GENERAL INFORMATION
GENERAL SPECIFICATIONS
ENGINE MODEL L5774LT/L5794LT L5794GSI L7044GSI
Intake Manifold Temperature
Up to 10°F (-12°C) above design intercooler water inlet
Normal:
temperature
GSI & LT engines
Alarm: ESM-monitored
Shutdown: ESM-monitored
Intake Manifold Pressure
Contact Waukesha Sales Engineering Department
Fuel System
Natural gas pressure at 35 – 50 psig (241 – 345 kPa)**
24 – 50 psi (165 – 345 kPa)
regulator 43 – 60 psig (296 – 414 kPa)***
Natural gas pressure at
regulator “Low Fuel Pressure” 6 in. (152 mm)
models
FORM 6319-2
1.15-15 © 8/2012