User Manual
5 Zone Mixing Amplifier
CE-1070P/1130P/1260P/1360P
                                                         CH1   C H2   CH 3   CH4   CH5
                                                      AUX1             AUX2
User Manual
Please read this user manual carefully before operation.
Performance Feature
  Three M IC input , two AU X input, one AUX output, suit for PA system.
  70V,100V li ne voltage output and 4 Ohm~16Ohm constant resistance
  (balance)output
  MIC 1 has priori ty input a nd mute function
  Individual volume control for MIC and AUX
  Bass and treble control
  Five LED indicators of le vel meter, convenient to monitor the w orking state
  Output short circuit prot ection and alarm
  5 channel port o utput
  This amplifier can be a s mall PA syst em
                                        1
Front panel
                                                                            CH1   CH2   C H3   CH 4   CH5
                                                                     AUX1                AUX2
                                                                                                            9 10
1.Power indicator         2.Power switch                             3.LED level meter
4.Bass control            5.Treble control                           6.MIC volume control
7.AUX 1volume control 8. AUX2 volume control                         9.Priority MIC input
10.Channel button
   Note: When 5 LED indicators are light for long time, it means overload
   distortion. then should turn the volume low till 4 or 5 indicator glinting.
Rear panel
                               CH 1   CH 2   CH 3   CH 4   CH 5
                                             11
  1.Mute control      2.MIC2 &MIC3 input                          3 .AUX1&AUX2 input
  4.AUX output        5.Common output                             6 .4~16Ohm o utput
  7.70V output         8.100V outpu t                             9.AC 220~240V power input
  10.Fuse             11.Channel output port
                                             2
Connection Illustration
                                                      CH 1   C H2   CH 3   C H4   CH 5
                                                  AU X1              AUX2
                                                      CH 1   C H2   CH 3   C H4   CH 5
                                                  AU X1              AUX2
MIC1 has priority input , and MIC1 input signal can
                                                "   restrain
                                                       "     other input signal.
And the restrain degree can be adjusted by the MUTE on the rear panel ,The
range from 0 db ~35db above ,it will be set on the MAX place before leaving
factory.
Safety Notes
1.Be sure to read these notes before using
2.Be sure to comply the most important safety notes of safety symbol and
 message in the manual content.
3.It has electricity in the output port, please operate this equipment under
 the guidance of professionals.
                                         3
 Installation Notes
1.This a mplifier is used in PA system , should be la y in the good ventilation place,
 do not lay in th e surrounding of high tem perature.
2.Do no t expose the equ ipment under the rain or t he surrounding w ith water and
 ot her liquid, so as not t o ca use fire or el ectric shock.
3.Please use un der specified vol tage(AC 200 ~240 V,5 0/60Hz).It m aybe cause
 fire or electric shock when the voltage value higher than the spe cifie d.
4.Do no t cut off or change th e power cabl e, so as not to cause dam age, additional,
 do not let the power ca ble near the heat er, also do not lay the he avy object which
 includ e the equipm ent on the cable. so as n ot to cause f ire or electric shock.
5.After finishing spe aker connec tion, please be s ure t o re cover the protect ion
 cover in the output port. because it can rea ch to 100 V o utput vo ltage in t he
 output port, so do not touch the the se p orts, so a s no t to be elect ric shock . And
  these ports can not as the pow er of other equipments.
6.Do no t ins tall or lay this equipm ent on the locati on of instabi lity, such as
 shaking or skew of the table, le st equipmen t fall ing a nd c ausing injury to persons
 or damage to equipment and property.
7.If the hand is wet, plea se d o not use hand d irect ly to inse rt or pul l out the power
  plug, it m ay cause electric sho ck.
8.If you wan t to pull out the p owe r plug, b e su re to hold the plug, do not hol d cable.
 when the power cable dam aged, using this equi pment m aybe cause fire or
 electric sh ock.
9.If you wan t to move the equipm ent, please be su re t o pull out the plu g from the
 socket.
