100% found this document useful (1 vote)
362 views48 pages

Construction of Workstations at The Main Market-Capital Projects 2018

This document provides a bill of quantities for the construction of a 3-bedroom house with sewer reticulation. It includes items for excavation and earthworks, substructure, superstructure, roofing, doors and windows, finishes, and external works. The quantities, units, rates and costs are provided for each item, with a total cost calculated at the end. Key items include excavations, concrete foundations, blockwork walls, structural concrete ring beams and slabs, roof trusses and iron sheets, plumbing works, electrical installations, and finishes like plastering and painting.

Uploaded by

Eng Hinji Rudge
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
362 views48 pages

Construction of Workstations at The Main Market-Capital Projects 2018

This document provides a bill of quantities for the construction of a 3-bedroom house with sewer reticulation. It includes items for excavation and earthworks, substructure, superstructure, roofing, doors and windows, finishes, and external works. The quantities, units, rates and costs are provided for each item, with a total cost calculated at the end. Key items include excavations, concrete foundations, blockwork walls, structural concrete ring beams and slabs, roof trusses and iron sheets, plumbing works, electrical installations, and finishes like plastering and painting.

Uploaded by

Eng Hinji Rudge
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 48

ITEM VARRIATIONAL ORDER WORKS QTY UNIT RATE AMOUNT

BLOCKWORK - DWARF WALL

Precast concrete hollow blocks (3.5 N/mm2) as


described filled solid with plain concrete mix
20/20 bedded end pointed in cement sand mortar

100mm concrete blocks constructed as 1.1m height


A dwarf wall 80 m2 80 6,400.00

Sundries

B 1.0M brick force bedded in every three courses 136 m 4 544.00

C 1.0M damp proof course 72 m 2 144.00

Finishings

D 19mm thick cement sand (1:3) plaster to


concrete block wall 160 m2 21 3,360.00

BRICKWORK -WORK STATION

Hand made Burnt bricks of crushing strength


(0.15N/mm2) -AA class as described in cement
motar (1:4)

150mm burnt bricks constructed at 1.1m height wall to


E support workstations 200 m2 70 14,000.00

Sundries

"Brickforce" or other equal and approved brick


reinforcement cement as described (no
allowance made for laps)

F 1.5M brick force bedded in every three courses 340 m 3 1,020.00

Three ply bituminous felt proof course and laying as


described (no allowance made for laps)

G 1.5M damp proof course 181 m 5 905.00

Finishings

H 19mm thick cement sand (1:3) plaster to


concrete block wall 400 m2 22 8,800.00

To Collection K 35,173.00

BRICKWORK -WORKSTATION/BLOCKWORK DWARF


WALL - TOTAL CARRIED TO SUMMARY K 35,173.00

Kabompo Town Council 1/1 Works Department


ITEM VARRIATIONAL ORDER WORKS QTY UNIT RATE AMOUNT

CONCRETE WORK

PREAMBLE

Concrete cover to main reinforcement is to be


and 25mm for workstations etc. Maximum size
of aggregate is to be 20mm

REINFORCED IN-SITU CONCRETE

Reinforced concrete C25/20 as described

A 100mm thick workstations 12 m3 1,194 14,328.00

High yield steel bar reinforcement as described


including all cutting, bending, hooking and cranking,
assembling etc. In accordance with the drawings and
wiring with and including No.16 annealed iron binding
with and hoisting and low ering and fixing in position

12mm rebar for workstations spaced @ 150mm


B bothways 1580 m 16 25,280.00

Sawn formwork to reinforced concrete to


produce a smooth finish as described including fixing,
with wire nails

200x25mm SW timber exceeding 100mm but not


C exceeding 200mm wide to edges of workstations 237 m 41 9,717.00

D Solid panel boards to Soffits of workstation 92 m2 144 13,248.00

E 50X50mm timber struts to support soffits of workstation 205 m 30 6,150.00

CONCRETE WORK - TOTAL


CARRIED TO SUMMARY K 68,723.00

Kabompo Town Council 1/2 Works Department


ITEM VARRIATIONAL ORDER WORKS QTY UNIT RATE AMOUNT

PAINTING AND DECORATING

Painting - Dwarf wall

Prepare and apply one undercoat and three coats of


clear PVA as described

A Colorite Dove grey PVA paint to Plastered walls 160 m2 22 3,520.00

B Bituminous paint to plastered walls <400mm 76 m 20 1,520.00

Painting - Workstations

Prepare and apply one undercoat two coats of white


gloss oil paint as described, paint accessories
inclusive in the rates

50mm thick linning On workstations as stand


demarcation and stand numbering-refer to stand
D layout drawing for demarcations 18 m2 53 954.00

To Collection K 5,994.00

PAINTING AND DECORATING -


TOTAL CARRIED TO SUMMARY K 5,994.00

Kabompo Town Council 1/3 Works Department


ITEM VARRIATIONAL ORDER WORKS QTY UNIT RATE AMOUNT

DRAINAGE (ALL PROVISIONAL)

Spoon Drain

A Spoon drain size 750mm x 250mm deep in concrete


bricks with sides dished to falls and including 150mm
laterite bed with sand blinding and pointing in
1:3 C/S mortar, all necessary excavations, fillings
and disposal 78 m 150.00 11,700.00

EXTERNAL DRAINAGE - TOTAL


CARRIED TO SUMMARY
K 11,700.00

Kabompo Town Council 1/4 Works Department


ITEM VARRIATIONAL ORDER WORKS QTY UNIT RATE AMOUNT

STRUCTURAL STEELWORK

Bracing

Supply and install structural steelwork as bracing for


the Market portal frames as directed by the Engineer,
prices to include all accessories, welding and primer
painting of structural steelwork

