever the
primary active supervisor fails for some reason, the protocol state on the hot-standby
supervisor goes into the execution (run) state. For example, Cisco Express Forwarding
(CEF) is a SSO-aware client. Whenever a change in the CEF's table occurs, the hot-
standby supervisor receives an update. This ensures that when the hot-standby unit
becomes active, the updated copy of the forwarding information base (FIB) can forward
data packet in the hardware, while the control plane undergoes the recovery process. For
more information on SSO, refer to following URL:
http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/ios/12.2SXF/native/configuratio
n/guide/nsfsso.html
The SSO is the core capability that enables VSS high availability. SSO operational and
functional support is similar to standalone node operating with a dual supervisor. The two
major differences are as follows:
•SSO operation is extended over two chassis, where one supervisor is elected as the active
supervisor and the supervisor in the other chassis is designated as the hot standby. This
function is defined as inter-chassis SSO. See Figure 2-13.
42
•The packet forwarding occurs on both chassis and supervisors, hence the VSS is a dual
forwarding solution, although the control plane is managed by only one supervisor.
The SSO operation in the VSS has the same dependency as in the case of a standalone
environment. The inter-chassis SSO mode requires identical hardware and Cisco IOS
software in both member chassis. Please refer to the URL below for the detailed list of
dependencies for the SSO redundancy mode:
http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/ios/12.2SX/configuration/guide/
vss.html#wp1059586
Note Cisco IOS 122.(33)SXI removes some of the Cisco IOS software versioning
dependencies. Refer to the appropriate release note for more information.
As shown in Figure 2-13, one supervisor is actively providing the unified control plane. The
chassis carrying the active supervisor is called the active virtual switch. In the active switch
all three components are active (green)—Switch Fabric (SF), Route Processor (RP), and
Policy Forwarding Card (PFC). The active supervisor is also responsible for programming
the hardware forwarding information onto all the distributed forwarding cards (DFC) across
the entire VSS—as well as programming the policy feature card (PFC) on the hot-standby
virtual switch supervisor engine. The unified control plane is responsible for the origination
and termination of the traffic types described in the "Network Control Plane Traffic" section
—as well as being the sole control-point for maintaining and managing inter-switch
communications described in the "VSS Inter-Switch Communication and Layer-2 per Link
Control Traffic" section.
43
Note With the first release of VSS, only single supervisors are supported per physical
chassis. Therefore, there is no intra-chassis supervisor engine redundancy. A subsequent
software release might offer the ability to add a second supervisor engine into each chassis.
As show in Figure 2-13, both supervisor resources (SF and PFC) are active for user-data
forwarding. The Policy Feature Card (PFC) and switching fabric (backplane connectivity for
fabric-enabled module) of both supervisors are actively forwarding user data and performing
policy functions, such as applying access control lists (ACL) and QoS in hardware.
Additionally, all Distributed Forwarding Cards (DFC) can also simultaneously perform
packet lookups across the entire VSS. Because the switching fabrics of both switches are
also in an active state, the Cisco VSS has the switch fabric capacity of 1440 (720 Mbps x 2)
Gbps, or 1.44 Tbps in aggregate.
The active and hot-standby supervisors run in a synchronized mode in which the following
system information is synchronized over the VSL link:
•Boot environment
•Protocol states and the database table—Only protocols capable of supporting SSO
redundancy (SSO-aware) are fully capable of supporting SSO-based recovery
Both active and hot-standby switches can learn the address simultaneously; however, the
active virtual switch manages the network information from adjacent devices (such as MAC,
44
STP, or CEF). Several protocols are SSO-aware such that active switch synchronizes
protocol information (database, protocol state) to the hot-standby supervisor. In addition, the
active supervisor manages and updates the information about interfaces and line card
status on both chassis.
The state of the supervisor's control plane (active, hot-standby, or any other state) can be
checked using the following CLI commands. Notice that the fabric state is active in both the
chassis, indicative of the dual forwarding state.
