Design of Bolted Direct Shear Connection To BS5950: Rumah Guru Water Tank Tower Diagonal Bracing
Design of Bolted Direct Shear Connection To BS5950: Rumah Guru Water Tank Tower Diagonal Bracing
Page 1
Project : Rumah Guru
Location : Water Tank Tower
Connection : Diagonal Bracing
tb1 tb2
tb3
Group B
ta1
ta2
Group A
B Loading
1) Ordinary Bolt
Bolt grade = 4.6 (gr 4.6 or 8.8)
Shear strength ps = 160 N/mm2
Bearing strength pbb = 435 N/mm2
Group A
Nos. of end bolts Nae = 0 nos
Nos. of internal bolts Nai = 0 nos
Diameter of bolt da = 16 mm
Area of shank Asa = 157 mm2
Area of thread Ata = 157 mm2
Shear action : 1 (1=Sgl 2=Dbl)
Shear capacity per bolt Psa = 25.1 KN
Bearing capacity of bolt Pba 0.0 KN
Group B
Nos. of bolts Nbe = 1 nos
Nos. of internal bolts Nbi 1 nos
Diameter of Bolt db = 16 mm
Area of shank Asb = 157 mm2
Area of thread Atb = 157 mm2
Shear action : 1 (1=Sgl 2=Dbl)
Shear capacity per bolt Psb = 25.1 KN
Bearing capacity of bolt Pbb = 41.8 KN
2) Connecting Members
Steel grade = 43 (gr 43, 50 or 55)
Bearing strength pbb = 460 N/mm2
Design strength py = 275 N/mm2
Group A
Plate thickness ta1 = 0.00 mm
ta2 = 0.00 mm
End distance e = 30 mm
Bearing capacity at end bolt Pbae = 0.0 KN
Bearing capacity at internal bolt Pbai = 0 KN
Group B
Plate thickness tb1 = 8.00 mm
tb2 = 6.00 mm
tb3 = 0.00 mm
End distance e = 30 mm
Bearing capacity at end bolt Pbbe 41.4 KN
Bearing capacity at internal bolt Pbbi = 44.2 KN
D Result