Certificate of Fire Approval: Manufacturer Roxtec International AB

This document is a certificate of fire approval for Roxtec International AB's Pipe Penetration (Standard Fire Test), specifically their "Roxtec SPM Seal" product. The certificate certifies that Lloyd's Register has appraised the product and deemed it acceptable on ships and offshore installations in compliance with SOLAS and LR rules. It is approved for use in A-Class steel and aluminum bulkheads and decks. The certificate is valid for 5 years until July 2025, provided the product remains satisfactory in service and no changes are made to the approved design.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
147 views

Certificate of Fire Approval: Manufacturer Roxtec International AB

This document is a certificate of fire approval for Roxtec International AB's Pipe Penetration (Standard Fire Test), specifically their "Roxtec SPM Seal" product. The certificate certifies that Lloyd's Register has appraised the product and deemed it acceptable on ships and offshore installations in compliance with SOLAS and LR rules. It is approved for use in A-Class steel and aluminum bulkheads and decks. The certificate is valid for 5 years until July 2025, provided the product remains satisfactory in service and no changes are made to the approved design.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Page 1 of 11

Certificate No: LR2006428SF


Issue Date: 08/07/2020
Expiry Date: 07/07/2025

Certificate Of Fire Approval


This is to certify that the product detailed below will be accepted for compliance with the applicable Lloyd's Register
Rules and Regulations and with the International Convention for the Safety of Life at Sea, (SOLAS), 1974, as
amended, for use on ships and offshore installations classed with Lloyd's Register, and for use on ships and offshore
installations when authorised by contracting governments to issue the relevant certificates, licences, permits etc.

Manufacturer Roxtec International AB


Address Rombvägen 2, Box 540, S-371 23 Karlskrona, Sweden

Type Pipe Penetration (Standard Fire Test)

Description Fire Resisting Single Metallic Pipe Circular Penetrations– Type: “Roxtec SPM
Seal” for applications in A Class steel and aluminium bulkheads and decks

Trade Name Roxtec SPM Seal

Specified Standard IMO Res. MSC.307 (88) - (2010 FTP Code) Annex 1, Part 3
IMO MSC.1/Circ.1488

This certificate is not valid for equipment, the design or manufacture of which has been varied or modified from the
specimen tested. The manufacturer should notify Lloyd's Register EMEA of any modification or changes to the
equipment in order to obtain a valid Certificate.

The Design Appraisal Document and its supplementary Type Approval Terms and Conditions form part of this
Certificate.

This certificate remains valid unless cancelled or revoked, provided the conditions in the attached Design Appraisal
Document are complied with and the equipment remains satisfactory in service.

Saji Abraham
Surveyor to Lloyd's Register EMEA
71 Fenchurch Street, London, EC3M 4BS, United A member of the Lloyd's Register Group
Kingdom

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.

TA02 1.0.0
Page 2 of 11
Certificate No: LR2006428SF
Issue Date: 08/07/2020
Expiry Date: 07/07/2025
Reference: UKITSO/FIRE/TA/SA/WP35151560

ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. LR2006428SF

The undernoted documents have been appraised for compliance with the relevant requirements of International
Conventions.

This Design Appraisal Document forms part of the Certificate.

This certificate is a renewal and amendment of SAS F160195/M1

EXAMINED DOCUMENTATION

SP Technical Research Institute of Swedaen, Boras, Sweden; Fire Test Reports No: 5P03451 dated 3 November 2015,
5P03457 dated 12 November 2015, 5P08346 dated 21 December 2015, 5P08343 dated 21 December 2015 and 5P08395
dated 17 March 2016, 6P05989 and 6P05989 both dated 24 October 2016 and 6P07565 dated 20 December 2016.
Danish Institute of Fire and Security Technology, Hvidovre, Denmark; Fire test report No: PGA10870A dated 13 December
2016.
Ship Design and Research Centre S.A. (CTO), Gdansk, Poland; Fire test reports No: RS-17/B-209/E and RS-17/B-210/E both
dated 2 June 2017, RS-18/B-179/E and RS-18/B-180/E both dated 25 June 2018
Manufacturer’s guidance drawings No: S1513650A, S1513651A, S1513652C and S1513653A (for steel divisions) and
S1536362A dated 4 October 2018, S1536464A dated 7 April 2020, S1536485A and S1536486A both dated 17 April 2020 (for
aluminium divisions). Note: Manufacturer drawings are for reference purposes only; product applications to be in
accordance with Conditions of Certification below

