Series 8171: Post Type Bushings

Post type bushings are used to supply power to lead-ins for Ex d enclosures. They are sealed to prevent flame propagation during an explosion and are insulated from the enclosure wall. They come in versions with split post, clamp, or soldered connections. They can handle voltages up to 1000V and currents up to 630A. Selection depends on factors like cross section, number of studs, current rating, and connection type.

Uploaded by

Majdi Belguith
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views5 pages

Series 8171: Post Type Bushings

Post type bushings are used to supply power to lead-ins for Ex d enclosures. They are sealed to prevent flame propagation during an explosion and are insulated from the enclosure wall. They come in versions with split post, clamp, or soldered connections. They can handle voltages up to 1000V and currents up to 630A. Selection depends on factors like cross section, number of studs, current rating, and connection type.

Uploaded by

Majdi Belguith
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Post Type Bushings

Series 8171
E9
> Means of supplying power to
lead-in for Ex d enclosures
> Sealed to prevent propagation
of flame on explosion and E9
insulated from wall
> Versions with
– split post connection
– clamp connection E9
– soldered connection
> For voltages up to max. 1000 V
and currents up to max. 630 A
E9

E9
www.stahl.de

E9
Series 8171 E9

03149E00

E9
The bushings are permitted to be used as current feeders
in enclosures with type of protection ”flameproof”. They are fitted
puncture-proof and insulated into the enclosure wall.
Duct bolt is located in the middle of a ring nut and the parts are E9
bonded with a high-quality, track resistant insulating material
(epoxy resin) to form an inseparable unit. For the connection points
in the Ex e enclosure increased creepage paths and air gaps
according to IEC/EN 60079-7 are valid. The bushings have to be E9
secured against self-loosening.

ATEX / IECEx
Zone 0 1 2 20 21 22 E9
For use in x x

E9

E9

E9

WebCode 8171A
E9
2017-09-21·EK00·III·en Components for System Solutions E9/1
Post Type Bushings
Series 8171

Selection Table
Post type bushings
Rated Number Current Rated voltage Connector thread Cross-section Ordering Weight
cross of studs (post) code
section multi-strand single-strand
(flexible)
[mm2] [A] [V] [mm] [mm2] [mm2] kg
1 1 10 400 M10 x 1 Z: 2.5 Z: 2.5 8171/20-ZL 0.011
L: 1.0 L: 1.5
2,5 1 10 400 M10 x 1 Z: 2.5 Z: 2.5 8171/20-ZG 0.011
G: 2.5 **) G: 2.5 **)
1 26 400 M15 x 1.5 A: 2.5 A: 2.5 8171/17-AL 0.225
L: 2.5 L: 2.5
1 54 400 M14 x 1.5 A: 2.5 A: 2.5 8171/15-AA 0.330
1 54 630 M15 x 1.5 A: 2.5 A: 2.5 8171/02-AA 0.034
1 54 630 M15 x 1.5 K: 2,5 K: 4 8171/01-KK 0.330
6 17 400 M42 x 1.5 R: 4 R: 6 8171/06-RL 0.150
L: 2,5 L: 4
1 54 800 M15 x 1.5 A: 2.5 A: 2.5 8171/42-AA 0.040
4 4 54 500 M42 x 1.5 R: 4 R: 6 8171/14-RR 0.195
6 1 54 800 M15 x 1.5 A: 2.5 A: 2.5 8171/43-AB 0.051
B: 6 *) B: 6 *)
16 1 120 800 M20 x 1.5 A: 2.5 A: 4 8171/48-AB 0.140
B: 10 *) B: 10 *)
25 1 250 1000 M42 x 1.5 K: 25 K: 35 8171/07-KB 0.350
B: 35 *) B: 35 *)
35 1 250 1000 M42 x 1.5 K: 35 K: 50 8171/09-KB 0.700
B: 35 *) B: 35 *)
70 1 200 1000 M42 x 1.5 C: 70 C: 95 8171/51-CB 0.520
B: 120 *) B: 120 *)
150 1 250 1000 M42 x 1.5 D: 150 D: 150 8171/56-DB 0.530
B: 150 *) B: 150 *)
240 1 630 1000 M42 x 1.5 Flachband max. 25 x 30 mm 8171/55-FF 1.800
*)with cable lug
**) with cable lug thread M3
Comments: Type of connection in an Ex e enclosure 8171/..-á .
Type of connection in an Ex d enclosure 8171/..-.á
Further information on the different types of connection:
see Terminals
Earthing terminals
Rated Number Current Rated voltage Connector thread Max. conductor capacity Ordering Weight
cross of studs (post) code
section flexible single-wire or
(flexible) multiwire

[mm2] [A] [V] [mm] [mm2] [mm2] kg


16 -- -- -- M20 x 1.5 16 25 8171/PE-16 0.140
50 *) 50 *)
50 -- -- -- M33 x 1.5 50 70 8171/PE-50 0.200
50 *) 50 *)
*) with cable lug

E9/2 Components for System Solutions 2017-09-21·EK00·III·en


Post Type Bushings
Series 8171
E9
Approvals
Marking
IECEx Ex db eb II, Ex db eb I
Europe (ATEX) E II 2 G Ex db eb IIC Gb

Certificates
E I M2 Ex db eb I Mb
Ex db eb II, Ex db eb I
E9
IECEx IECEx PTB 06.0080U
Europe (ATEX) PTB 00 ATEX 1066 U
Further certificates Canada (CSA), Belarus (Gospromnadzor)