My Switch Id = 1
Peer Switch Id = 2
-----------------------------------------------
12.2(32.8.11)SX76
BOOT = sup-bootdisk:s72033-
adventerprisek9_wan_dbg-mz.SIERRA_INTEG_070502,1;
CONFIG_FILE =
BOOTLDR =
-----------------------------------------------
12.2(32.8.11)SX76
BOOT = sup-bootdisk:s72033-
adventerprisek9_wan_dbg-mz.SIERRA_INTEG_070502,1;
CONFIG_FILE =
BOOTLDR =
46
Configuration register = 0x2102
Note Cisco IOS software images on both supervisors must match otherwise the standby
supervisor will boot in RPR mode and the line card will not be active on that chassis. Refer
to following publication for further information on RPR:
http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/ios/12.2SXF/native/configuratio
n/guide/redund.html
Having a unified control plane and supporting distributed forwarding with more than one
switch requires some form of protocol to determine which switch should (or can) become
active, how to change the default setting, and how to deterministically configure which
switch member will become active. VSS has a dedicated protocol called Role Resolution
Protocol (RRP) that is used to define such behavior. See Figure 2-14.
RRP protocol is used to determine the SSO role (active, hot-standby, or RPR), and to
negotiate switch priority and preemption of virtual switch. RRP also checks the software
version on each switch which must be the same in order to form a VSS.
The RRP protocol is initialized once Link Management Protocol (LMP) is fully established
on at least one VSL port. The LMP control link is selected by RRP protocol to negotiate the
SSO role and switch priority. Each switch member forms local RRP peer group instance
and communicate over the control link of the VSL bundle instead running on every VSL link.
RRP negotiation packets are encapsulated in the same format as the LMP protocol. Hence,
RRP packets are placed into the transmit priority queue in order to prioritize it over data
traffic.
47
RRP protocol status can be verified using commands illustrated in Figure 2-15. As shown in
the output, the remote command switch-id command is needed to verify the RRP state of
the hot-standby switch. The Peer Group is always 0 on the local switch and 1 for the
neighbor switch—regardless of switch ID, priority, preemption, or current SSO role.
•When the hot-standby switch is in the bootup process while the active switch is operational
•When in the dual active recovery phase and the VSL link is restored between virtual switch
members
The RRP session is briefly established during the preceding conditions; however, RRP does
not maintain a session between two switch members, instead RRP relies on internal
notifications from LMP on each switch member. If all VSL member links fail, RRP does not
have any control-link path for communication between peers; the LMP protocol on each
virtual switch will delete the peer group and notify the RRP process to take SSO-based
switchover action. In the absence of VSL link, no RRP action is taken on the active switch if
it is still operational; however, the hot-standby switch will transition to the active role
because it has no way to determine the remote peer status.
The selection of the switch member that is to become the active or hot-standby switch
depends on the order and the way in which the switches are initialized. If the switch
members boot simultaneously, the switch with the lowest switch ID becomes the active
virtual switch. If each switch member boots at different times, then the switch that is initiated
first becomes the active virtual switch regardless of switch ID. The VSS can also be
configured with switch priority. Usually, the default switch priority (100) need not change;
however, you can configure switch priority for two possible requirements:
48
•You are required to override the default selection of the switch role after initial
configuration. This might be due to a need for operational flexibility or requirement for
monitoring access. However, the software will not immediately enforce the configured
switch priority. Adopting this change requires a reload of both switches in order for the RRP
to enable the designated switch to become active. Figure 2-16 illustrates the commands
associated with making a change to the switch priority and a syslog message indicating that
a reload is required to enforce the new designated priority. If the switch with lower priority
comes up first, the software will not force the takeover of the active role when the switch
with a higher priority boots up later—unless that switch is configured with preemption.
•Defining the priority of the switch to match the switch ID will show up in the configuration,
which can provide a visual aid in change management. This option is shown in Figure 2-17,
where the switch priority is configured to match the switch ID (matching high priority to
lowest switch ID).
