Capitol 9 ETHERNET: Logical Link Control (LLC
Capitol 9 ETHERNET: Logical Link Control (LLC
Standards for LANs start with the number 802. The standard for Ethernet is 802.3.
Logical Link Control (LLC)
Data Encapsulation
Frame delimiting
Addressing
Error detection
Acesta formeaza sau dezasambleaza frameul
MAC layer adauga headerul & trailerul la PDU din Layer3
Incapsularea permite adaugarea de adresa MAC pentru livrare
Procesul de creare a frameurilor e benefic pentru sincronizare
Trailerul contine CRC pentru Error correction
Frame pt ethernet
2 modele:
DIX Ethernet standard (Ethernet II)
IEEE 802.3
Dimensiunea de 64 B-> 1518 B
Preamble (7 bytes) & Start Frame Delimiter (SFD) (1 byte) sunt folosite pentru
sincronizare. Atrag atentia destinatarului ca urmeaza sa primeasca un frame.
Destination MAC Address field (6 bytes)
Source MAC Address field (6 bytes)
Length/Type Field –lungimea segmentului Data
Data and Pad fields (46 - 1500 bytes) contine datele incapsulate pentru layerele
superioare. Frame-ul trebuie sa fie minim 46B, altfel se completeaza
Frame Check Sequence (FCS) field (4 bytes)-detectia de erori, foloseste CRC
Adresa MAC
Adresa unica data de IEEE, cod 3 bytes ce formeaza Organizationally Unique Identifier (OUI).
Numita si burned-in address (BIA) – se scrie in ROM
IEEE requires a vendor to follow two simple rules:
All MAC addresses assigned to a NIC or other Ethernet device must use that vendor's
assigned OUI as the first 3 bytes.
All MAC addresses with the same OUI must be assigned a unique value (vendor code or
serial number) in the last 3 bytes.
Network layer address enables the packet to be forwarded toward its destination.
Data Link layer address enables the packet to be carried by the local media across each
segment.
Unicast MAC address is the unique address used when a frame is sent from a single
transmitting device to single destination device.
Multicast -multicast addresses allow a source device to send a packet to a group of devices.
Multi-access- din cauza distantei dintre device-uri, unul dintre acestea se poate sa nu detecteze
transmisia altuia si sa emita la randul lui un mesaj, cele 2 mesaje se intalnesc pe media si se
ciocnesc iar resturile mesajelor se transmit in continuare
In half-duplex mode, daca o coliziune nu a avut loc, deviceul ce vrea sa transmita va emite un
semnal de 64b de informatie pt sincronizare(PREAMBLE),apoi va transmite frame-urile ramase.
Backoff Timing- timpul de asteptare de dupa coliziune, este mai mare pentru
device-ul care a creat coliziunea