100% found this document useful (1 vote)
4K views

Error Codes: Genius Display Status Overview Shows Error Codes. New Codes For The GENIUS Are Marked Yellow

This document lists error codes, descriptions, and recommended actions for resolving issues with a GENIUS MT oven. It includes codes for door issues, probe failures, temperature errors, safety releases, water problems, filter warnings, overheating errors, and other software or component issues. Yellow highlighted codes are new for the GENIUS MT model.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
4K views

Error Codes: Genius Display Status Overview Shows Error Codes. New Codes For The GENIUS Are Marked Yellow

This document lists error codes, descriptions, and recommended actions for resolving issues with a GENIUS MT oven. It includes codes for door issues, probe failures, temperature errors, safety releases, water problems, filter warnings, overheating errors, and other software or component issues. Yellow highlighted codes are new for the GENIUS MT model.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

4.

Error codes
GENIUS MT Display Status overview shows error codes.
New codes for the GENIUS MT are marked yellow.

Table 2
Error
Descritpion What to do
code
1 Door open  Close the door / operating panel.
 Check the door switch, inside the
operating panel. Is the magnet lost
(Inside the door frame)?
 EB 30 Door switch blinking
 Only units with electro-mechanic closing
007 Door doesn’t open mechanism
40 Invalid reference 
temperature
111 Probe chamber 1 (top)  Check probe 0,789mV at 20°C,
No signal, Oven will NOT operate with a defective
with TC-AddOn Board probe.
Short cut
Probe chamber 2
(bottom)  Check probe 0,789mV at 20°C,
112 No signal, Oven will NOT operate with a defective
with TC add on board probe.
short cut chamber 2
Core probe  Check probe 0,789mV at 20°C,
113
No signal sensor 1 Meat probe operation is possible
Core probe  Check probe 0,789mV at 20°C,
114
No signal sensor 2 Meat probe operation is possible
Core probe  Check probe 0,789mV at 20°C,
115
No signal sensor 3 Meat probe operation is possible
Core probe  Check probe 0,789mV at 20°C,
116
No signal sensor 4 Meat probe operation is possible
Probe waste water (drain)  Check probe 0,789mV at 20°C,
117
No signal Oven will operate with a defective probe.
Temperature too high  Sensor TC2 value above 400°C
119
sensor 1 Oven will not operate
Temperature too high  Sensor TC3 value above 400°C
120
sensor 2 Oven will not operate
No operation if core probe is activated
Core probe temperature
121 Warning if core probe not used
too high
 Sensor TC1 above 400°C
Condensate temperature
122  Warning, Sensor TC4 above 400°C
too high
Temperature too low
 Sensor TC2 value below -30°C
124 Cooking chamber
Oven will NOT operate
(top)
Temperature too low
 Sensor TC3 value below -30°C
125 Cooking chamber
Oven will NOT operate
(bottom)
No operation if core probe is activated
Core probe temperatur
126 Warning if core probe not used
too low
 Sensor TC1 value below -30°C
Temperature to low Warning
128
Condensate  Sensor TC4 value below -30°C

32
No operation if core probe is activated
Core probe sensor
130 Warning if core probe not used
defective
 No signal of all 4 core probe sensorsl
211 Upper safety thermal  Reset the upper safety thermal release.
release  If the STR has not released, check if the
motor temperature sensor switched off,
this is a bi-metal trip, which reset itself
when cooled down. If so, control if the
main/motor fuses. Replace and check
possible causes: Defective motor
windings or the motor is blocked.
 Oven cannot operate!
Lower safety thermal  Reset the lower safety thermal release.
release  If the STR has not released, check if the
212 motor temperature sensor switched off,
this is a bi-metal trip, which reset itself
when cooled down. If so, control if the
main/motor fuses. Replace and check
possible causes: Defective motor
windings or the motor is blocked.
 Oven cannot operate!
No motor signal  Check the main / motor fuses. Replace
them, if blown and check possible
causes: Defective motor windings or the
motor is blocked.
213  Check motor parameters for start up
and slow down. See programming
manual.
 Units with frequency converter may
block operation when switched Off/On
instantly. Please wait 5 seconds after
switch off before switch on again.
 Oven cannot operate!
No water / low water  Open the water tap.
311
pressure  The water flow pressure must be
checked, 2 bar / 29 PSI for soft water.
 Autoclean will pause until pressure
is high enough.
Information
313 Hand shower off  Hand shower disabled via service
menu.
Sensor filling level water
314  Warning for ovens with water tank
tank
315 Flow meter waste water  Ovens with waste water tank will stop
No water pressure during Autoclean: Stop
316
cleaning  Refer code 311
Flow meter solenoid
317  Warning, only for 2 chamber ovens
valve 2 no request
Correct solenoid valve 1 Attention
318
(top)  Check amount of water upper chamber
Correct solenoid valve 2 Attention
319
(bottom)  Check amount of water upper chamber
Attention
320 Hand shower blocked  Hand shower dissabled at temperatures
above 230°C
Warning
400 Air filter dirty
 Clean filter