Switch Preemption
If the intention is to select one of the switches to be in the active role in all conditions, then
simply increasing switch priority will not achieve this goal. For a deterministic role selection,
regardless of the boot order, the desired active switch must be configured with a higher
switch ID and switch preemption. See Figure 2-18.The CLI allows the preemption feature to
be configured on a low-priority switch. However, the switch preemption setting will not be
effective.
49
The implication of switch preemption on the network availability is significant and must be
evaluated before deployment. The operational impact of switch preemption should not be
compared with widely understood HSRP/GLBP protocol behavior in which preemption only
allows relegating the role of being the active HSRP/GLBP forwarder to being in standby
mode without much impact to the network (no reload or reset of the chassis).
Tip Cisco recommends that you do not configure switch preemption for the following
reasons:
•It causes multiple switch resets, leading to reduced forwarding capacity and unplanned
network outages.
•The VSS is a single logical switch/router. Both switch members are equally capable of
assuming the active role because it does not matter which is active—unless required by
enterprise policy.
The normal VSS boot-up process consists of diagnostics, VSL link initialization, LMP
establishment, and switch role negotiation via RRP. RRP determines the role of each switch
leading to the SSO state in which one switch is active and the peer is in the hot-standby
state. However, the behavior and the end result are different if there are problems or events
leading to VSL interface being inactive/disabled/failed after the RRP negotiation phase in
which each switch role was assigned. The VSL link typically becomes disabled for one of
two primary reasons:
50
•Due to the VSL interface and/or line card being non-operational.
•The switch that assumed the role of being active has problems leading to reset of the
switch and thus the VSL interface is non-operational.
In both cases, the peer switch that has assumed the role of hot standby cannot continue
booting, as there is no way to determine (or exchange) the state of the peer switch (due to
the VSL being down). The Cisco IOS software will issue a forced reset (described as
crashed in Cisco IOS parlance) and the peer switch will restart the boot process. If the peer
(hot-standby) switch finds that VSL link is still down it will continue booting. In the absence
of RRP, it will assume the role of active. This situation can lead to dual-active condition
because neither switch has knowledge of the other. For this reason, dual active detection is
a mandatory when deploying VSS in campus network. Please refer to the "Campus
Recovery with VSS Dual-Active Supervisors" section on page 4-18 for more details.
Traditional EtherChannel aggregates multiple physical links between two switches. MEC is
an advanced EtherChannel technology that extends link aggregation to span over two
separate switches. VSS allows for distributed forwarding and a unified control plane so that
the MEC appears as single port-channel interface existing on both the active and hot-
standby switches. Even though the access-layer is connected to a distinct physical chassis
via two physical links, from an access-layer switch perspective, this port-channel connection
enables a single logical link connected to a single logical switch (referred to as VSS with
MEC). Figure 2-19 depicts a physical-to-logical transformation in which the logical topology
is simplified and (for the spanning tree) VSS with MEC offers no-loops.
Note MEC configuration is only possible in the VSS; however, access-layer switches
requiring connectivity to the VSS are configured with traditional EtherChannel interfaces.
51
This capability of spanning EtherChannel over multiple switches as a virtualized, single
logical switch creates a topology in which all devices connected via MEC to VSS appear as
a star-shaped topology. See Figure 2-20.
The MEC and VSS bring powerful and very effective changes to the campus topology. Two
key benefits are as follows:
•Doubles the available bandwidth for forwarding—MEC replaces spanning tree as the
means to provide link redundancy. This means that all physical links under the MEC are
available for forwarding traffic. The STP can no longer block individual links since its
database does not have those links available to calculate a loop-free path. For the network
with a looped topology, the total forwarding capacity is half the available bandwidth of
physical links. VSS with MEC makes all links available for forwarding and thus doubles the
bandwidth available. This offers is an effective change to an existing network in which the
lack of a 10-Gbps infrastructure requires choosing a design alternative (EtherChannel on
each uplink, routed access, multiple HSRP group, and so on) to efficiently utilize the
available links. For any new design, VSS with MEC enables these benefits with simplified
topology.
