Data Sheet

Symphony Plus
S+ I/O: HAI805 & HAO805 HART I/O

Highlights
Included in Symphony® Plus is a comprehensive suite of
standards-based control and I/O hardware and software
that meets the requirements of total plant automation.
SD Series HAI805 and HAO805 HART I/O modules provide
connection between SD Series controllers and intelligent
devices using the HART communication protocol.

SD Series HART I/O modules scan and update the 4-20 mA


primary and digital secondary variables to the controller for use
in control strategies and higher level applications. In addition to
producing tighter and more reliable process control solutions,
these HART I/O modules lower system installation costs by
reducing instrumentation requirements. System costs are further
reduced by using S+ Engineering to configure and maintain
HART field devices and control strategies.

HAI805 and HAO805 features include:


− − HAI805 (8 analog input channels)
− − HAO805 (8 analog output channels)
− − Dedicated HART modem for each I/O channel
− − Each channel‘s secondary/tertiary/quaternary
variables are available for use in control applications SD Series HART I/O HAI805 & HAO805

− − Update rate of secondary/tertiary/quaternary variables


is less than 750 milliseconds
S+ I/O: HAI805 & HAO805 HART I/O

Specifications
Property Characteristic/Value
General
Mounting Standard 35mm wide DIN-rail horizontally
Power requirements 24 VDC ± 10% at 200 mA; 5 W typical
Support redundant power inputs
Communications and Ports
Symphony Plus controller Redundant 4 Mbps HN800
Service Port 1x mini-USB ports
Capacity
HN800 Up to 64 local HN800 devices up to 30 m, extendable up to 3 km by fiber-optic repeater,
Up to 8 pairs of fiber-optic repeaters in Star configuration
Overvoltage category Tested according to IEC/EN 61010-1
I for power
I for inputs and outputs
Number of channel 8 independently configured channels
Number of HART modem 8, each channel has a dedicated HART modem
Number of HART Secondary Variable Up to 4 per channel, 32 per module
HART Secondary Variables update rate 650 ms typical, 750 ms maximum
Dimensions
HAI805 or HAO805 (with base) 59 mm width, 186 mm height, 127 mm depth
(2.32 in. width, 7.32 in. height, 5 in. depth)
HBX01L 33mm width, 190 mm height, 46 mm depth
(HN800 bus extender, left) ( 1.3 in. width, 7.48 in. height, 1.82 in. depth)
HBX01R 33 mm width, 190 mm height, 31 mm depth
(HN800 bus extender, right) ( 1.3 in. width, 7.48 in. height, 1.2 in. depth)
Weight
HAI805 or HAO805 (with base) 0.56 kg (1.24 lbs)
HBX01L 0.136 kg (0.300 lbs)
HBX01R 0.113 kg (0.250 lbs)
Ambient temperature (operational) 0° to 55°C (32° to 131°F). Tested according to IEC/EN 60068-2-1,
IEC/EN 60068-2-2, IEC/EN 60068-2-14
Temperature (storage) -40° to 85°C (-40° to 185°F). Tested according to MIL-STD-810G
Relative humidity 20% - 95% @ 40°C (104°F) non-condensing.
Tested according to IEC/EN 60068-2-78, IEC/EN 61298-3
Vibration (operational sinusoidal) 5 to 60 Hz 0.137 mm (0.0054 in.)
60 to 150 Hz 1.0 G.
Tested according to IEC/EN 60068-2-6
Vibration (transportation) 10 to 500 Hz. Tested according to MIL-STD-810G

