Error codes
GENIUS MT Display Status overview shows error codes.
New codes for the GENIUS MT are marked yellow.
Table 2
Error
Descritpion What to do
code
1 Door open Close the door / operating panel.
Check the door switch, inside the
operating panel. Is the magnet lost
(Inside the door frame)?
EB 30 Door switch blinking
Only units with electro-mechanic closing
007 Door doesn’t open mechanism
40 Invalid reference
temperature
111 Probe chamber 1 (top) Check probe 0,789mV at 20°C,
No signal, Oven will NOT operate with a defective
with TC-AddOn Board probe.
Short cut
Probe chamber 2
(bottom) Check probe 0,789mV at 20°C,
112 No signal, Oven will NOT operate with a defective
with TC add on board probe.
short cut chamber 2
Core probe Check probe 0,789mV at 20°C,
113
No signal sensor 1 Meat probe operation is possible
Core probe Check probe 0,789mV at 20°C,
114
No signal sensor 2 Meat probe operation is possible
Core probe Check probe 0,789mV at 20°C,
115
No signal sensor 3 Meat probe operation is possible
Core probe Check probe 0,789mV at 20°C,
116
No signal sensor 4 Meat probe operation is possible
Probe waste water (drain) Check probe 0,789mV at 20°C,
117
No signal Oven will operate with a defective probe.
Temperature too high Sensor TC2 value above 400°C
119
sensor 1 Oven will not operate
Temperature too high Sensor TC3 value above 400°C
120
sensor 2 Oven will not operate
No operation if core probe is activated
Core probe temperature
121 Warning if core probe not used
too high
Sensor TC1 above 400°C
Condensate temperature
122 Warning, Sensor TC4 above 400°C
too high
Temperature too low
Sensor TC2 value below -30°C
124 Cooking chamber
Oven will NOT operate
(top)
Temperature too low
Sensor TC3 value below -30°C
125 Cooking chamber
Oven will NOT operate
(bottom)
No operation if core probe is activated
Core probe temperatur
126 Warning if core probe not used
too low
Sensor TC1 value below -30°C
Temperature to low Warning
128
Condensate Sensor TC4 value below -30°C
32
No operation if core probe is activated
Core probe sensor
130 Warning if core probe not used
defective
No signal of all 4 core probe sensorsl
211 Upper safety thermal Reset the upper safety thermal release.
release If the STR has not released, check if the
motor temperature sensor switched off,
this is a bi-metal trip, which reset itself
when cooled down. If so, control if the
main/motor fuses. Replace and check
possible causes: Defective motor
windings or the motor is blocked.
Oven cannot operate!
Lower safety thermal Reset the lower safety thermal release.
release If the STR has not released, check if the
212 motor temperature sensor switched off,
this is a bi-metal trip, which reset itself
when cooled down. If so, control if the
main/motor fuses. Replace and check
possible causes: Defective motor
windings or the motor is blocked.
Oven cannot operate!
No motor signal Check the main / motor fuses. Replace
them, if blown and check possible
causes: Defective motor windings or the
motor is blocked.
213 Check motor parameters for start up
and slow down. See programming
manual.
Units with frequency converter may
block operation when switched Off/On
instantly. Please wait 5 seconds after
switch off before switch on again.
Oven cannot operate!
No water / low water Open the water tap.
311
pressure The water flow pressure must be
checked, 2 bar / 29 PSI for soft water.
Autoclean will pause until pressure
is high enough.
Information
313 Hand shower off Hand shower disabled via service
menu.
Sensor filling level water
314 Warning for ovens with water tank
tank
315 Flow meter waste water Ovens with waste water tank will stop
No water pressure during Autoclean: Stop
316
cleaning Refer code 311
Flow meter solenoid
317 Warning, only for 2 chamber ovens
valve 2 no request
Correct solenoid valve 1 Attention
318
(top) Check amount of water upper chamber
Correct solenoid valve 2 Attention
319
(bottom) Check amount of water upper chamber
Attention
320 Hand shower blocked Hand shower dissabled at temperatures
above 230°C
Warning
400 Air filter dirty
Clean filter
33
Warning
401 Air filter missing
Install Filter
Warning
Clean air filter, located at the bottom of
511 PCB temperature 65°C the front panel.
Check if the compartment fan and the
fan in the front
Clean air filter, located at the bottom of
the front panel.
512 PCB temperature 70°C Check if the compartment fan and the
fan in the front.
Oven will not operate
Warning: PCB Slow overheated PCB.
temperature 68°C The installation prevents ambient air
513
flow for a cooling effect.
Oven will not operate
Check the Polarity of the power line
34 Polarity error
Oven will not operate
Switch unit Off/On
81 Software error
Oven will not operate
Switch unit Off/On
82 Implausible values
Oven will not operate
Missing I/O board
83 Simulation mode
Oven will not operate
Connection I/O-board missing
Check cable on port X22 (CPU) and
84 Software error
X81 (I/O)
Oven will not operate
Missing link to I/O board
86 Lost communication
Oven will not operate
Check gasboard
Check connection gas board, CPU and
87 Gas Board not connected
IO Board
Oven will not operate
40 InvalidRefTemp 1 Warning
41 InvalidRefTemp 2 Warning
Errors on 2 reference temperatures
If error comes up several times, replace
42 InvalidRefTemp1+2
IO board
Oven will not operate
Error temperature sensor
Please contact Eloma
44 1, heating with no vissible
Oven will not operate
effect
Error temperature sensor
Please contact Eloma
45 2, heating with no vissible
Oven will not operate
effect
1) Check temperature sensors
2) Check cables and connectors
Communication error
46
sensor 1 3) Replace IO Board
Oven will not operate
34
1) Check connector (bridge) on TCC
Temperature sensor 2 or Add On board
48 TC add on board short 2) Check temperature sensor
cut to earth 3) Replace IO Board
Oven will not operate
1) Check core probe
Error Condensate
49 2) Replace IO board
temperature sensor
Oven will not operate
Hardware issue, no logging etc.
988 Retain Data corrupted
Replace CPU
Warning
Pre heat set point not reached after 2
800 PreHeat TimeOut hours
Check heating
Check program settings
Warning
551 USB malfunction Missing USB stick on active port
Stick or port defective
Attention
600 Cleaner
15% of chemical is left over
Attention
601 Rinse
15% of chemical is left over
Attention
604 Cleaner
30% of chemical is left over
Attention
605 Rinse
30% of chemical is left over
No flame upper chamber Is the phase at L1, polarity!
Is the kitchen ventilation system
711
working? Interlock?
Check the ionisation current of the gas
firing
Reset: Pressing restart.
No flame lower chamber Is the phase at L1, polarity!
Is the kitchen ventilation system
712
working? Interlock?
Check the ionisation current of the gas
firing
Reset: Pressing restart.
713 Time out from error 711 Pause, see 711
714 Time out from error 712 Pause, see 712
35