CONDITIONS OF CERTIFICATION

1. For applications in A-60 Class steel bulkheads and decks, with approved insulation arrangements as described in
Tables 1 and 2 below and also generally in accordance with manufacturer’s guidance drawings No: S1513650A,
S1513651A, S1513652C and S1513653A. Final insulation arrangements onboard are to be approved by the relevant
project authority on a case-by-case basis
2. All “SPM Series” pipe seals were tested only in A-60 Class steel divisions, but not separately in A-0 Class steel divisions
in accordance with IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1, Part 3 Appendix 2. A.III.2.2.1.1 Therefore for
applications in A-0, A-15 and A-30 Class steel bulkheads and decks, they shall be fitted with the same or equivalent A-
60 Class insulation arrangements as those used in the fire tests (including any insulation fitted on the penetration itself
in the tests) for a minimum distance of 200mm around the penetration, on all fire risk sides of bulkheads and decks (as
identified by the Design Plan Approval Authority for each project) and insulation should be extended to cover the full
side(s) and the end face(s) of the steel frame, with an overlap of at least 20mm from the steel end plate edges. The
above mentioned A-60 Class insulation arrangements should be additional to any thermal or acoustic insulation, but
may include any fire rated insulation (e.g. A-15, or A-30) already fitted on the bulkhead or deck and/or on the
penetration itself, such that the total fire rating is A-60
3. For applications in A-60 equivalent aluminium bulkheads and decks, with approved insulation arrangements as
described in Tables 3 and 4 below and also generally in accordance with manufacturer’s guidance drawings No:
S1536362A dated 4 October 2018, S1536464A dated 7 April 2020, S1536485A and S1536486A both dated 17 April 2020.
Final insulation arrangements onboard are to be approved by the relevant project authority on a case-by-case basis

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
Page 3 of 11
Certificate No: LR2006428SF
Issue Date: 08/07/2020
Expiry Date: 07/07/2025
Reference: UKITSO/FIRE/TA/SA/WP35151560

ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. LR2006428SF

4. Aluminium bulkheads and decks in all cases must be insulated with an approved system to prevent the core
temperature exceeding 2000c and all pipe penetrations fitted to such divisions shall also be insulated with either the
same system or an approved A-60 system
5. Roxtec “SPM Series” pipe seals consist of: stainless steel circular plates fitted to the front and rear ends of the “Roxylon”
rubber seal unit and secured using 5 stainless steel bolts and nuts fitted through the front and rear end plates and the
“Roxylon” rubber seal unit. The “SPM” pipe seal unit is fitted around the pipes and secured to the steel bulkhead or
deck by expansion of the rubber seal fitted through the aperture in bulkhead or deck plate, when the bolts are
tightened. Constructional details of the Roxtec “SPM Series” pipe seals are to be as described in Roxtec drawing:
S1502970 Rev. D
6. Approved arrangements for Roxtec “SPM Series” pipe seals in A-60 Class steel and aluminium bulkheads and decks are
as described in Tables 1 & 2 and 3&4 below respectively
7. Type Approval is limited to the as-tested SPM pipe penetration seals only, for use with the specific size or size range of
each type of pipe tested as described in the Tables. Intermediate size SPM seals within the tested range may only be
accepted subject to final approval from the design project authority, provided they are fitted with at least the same
insulation arrangements as the next greater size seal approved in the Tables (for example, seals larger than SPM 81 in
Table 1 must be fitted with at least the same insulation arrangements approved for SPM 138) and the size of the
penetrating pipe being proportional to the size of the specific intermediate penetration, which may be determined by
linear interpolation
8. Production items are to be manufactured in accordance with a quality control system which shall be maintained to
ensure that items are of the same standard as the approved prototype
9. The certificate holder is solely responsible for the products supplied under this Certificate and to ensure that their
products, whether manufactured by themselves or their licensee manufacturers, if agreed by Lloyd's Register, are fully
compliant with the relevant statutory regulations and Lloyd's Register Class rules as applicable and designed and
manufactured to the same quality and specifications as the prototype tested, including components that are designed
and manufactured by third parties

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
Page 4 of 11
Certificate No: LR2006428SF
Issue Date: 08/07/2020
Expiry Date: 07/07/2025
Reference: UKITSO/FIRE/TA/SA/WP35151560

ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. LR2006428SF

Table 1: Approved arrangements in A-60 Class Steel Bulkheads


Minimum
Minimum
thickness/length of as-
diameter of as-
tested or equivalent A-
tested or
60 insulation to be
Position of equivalent A-60
Tested Pipe fitted along the pipe on
Maxi- SPM seal in insulation Collar
Nominal single side or both
Pipe mum bulkheads/ required around
Seal Outside sides of bulkhead as
Material Fire General(a) or the penetration,
Diameter applicable, when
rating Restricted(b) on single side or
(in mm) measured from the
Applications both sides of
Penetration insulation
bulkhead as
collar (if applicable) or
applicable (in
bulkhead insulation (in
mm).
mm).
Fire exposed
side or Fire
SPM 39 12 Steel A-60 unexposed Not required 50/300 (Single side)
side (General
Applications)
Fire exposed
side or Fire
SPM 41 12 Steel A-60 unexposed Not required 50/300 (Single side)
side (General
Applications)
Fire exposed
side or Fire
SPM 81 45.4 Steel A-60 unexposed Not required 50/300 (Single side)
side (General
Applications)
Fire
unexposed
side
SPM 138 92 Steel A-60 200 (Single side) 50/400 (Single side)
(insulated
side)/Restricte
d applications
Fire exposed
side or Fire
SPM 279 220 Steel A-60 unexposed 200 (Both sides) 100/500 (Both sides)
side (General
Applications)

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
Page 5 of 11
Certificate No: LR2006428SF
Issue Date: 08/07/2020
Expiry Date: 07/07/2025
Reference: UKITSO/FIRE/TA/SA/WP35151560

ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. LR2006428SF

Table 1: Approved arrangements in A-60 Class Steel Bulkheads (Continued)


Fire exposed side
SPM Coppe or Fire unexposed
12 A-60 Not required 50/300 (Single side)
39 r side (General
Applications)
Fire exposed side
SPM Coppe or Fire unexposed 100 (Single
12 A-60 50/400 (Single side)
41 r side (General side)
Applications)
Fire exposed side
SPM Coppe or Fire unexposed 100 (Single
45 A-60 50/400 (Single side)
81 r side (General side)
Applications)
Fire exposed side
SPM Coppe or Fire unexposed 200 (Single
90 A-60 50/600 (Single side)
138 r side (General side)
Applications)
Fire exposed side
SPM Coppe or Fire unexposed 200 (Both
220 A-60 100/700 (Both sides)
279 r side (General sides)
Applications)

(a) General applications refer to installation arrangements where the penetrations are accepted for use on any one side
(fire exposed side or fire unexposed side) of the bulkhead.
(b) Restricted applications refer to installation arrangements where the penetrations are accepted for use on the fire
unexposed, insulated side of the bulkhead in all cases.

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
Page 6 of 11
Certificate No: LR2006428SF
Issue Date: 08/07/2020
Expiry Date: 07/07/2025
Reference: UKITSO/FIRE/TA/SA/WP35151560

ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. LR2006428SF

Table 2: Approved arrangements in A-60 Class Steel Decks


Seal Tested Pipe Pipe Maxi- Position of SPM Minimum diameter Minimum
Nominal Material mum Fire seal in of as-tested or thickness/length of
Outside Rating Decks/General(a) equivalent A-60 as-tested or
Diameter or Restricted(b) Class Insulation equivalent A-60 Class
(in mm) Applications Collar required insulation to be fitted
around the along the pipe on the
penetration on the underside, topside or
underside, topside both sides of deck as
or both sides of applicable, when
deck as applicable measured from the
of decks as penetration
applicable (in mm). insulation collar or
deck insulation as
applicable (in mm).
Fire exposed
SPM underside
8 to 12 Steel A-60 Not required Not required
39 (Restricted
Applications)
SPM 12 Steel A-60 Fire exposed Not required Not required
41 underside or
Fire unexposed
side (General
Applications)
SPM 30 Steel A-60 Fire exposed Not required Not required
62 underside or
Fire unexposed
side (General
Applications)
SPM 36 Steel A-60 Fire exposed Not required Not required
69 underside or
Fire unexposed
side (General
Applications)
SPM 45.4 Steel A-60 Fire exposed Not required 50/300 (Underside)
81 underside or
Fire unexposed
side (General
Applications)

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
Page 7 of 11
Certificate No: LR2006428SF
Issue Date: 08/07/2020
Expiry Date: 07/07/2025
Reference: UKITSO/FIRE/TA/SA/WP35151560

ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. LR2006428SF

SPM 92 Steel A-60 Fire exposed Not required 50/400 (Underside)


138 underside or
Fire unexposed
side (General
Applications)
SPM 220 Steel A-60 Fire exposed Not required 100/600 (Underside)
279 underside or
Fire unexposed
side (General
Applications)
Fire exposed
SPM underside
8 to 12 Copper A-60 Not required 50/400 (Underside)
39 (Restricted
Applications)
SPM 12 Copper A-60 Fire exposed Not required 50/400 (Underside)
41 underside or
Fire unexposed
side (General
Applications)
SPM 16 Copper A-60 Fire exposed Not required 50/400 (Underside)
41 underside
(Restricted
Applications)
SPM 45.4 Copper A-60 Fire exposed Not required 100/800 (Underside)
81 underside or
Fire unexposed
side (General
Applications)
SPM 92 Copper A-60 Fire exposed 100 (underside) 100/800 (Underside)
138 underside or
Fire unexposed
side (General
Applications)
SPM 143 Copper A-60 Fire exposed 100 (underside) 100/800 (Underside)
196 underside
(Restricted
Applications)
SPM 171 Copper A-60 Fire exposed Not Required 100/1200 (Underside)
226 underside
(Restricted
Applications)

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
Page 8 of 11
Certificate No: LR2006428SF
Issue Date: 08/07/2020
Expiry Date: 07/07/2025
Reference: UKITSO/FIRE/TA/SA/WP35151560

ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. LR2006428SF

SPM 222 Copper A-60 Fire unexposed Not required 100/700 (Both sides)
279 side(topside)/R
estricted
Applications
SPM 222 Copper A-60 Fire exposed Not Required 100/1200 (Underside)
279 underside
(Restricted
Applications)

(a) General applications refer to installation arrangements where the penetrations are accepted for use on any one side
(fire exposed side or fire unexposed side) of a steel deck, which is insulated on the fire exposed underside in all cases.
(b) Restricted applications refer to installation arrangements where the penetrations are accepted for use only on one
specific side (fire exposed side or fire unexposed side) of a steel deck, depending on the tested configuration as
described in the Table , with the steel deck insulated on the fire exposed underside in all cases.

Table 3: Approved arrangements in A-60 Class equivalent aluminium bulkheads

Minimum thickness/length
Tested of as-tested or equivalent A-
Pipe Maxi- 60 insulation to be fitted
Position of SPM seal in
Nominal Pipe mum along the pipe on single side
Seal bulkheads/
Outside Material Fire or both sides of bulkhead as
General Applications (a)
Diameter rating applicable, when measured
(in mm) from the bulkhead insulation
(in mm).
Fire exposed side or Fire
SPM 39 8 Steel A-60 unexposed side 50/300 (single side)
(General Applications)
Fire exposed side or Fire
SPM 81 45.4 Steel A-60 unexposed side 50/300 (single side)
(General Applications)
Fire exposed side or Fire
SPM 87 51 Steel A-60 unexposed side 50/400 (single side)
(General Applications)
Fire exposed side or Fire
SPM 138 92 Steel A-60 unexposed side 50/400 (single side)
(General Applications)
Fire exposed side or Fire
SPM 149 103 Steel A-60 unexposed side 100/500 (both sides)
(General Applications)

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
Page 9 of 11
Certificate No: LR2006428SF
Issue Date: 08/07/2020
Expiry Date: 07/07/2025
Reference: UKITSO/FIRE/TA/SA/WP35151560

ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. LR2006428SF

Fire exposed side or Fire


SPM 279 222 Steel A-60 unexposed side 100/500 (both sides)
(General Applications)
Fire exposed side or Fire
SPM 39 8 Copper A-60 unexposed side 50/400 (single side)
(General Applications)
Fire exposed side or Fire
SPM 81 45.4 Copper A-60 unexposed side 50/400 (single side)
(General Applications)
Fire exposed side or Fire
SPM 87 51 Copper A-60 unexposed side 50/500 (single side)
(General Applications)
Fire exposed side or Fire
SPM 138 92 Copper A-60 unexposed side 50/500 (single side)
(General Applications)
Fire exposed side or Fire
SPM 149 103 Copper A-60 unexposed side 100/600 (single side)
(General Applications)
Fire exposed side or Fire
SPM 157 110 Copper A-60 unexposed side 100/600 (single side)
(General Applications)

(a) General applications refer to installation arrangements where the penetrations are accepted for use on any one side
(fire exposed side or fire unexposed side) of the bulkhead.