A 50X50mm angle bars 66 m 45.00 2,970.00

STRUCTURAL STEELWORK
CARRIED TO SUMMARY
K 2,970.00

Kabompo Town Council 1/5 Works Department


ITEM VARRIATIONAL ORDER WORKS QTY UNIT RATE TOTAL

SUMMARY FOR THE WORKS

GENERAL SUMMARY

BRICKWORK/BLOCKWORK K 35,173.00

CONCRETE WORK K 68,723.00

PAINTING AND DECORATION K 5,994.00

DRAINAGE K 11,700.00

STRUCTURAL STEELWORK K 2,970.00

K 124,560.00

Kabompo Town Council 1/6 Works Department


BILL No.2 -CONSTRUCTION OF A STAFF HOUSE

FINANCIA: GRZ-CONSTITUENCY DEVELOPMENT FUND, 2014

IMPLIMENTER: MLGH-MUFUMBWE DISTRICT COUNCIL

BENEFICIALLY: MOE-SHUKWE WEST COMMUNITY SCHOOL

LOCATION FORM CBD: 15KM


CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

SUBSTRUCTURE - ALL PROVISIONAL

Preamble

The substructure has been measured up


to an including the concrete floor slab

The site is assumed to be level and the


substructure has been measured accordingly

The top of the ground floor slab is assumed


to be 300mm above existing ground level

The top of the concrete foundation to external


walls and main cross walls is assumed to be
1000mm below existing ground level

Unless otherwise stated, all excavations shall


be in pickable material and including excavating
for working space where applicable

The term "reduced level" shall mean the ground


level after removal of vegetable soil or the
surface level of any filling required

The Quantities of excavation and disposal


within this bill will be found to balance, The
Contractor is to allow in his rates for forming
temporary spoil heaps, multiple handling etc.
as required

The Contractors attention is directed to


PREAMBLE Notes proceeding work section
in the Superstructure Bills. Such notes are
to apply equally to similar work contained in
this substructure Bill

Clearing of the site has been measured in


the the External Works Bill

To Collection K

4/8
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

EXCAVATIONS AND EARTHWORK CON'TD

A Search for and excavate as necessary and remove


ants, nests, treat with approval white fumigant,
fill in with approved imported fill, well watered
and consolidated in layers not exceeding
150mm thick and cart away surplus excavated
materials Item

B Ant treatment to whole of surface of excavations,


top of hardcore bed and foundation walls with
"Dieldrin 15" as described 10 m2

C Excavate oversite 100mm deep to remove


top soil and wheel to spoil or distance not
exceeding 200 metres 154 m2

EXCAVATION

D Excavate trench to receive foundation


commencing at reduced level and not exceeding
1.50 metres deep 33 m3

E Extra over excavating in hard rock as described 5 m3

F Backfilling around foundation 22 m3

G Disposal of excavated materials off site 11 m3

H Levelling and compacting bottoms of excavations 41 m2

J 50mm thick sand blinding to bottoms of excavations 41 m2

K Keep all excavations free from general water item

L Provide all necessary planking and strutting


to faces of excavations as described Item

To Collection K

4/9
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

EXCAVATIONS CON'TD

Hardcore Filling

A 150mm bed hardcore laid and consolidated


as described 101 m2

B Form sinking battered sides 410 (average)


x 125mm deep and hand packing as described 4 m

Sand blinding

C Sand blinding on top of the hardcore 101 m2

CONCRETE WORK

Plain concrete grade 20 as described

D Foundations in trenches 9 m3

Reinforced concrete grade 25 as described

E 100mm slab bed laid level 101 m2

F In slab thickening 525 (average) 125mm deep 4 m

Steel fabric reinforcement to BS 4483 (1969)

G "Conforce" reference 86 or other equal and


approved fabric reinforcement with 150mm
side and end laps 101 m2

K 500 gauge polythene damp proof membrane laid on


blinded hardcore with 150mm double taped side and
end laps with approved adhesive tape both sides
(no allowance made for laps) 101 m2

To Collection K

4/10
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

BRICKWORK AND BLOCKWORK

Precast concrete hollow blocks type A (5.0) as


described filled solid with plain concrete mix
20/20 bedded end pointed in cement sand mortar

A 150mm wall 58 m2

Sundries

B 1.5M brick force bedded in every two courses 87 m

Finishings

C 19mm thick cement sand (1:3) plaster to


concrete block wall plinth 34 m2

Painting and Decorating

D Prepare and apply three coats of black


bituminous paint on plastered plinth exceeding
200mm but not exceeding 300mm 34 m2

To Collection K

COLLECTION

Page No 4/2 K

Page No 4/3 K

Page No 4/4 K

SUBSTRUCTURE - TOTAL
CARRIED TO SUMMARY K

4/11
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

CONCRETE WORK

PREAMBLE
Concrete cover to main reinforcement is to be
and 25mm for beams etc. Maximum size
of aggregate is to be 20mm

PLAIN IN-SITU CONCRETE

A 100 x 100 up stand shower edge 1 m

REINFORCED IN-SITU CONCRETE

Reinforced concrete 25/20 as described

B Ring beam and lintols 2 m3

C 100mm thick suspended slab 8 m2

D 250 x 75mm precast concrete window sill with a slant


of 10o on the outside 12 m

High yield steel bar reinforcement as described


including all cutting, bending, hooking and cranking,
assembling etc. In accordance with the drawings and
wiring with and including No.16 annealed iron binding
with and hoisting and low ering and fixing in position