Technical Data E9
Electrical data
Rated operational 400, 500, 690, 1000 V, see selection table
voltage Ue
Rated operational max. 630 A, see selection table
current Ie E9
Ambient conditions
Ambient temperature - 55 ... + 130 °C
Mechanical data
Material
Post terminal 8171/..-.. brass E9
8171/55-FF, 8171/56-DB copper
Insulating material Epoxy resin
Number of post terminal 1-, 4- and 6-pole
Terminal capacity Terminal capacity:
Flat cable:
0.75 ... 300 mm2
25 x 30 mm E9

Terminals
Design Symbol Description Design Symbol Description
A Hexagon head screw with spring L Solder socket
E9
washer and clamp

07346E00 07344E00

B Cheese hd. or hex. hd. screw with R Cap or hood type terminal (round) on E9
spring washer split post
(permissible only on Ex d side)
07339E00 07337E00

C Saddle clamp to DIN 46 223 Z Cheese head screw with spring


washer and clamp
E9
07342E00 07341E00

K Split post with hexagon nut and F Flat terminal


pressure plate DIN 22 412

07340E00
E9
07343E00

D Terminal piece for cable bracket G Thread connector


connection

07345E00
06790E00
E9

E9

E9

E9
2017-09-21·EK00·III·en Components for System Solutions E9/3
Post Type Bushings
Series 8171

Fitting
D
> 2,5

Ex e

Ex d

06367E00 09143E00 09117E00

Principles of construction Mounting arrangement Illustration of creepages

Instructions for fitting the feed-through connectors:

When fitting feed-through connectors to a Flameproof protection type enclosure, the requirements of IEC/EN 60079-1 must be
observed.

The number of threads available must be at least 5. If the enclosure volume is ≥ 100 cm3 , then the thread depth must be
at least 8 mm.
The tapped holes into which the feed-through connectors will be screwed must fulfil the mimimum requirements
of Section 5.3, table 3.

The feed-through connectors are screwed in from the inside of the flameproof enclosure and must be prevented from rotating or
unscrewing (e.g. with a locking plate or by gluing the threaded surface).

When screwing in the feed-through connectors, the specified tightening torques must be observed to avoid any damage.
If necessary, use spacers to align the terminal positions.
Further, when fitting the feed-through connectors, the air gaps and tracking distances must be related to the rated voltage.
If the sides of the enclosure are too thick, the tracking distances can be reduced to an impermissible value. This can be avoided by
reducing the thickness of the enclosure side (see sketches).

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations

03642E00 04526E00 04624E00 04625E00 04626E00

8171/01-KK 8171/02-AA 8171/07-KB 8171/14-RR 8171/06-RL


8171/15-AA 8171/09-KB
8171/42-AA

E9/4 Components for System Solutions 2017-09-21·EK00·III·en


Post Type Bushings
Series 8171
E9
Dimensional Drawings (All Dimensions in mm) - Subject to Alterations
g1

E9
L G

E9

l1
l2
g2 E9
SW

e
E9
03650E00 03651E00 03652E00 04623E00 04622E00 04621E00

8171/17-AL 8171/20-ZL 8171/43-AB 8171/51-CB 8171/55-FF 8171/56-DB


8171/48-AB

E9

E9

E9

07347E00 03127E00 E9
8171/PE-16 8171/PE-50
Type L l1 l2 G g1 g2 e SW
8171/01-KK 55.5 9.5 24.5 M15 x 1.5 M7 x 0.75 M7 x 0.75 19.6 17
8171/02-AA 53 9.5 23 M15 x 1.5 M4 M4 19.6 17 E9
8171/06-RL 47 12.5 11 M42 x 1.5 M7 x 0.75 d 4.2 53.1 46
8171/07-KB 99.5 11 31.5 M42 x 1.5 S18 x 1.5 M12 53.1 46
8171/09-KB 106.5 11 31.5 M42 x 1.5 S22 x 1.5 M12 53.1 46
8171/14-RR 78.5 11 30 M42 x 1.5 M8.5 x 1 M8.5 x 1 53.1 46
8171/15-AA 49.5 13.5 19 M14 x 1.5 M4 M4 19.6 17 E9
8171/17-AL 33 9.5 7 M15 x 1.5 M4 d2.5 19.6 17
8171/20-ZL 39 10.5 12.5 M10 x 1 M4 d 1.5 16.2 14
8171/42-AA 63.5 9.5 29.5 M15 x 1.5 M4 M4 19.6 17
8171/43-AB 69.6 6.5 29.5 M15 x 1.5 M4 M5 19.6 17
8171/48-AB 68.3 10.5 26.3 M20 x 1.5 M5 M6 25.4 22 E9
8171/51-CB 102 11 31.5 M42 x 1.5 M10 x 1 M12 x 1.75 53.1 46
8171/55-FF 175 11 84.5 M42 x 1.5 M20 x 2.5 M20 x 2.5 53.1 46
8171/56-DB 120 11 32 M42 x 1.5 M12 x 1.75 M12 x 1.75 53.1 46
8171/PE-16
8171/PE-50
47.6
52.6
20
39
27.6
13.6
M20 x 1.5
M33 x 1.5
M6
M6
M6
M6
27.7
47.3
24
41
E9

We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice.
The illustrations cannot be considered binding.
E9
2017-09-21·EK00·III·en Components for System Solutions E9/5