10.Do n ot block the ventilation pl ace on the e quipment sh ell , otherwise it m ay
 cause internal ove rheating and fire .
11.D o n ot install this equipm ent i n the place w here has humidity, m ore dust, direct
 sunlig ht, heater, soot, vapor, otherw ise it m ay c ause fire and ele ctric shock.
                                              4
Operation Notes
1.This equi pment h as p assed the strict inspection, however, you shou ld turn
  off the power, pull out the power plug w hen discove r som e following ano mali es
  in case, and contact th e dealer.
A.I f sm elled sm oke and peculiar sme ll w hich set out f rom the equipment.
B.I f wa ter or an y metal i mmerge or fa ll into the equipm ent.
C.I f the equipm ent f ell or the she ll da maged.
D.I f the pow er cable dam ag ed.
E.I f the equipm ent f aile d.
F.If the equipme nt distorted badly.
2.This equi pment co ntains h igh voltage com ponents, please do not arbitrarily
  open , so as n ot to cause fi re o r electric shock, if need to maintain, please
  contact d ealer or prof essi onal s to handle
3.Do no t lay liqu id container or m etal on the equi pment top, if they fall into the
  equipment, it may cause f ire or electric shock
4.Do no t fa ll metal or flamm able obje ct in to the ventil ation slot, so as not to
  cause fire or elect ric shock. Do no t touch th e power plug when t hunderin g
  and f ulmi natio n, so as not to cause inju ry of electric sho ck .
5.Do no t lay he avy o bje ct on the equipm ent t op, so as to avoid falling or
  damage, and eve n ca use injury to persons or damage t o equipm ent and
  property, in additi on, heavy ob ject falling itself may cause injury or damage
6.If found voice dist ortion si tuat ion, please do not operate thi s equipm ent for long
  ti me, this is al so a fau lt alarm m ess age, if use unceasingly , it may ca use
  overheati ng and f ire.
7.To cle an e qui pment, please contact wi th the dealer, if the dust accum ulated in
  t he equipmen t fo r long tim e, it ma y cause fire o r damage.
8.Lay t his equipmen t on a stable location, and m ake a approp riate treatment t o
  prevent fa lling , ot herw ise it ma y cause the equipme nt falling, an d cause injury
  to pe rsons or dam age to equipment and property.
9.So as to avoid the inn er temperature to rise , the equipm ent should b e 10
  centimeter fa r from th e barrier.
                                             5
Parameter
Model                          CE-1070P     CE-1130P CE-1260P CE-1360P
Rated Power                    70W          130W        260W       360W
Power Consumption              0.25KVA      0.3KVA      < 0.7KVA   <0.7KVA
Net Weight.                    9.8KG        11KG        12.1KG     14.1KG
Gross Weight                   11.3KG       12.5KG      13.6KG     15.6KG
Fuse Size                      F4AL250V F6AL250V F8AL250V F8AL250V
Dimension                      89mm×483mm× 366mm
Power                          AC200~240V, 50/60Hz
Microphone Input Sensitivity   8-11MV
Line Input                     280MV-320MV
Line Output                    1V± 10%
Frequency Response             60Hz-15KHz(±3dB)
Signal Noise Ratio(SNR)        >70dB
                               ≤2%(80Hz-12.5KHz)
Total Harmonic Distortion(THD) ≤2%(Under Rated Condition,80Hz-12.5KHz)
                               ≤4%(1/100 Rated Power Output ,80Hz-12KHz)
Output Mode                    70V/100V Output ; 4~16ΩOutput
                               When MIC1 has signed input ,
Mute Function
                               other signal attenuate :0~-35dB
Tone Adjust Range              Bass:±dB(100Hz) Treble:±10dB(10KHz)
                                       6
CAUTION:Do not op en the equipment c over ar bitrar ily,
so as not to electric sh ock.P lease c ontact the pr ofessio nals
to maintain if n ecessa ry .
                                CEOPA corporation