E 12mm bar in beam and lintol 182 kg

F 10mm bar in beam and lintol 8 kg

G Conforce mesh type 86 fabric reinforcement with


150mm side and end laps including all necessary
tying wire and distance blocks (measured net, no 8 m2
allowance made for laps)

Sawn formwork to reinforced concrete to


produce a smooth finish as described

H To soffits of suspended slabs 8 m2

J To edges of suspended slab exceeding 100mm not

4/12
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

exceeding 200mm wide 6 m

K Sides and soffits of ring beams and lintols 26 m2

CONCRETE WORK - TOTAL


CARRIED TO SUMMARY K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

BRICKWORK AND BLOCKWORK

Preamble

Precast concrete hollow blocks type A


(2.5N/mm2) as described in cement mortar
(1:4)

A 150mm wall 270 m2

B 100mm wall 76 m2

C Rough raking cutting 150mm block 71 m

Three ply bituminous felt proof course and laying as


described (no allowance made for laps)

D 150mm wide 20 m

E 100mm wide 20 m

"Brickforce" or other equal and approved brick


reinforcement cement as described (no
allowance made for laps)

F 150mm wide ditto built into 150mm block wall 355 m

G 100mm wide ditto built into 100mm block wall 100 m

Airbricks

H Air bricks comprising 230 x 190mm square


hole pattern precast concrete outer grille with
copper gauze from hole in 200mm blockwall
and render assumed in cement mortar (1:4)
and plastic 230 x 190mm inner grille and
make good plaster around (Provisional) 16 No.

BRICKWORK AND BLOCKWORK


TOTAL CARRIED TO SUMMARY K

4/13
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ROOFING

Asbestos Cement Endurite roofing sheets with approved


end side lapping, fixed in accordance with
manufacturer's recommendations as described

A Roof sheets fixed to soft wood purlins 162 m2

B Ridge capping 12 m

C End finials 2 No.

ROOFING - TOTAL CARRIED


TO SUMMARY K

4/14
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

CARPENTRY

N.B The Contractor is refered also to separate


specifications prepared be the Engineers
for full descriptions and details

STRUCTURAL TIMBER

Structural sofwood pressure impregnated


with preservative as described

A 75 x 150mm purlins 91 m

B 50 x 150mm ceiling joists fixed to block walls 27 m

C 50mm x 100mm wall plate 43 m

D 50mm x 50mm brandering fixed to ceiling joists


at 600mm centres both ways as described 256 m2

Sundries

E 10 Gauge SWG galvanised wire to length and


nailed or tied to truss and wall plate and
built into wall as described 3 kg

JOINERY

All sizes quoted in this section are finished


sizes

LININGS

Particle Board Fixed to timber battens


(measured separately) including 10 x 38mm
wrot softwood cover strips and junction fixed
as described and set horizontally

4/15
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

F 8mm thick ceiling lining 67 m2

Wrought softwood as described

G 50 x 50mm coved cornice 104 m

H 25 x 225mm barge and fascia board 42 m

J Cover strip 112 m

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

JOINERY CONT'D

DOOR ETC

Exterior quality plywood faced solid core


flush doors as described

A 44mm door size 825 x 1960mm 2 No

Interior quality plywood faced hollow core


flush doors as described

B 44mm door size 825 x 1960mm 5 No

C Ditto size 725 x 1960mm 3 No

Trap Doors

D Ceiling hatch consisting of particle board


facing to fixed and including 30 x 100mm
softwood frame all round overall size 490 x
490mm placed in position 1 No

E Hatch shutter door 19mm thick laminated


particle board size 550 x 550mm with piano
hinges 2No chronium plated knobs including
30 x 100mm softwood frame 1 No

Shelving

Interior quality blockboard as described

F 18mm block boards shelving fixed to softwood bearers 7 m2

G 40 x 40mm softwood bearers pluged and screwed to 28 m


wall

4/16
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

Wrought softwood as described

H 25 x 50mm batten at 37.5mm in slatted shelving 15 m

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

IROMONGERY

Preamble

Rates for lcoks are to include for providing


each lock with a pair of keys. Each key shall
have an approved plastic or metal label with
the name of the room or other necessary
identification indelibly marked thereon and
attached to the key with a split steel ring

Supply and fix the following complete with metal


screws finished to match the article described

A Two lever mortice lock with anodised


aluminium lever furniture all as legge 3260/397/86
fixed to hollow core flush doors 8 No

B Three lever mortice lock with anodised


aluminium lever furniture all as legge 3260/397/86
fixed to hollow core flush doors 2 No

Supply and fix in position the following articles

C 1100mm long 25mm diameter chromium plated


pipe curtain rail fitted complete with rings and
end brackets complete as described 1 No

D 20mm diameter chromium plated tube as


towel rail 650mm long with 2No ball end
brackets plugged and screwed to wall 1 No

E White glazed vitrous China Toilet roll holders fixed to


walls 1 No

4/17
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

F White glazed vitrous China recessed soap tray


fixed to walls 1 No

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

IROMONGERY CON'TD

Supply and fix in position the following articles


Con'td

A 38mm diameter rubber door stop plugged or screwed


to concrete or wall 10 No

B 1300mm x 2000mm plastic shower curtain


with sewn seams and fixed to rings provided
to rail as described 1 No

To Collection K

COLLECTION

Page No 4/8 K

Page No 4/9 K

Page No 4/10 K

Page No 4/11 K

CARPENTRY, JONERY & IROMONERY


TOTAL CARRIED TO SUMMARY K

4/18
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

METAL WORK

Standard Units

Door Frames

ZAM 100 double rebate pressed steel door frames as


manufactured by Monarch Limited or other equal and
approved including a pair of butt hinge welded on
adjustable striker plate and rubber buffers primed with
one coat of red lead before delivery, building in lugs
to blockwork.