52
Why MEC is Critical to VSS-Enabled Campus Design
It is important to understand why MEC is critical in a VSS design, before going into detail
about MEC functionality, its operation, traffic flow, and implications in campus design. You
can have a VSS-enabled network without MEC; however, the resulting topology will consist
of either a single point-of-failure (only one link to adjacent network devices) or a looped
topology because both links from a given networking device will be connected to a single
logical VSS switch in a non-EtherChannel configuration. Either condition reduces the
benefits of VSS in any given network. Chapter 3, "VSS-Enabled Campus Design." provides
several design proof points to justify the importance of the MEC-enabled design. The
following are the major advantages of an MEC-enabled design:
•Reduces or eliminates control plane activities associated with a single-link failure (either
nodal failure or member link failure).
•Reduces MAC learning and because the failure of one link does not trigger the Layer-2
control plane convergence.
•Avoids multicast control plane changes (avoids multicast incoming interface changes),
because the failure of one link does not trigger Layer-3 control plane convergence
53
•Enables flexibility in deploying dual-active detection techniques (see the "Campus
Recovery with VSS Dual-Active Supervisors" section on page 4-18).
Types of MEC
Layer-2 MEC
In a hierarchical, three-layer network, the Layer-2 MEC applies to the connection between
the access layer and the distribution layer (where VSS is enabled) as shown in Figure 2-22.
In this mode, the Layer-2 MEC is participating in STP, MAC-address learning, and a host of
other Layer-2 operations. Layer-2 MEC enabled connectivity can be extended to create
large hierarchical Layer-2 topology in which the entire network is loop free. This document
does not cover such designs.
Layer-3 MEC
Layer-3 MEC is comprised of a routed port-channel interface. With Layer-3 MEC, the port-
channel interface is configured as a routed interface bearing the IP address that participates
in Layer-3 functions, such as routing and forwarding using CEF. The natural extension of
this type of connectivity is to have multiple, Layer-3 VSS pairs connected together to form
the basis for a routed design. The routing application of Layer-3 MEC is discussed in the
"Routing with VSS" section on page 3-44.
54
Link Aggregation Protocol
The EtherChannel is a logical interface. Managing the behavior of a physical member link
with (and operational impact on) the rest of the network requires some form of control plane.
Two methods available to manage control plane of the underlying link in an EtherChannel
group are as follows:
•Ensures link aggregation parameter consistency and compatibility between the VSS and a
neighbor switch
•Dynamically reacts to runtime changes and failures on local and remote EtherChannel
configurations
•Detects and removes unidirectional link connections from the EtherChannel bundle
The EtherChannel is the fundamental building block in a VSS-enabled campus design. The
successful deployment of MEC requires operational consistency and interaction with
several access-layer switches creating topology that does not introduce unexpected
behavior. For these reasons, the MEC interface must be enabled with either PAgP or LACP
in order to benefit from functionality described in the preceding discussions. As with
traditional EtherChannel, having PAgP or LACP enabled on an MEC provides consistency
checks the system configuration and the operational state of the underlying physical links.
PAgP and LACP remove a mismatched link from the bundle and thereby provide additional
protection against mismatched configurations and operational verification via syslog
messages. The following configuration must match in all underlying physical links
participating in an MEC bundle.
55
•Configuration of VLANs on member links
•Port status (full- or half-duplex) and QoS support by underlying hardware must be the
same in all links
For a complete list of the requirements for forming an EtherChannel, please refer to the
individual product release notes and related documentation at www.cisco.com. PAgP and
LACP design considerations (as applicable to VSS) that can affect network design are
described in "PAgP" and "LACP (IEEE 802.3ad)" sections that follow.