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
Page 10 of 11
Certificate No: LR2006428SF
Issue Date: 08/07/2020
Expiry Date: 07/07/2025
Reference: UKITSO/FIRE/TA/SA/WP35151560

ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. LR2006428SF

Table 4: Approved arrangements in A-60 Class equivalent aluminium decks

Minimum thickness/length of as-


Tested tested or equivalent A-60 Class
Pipe Maxi- Position of SPM insulation to be fitted along the pipe
Nominal Pipe mum seal in on the underside, topside or both
Seal
Outside Material Fire Decks/Restricted sides of deck as applicable, when
Diameter Rating Applications(a) measured from the penetration
(in mm) insulation collar or deck insulation
as applicable (in mm).
Fire exposed
underside
SPM 39 8 Steel A-60 Not required
(Restricted
Applications)
Fire exposed
underside
SPM 81 45.4 Steel A-60 50/300 (Underside)
(Restricted
Applications)
Fire exposed
underside
SPM 87 47 Steel A-60 50/400 (Underside)
(Restricted
Applications)
Fire exposed
underside
SPM 138 92 Steel A-60 50/400 (Underside)
(Restricted
Applications)
Fire exposed
underside
SPM 149 103 Steel A-60 100/600 (Underside)
(Restricted
Applications)
Fire exposed
underside
SPM 279 222 Steel A-60 100/600 (Underside)
(Restricted
Applications)
Fire exposed
underside
SPM 39 8 Copper A-60 50/400 (Underside)
(Restricted
Applications)
Fire exposed
underside
SPM 157 110 Copper A-60 100/600 (Underside)
(Restricted
Applications)

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
Page 11 of 11
Certificate No: LR2006428SF
Issue Date: 08/07/2020
Expiry Date: 07/07/2025
Reference: UKITSO/FIRE/TA/SA/WP35151560

ATTACHMENT TO CERTIFICATE OF TYPE APPROVAL No. LR2006428SF

(a) Restricted applications refer to installation arrangements where the penetrations are accepted for use only on one
specific side (fire exposed side or fire unexposed side) of a steel deck, depending on the tested configuration as
described in the Table, with the steel deck insulated on the fire exposed underside in all cases.

NOTES (For Information only; outside the scope of Fire Type Approval Certification)

1. Single “SPM Series” Pipe penetration seals, types: “SPM 41”, “SPM 81”, “SPM 138” and “SPM 279” were subjected to a
hydrostatic pressure of 1.5 bar for a period of 60 minutes with no leakage, followed by a helium gas pressure test at 1
bar for a period of 30 minutes with no leakage, as detailed in DNV-GL Reports No. N1417RRN dated 29 January 2016
and N1419WS4 dated 22 June 2016.
2. Roxtec SPM 39 seal with a single steel pipe of outer diameter 8mm, mounted in 4mm and 15mm thick steel plates, was
subjected to a 60minutes watertightness test at 1.5bar followed by a 30minutes helium gas tightness test at 1bar, with
the pressure applied from different sides of the seal, and no leakage was reported for the full test duration, as described
in DNV-GL Survey Report No: N141805A dated 20 December 2016 and associated Test Report TST-000505.
3. The above-mentioned Pipe penetration seals may be considered to prevent flooding or maintain gastight
requirements on a ship approval basis. These types of penetrations are not suitable for tank boundaries and where the
penetrations are subject to frequent immersion in fluids and are not suitable for applications identified in SOLAS,
Chapter II-1, Regulation 13.2.3 for “Openings in watertight bulkheads below the bulkhead deck in passenger ships.”

PLACE OF PRODUCTION

Roxtec International AB
Box 540
S-371 23 Karlskrona
Sweden

Saji Abraham
Senior Specialist
Fire & Safety, Statutory Discipline Team
UK&I Technical Support Office, Marine & Offshore
Lloyd's Register EMEA

Supplementary Type Approval Terms and Conditions


This certificate and Design Appraisal Document relates to type approval, it certifies that the prototype(s) of the product(s)
referred to herein has/have been found to meet the applicable design criteria for the use specified herein, it does not mean
or imply approval for any other use, nor approval of any products designed or manufactured otherwise than in strict
conformity with the said prototype(s).

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.