A Type 1.5M nominal size 900 x 2000mm 7 No

B Type 1.5M nominal size 800 x 2000mm 2 No

C Type 1.5M nominal size 900 x 2400mm with 400mm


fanlight 1 No

Window frames

All window shall have opening and fixed sections


fitted with standard pattern burglar bars
welded to window frames including aluminium
flyscreens as described

Supply and fix cottage section window section


as Monarch Limited or other similar approved
primed before delivery including all necessary

4/19
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

couplings, assembling, cutting and pinning or


plugging and screwing, building into wall and
pointed all round and servicing on completion

D Type W1 overall size 1800 x 1100mm 2 No

E Type W2 overall size 1200 x 1100mm 3 No

F Type W3 overall size 1200 x 900mm 1 No

G Type W4 overall size 900 x 500mm 1 No

H Type W5 overall size 600 x 500mm 1 No

J Type W6 overall size 600 x 1100mm 2 No

METAL WORK - TOTAL


CARRIED TO SUMMARY K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

PLUMBING INSTALLATION

SANITARY INSTALLATION

Galvanised mild steel pipe (medium) grade


and fittings and jointing and fixing as described

A 32mm waste pipe fixed to wall 2 m

B 38mm ditto 3 m

Extra over galvanised mild steel pipes for


fittings

C 32mm brass bend with inspection eye 1 No

D 38mm ditto 1 No

E 38mm bend 1 No

F 32mm splay cut end 1 No

G 38mm ditto 2 No

Copper fittings as described

H 32mm "P" trap with 63mm seal and jointing


with red lead to waste outlet and pipe 1 No

4/20
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

J 38mm ditto 2 No

K 38mm "P" trap as described set in concrete


with screwed joint to waste pipe and chromium
plated grating as shower outlet 1 No

Asbestos cement pipe and fittings, jointing and fixing


as described

L 100mm soil and vent pipe fixed to blockwall


with holder bats cut and pinned as described 10 m

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

SANITARY INSTALLATION CON'TD

Extra over AC pipes for the following fittings

A 100mm diameter bend with bolted inspection cover 1 No

B 100mm diameter pipe sweepy junction 1 No

C 100mm diameter for W.C pan connector 1 No

D 100mm diameter for gully trap 2 No

E 100mm diameter vent valve 1 No

SANITARY FITTINGS

NOTE Where taps are attached to fittings they


have been included in the description of the fitting

Supply and fix the following sanitary fitting


including assembling, forming all joints and
connections in accordance with the
manufacturers instructions, building in, cutting,
pinning or plugging and screwing to walls and/ or
floors and making good as described

4/21
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

F White glazed earthenware lavatory basin as


shanks 8027 complete with combined overflow,
32mm chromium plated waste outlet, plug, chain
and a pair of chromium plated pillar taps
marked "HOT" and "COLD" fixed on and
including manufacturers brackets plugged
and screwed 1 No

G Low level W.C suite as Armitage Favoria or equal and


approved "The Classic" comprising white glazed
earthen ware pan to BS 1213 with 'S' trap, flushing
cistern, flush pipe and block plastic hinged
seat fixed to floor and wall 1 No

H 13mm shower unit comprising pair chromium plated


valves marked "HOT" and "COLD" 13mm chromium
plated connection pipe 200mm long with 13mm tee to
13mm chromium plated riser 1000mm long with bend
at top and chromium plated shower rose fixed to wall
with brackets 1 No

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

SANITARY INSTALLATION CON'TD

A Stainless steel single bowl complete with 1 No.


chromium plated bib tap, 38mm waste, plug and chain 1 No

B Asbestos cement wash tub and draining board all as


TAP LimitedCatalogue No.589640 including standard
brackets cut and pinned to wall, 38mm chromium
plated waste outlet, plug and chain. 1 No

COLD AND HOT WATER INSTALLATION

Galvanised mild steel pipe (medium) grade


and fitting and jointing and fixing as described

C 13mm supply pipe fixed to wall 6 m

D 19mm ditto 15 m

E 19mm shower mixer 1 No

F 13mm sink mixer 1 No

Extra over galvanised mild steel pipes for the

4/22
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

following fittings.

G 19 x 13mm reducer 4

Copper pipes and fittings jointed and fixed as descrbed

H 13mm connector 450mm girth bent as


required with one end connected to galvanised
mild steel pipe and other end connected to tap 1 No

Electrical Water Heaters

J 90 litre Electrical Water Heater all as Monarch


Type "RE" or equal and approved with 13mm inlet
19mm service outlet and 19mm overflow all with
joints to galvanised mild steel pipe 1 No

Supply and fix the following valves obtained


from an approved manufacturer including
jointing to pipes as described

K 13mm brass chromium plated back flange bib tap


plugged and screwed to wall with joint to
galvanised mild steel pipe 2 No.

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

SANITARY INSTALLATION CON'TD

A 13mm screw down stop valve with joints to


galvanised mild steel pipes 5 No.

