S800 I/O Module Compatibility Guide
S800 I/O Module Compatibility Guide
NOTE A: The table below reflects the up to date situation for the latest releases of controllers and S800 I/O, 2006-10-30
NOTE B: Variants for ISA-S71.043 level G3 are also available on Items marked like this. No change in configuration is needed.
NOTE C: S800 I/O can be connected to any PROFIBUS master. The functionality must then be checked.
NOTE D: SIL rated modules or modules only used in safety applications are not listed below
x Supported module
1 HART pass-through ONLY when using 3rd party software 'Cornerstone '. Read separate Advant Master documentation.
2 HART pass-through is NOT available
4 Communication with redundant controllers has NOT been tested
5 NOT supported with CI830.
6 HART communication requires Device Integration Package for PROFIBUS/HART.
7 HART communication requires Fieldbus Builder PROFIBUS/HART v2.1 and S800 I/O DTM v1.0
8 Data has to be manually mapped using the DCI controller software object PMAP module
9 HART pass-through via S800 HART Templates. See Hot Fix with CBF7.1 SP2a or later.
10 The SOE functionality of the module is NOT available
11 AO810 replaced by AO810V2, AI830 replaced by AI830A
Symphony DCI
AC 110
AC 160
AC 70
Part no Item description
3BSE022366R1 CI801 Single Profibus Communication Interface for single I/O x x x x x x
3BSE038540R1000 CI801 Engineering kit x x x x x
3BSE020520R1 CI810B AF100 Field Comm. Interface 1 x x x
3BSE025255R1 CI820V1 S800 Redundant FCI 1 x x
3BSE013252R1 CI830 Single Profibus Communication Interface for single I/O 2 2 2 2 2 2 2
3BSE031695R1400 CI830 Engineering kit x x x
3BSE022457R1 CI840 Redundant Profibus Communications Interface. x x x x x x x
3BSE031694R3000 CI840 Engineering Kit x x x x x
3BSE013204R1 TB815 Interconnection Unit x x x
3BSE022460R1 TU846 Module Termination Unit, MTU, for CI840 and redundant I/O x x x x x x x
3BSE022462R1 TU847 Module Termination Unit for CI840 and single I/O x x x x x x x
3BSC970089R1 Extra, Front label set FCI/AC 70 x x x x x x x x x x x x x
3BSC970091R1 Extra, Label set, item design. FCI/AC 70 x x x x x x x x x x x x x
3BSE040749R1 Mounting kit for vertical mounting on vertical DIN rail x x x x x x x x x x x x x x x
3BSC950004R1 TK527V030 Interface cable, L = 3 m. DE9 x x x x x x x x x x x x x
3BSC630167R2 TK212 Tool cable, needed also for CI801 x x x x x x x x
3BSE038407R1 FS801K01 Service adapter kit for CI801 x x x x x x
3BSC550038R3 TC501V150 Termination unit, 150 Ohm x x x x x
3BSC840074R1 TC506 AF100 Trunk Tap x x x x x
3BSE018405R1 TC513V1 AF100 Twisted pair Coax Modem x x x x x
3BSE013281R1 TC514V2 AF100 Twisted pair to opto repea x x x x x
3BSE013284R1 TC515V2 AF100 Twisted pair to twisted pa x x x x x
3BSE006251R1 AF100K03 Connection Kit, single. x x x x x
3BSE008516R1 AI810 Analog input 1*8 ch. x x x x x x x x x x x x x x x
3BSE008544R1 AI820 Analog input 4*1 ch. x x x x x x x x x x x x x x x
3BSE036456R1 AI825 Analog input 4 galvanic isolated ch. x x x x x x x
