Cable Id: Fiber Id: Location A: Location B: Jobid: Technician Id

The document is an OTDR test report for fiber 3 from Location A to Location B with a job ID and technician ID. It shows the test was done on October 15, 2020 at 12:14 pm using a SmartOTDR and E126A instrument. The 1310nm test found a link loss of 0.022 dB and an optical return loss of 49.32 dB over the 64.16 meter fiber with 1 event and no alarms.

Uploaded by

Arunava Basak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views1 page

Cable Id: Fiber Id: Location A: Location B: Jobid: Technician Id

The document is an OTDR test report for fiber 3 from Location A to Location B with a job ID and technician ID. It shows the test was done on October 15, 2020 at 12:14 pm using a SmartOTDR and E126A instrument. The 1310nm test found a link loss of 0.022 dB and an optical return loss of 49.32 dB over the 64.16 meter fiber with 1 event and no alarms.

Uploaded by

Arunava Basak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Print date : 15/10/2020 12:18 pm File : MRS-opgw a1.sor.

pdf

Cable Id : Fiber Id : Fiber 3


Location A : Location B :
Job Id : Technician Id : core

SmartOTDR (S/N 1658 ) E126A (S/N 1658 ) Date : 15/10/2020 12:14 pm

Setup
OTDR 1310nm 5ns 1km 16cm 20.0s 1.46750 -79.0 dB
Alarms
Thresholds None
Summary
Filename Laser nm Link Loss dB Link Orl dB Fiber End m Direction Event Alarms
MRS-opgw a1.sor 1310 0.022 49.32 64.16 A -> B 1

A : 0.00m -0.155 dB
B : 0.00m -0.155 dB

Event Distance Loss Reflect. Slope Section T. Loss


m dB dB dB/km m dB
1 64.16 -55.91 64.16 0.022