B 19mm ditto 2 No

C 19mm brass non-return valve with ditto 1 No

CHLORINATION AND TESTING

D Allow for super chlorination of all new pipe work


etc as described Item

E Allow for testing of all new pipe work etc as


described Item

BUILDING WORK IN CONNECTION WITH


PLUMBING INSTALLATION

Concrete Work

4/23
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

Brickwork and Blockwork

F Hole for small pipe through 150mm block


wall and make good 7 No

G Hole for large pipe through 150mm blockwall


and make good 3 No

Collection K

COLLECTION

Page No 4/13 K

Page No 4/14 K

Page No 4/15 K

Page No 4/16 K

PLUMBING INSTALLATION - TOTAL


CARRIED TO CARRIED K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELECTRICAL INSTALLATION

Preamble

Source

The source shall be 230 volt 50 Hertz single


phase and Neutral. Entry to the individual
houses shall be by means of conduit running in
the wall and roof void from the end use in each block.
The supply up to the Distribution Board is
measured elsewhere

Regulations and Tests

Regulations and tests shall be as set out in the


Standard specification

Type of Installation

4/24
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

The installation shall be of the flush mounted


PVC conduit type. Conduit may be run in the
floor screed if required

Method of Measurement Notes

The Contractor is deemed to have included


in his rates for cutting and forming holes and
chases, making good all work except, where
such items are specifically measured below
under "BUILDERS WORK IN CONNECTION
WITH ELECTRICAL INSTALLATION"

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELECTRICAL INSTALLATION CON'TD

The Contractor is deemed to have included in


his rate for:-

(i) Constant supervision by a supervisor


supervisor posssessing approved
qualification

(ii) Protection of the installation until handed


over and for taking requisite precautions
to protect workmen and the public for
electric shock or burn

The Contractor is deemed to have included for


cost of distribution boards and sub-distribution
boards in the rates inserted against the items

4/25
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

for supply points. Such distribution boards


shall be complete with burglar bars, earth and
neutral connecting blocks of adequate size,
isolators and miniature circuit breakers the
whole mounted 1.50 metres above finished floor
level. The Contractor should note that the
incoming supply upto the Distribution Board
is measured elsewhere

DISTRIBUTION BOARD

Distribution Board (MCB), labelled 10 way TP & N free


standing, comprising:-

A 60A MCB TP & N (incomin)


1Nr 30A SP MCB
1Nr 20A SP MCB
2Nr 15A SP MCB
2Nr 5A SP MCB
4Nr spares
Earth bar
Neutral bar
Surge arrestor
Inspection box 1 No

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELECTRICAL INSTALLATION CON'TD

LIGHTING POWER AND HEATING


INSTALLATION

Supply, install and connect all Conduit, conduit


fittings, cable, cable connections from the distribution
board to supply points connected together with all
switches etc. (lighting fittings
measured separately) for the following ceiling
mounted lighting points:-

A Lighting point controlled by one gang one way switch 7 No

B Lighting point controlled by two gang one way switch 3 No

4/26
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

Supply, install and connect the following lighting


fittings in accordance with the manufacturer's
instructions; philips range or other equal and approved

C 200mm (8") Opal spherical light fitting 2 No

D 100 Watts pendant light fitting, ceiling mounted with


ceramic lamp holder 7 No

E Weather proof bulkhead light fitting complete with all


accessories 4 No

MK or equal and approved light switches

F 6 Amp one gang one way switch 7 No

G 6 Amp two gang one way switch 3 No

Power Points

Supply, install and set to work the following power


points including all conduits, conduit fittings, cable
and cable connections to connect the power points to
the distributionboard, litemaster range or equal and
approved.

13 Amp double socket outlet, MK Range 7 No

20 Amp double pole switched and fused


water heater outlet 1 No

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

ELECTRICAL INSTALLATION CON'TD

A 45 Amp cooker control unit all as MK catalogue


No.5011 WHI with 13 Amp switched socke outlet
and hand fused plug top 1 No

B Supply and install a meter box complete with all


accessories 1 No

EARTHING INSTALLATION

C Provide for earth bonding to all isolated


pipework, waste pipes etc Item

4/27
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

TESTING

D Provide for testing the completed installation


to the satisfaction of the D.B as described Item

To Collection K

COLLECTION

Page No 4/17 K

Page No 4/18 K

Page No 4/19 K

Page No 3/20 K

ELECTRICAL INSTALLATION -
TOTAL CARRIED TO SUMMARY K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

FLOOR, WALL AND CEILING FINISHINGS

SCREED

Cement and sand (1:3) screed, finished with a


steel trowel and laid in one layer as described

A 40mm thick screed laid level on concrete 101 m2

B 30mm thick screed laid level on concrete to receive


non-slip ceramic floor tiles 6 m2

4/28
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

C 25mm skirting 75mm high on blockwork with


core at bottom and vee joint to plaster at top 90 m

D 100 x 100mm kerb trowelled smooth on top


and both sides to shower up stand 1 m

E V-joint on the floor as described 54 m

Walls

18mm cement and sand (1:4) plaster in one


coat with steel trowel finish on the following

F Concrete block walls externally 126 m2

G Concrete block walls internally 220 m2

H Plaster to reveal or return not exceeding 100mm


wide to reveals 94 m

J V-joint on the wall as described 68 m -

Floor Tiles

Non-slip ceramic floor tiles fixed with approved


adhesive to cement and sand screed (measured
separately) and pointed in white cement.