3BSE040662R1 AI830A Analog Input 1x8ch (11) x x x x x x x x x x x x x x x
3BSE008520R1 AI835 Analog input 8 ch. Thermocouple/mV x x x x x x x x x x x x x x x
3BSE028925R1 AI843 Thermo coupler Input. Redundant or single x 5 x x x x x
3BSE023675R1 AI845 Analog Input. Redundant or single 6 5.6 7 x 2 x 2 2
3BSC690071R1 AI890 Analog Input 1x8 ch with Intrinsic x x x x x x x x x x x x x
3BSC690141R1 AI893 Thermo coupler iutput with Intrinsic interf x x x x x x 8
3BSC690086R1 AI895 Analog Input 1x8 ch with Intrinsic 6 5.6 7 7 1 x 2 x 9 2 x
3BSE038415R1 AO810V2 Analog output 1*8 ch (11) x x x x x x x x x x x x x x x
3BSE008546R1 AO820 Analog Output 4*1 ch, x x x x x x x x x x x x x x x
3BSE023676R1 AO845 Analog Output. Redundant or single 6 5.6 7 x 2 x 2 2
3BSC690072R1 AO890 Analog Output 1x8 ch with Intrinsi x x x x x x x x x x x x
3BSC690087R1 AO895 Analog Output 1x8 ch with Intrinsi 6 5.6 7 7 1 x 2 x 9 2 x
3BSE008508R1 DI810 Digital Input 24V d.c. 2x8 ch. x x x x x x x x x x x x x x x
3BSE008552R1 DI811 2x8 ch 48V Digital input x x x x x x x x x x x x x x
3BUR001454R1 DI814 Digital Input 24V d.c. Current Sou x x x x x x x x x x x x x x x
3BSE008512R1 DI820 Digital Input, 120 V a.c. x x x x x x x x x x x x x x x
3BSE008550R1 DI821 Digital Input 230V a.c. x x x x x x x x x x x x x x x
3BSE036373R1 DI825 Digital Input 125V d.c. SOE x
3BSE013210R1 DI830 Digital Input 24V d.c. SOE x x x x x
3BSE013212R1 DI831 Digital Input 48V d.c.,SOE x x x x
3BSE020836R1 DI840 Digital Input. Redundant or single x 5,10 10 10 10 10 10 10
3BSE013088R1 DI885 Digital Input 24/48V d.c.,SOE x x x x x
3BSC690073R1 DI890 Digital Input 8x1 ch with Intrinsi x x x x x x x x x x x x
3BSE008510R1 DO810 Digital Output 24 V d.c. x x x x x x x x x x x x x x x
3BUR001455R1 DO814 Digital Output current sinking x x x x x x x x x x x x x x x
3BSE013258R1 DO815 Digital Output 24V d.c x x x x x x x x x x x x x x
3BSE008514R1 DO820 Digital Output, Relay. Normal open x x x x x x x x x x x x x x x
3BSE013250R1 DO821 Digital Output, Relay. Normal clos x x x x x x x x x x x x x x
3BSE020838R1 DO840 Digital Output. Redundant or singl x 5 x x x x x x x
3BSC690074R1 DO890 Digital Output 4x1 ch with Intrins x x x x x x x x x x x x
3BSE013228R1 DP820 Pulse Counter RS-422, Current, 5V x x x x x x x x x x 8 x
3BSE028926R1 DP840 Counter and Freq Input. Redundant or single. x x x x x x 8
3BSC970087R1 Extra, Front label set I/O-box 16 ch x x x x x x x x x x x x x x x
3BSE038280 Rev. I 1 of 3
07/07/2009 Support of S800 I/O modules and features in various controllers
NOTE A: The table below reflects the up to date situation for the latest releases of controllers and S800 I/O, 2006-10-30
NOTE B: Variants for ISA-S71.043 level G3 are also available on Items marked like this. No change in configuration is needed.
NOTE C: S800 I/O can be connected to any PROFIBUS master. The functionality must then be checked.
NOTE D: SIL rated modules or modules only used in safety applications are not listed below