PAgP
PAgP is the mostly widely used link aggregation protocol. PAgP is supported by most Cisco
devices and other third-party network interface cards (NIC). In the VSS context, PAgP
provides the value-added function of providing assistance in a dual active recovery—in
addition to function summarized in the preceding section. PAgP runs on each MEC link
member, establishes and manages neighbor adjacency between the VSS and a Layer-2 or
Layer-3 partner. PAgP determines multiple attributes on a per member link basis, such as
peer-switch state, device name, partner-port, port-aggregation capability, and port-channel
bundle group index.
Device ID
The active switch is responsible for origination and termination of PAgP control-plane traffic.
PAgP advertises a device-id in order to identify each end of a connection with a unique
device status. For VSS, it is a 48-bit number in MAC address format (02.00.00.00.00.xx). It
consists of a combination of a fixed prefix (02.00.00.00.00) in first five octets and a variable
value (xx) for last octet. The variable part is the virtual switch domain identifier configured
for the system. This PAgP device-id is sent by the two links terminated on two switches that
make up a VSS domain. Because the device-id is the same, a remote device assumes that
the device-id is coming from the single logical device (the VSS). Even during role
switchover in VSS, the device-id remains consistent on each PAgP neighbor to prevent a
renegotiation process. This use of the virtual switch domain identifier in PAgP and LACP
requires that the identifier to be unique in all VSS domains that are interconnected through
the use of MEC. The following command output examples illustrate the device-ID value
described in this section, showing the fixed and variable components.
56
6500-VSS# sh run | inc virtual
There are many configuration options for PAgP. The best practices for configuring PAgP for
EtherChannel are documented in the publication at the following URL:
http://www.cisco.com/en/US/products/hw/switches/ps700/products_white_paper09186a008
01b49a4.shtml
This design guide provides selected details from these documents and integrates
recommendations that are suited to the VSS-enabled campus environment.
Table 2-4 shows only the best practice-based configuration options. Out of the three
choices shown, the recommended mode for PAgP neighbors is desirable-desirable. This
configuration option enables PAgP on both sides and forces the consistency check
mentioned previously in this section. The desirable-desirable option is the best option for
ensuring safe and reliable operation of MEC-connected devices. Unlike LACP, PAgP offers
strict channel settings and configuration checks prior to bundling the ports. MEC bundle
remains in disabled state if PAgP+ detects a configuration mismatch and remains disabled
until the error is fixed. This additional measure prevents EtherChannel inconsistency, which
57
would otherwise create operational challenges for managing large-scale EtherChannel
deployments.
VSS
Remote Node
MEC State
desirable
desirable
operational
desirable
auto
auto
desirable
The additional configuration options of silent or non-silent are available based on the
network requirements. For most network designs, silent mode is preferred. The silent mode
integrates the link into a bundle whether the data is present or not. A non-silent option is
used as an indirect measure of link integrity. For the best-practice design, UDLD is the
preferred method of link integrity check. As a result, the silent option is more applicable to
most network implementations.
58
Why You Should Keep the PAgP Hello Value Set to Default
•The VSS control plane might not recover (during the SSO switchover) in 3 seconds, so that
the VSS can send a PAgP hello before the remote end declares VSS as being non-
responsive. This can lead to false positive
Note Even though one side of the EtherChannel is configured with fast-hello and other side
(or device) is configured with slow-hello, operationally they will transmit and receive fast-
hellos between devices. This means that even though VSS is configured with slow-hello,
improper configuration on remote devices can alter the operational mode of hello
messaging.
Tip The best practice is to keep the PAgP timer settings to default values and to use the
normal UDLD to monitor link integrity.
59
http://www.cisco.com/en/US/products/hw/switches/ps700/products_white_paper09186a008
01b49a4.shtml
Device ID
LACP implementation on the VSS uses a pre-computed system-id. The LACP system ID
consists of a 48-bit address that is a combination of a fixed prefix in the first five octets
(02.00.00.00.00) and variable for last octet (xx). The variable part is the virtual switch
domain identifier configured for the systems. The following output examples identify the
system-id with virtual switch domain number used in last octet of system-id.