K 300 x 300 x 10mm thick ceramic tiles 6 m2

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

FLOOR, WALL AND CEILING FINISHINGS CONT'D

Wall tiles

Ceramic wall tiles fixed with approved adhesive to


plastered walls and pointed with white cement
as described

A 250mm x 200mm x 6mm thick wall tiles 54 m2

4/29
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

To Collection K

COLLECTION

Page No 4/21 K

Page No 4/22 K

FINISHINGS - TOTAL
CARRIED TO SUMMARY K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

GLAZING

Glazing to metal with putty as described

A 4mm clear sheet glass in panes exceeding 0.10m2


but not exceeding 0.5m2 12 m2

B 4mm obscure sheet glass in panes exceeding 0.1m2

4/30
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

but not exceeding 0.5m2 1 m2

C 6mm clear glass fixed in fan light size 800 x 400mm 1 No

BS 152 clear float, SG silvered and protected with


copper backing, undercoat paint and stoved enamel

D 6mm polished plate glass mirror as described


500 x 500mm plugged and screwed to wall
with 4No. Chromium plated detachable dome
headed screw 1 No

GLAZING - TOTAL
CARRIED TO SUMMARY K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

PAINTING AND DECORATING

Painting - Externally

Prepare and apply one undercoat and three coats of


clear PVA as described

4/31
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

A Plastered walls 126 m2

B To reveals and returns not exceeding 100mm wide 94 m

Painting - Internally

Prepare and apply three coats of clear PVA as


described

C Plastered walls 200 m2

D Soffit of particle board ceiling 101 m2

E Soffits of suspended slab 8 m2

F To reveals and returns not exceeding 100mm wide 94 m

Prepare and apply one undercoat three coats of oil


gloss as described

G Plastered walls 20 m2

Touch up primer and apply one under coat


two coats gloss oil paint as described on

H Steel windows and barglar bars (bothsides measured


overall, no deduction made for glass) 12 m2

J Pressed steel frames not exceeding 300mm girth 16 m2

Knot, prime stop and apply one under coat and


two coats gloss oil paint as described on

K General surfaces of flush doors and shelving 12 m2

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

PAINTING AND DECORATING CONT'D

Prepare and apply one under coat and two


coats of gloss oil paint as described on

4/32
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

A Small galvanised steel pipes 16 m

To Collection K

COLLECTION

Page No 4/24 K

Page No 4/25 K

PAINTING AND DECORATING -


TOTAL CARRIED TO SUMMARY K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

DRAINAGE (ALL PROVISIONAL)

Spoon Drain

4/33
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

A Spoon drain size 750mm x 250mm deep in concrete


bricks with sides dished to falls and including 150mm
laterite bed with sand blinding and pointing in
1:3 C/S mortar, all necessary excavations, fillings
and disposal
50 m
Asbestos cement gulleys as described jointed
together in cement and sand setting on
surrounding with concrete (grade C20) as
described, disposal of surplus excavated material
where directed on site and cement joint to
asbestos cement drain pipe

B 100 x 100 A/C gully trap complete with gully grating


complete with 100mm A/C gully P trap and joining
to drain and including setting in and surrounding
with plain in-situ concrete grade 15 as described
and carrying concrete to form kerbing and including
all necessary excavations part back filling disposal
of excavated materials and form work 4 No

Aprons and pavings

C Apron in 600 x 600 x 50mm precast concrete


joints laid to fall 90 m

Sawn Formwork

D Sides of apron slab not exceeding 100mm high 90 m

E 1550 X 1200 X 100mm thick concrete slab complete


with all necessary formwork 2 m3

EXTERNAL DRAINAGE - TOTAL


CARRIED TO SUMMARY
K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

SUMMARY PAGE

4/34
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

SUBSTRUCTURE 4/4 K

CONCRETE WORK 4/5 K

BRICKWORK AND BLOCKWORK 4/6 K

ROOFING 4/7 K

CARPENTRY, JOINERY & IRONMONGREY 4/11 K

METAL WORK 4/12 K

PLUMBING INSTALLATION 4/16 K

ELECTRICAL INSTALLATION 4/20 K

FINISHINGS 4/22 K

GLAZING 4/23 K

PAINTING AND DECORATIONS 4/25 K

EXTERNAL DRAINAGE 4/26 K

CONSTRUCTION OF 2NO. 3BEDROOM HOUSE


TOTAL CARRIED TO GENERAL SUMMARY K

EXCLUSIVE OF EXTERNAL DRAINAGE

4/35
CONSTRUCTION OF 1NO. 3BEDROOM HOUSES COMPLETE WITH SEWER RETICULATIONS SYSTEM

4/36
EXTERNAL WORKS

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

SITE CLEARANCE (ALL PROVISIONAL)

A Clear site of all grass, roots, rubbish, dead


vegetation, weeds and scrubs, saplings and
trees not exceeding 600mm girth (measured
1000mm above ground level) all tree stumps
not exceeding 600mm girth (measured at
ground level), fill in all holes, remove or
burn arisings and roughly level site (measured
over all existing building, etc)) 3,949 m2

B Cut down trees exceeding 600mm but not


exceeding 900mm girth (measured 1M from ground
level),and burn or entirely grub up roots, log up
and burn or entirely remove from site and fill in
hole with clean selected material from the
excavations, well rammed and level surface
of filling ready for excavations 20 No

SITE CLEARANCE - TOTAL


CARRIED TO SUMMARY K

5/37
EXTERNAL WORKS

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

EXTERNAL WATER RETICULATION


Excavations as described (All Provisional)