2 S+ I/O: HAI805 & HAO805 HART I/O | Data sheet


Specifications
Property Characteristic/Value
General (continued)
Shock (storage) 15 G, 11 msec. Tested according to IEC/EN 60068-2-27
Altitude (operational) Sea level to 3,048 meters (10,000 ft.) Tested according to MIL-STD-810G
Altitude (storage) Sea level to 12,192 meters (40,000 ft.) Tested according to MIL-STD-810G
Air quality ISA S71.04 G1
ISA S71.04 G3 compliance version HAI805A and HAO805A are also available
EMC Immunity Tested according to IEC/EN 61000-6-2, IEC/EN 61000-4-3, IEC/EN 61000-4-6, IEC/EN 61000-4-8
ESD Immunity Tested according to IEC/EN 61000-6-2, IEC/EN 61000-4-2
Surge Immunity Tested according to IEC/EN 61000-6-2, IEC/EN 61000-4-5
Electrical Fast Transient Immunity Tested according to IEC/EN 61000-6-2, IEC/EN 61000-4-4
Voltage Fluctuation and Interruption Immunity Tested according to IEC/EN 61000-6-2, IEC/EN 61000-4-11
Emission Tested according to IEC/EN 61000-6-4, CISPR 11 + A1, CISPR 16-1-1
Certification
Canadian Standard Association (CSA) Certified for use as process control equipment in an ordinary (nonhazardous) location
CE Mark CE Mark EMC Directive 2004/108/EC & Low Voltage Directive 2006/95/EC

HAI805
Analog Inputs 8 independently configured channels
Current 4 to 20 mA
Resistive load
Current mode (system powered) Up to 750 Ω
Input impedance
Current mode (external powered) 250 Ω
A/D conversion 1 A/D converter

Resolution 12 bits
Conversion update rate 100 msec for all channels
Accuracy (% of full scale range at 25°C)
Current mode 0.10%
Temperature effect on measurement accuracy ±0.003%/degree C maximum
Input to logic isolation Galvanic isolated
Isolation voltage 300 VDC/VRMS at 60 Hz
1,400 VRMS at 60 Hz for 2 sec
Channel isolation Group isolated; 1 group with 8 channels
Isolation voltage 300 VDC/VRMS at 60 Hz
1,400 VRMS at 60 Hz for 2 sec
Current limiting
Short circuit protection 26 mA nominal current limit
Common mode voltage –12 VDC minimum, +15 VDC maximum
Rejection (50-60 Hz)
Normal mode –70 dB minimum
Common mode –90 dB minimum
DC Common mode rejection –90 dB minimum

Data sheet | S+ I/O: HAI805 & HAO805 HART I/O 3


Specifications
Property Characteristic/Value
HAO805

2VAA001983 Power Generation 0914


Analog Outputs 8 independently configured channels
Current 4 to 20 mA
Output load
Current mode 750 Ω maximum
D/A resolution 12 bits
Accuracy (% of full scale range at 25°C)
Current mode 0.15%
Output to logic isolation Galvanic isolated
Isolation voltage 300 VDC/VRMS at 60 Hz
1,400 VRMS at 60 Hz for 2 sec
Channel isolation Group isolated; 1 group with 8 channels
Isolation voltage 300 VDC/VRMS at 60 Hz
1,400 VRMS at 60 Hz for 2 sec
Current limiting
Short circuit protection 26 mA nominal output current limit
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Symphony and Symphony Plus are registered or pending trademarks of ABB.
INFI 90 is a register trademark of ABB

ABB Inc. © Copyright 2014 ABB


All rights reserved. Specifications subject to change without notice. Pictures,
Power Generation schematics, and other graphics contained herein are published for illustration
Wickliffe, Ohio, USA purposes only and do not represent product configurations or functionality.
User documentation accompanying the product is the exclusive source for
Phone: 1 800 435 7365 functionality descriptions.
Email: [email protected] Symphony is a registered or pending trademark of ABB S.p.A

ABB AG
Power Generation
Mannheim, Germany
Phone: +49 621 381 3000
Email: [email protected]

ABB Pte. Ltd.


Power Generation
Singapore
Phone: +65 6776 5711
Email: [email protected]

ABB S.p.A.
Power Generation
Genova, Italy
Phone: +39 010 607 3512
Email: [email protected]

www.abb.com/symphonyplus
www.abb.com/powergeneration

You might also like