For the same reasons described in preceding PAgP description, Table 2-5 shows only the
best practice-based configuration options. Our of the three choices shown, the
recommended mode for LACP neighbors is active-active
VSS
Remote Node
MEC State
active
active
60
operational
active
passive
passive
passive
The following CLI output and configuration process illustrates this behavior. In following
output example, the LACP link member is reconfigured with an inconsistent configuration.
When a mis-configured interface is attempting to join the port-channel interface, the
configuration checks trigger an unique system-generated, port-channel interface.
6500-VSS(config-if) # shut
6500-VSS(config-if)# no shut
and cannot attach to them (trunk mode of Gi2/2 is trunk, Gi2/1 is dynamic)
port-channel
! interface
Po20B Altn BLK 4 128.1668 P2p ! Individual port running STP is blocked
•The first bundle is associated with the port that has succeeded in its configuration check.
•The second bundle is system generated and includes the port that did not match
configuration.
•As a result, the control plane will be active on both port-channel interfaces (each having
one member). The resulting topology consists of two distinct Layer-2 paths created between
access-switch and the VSS as shown in Figure 2-23 (this is also true for Layer-3 MEC, but
is not shown in the example). The STP topology will consider such network as looped and
62
will block the port with higher STP priority. This is one of the major behavioral
considerations for a network topology for LACP compared to PAgP. PAgP offers stricter
channel settings and configuration checking prior to bundling the ports. In PAgP, the MEC
remains disabled (state is shows as down) if PAgP+ detects a configuration mismatch—
until the error is fixed.
Why You Should Keep the LACP Hello Value Set to Default
As with PAgP, LACP allows you to configure a hello interval from a default of 30 seconds
(slow-hello) to 1 second (fast-hello). Unless the both ends of the LACP neighbor device
connection are configured with identical configuration, the LACP hello can be sent at an
asymmetric rate from either side. In other words, it is possible that a remote device
connected to the VSS can send the LACP with slow-hello and can VSS send the LACP with
fast-hello. If the fast-hello method is used for detecting a link failure, the detection time
could also be variable based on configuration (30 seconds at one side and three seconds at
other end). This is different from PAgP, where the hello transmission rate defaults to fast-
hello on both sides (whenever a fast-hello request is made). A fast-hello configuration
should be avoided in a VSS deployment for two reasons:
•The VSS control plane might not recover (during the SSO switchover) in 3 seconds
(timeout for fast-hello), so that the VSS can send an LACP hello before the remote end
declares VSS as being non-responsive. This can lead to false positive
•If the server connected to the VSS is configured based on LACP-MEC with fast-hello, then
there is no inherent method to stop the VSS from sending the fast-hello. This can trigger
excessive CPU usage when scaled to higher numbers of servers requesting such service.
Tip The best practice is to keep the LACP timer settings to the default values and to use the
normal UDLD to monitor link integrity.
63
The minimum link feature of LACP is used to maintain a level of bandwidth (in terms of
number of interfaces in the up/up state) needed for a given application or networking
requirement. If the number of links supporting a certain bandwidth falls below a minimum
requirement, the bundle is taken out of service. In the standalone design, the minimum link
feature is deployed between two separate nodes; the alternate node is available for
forwarding traffic as needed. For the VSS, the behavior of the minimum link features is
different. In VSS, the LACP EtherChannel minimum link configuration is maintained on a
per port-channel basis—although its enforcement is on a per physical chassis basis. The
following configuration example and Figure 2-24 illustrate application of this feature.