A Sluice valve chamber size 400mm x 400mm x


800mm deep 150mm thick solid concrete
brickwork sides and building pipes 2 Nr

B Excavate for pipe trench not exceeding1500mm


1.5mm deep and average 600mm deep for
water service pipe not exceeding 100mm
diameter and get out including all necessary
planking and strutting, backfilling with
selected excavated material and disposal
of surplus excavated materials (Provisional) 590 m

Medium duty galvanised steel pipes fittings


and fixing as described

C 19mm diameter pipe laid in trenches (provisional) 190 m

D 25mm diameter pipe laid in trenches (provisional) 300 m

E 50mm diameter pipe laid in trenches (provisional) 100 m

Extra over the foregoing pipes for the


following fittings

F 50mm Bend 2 No

G 25 x 25 x 19mm Tee 12 No

H 50 x 50 x 25mm Tee 4 No

J 25 x 19mm reducer 16 No

K 25mm end plug 4 No

L 50mm diameter sluice valve to BS 1218 class 1


complete with cap joint to steel pipe 2 No

EXTERNAL WATER RETICULATION


TOTAL CARRIED TO SUMMARY K

5/38
EXTERNAL WORKS

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

SOIL DRAINAGE (ALL PROVISIONAL)

EXCAVATIONS FOR PIPING

A Excavating trenches starting from existing ground level to


receive pipes not exceeding 200mm nominal size, grading
bottoms, earthwork supports, backfilling with excavated
material, disposing of surplus excavated material by removing
from site; not exceeding 1.50 metres deep, average 750mm deep 200 m

B Extra over excavating in hard rock (Provisional) 6 m³

C 75mm thick compacted bed of selected gravel to 100mm


diameter drain pipes in trenches including additional excavations 200 m

D Plain in situ concrete (1:2:4 - 20mm aggregate)


in 150mm bed and surround to 100mm drain pipe
in trenches including additional excavation and
any necessary formwork 200 m

ASBESTOS - CEMENT DRAIN PIPES AND FITTINGS


AND LAYING AND JOINTING AS DESCRIBED

E 100mm diameter asbestos cement drain pipe


including laying and jointing in trenches 89 m

150mm diameter asbestos cement drain pipe


including laying and jointing in trenches 39 m

F Extra over 100mm asbestos cement drain pipes for Bend 6 Nr

THE FOLLOWING IN 6 NR. MANHOLES

G Excavating in pits size 900x900mm and depth n.e 1.5m


from reduced level 6 m3

H Leveling and compacting bottoms of excavations 9 m2

J Remove excavated materials and store for reuse 6 m3

Plain insitu concrete 1:3:6 grade 20 aggregates in the following

K Beds laid on earth 100mm thick to bottoms of manhole 9 m2

L Benching in bottoms rendered with 13mm c/s mortar before


final set, 800x800mm average 200mm thick 32 Nr

5/39
EXTERNAL WORKS

Caried to Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

6 NR. MANHOLES CONT'D

Reinforced insitu concrete BS 5828, prescribed


C25, 20mm aggregate

A 100mm thick suspended slab 6 m2

Reinforcement

B 12mm diameter bar to suspended slab 125 kg

Form work generally

C To soffits of slab 12 m2

D Edges of slabs, vertical face not exceeding 100mm 39 m

E Hole associated with slabs, rectangular, straight sides


2.4m girth in edges n.e 100mm thick 6 nr

Sundries in all concrete

F Treating surfaces of un set concrete by tamping and leveling 12 m2

BLOCKWORK

Solid concrete block work filled solid with lean concrete

G 150mm thick block work in 1:3 c/s mortar 36 m2

Sundries

H Building in ends of pipes, large, through 200mm block


work and making good finishings disturbed 27 No

Mortar, cement and sand 1:3 steel troweled to block work

J 15mm thick plaster to walls 72 m2

K 25mm(average) thick cement and sand haunching to top of


concrete cover slabs, wethered five ways and
trowelled with wood float 12 m2

Standard Units

5/40
EXTERNAL WORKS

L Access cover BS 497 coated, heavy duty, bedding frame in


cement and sand mortar, size 600x450mm cast iron 6 nr

Carried to collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

TYPE V SEPTIC TANK TYPE FIVE

Excavations and Earthworks

A Excavate pit for Septic Tank starting at


ground level not exceeding 1.5m deep and
remove excavated material from site 29 m3

B Ditto exceeding 1.5 but not exceeding 3.0m


deep 28 m3

C Extra over for excavating in hard rock 3 m3

D Part return fill and ram excavated materials 6 m3

E Cart away surplus excavated materials from site n.e 50m


and spread over 50 m3

F Compact bottoms of excavated pits to receive concrete 28 m2

Concrete works

G 50mm thick concrete (1:4:8 - 40mm aggregate) base slab


blinding 28 m2

H Plain reinforced concrete (1:2:4 - 20mm aggregate)


in 150mm surface bed 28 m2

J 100mm thick suspended reinforced slab 28 m2

Reinforcement

K One layer of conforce '86' or other equal and


approved fabric reinforcement in concrete bed
with minimum laps of 150mm (no allowance
made for laps) 28 m2

