Airmaster P1 - A18.1 - EN: Display Values: Standard Features
Airmaster P1 - A18.1 - EN: Display Values: Standard Features
Airmaster P1 – A18.1_EN
Identification: P1
Product Family: Airmaster™
Definition: PLC (pre-programmed logic controller)
Function: Compressor / motor control, I/O monitoring and protection device
Part number: Refer to Product guide / price list for specific part number or contact dealer
Software: Pre-programmed application software, configurable via password protected OUI
Supported protocol: Airbus485, Modbus RTU (via gateway), Profibus DP (via gateway) and DeviceNet (via gateway)
Airmaster™ sets the standard for pre-programmed logic controllers in air compressor, vacuum and related applications. Why? For nearly
30 years, Airmaster™ products have pioneered developments in compressed air and vacuum application PLC’s, ensuring our customers
remain at the forefront in their chosen area of expertise. Our continued commitment to product development has positioned Airmaster™
as the global leader and choice solution for compressed air and vacuum application PLC controls.
Airmaster™ P1 features a backlit 45mm x 25mm graphic display complimented by an ergonomically engineered
membrane switch keypad. Both are conveniently arranged for easy and intuitive access and interrogation of
Airmaster™ P1’s software menus.
A variety of input and output connections are conveniently arranged to the rear of the controller (see over).
Airmaster™ P1 is assembled in a ruggedized housing with an IP65 rating once installed in the host air compressor or
vacuum pump.
Like other Airmaster™ products, P1 carries CE, UL and CSA regulatory approvals.
www.controlcompressors.com
Identification: P1
Product family: Airmaster™
Definition: PLC (pre-programmed logic controller) comprising an industrial computer with an 80C51 family processor,
an operator user interface with a background illuminated graphics display, keys, digital and analogue inputs
Rated voltage: 24vAC +/-15%
Power consumption: 50VA
RAM: 5KB
Flash EPROM: 64KB
Graphic display: Monochrome graphic display, 45mm x 25mm
Backlight: YES
Keypad: 6 tactile key, Membrane switch panel construction
Digital inputs 5 x digital inputs, 0 – 24vAC plus E Stop (see R1C)
C2 : Shutdown Trip (e.g. Motor Fault)
C3 : Shutdown Trip (e.g. Oil Filter)
C4 : Shutdown Trip (e.g. Separator Element)
C5 : Configurable for Alarm, Trip
C6 : Configurable for Alarm, Trip or Selectable Function
Analogue inputs: 1 x 4-20mA input (pressure), 1 x specified KTY, PT100, PT1000 input (temperature)
Relay outputs: 4 x relay outputs:
R1C : R1 Common 24Vac; also used for Emergency Stop Detection
R1 : Load Solenoid - Contacts, 24Vac only, 4A (cosØ=1) / (2.5ADC)
C : R2-4 Common; Contacts, 24Vac to 115Vac, 4A (cosØ=1) / (2.5ADC)
R2 : Main/Line Motor Contactor
R3 : Star Motor Contactor
R4 : Delta Motor Contactor
Serial interface 1 x RS485 (2 optional)
Serial communication: Airbus485™, MODBUS RTU (via gateway), Profibus DP (via gateway), DeviceNet (via gateway)
Software: Pre programmed application software configurable via OUI
Languages: N/A…, alpha, numeric, symbolic
Display symbols: ISO7000 and custom
Dimensions: 144mm (W) x 96mm (L) x 38mm (D)
Construction: IP65 corrosion protected Aluminum Alloy, IP65 polyethylene keypad
IP65 panel mount sealing, IP20 corrosion protected rear steel plate
Mounting: 4 x M4 clearance holes for front accessible screw or rivet type fixings
135mm x 86mm rectangle panel aperture
Regulatory approvals: CE, UL: UL508, CSA: CAN/CSA C22.2 No. 14-M91
Operating temperature: 0°C ~ 55°C (32°F to 130°F)
Storage temperature: -25°C ~ +75°C (-13ºF to 167ºF)
Relative humidity: <95% condensation @ 40°C without condensation
Vibration: IEC 68-2-6 Fc/27 Ea/29 Eb
EMC Immunity: IEC 801-2/3/4/5, EN61000-4-2/3/4/5; CISPR 22, EN55022 class A conducted/radiated ROHS compliant
144 28 10
A2 A1
- + - + C6 C2
96
R1 R2 R3 R4
bar