6500-VSS# conf t
6500-VSS(config-if)# shutdown
down
down
min-links
min-links
64
—%LINEPROTO-SW1_SP-5-UPDOWN: Line protocol on Interface GigabitEthernet1/4/2,
changed
state to down
down
to down
m - not in use, port not aggregated due to minimum links not met
For a MEC using the LACP control protocol, minlinks defines the minimum number of
physical links in each chassis for the MEC to be operational. For an example, with the port-
channel min-links 2 configuration on the MEC, each virtual-switch member must match at
least two operational local member link ports in order to be associated with the MEC. If one
of the member links is down, the other member in the chassis will be put into the not in use
state. The effect of this enforcement is that one link failure will cause the complete loss of
connectivity from one switch member—even though other links are available for forwarding
traffic—as shown in the preceding syslog output examples and Figure 2-24. This is will
force rerouting of traffic over the VSL link—further congesting the two links that are in the
bundle of the other chassis.
------+-------------+-----------+-----------------------------------------------
<snip>
<<snip>>
6500-VSS# conf t
66
6500-VSS(config-if)# port-channel min-links 2
6500-VSS(config-if)#
down
down
min-links
min-links
to down
to down
meet min-links
67
meet min-links
For an MEC using LACP control protocol, min-links defines the minimum number of
physical links in each chassis for a MEC to be operational. With a single member connected
to each physical chassis, the configuration violates the minimum link requirements. The
following example output illustrates that the port-channel interface is disabled and that the
LACP state for each member link is in a wait state. The usage of the min-link feature
disables the MEC for the associated connection.
! <<snip>>
w - waiting to be aggregated
------+-------------+-----------+-----------------------------------------------
Tip The use of the minimum links feature in the campus environment is not very effective.
For all practical deployments of the VSS in the campus (two uplinks from each adjacent
network devices), the minimum links feature should not be used.
MEC Configuration
Configuration requirement for MEC is almost identical with standard EtherChannel interface.
This section covers the basic configuration caveats, QoS support, and syslog guidelines for
MEC configuration.
The procedure used to configure Layer-2 EtherChannel differs when compared with Layer-3
EtherChannel. Key considerations are as follows:
•Do not create Layer-2 MEC explicitly by defining it via the CLI. Instead, allow the Cisco IOS
system to generate the Layer-2 MEC interface by associating to the port-channel group
under each member interface.
•Create a Layer-3 MEC interface explicitly via the CLI and associate the port-channel group
under each member interface.
http://cco.cisco.com/en/US/partner/docs/switches/lan/catalyst6500/ios/12.2SX/configuration/
guide/channel.html#wp1020478
QoS for MEC follows similar procedures as with any standard EtherChannel configuration.
For generic QoS support or restrictions related to the VSS, please refer to following white
paper QoS chapter:
69
http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps9336/white_paper_c11_429
338.pdf
Monitoring
Cisco IOS Release 12.2(33)SXH1 for the Cisco Catalyst 6500 platform now supports
previously hidden commands for monitoring traffic flow on a particular link member of a
MEC or EtherChannel. The following remote command will generate output depicting the
interface and the port-channel interface being selected for a given source and destination
Hidden commands:
1.1.1.1 2.2.2.2
The following syslog configuration (logging command) is recommended in VSS with MEC
interfaces. These commands can also be applied to the devices connected to the VSS as
long as those devices support the respective syslog functionality.
70
Port-channel interfaces configurations:
interface Port-channel20
interface GigabitEthernet1/8/1
71
logging event trunk-status
Load sharing, traffic flow behavior, and failure conditions are covered in Chapter 3, "VSS-
Enabled Campus Design," because the behavior and impact of MEC load sharing is more
related to overall design of the campus network.
MAC Addresses
In a standalone Cisco Catalyst 6500, the MAC addresses used for each interface and
control plane is derived from the back plane EEPROM. VSS consists of two chassis (see
Figure 2-25). Each physical member of VSS pair consists of pool of MAC addresses stored
in backplane EEPROM.
The VSS MAC address pool is determined during the role resolution negotiation. The active
chassis pool of MAC addresses is used for the Layer-2 SVI and the Layer-3 routed interface
72
—including the Layer-3 MEC interface. The Layer-2 MEC interface uses one of the link-
member MAC addresses. The following CLI output examples reveal the active pool of MAC
addresses.
