Sikadur - 52 LP (IN) : Low Viscosity Injection Resin

This document provides product data and application instructions for Sikadur-52 LP (IN), a low viscosity epoxy resin for injection into cracks. It has advantages like being solvent-free and suitable for both dry and damp conditions. The document describes the product's uses, characteristics, technical data, storage requirements, and application methods.

Uploaded by

Sunny Rohilla
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
152 views3 pages

Sikadur - 52 LP (IN) : Low Viscosity Injection Resin

This document provides product data and application instructions for Sikadur-52 LP (IN), a low viscosity epoxy resin for injection into cracks. It has advantages like being solvent-free and suitable for both dry and damp conditions. The document describes the product's uses, characteristics, technical data, storage requirements, and application methods.

Uploaded by

Sunny Rohilla
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Product Data Sheet

Edition 01/01/2015
Identification no:
02 07 07 03 001 0 000052
Sikadur®-52 LP (IN)

Sikadur®-52 LP (IN)
Low viscosity injection resin

Product ®
Sikadur -52 LP (IN) is two part, low viscosity, moisture insensitive injection-liquid,
Description based on high strength epoxy resin.
Construction

Uses As an injection resin with good adhesion to dry concrete, mortar, stone, steel and
®
wood. Sikadur -52 LP(IN) is used to fill and seal voids and cracks in structures
such as bridges and other civil engineering buildings, industrial and residential
buildings, e.g. columns, beams, foundations, walls, floors and water retaining
®
structures. Sikadur -52 LP(IN) is suitable for ASTM C 881, Type I, Grade-1, Class
E+F
Characteristics /  Solvent-free
Advantages  Suitable for both, dry and damp conditions
 Usable at low temperatures
 Shrinkage free hardening
 High mechanical and adhesive strengths
 Hard but not brittle
 Low viscosity
 Injectable with single component pumps

Product Data

Form
Colours Part A: Colourless
Part B: Pale Yellow
Part A+B mixed: Clear Pale yellow
Packaging 1 kg (A+B) Pre-batched unit.
Part A: 0.80 kg metal container
Part B: 0.2 kg metal container

Storage
Storage Conditions/ 12 months from date of production if stored properly in unopened, undamaged and
Shelf-Life sealed original packaging, in dry conditions at temperatures between +5°C and
+40°C.

Technical Data
Chemical Base Epoxy resin.
Mixed Density 1.1 kg/l (at +27°C)
Viscosity ~ 250 mPas at +30°C

1 Sikadur®-52 LP (IN) 1/3


Mechanical / Physical
Properties
Compressive Strength (According to ASTM D 695)
Curing time +30°C
7 days at +30°C ~ 65 N/mm2

(According to ASTM C 579)


Curing time +30°C
7 days at +30°C ~ 70 N/mm2

Flexural strength (According to ISO 178)


Curing time +30°C
7 days at +30°C ~ 50 N/mm2
2
Tensile Strength ~ 50 N/mm (after 7 days at +30°C cure) (According to ASTM D 638)
2
Tensile Modulus ~ 2000 N/mm (after 7 days at +30°C cure) (According to ASTM D 638)
Tensile Elongation (%) ~ 1.9 (According to ASTM D 638)
2
Bond Strength ~ 7.5 N/mm after 2 days at +30°C cure (According to ASTM C 882)
2
~ 10.8 N/mm (failure in concrete) after 14 days at +30°C cure
Water absorption (%) ~ 0.6 after 24 hours water immersion (According to ASTM D 570)
Shrinkage Passes (According to ASTM C 883)

System
Information

Application Details
®
Consumption / Yield 1.11 kg of Sikadur -52 LP (IN) is ~ equal to 1 l injection resin.
Substrate Preparation Requirements:
Sound, clean, free from oil and grease and surface treatments etc.
Pre-treatment for good bond:
Concrete, mortar, stone should be thoroughly prepared by high pressure water
jetting or mechanical means such as grinding, chiselling etc. Cracks must be
cleaned to remove dust with compressed air.

