SYNCHROTACT 6 Synchronizing Device

The Synchrotact 6 device allows for 20 individual parameter sets to be stored and selected, enabling 20 separate paralleling points to be operated independently. It has inputs for selecting a parameter set or circuit breaker and outputs to control paralleling points. While it can handle 13 inputs and 11 outputs, additional peripheral devices are needed for more parameter sets or paralleling points but are not yet available.

Uploaded by

Žarko Močnik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
96 views1 page

SYNCHROTACT 6 Synchronizing Device

The Synchrotact 6 device allows for 20 individual parameter sets to be stored and selected, enabling 20 separate paralleling points to be operated independently. It has inputs for selecting a parameter set or circuit breaker and outputs to control paralleling points. While it can handle 13 inputs and 11 outputs, additional peripheral devices are needed for more parameter sets or paralleling points but are not yet available.

Uploaded by

Žarko Močnik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

13

1

SYNCHROTACT 6
The twenty-in-one synchronizing device
Specific settings for synchronizing and paralleling are stored The software-driven link between parameter set and
in a parameter set. Devices with twenty parameter sets have paralleling point guarantees the correct assignment of
twenty times the same parameters, with the possibility of the setting values to the related plant components.
individual setting. That way, twenty paralleling points with Maximum 13 binary inputs and 11 relay outputs are available
individual settings may be operated. Firstly, the parameter for the selection. If more parameter sets or paralleling
set or the circuit breaker to be synchronized has to be points are required, peripheral devices must be used, but
selected. Then the synchronizing process can be started. these are not yet available.

%LOGDXI6HLWHGXUFKGLHVHVHUVHW]HQ
6<1&+527$&7
3DUDPHWHUVHW 

5HOD\RXWSXWV
3DUDPHWHUVHW 

3DUDOOHOLQJSRLQWVHOHFWLRQ
͙͙͘

3DUDPHWHUVHW 
3DUDPHWHUVHW 

SHULSKHUDOGHYLFHV
QRW\HWDYDLODEOH
&RQQHFWLRQIRU
3DUDPHWHUVHW 
3DUDPHWHUVHW 

 ͙͙͘

%LQDU\LQSXWV

3DUDPHWHUVHW
3DUDPHWHUVHWVHOHFWLRQ

͙͙͘ 3DUDPHWHUVHW 




SHULSKHUDOGHYLFHV
QRW\HWDYDLODEOH
&RQQHFWLRQIRU

͙͙͘



6

Parameter set and paralleling point selection


Control options
Maintenance control for commissioning and servicing Operating control for normal synchronizing operation
• Built-in Maintenance Control Panel (MCP) • Digital inputs/outputs: conventional wiring (standard)
• SynView 6 PC-tool • Communication interfaces: IEC 61850 electrical or optical;
Modbus RTU; Profibus DP (option)