L 12mm diameter yield steel reinforcement in


cover slab 208 kg

Formwork

5/41
EXTERNAL WORKS

M Sawn formwork to soffits of cover slab 22 m2

N Ditto to edges of cover slab exceeding 100mm


not exceeding 200mm high 35 m

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

Septic tank contd

A Boxing out rebated hole size 450x600mm including all


formwork 4 Nr

Block work

B 200mm concrete block walls in cement and sand


1:4 mortar filled solid with concrete
(1:4:8-20mm aggregate) 60 m2

C 200mm brickforce reinforcement to walls every three courses 264 m

Plastering

D 12mm cement and sand 1: 3 water proof plaster to walls


internally finished smoothwith a steel trowel 90 m2

Standard units

E 600 x 450mm cast iron manhole cover and


frame fixed in position in cover slab 4 nr

G 100mm asbestos cement in-flow and out-flow


tees, partly embedded in block walls 4 nr

Sundries and labours

H Hole through 200mm block wall for large


pipe and make good 4 nr

J Planking and strutting to sides of excavations Item

K Allow for keeping excavations free from general


water by pumping bailing or other suitable
means and for clearing away debris off site Item

SOAKAWAY

L Excavated pit for soakaway starting at ground level not


exceeding 1.5m deep and remove excavated material from site 24 m3

5/42
EXTERNAL WORKS

M Ditto exceeding 1.5m but not exceeding 3.0m deep ditto 22 m3

N Extra over for excavated in hard rock 6 m3

Carried to collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

Soakaway Cont'd

A Cart away surplus excavated materials from site n.e 50m


and spread over 44 m3

B Selected imported rubble backfill in trench


excavates (I.e small stones) 8 m3

C Selected imported rubble backfill in soak away pits


(i.e large stones) 32 m3

D Planking and strutting to sides of excavations Item

E Allow for keeping excavations free from


general water by pumping bailing or other
suitable means and for clering away debris
off site Item

Concrete works

F 1:2:4 concrete in foundations 2 m3

G 100mm thick concrete in suspended slab (1:2:4 - 20mm


aggregate) 16 m2

Reinforcement

H 12mm diameter yield steel reinforcement in cover slab 76 kg

Formwork

J Sawn formwork to soffits of cover slab 16 m2

K Ditto to edges of cover slab exceeding 100mm


not exceeding 200mm high 14 m

L Boxing out rebated hole size 450x600mm including all


formwork 2 Nr

5/43
EXTERNAL WORKS

Block work

M 200mm thick blockwork in walls in 1:4c/s mortar 18 m2

N Ditto in honey comb 44 m2

P Form 150mm hole through 200mm blockwork 2 Nr

Carried to collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

Soakaway Cont'd

Standard units

A 600 x 450mm cast iron manhole cover and


frame fixed in position in cover slab 2 nr

Sundries

B Testing whole of the drainage system as work proceeds


and completion water pressure method Item

Carried to collection K

COLLECTION

Page 5/5 K

Page 5/6 K

page 5/7 K

page 5/8 K

page 5/9 K

page 5/10 K

SOIL DRAINGE - TOTAL CARRIED TO SUMMARY K

5/44
EXTERNAL WORKS

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

OVER HEAD TANK

A Excavate in picable material trench not exceeding


400 deep x 300mm wide for pipework (Provisional) 60 m

B Excavate trenches for electrical cables 500mm deep


x 300mm wide (Provisional) 60 m

C Extra over excavating in hard rock (Provisional) 1 m3

D Supply and install 10,000 litres elevated polycon


tanks complete with all accessories 1 No

E Supply and install 5 Horse Power booster pumps


with control panels and automation 1 No

F Supply and fix 75mm diameter galvanised iron pipes


from tank stand to ground 14 m

G Supply and fix 50mm diameter galvanised iron pipes


from borehole to elevated tank and houses (provisional) 80 m

H Supply and fix 75mm diameter non-return valves 2 No

J Supply and fix 50mm diameter non-return valves 2 No

K Supply and fix 50mm diameter tees 2 No

L Supply and fix 75mm diameter bends 4 No

M Supply and install 50mm diameter bends 4 No

N Supply and fix 75mm diameter gate valves 2 No

P Supply and fix 50mm diameter gate valves 2 No

5/45
EXTERNAL WORKS

To Collection K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

OVER HEAD TANK CON'TD

A Provide and install automated control panel complete


with protection gadgets against over and underload,
phase failure, dry pumping detector units and
lighting arrestors 1 No

B Supply and fix automatic overflow with floater as


approved by Engineer 1 No

C Supply and erect 12.0m high structural steel tank


as per Engineer's drawing 1 No

D Allow for building of security manhole size 800 x


800 internally x 900mm deep overall consiting of
100mm thick plaint in-situ concrete (1:3:6) base,
150mm thick solid concrete blockwork sides
rendered internally, 100mm reinforced in-situ
(1:2:4) cover slab with opening to suit 460 x 610mm
lockable cover bedded in cement and sand mortar
(1:3) building in large pipes to 150mm thick wall
and necessary excavations disposal of surplus
excavated materials from site 2 No

E Allow for two coats aluminium paint to all exposed


pipeworks Item

To Collection K

COLLECTION

Page No 5/9 K

5/46
EXTERNAL WORKS

Page No 5/10 K

OVER HEAD TANK - TOTAL


CARRIED TO SUMMARY K

ITEM DESCRIPTION QTY UNIT RATE AMOUNT

SUMMARY
PAGE

SITE CLEARING 5/1 K

EXTERNAL WATER RETICULATION 5/2 K

ELEVATED WATER TANK 5/4 K

SOIL DRAINAGE 5/8 K

ELEVATED WATER TANK 5/10 K

EXTERNAL WORKS - TOTAL CARRIED TO


GENERAL SUMMARY K

5/47
EXTERNAL WORKS

5/48

You might also like