------------------------------------------------------------------
The MAC address allocation for the interfaces does not change during a switchover event
when the hot-standby switch takes over as the active switch. This avoids gratuitous ARP
updates (MAC address changed for the same IP address) from devices connected to VSS.
However, if both chassis are rebooted together and the order of the active switch changes
(the old hot-standby switch comes up first and becomes active), then the entire VSS domain
will use that switch's MAC address pool. This means the interface will inherit a new MAC
address, which will trigger gratuitous ARP updates to all Layer-2 and Layer-3 interfaces.
Any networking device connected one hop away from the VSS (and any networking device
that does not support gratuitous ARP), will experience traffic disruption until the MAC
address of the default gateway/interface is refreshed or timed out. To avoid such a
disruption, Cisco recommends using the configuration option provided with the VSS in
which the MAC address for Layer-2 and Layer-3 interfaces is derived from the reserved
pool. That takes advantage of the virtual switch domain identifier to form the MAC address.
The MAC addresses of the VSS domain remain consistent with the usage of virtual MAC
addresses, regardless of the boot order. For the exact formula, see the command and
configuration chapter for VSS at www.cisco.com.
Tip Cisco recommends the configuration of a virtual MAC address for VSS domain using
the switch virtual domain command.
73
6500-VSS(config)# switch virtual domain 10
The individual MAC addresses that reside in each chassis EEPROM are useful for assisting
in the dual-active detection process. The following show commands illustrate how to find the
base address for each chassis.
The above base addresses located on each chassis are used by the dual-active detection
method described in "Campus Recovery with VSS Dual-Active Supervisors" section on
page 4-18.
In VSS, the MAC address of the Layer-2 MEC interface is derived from one of the link-
member burn-in (bia) interface MAC addresses. In a normal condition, the MAC address of
the first interface added to the port-channel interface is chosen for Layer-2 port-channel
(MEC) interface. If the interface whose MAC address is used for the port-channel is
disabled, the port-channel interface will start using remaining member interface MAC
addresses. However, if the interface that has just been disabled is reactivated, the Layer-2
MEC does not reuse the MAC address of that interface.
The process of inheriting the MAC address of the Layer-2 port-channel is shown below. The
burn-in address (bia) of the the port-channel is derived from the first interface that was
added to the port-channel.
74
6500-VSS#show interface gig 1/8/1 | inc bia
Note that the output where port-channel interface MAC address is derived from Gigabit
interface 1/8/1.
6500-VSS# conf t
6500-VSS(config-if)# shutdown
After disabling the link-member Gigabit-interface 1/8/1 whose MAC address was used by
Layer-2 MEC, the port-channel starts using the remaining member (Gigabit-interface 2/8/1)
burned-in address.
6500-VSS(config-if)#no shutdown
In normal condition, the Layer-2 MAC address is used as sources of BPDU frame (addition
of link activates the MEC interface and STP operation on that port). If the interface member
(whose MAC address is used by Layer-2 MEC) is disabled, the change of source MAC in
BPDU frame is detected by the switches connected to the VSS; however, the root MAC of
the STP remains the same. This implies that STP topology did not change. For details, refer
to "STP Operation with VSS" section on page 3-36.
Back to Top
Yes No FeedbackFeedback
76
Configuring VSS
Contact Cisco
in Security Documents
in Security Documents
Segmentation Strategy
in Security Documents
Cisco Community
FOLLOW US
Newsroom
Events
Blogs
Community
77
About Us
Customer stories
Investor relations
Social responsibility
Environmental sustainability
Contact Us
Find a reseller
Careers
We Are Cisco
Meraki
Webex
Webex Teams
Cisco Umbrella
Contacts Feedback Help Site Map Terms & Conditions Privacy Statement Cookies
Trademarks
By continuing to use our website, you acknowledge the use of cookies. Privacy Statement |
Change Settings
78