Application
Conditions /
Limitations
Substrate Temperature +10°C min. / +40°C max.
Substrate Moisture Dry condition
Content

Application
Instructions
Mixing Part A : Part B = 0.8 : 0.2 (by weight)
Mixing Time Pre-batched packaging:
Add all of part B to part A. Mix with an electric mixer at slow speed (max. 250 rpm)
for at least 3 minutes. Avoid entraining air.
Bulk packaging:
Add both parts in the correct proportion into a suitable clean, dry container and mix
in the same way as for the pre-batched units.
Application Method / Successful application depends on very careful preparation. The surface to be
Tools treated must be structurally sound, free from standing water, oil, grease, surface
contaminants. Dirt, dust and other foreign materials must be removed. Concrete

2 Sikadur®-52 LP (IN) 2/3


which is fully contaminated with oil / grease, must be removed to the depth of sound
& uncontaminated concrete.

Impregnation of cracks on horizontal slabs:


Impregnation is applied with a paint brush or roller until complete saturation of the
substrate is achieved. Cracks are sealed by pouring mixed Sikadur® 52 LP(IN)
directly from the mixing vessel between two “dams” made from Sikaflex® sealant.
Crack penetrating slabs to their soffit should first be sealed on the underside with
®
Sikadur -31 epoxy mortar or a suitable cementitious Sika mortar.

Injection of cracks on horizontal / vertical slabs:


Injection flange / nipples are fixed along the crack line at an approximately 25 cm
®
center-to-center distance with Sikadur -31. Crack mouth should be opened and
®
sealed with Sikadur -31. Crack penetrating slabs to their soffit should also be
®
sealed on the underside with Sikadur -31 epoxy mortar or a suitable cementitious
®
Sika mortar. Mixed Sikadur -52 LP (IN) can be injected under pressure through
injection ports using injection pump, such as Aliva AL-1200, AL-1250 or the Sika®
Hand Pump. As soon as injection resin oozes out of the next injection port, the first
one is sealed and injection process is continued from next port.
Construction

For horizontal crack, injection should start from any of the ends and to be continued
and completed till the last port is used. For vertical crack, injection should start from
the lowest port and continued upwards.

After completion of the injection process, the injection ports as well as the sealing
materials between the ports are removed.
®
Cleaning of Tools Clean all tools and application equipment with Sika Colma-Cleaner immediately
after use. Hardened / cured material can only be mechanically removed.
Potlife 1 kg mass (According ASTM C 881)
Temperature Time
+30°C ~ 50 min

Notes on Application / Maximum width of cracks to be injected: 5 mm.


Limitations ®
Sikadur -52 LP (IN) is suitable for dry and moist condition.
All technical data stated in this Product Data Sheet are based on laboratory tests.
Value Base Actual measured data may vary due to circumstances beyond our control.

For information and advice on the safe handling, storage and disposal of chemical
Health and Safety products, users shall refer to the most recent Material Safety Data Sheet containing
physical, ecological, toxicological and other safety-related data.
Information
The information, and, in particular, the recommendations relating to the application
Legal Notes and end-use of Sika products, are given in good faith based on Sika's current
knowledge and experience of the products when properly stored, handled and
applied under normal conditions in accordance with Sika’s recommendations. In
practice, the differences in materials, substrates and actual site conditions are such
that no warranty in respect of merchantability or of fitness for a particular purpose,
nor any liability arising out of any legal relationship whatsoever, can be inferred
either from this information, or from any written recommendations, or from any other
advice offered. The user of the product must test the product’s suitability for the
intended application and purpose. Sika reserves the right to change the properties
of its products. The proprietary rights of third parties must be observed. All orders
are accepted subject to our current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data Sheet for the product
concerned, copies of which will be supplied on request.

Sika India Pvt. Ltd. Phone +91 33 2447 2448/2449


Commercial Complex II Telefax +91 33 2468 8688/2665
620, Diamond Harbour Road ind.sika.com
Kolkata, 700 034, India [email protected]

3 Sikadur®-52 LP (IN) 3/3