x Supported module
1 HART pass-through ONLY when using 3rd party software 'Cornerstone '. Read separate Advant Master documentation.
2 HART pass-through is NOT available
4 Communication with redundant controllers has NOT been tested
5 NOT supported with CI830.
6 HART communication requires Device Integration Package for PROFIBUS/HART.
7 HART communication requires Fieldbus Builder PROFIBUS/HART v2.1 and S800 I/O DTM v1.0
8 Data has to be manually mapped using the DCI controller software object PMAP module
9 HART pass-through via S800 HART Templates. See Hot Fix with CBF7.1 SP2a or later.
10 The SOE functionality of the module is NOT available
11 AO810 replaced by AO810V2, AI830 replaced by AI830A
Symphony DCI
AC 110
AC 160
AC 70
Part no Item description
3BSC970088R1 Extra, Front label set I/O-box 8 ch x x x x x x x x x x x x x x x
3BSC970306R1 Extra, Front label set I/O-box 4 ch x x x x x x x x x x x x x x x
3BSE035990R1 TU805K01 10pcs TUs for 2-wire to DI801 and DO801 x x x x x x x x x x x x x x
3BSE013230R1 TU810V1 Compact Module Termination Unit, x x x x x x x x x x x x x x x
3BSE013231R1 TU811V1 Compact Module Termination Unit, x x x x x x x x x x x x x x x
3BSE013232R1 TU812V1 Compact Module Termination Unit, x x x x x x x x x x x x x x x
3BSE036714R1 TU813 Compact Module Termination Unit, x x x x x x x x x x x x x x x
3BSE013233R1 TU814V1 Compact Module Termination Unit, x x x x x x x x x x x x x x x
3BSE013234R1 TU830V1 Extended Module Termination Unit x x x x x x x x x x x x x x x
3BSE013235R1 TU831V1 Extended Module Termination Unit x x x x x x x x x x x x x x x
3BSE038726R1 TU833 Extended Module Termination Unit, spring-cage terminals x x x x x x x x x x x x x x x
3BSE013236R1 TU835V1 Extended Module Termination Unit x x x x x x x x x x x x x x x
3BSE013237R1 TU836V1 Extended Module Termination Unit x x x x x x x x x x x x x x x
3BSE013238R1 TU837V1 Extended Module Termination Unit x x x x x x x x x x x x x x x
3BSE008572R1 TU838 Extended Module Termination Unit, x x x x x x x x x x x x x x x
3BSE020850R1 TU842 Module Termination Unit, MTU, for x x x x x x x x x
3BSE021443R1 TU843 Module Termination Unit, MTU, for x x x x x x x x x
3BSE021445R1 TU844 Module Termination Unit, MTU, for x x x x x x x x x
3BSE021447R1 TU845 Module Termination Unit, MTU, for x x x x x x x x x
3BSC690075R1 TU890 Module Termination Unit for Intri x x x x x x x x x x x x x x
3BSC840157R1 TU891 Module Termination Unit for non x x x x x x x x x x x x x x
3BSE023607R1 TY801K01 8pcs Shunt Stick TY801 x x x x x x x x x
3BSE033670R1 TY804K01 8pcs Shunt Stick TY804 x x x x x x x
3BSE020512R1 AI801 Analog input 1*8 ch, x x x x x x x x x x x x x
3BSE020514R1 AO801 Analog output 1*8 ch, x x x x x x x x x x x x x
3BSE020508R1 DI801 Digital Input 24V d.c. x x x x x x x x x x x x x
3BSE022360R1 DI802 Digital Input 120V a.c./d.c., 8*1c x x x x x x 8
3BSE022362R1 DI803 Digital Input 230V a.c./d.c., 8x1c x x x x x x 8
3BSE020510R1 DO801 Digital Output 16ch. 24V d.c. 0.5A x x x x x x x x x x x x x
3BSE022364R1 DO802 Digital Output, Relay. Normal open x x x x x x 8
3BSE019419R1 Label Set S800L x x x x x x x x x x x x
3BSE019419R2 Label Set S800L x x x x x x x x x x x x
3BSE008534R1 TB805 Bus Outlet x x x x x x x x x x x x x x x
3BSE021437R1 TB845, Dual Modulebus outlet x x x x x x x x x x
3BSE008536R1 TB806 Bus Inlet x x x x x x x x x x x x x x x
3BSE021439R1 TB846, Dual Modulebus inlet x x x x x x x x x x
3BSC950089R1 TK801V003 Cable, x x x x x x x x x x x x x x x
