Installation Instructions Bulletin 237053A

Revision C

Connectors
for HELIAX® HJ12-50 Coaxial Cable

3-1/8” EIA-flange,
gas-pass

4
3
7/8” EIA-flange

2
3-1/8” EIA-flange,
gas-block

1
Inches
100
90
1-5/8” EIA-flange

80
70
60
50
40
30
20
Millimeters

N-female
1 2
Cut cable end square. Trim cable jacket.

2”
(51 mm)

3
Add gasket, grease, and
clamping nut.

3/16”
(5 mm)

4
Remove burrs and
debris from conductors.

5 6
Cut outer conductor to Gently bend and flatten tabs.
form tabs.

3/16”
(5 mm)

7
Trim protruding tabs.
8
Screw stub into inner
conductor, cut 8 V-
notches, and reposition
stub.

9
Bend tabs into stub
slots and gently flatten
remaining tabs.

10 3-1/8” EIA-flange,
gas-block
9/16”wrench
72-108 lb•in
Outer
flare ring
Install inner connector, (8-12 N•m)
flare ring, and insulator.

Inner
Inner connector- flare
insulator assembly ring

5/8”wrench
72-108 lb•in 3-1/8” EIA-flange,
Flare ring
(8-12 N•m) gas-pass Insulator

Inner connector

7/16”wrench
64-96 lb•in 1-5/8” EIA-flange
(7-11 N•m)
Insulator

Flare ring

Inner connector
5/8”wrench
10 64-96 lb•in
(7-11 N•m)
7/8” EIA-flange
Insulator
Flare ring
Install inner connector,
flare ring, and insulator.

Inner connector

7/8”wrench Outer body


72-108 lb•in
N-female
(8-12 N•m)
Flare ring

Inner connector

11 12
Add O-ring, grease, and Tighten assembly.
outer body

3-1/8” EIA-flange

12
Tighten assembly.

36-54 lb•ft 36-54 lb•ft 32-48 lb•ft


(48-72 N•m) (48-72 N•m) (45-65 N•m)

1-5/8” EIA-flange 7/8” EIA-flange N-female

Notice: Andrew disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.

Andrew Corporation Telephone: 708/349-3300 Customer Service, 24 hours: U.S.A. • Canada • Mexico: 1-800/255-1479
10500 West 153rd Street FAX (U.S.A.): 1-800-349-5444 U.K.: 0800 250055 • Republic of Ireland: 1 800 535358 Printed in U.S.A. 7/98
Orland Park, IL U.S.A. 60462 Internet: http://www.andrew.com Other Europe: +44 1592 782612 Copyright © 1998 by Andrew Corporation

You might also like