33
Warning
401 Air filter missing
 Install Filter
Warning
 Clean air filter, located at the bottom of
511 PCB temperature 65°C the front panel.
 Check if the compartment fan and the
fan in the front
 Clean air filter, located at the bottom of
the front panel.
512 PCB temperature 70°C  Check if the compartment fan and the
fan in the front.
Oven will not operate
Warning: PCB  Slow overheated PCB.
temperature 68°C  The installation prevents ambient air
513
flow for a cooling effect.
Oven will not operate
 Check the Polarity of the power line
34 Polarity error
Oven will not operate
 Switch unit Off/On
81 Software error
Oven will not operate
 Switch unit Off/On
82 Implausible values
Oven will not operate
 Missing I/O board
83 Simulation mode
Oven will not operate
 Connection I/O-board missing
 Check cable on port X22 (CPU) and
84 Software error
X81 (I/O)
Oven will not operate
 Missing link to I/O board
86 Lost communication
Oven will not operate
 Check gasboard
 Check connection gas board, CPU and
87 Gas Board not connected
IO Board
Oven will not operate
40 InvalidRefTemp 1 Warning
41 InvalidRefTemp 2 Warning
 Errors on 2 reference temperatures
 If error comes up several times, replace
42 InvalidRefTemp1+2
IO board
Oven will not operate
Error temperature sensor
 Please contact Eloma
44 1, heating with no vissible
Oven will not operate
effect
Error temperature sensor
 Please contact Eloma
45 2, heating with no vissible
Oven will not operate
effect
 1) Check temperature sensors
 2) Check cables and connectors
Communication error
46
sensor 1  3) Replace IO Board
Oven will not operate

 1) Check temperature sensors


Communication error  2) Check cables and connectors
47
sensor 2  3) Replace IO Board
Oven will not operate

34
 1) Check connector (bridge) on TCC
Temperature sensor 2 or Add On board
48 TC add on board short  2) Check temperature sensor
cut to earth  3) Replace IO Board
Oven will not operate
 1) Check core probe
Error Condensate
49  2) Replace IO board
temperature sensor
Oven will not operate
 Hardware issue, no logging etc.
988 Retain Data corrupted
Replace CPU
Warning
 Pre heat set point not reached after 2
800 PreHeat TimeOut hours
 Check heating
 Check program settings
Warning
551 USB malfunction  Missing USB stick on active port
 Stick or port defective
Attention
600 Cleaner
 15% of chemical is left over
Attention
601 Rinse
 15% of chemical is left over
Attention
604 Cleaner
 30% of chemical is left over
Attention
605 Rinse
 30% of chemical is left over
No flame upper chamber  Is the phase at L1, polarity!
 Is the kitchen ventilation system
711
working? Interlock?
 Check the ionisation current of the gas
firing
Reset: Pressing restart.
No flame lower chamber  Is the phase at L1, polarity!
 Is the kitchen ventilation system
712
working? Interlock?
 Check the ionisation current of the gas
firing
Reset: Pressing restart.
713 Time out from error 711 Pause, see 711
714 Time out from error 712 Pause, see 712

35

You might also like