3BSC950089R2 TK801V006 Cable, x x x x x x x x x x x x x x x
3BSC950089R3 TK801V012 Cable, x x x x x x x x x x x x x x x
3BSE008538R1 TB807 Modulebus terminator x x x x x x x x x x x x x x x
3BSE013208R1 TB820V2 Modulebus Cluster Modem x x x x x x x x x x x x x x x
3BSE021456R1 TB840 Modulebus Cluster Modem x x x
3BSE036634R1 TB825 Optical media converter x
3BSE008560R1 TB810 Modulebus Optical Port x x x x x x x x x x x x
3BSE008568R1 TB811 Modulebus Optical Port x x x x x x x x x
3BSE022464R1 TB842 Modulebus Optical Port x x x x x x x x
3BSE020846R1 TU840 Termination Unit for 1+1 TB840 Su x
3BSE020848R1 TU841 Termination unit for 1+1 TB840 Su x x x
3BSE042558R1 TU848 Termination Unit for 1+1 TB840 with individual supply x
3BSE042560R1 TU849 Termination unit for 1+1 TB840 with individual supply x x x
3BSC950107R1 TK811V015 POF Cable x x x x x x x x x x x x x x x
3BSC950107R2 TK811V050 POF Cable x x x x x x x x x x x x x x x
3BSC950107R3 TK811V150 POF Cable x x x x x x x x x x x x x x x
3BSC950118R1 TK812V015 POF Cable x x x x x x x x x x x x x x x
3BSC950118R2 TK812V050 POF Cable x x x x x x x x x x x x x x x
3BSC950118R3 TK812V150 POF Cable x x x x x x x x x x x x x x x
3BSC610037R1 SD821 Power Supply Device x x x x x x x x x x x x x x x
3BSC610038R1 SD822 Power Supply Device x x x x x x x x x x x x x x x
3BSC610039R1 SD823 Power Supply Device x x x x x x x x x x x x x x x
3BSE038280 Rev. I 2 of 3
07/07/2009 Support of S800 I/O modules and features in various controllers
NOTE A: The table below reflects the up to date situation for the latest releases of controllers and S800 I/O, 2006-10-30
NOTE B: Variants for ISA-S71.043 level G3 are also available on Items marked like this. No change in configuration is needed.
NOTE C: S800 I/O can be connected to any PROFIBUS master. The functionality must then be checked.
NOTE D: SIL rated modules or modules only used in safety applications are not listed below
x Supported module
1 HART pass-through ONLY when using 3rd party software 'Cornerstone '. Read separate Advant Master documentation.
2 HART pass-through is NOT available
4 Communication with redundant controllers has NOT been tested
5 NOT supported with CI830.
6 HART communication requires Device Integration Package for PROFIBUS/HART.
7 HART communication requires Fieldbus Builder PROFIBUS/HART v2.1 and S800 I/O DTM v1.0
8 Data has to be manually mapped using the DCI controller software object PMAP module
9 HART pass-through via S800 HART Templates. See Hot Fix with CBF7.1 SP2a or later.
10 The SOE functionality of the module is NOT available
11 AO810 replaced by AO810V2, AI830 replaced by AI830A
Symphony DCI
AC 110
AC 160
AC 70
Part no Item description
3BSC610042R1 SS822 Power Voting Unit x x x x x x x x x x x x x x x
3BSE020923Rxxxx S800 I/O - General Information and Installation x x x x x x x x x x x x x x x
3BSE020924Rxxxx S800 I/O - Modules and Termination Units x x x x x x x x x x x x x x x
3BSE020925Rxxxx S800 I/O - Fieldbus Communication Interf AF100 x x x x x
3BSE020926Rxxxx S800 I/O - Fieldbus Communication Interf PROFIBUS x x x x x x x x x x x
3BSE020927Rxxxx S800 I/O - Modules and Termination Units with IS interfaces x x x x x x x x x x x x x x x
3BSE000506Rxxxx Advant Fieldbus 100 User's Guide x x x x x
3BSE036959Rxxxx S800 I/O Profibus FCI - Memory maps for CI801 x x x x x x x x x
3BSE019081Rxxxx S800 I/O Profibus FCI - Memory maps for CI830 x x x x x x x x x x x
3BSE025251Rxxxx S800 I/O Profibus FCI - Memory maps for CI840 x x x x x x x x x
3BSE038280 Rev. I 3 of 3