0% found this document useful (0 votes)
55 views

Technical Speci Cation: Product Specification

This product specification document provides details about an insulation piercing connector called the SLIW52. The SLIW52 can connect both aluminum and copper conductors ranging from 16-150 mm2 for the main conductor and 1.5-16 mm2 for the branch conductor. It has a test voltage of 6kV/50Hz/1 min in water and allows for live line installation without removing insulation from the conductors. Key features include a fully insulated bolt, piercing of both conductor insulations with a single bolt action, and compliance with EN 50483-4:2009 standards.

Uploaded by

Miguel Garza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views

Technical Speci Cation: Product Specification

This product specification document provides details about an insulation piercing connector called the SLIW52. The SLIW52 can connect both aluminum and copper conductors ranging from 16-150 mm2 for the main conductor and 1.5-16 mm2 for the branch conductor. It has a test voltage of 6kV/50Hz/1 min in water and allows for live line installation without removing insulation from the conductors. Key features include a fully insulated bolt, piercing of both conductor insulations with a single bolt action, and compliance with EN 50483-4:2009 standards.

Uploaded by

Miguel Garza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

1/2

PRODUCT SPECIFICATION
12/10/2020

Insulation piercing connector

SLIW52

Code SLIW52
GTIN 6438100312114
Name Insulation piercing connector
16-150 mm² / 1.5-16 mm², Waterproof
Description SLIW52 is for use with insulated
aluminium or copper conductors. Fully
insulated bolt provides safe live line
working. Both main and branch conductor
insulations are pierced by single bolt
action. Test voltage 6 kV/50 Hz/1 min in
water. Connector's design enables live line
installation without peeling insulation
from conductor.
Vendor

Technical speci cation

Certi cates
Standards: EN 50483-4:2009 

Dimensions
Net Weight: 0.065 kg
Main conductor mm²: 16-150 
Branch conductor mm²: 1,5-16 
Conductor diameter mm: 7.0-18.6 / 3.0-7.8 

Electrical values
Highest system voltage: 1 kV
Test voltage in water: 6 kV / 50 Hz / 1 min 

Mechanical
Tightening torque: 11 Nm

Others
ETIM Class: EC001062 

Ensto Group P.O. Box 77 email: [email protected] www.ensto.com


06101 Porvoo phone: +358 204 76 21
Finland
2/2

ETIM 7 Technical speci cation

etim
Nominal cross section main conductor SE: 16 ... 150 mm²
Nominal cross section main conductor SM: 16 ... 150 mm²
Nominal cross section branch conductor
1.5 ... 16 mm²
SE/RE:
Nominal cross section branch conductor
1.5 ... 16 mm²
SM/RM:
Material main conductor: Aluminium/copper 
Material branch conductor: Aluminium/copper 
Terminal insulated: True 
Clamping channel opening main conductor: Both sides open 
Clamping channel opening branch
One side open 
conductor:
Surface protection: Tinned 
Type of connection: Insulation piercing connector IPC 

Packaging

Pallet package
Unit: pcs 
Package size: 3780 
Depth: 1200 mm 
Width: 800 mm 
Height: 1080 mm 

Default package
Unit: pcs 
Package size: 60 
Depth: 380 mm 
Width: 260 mm 
Height: 130 mm 
Weight: 3.92 kg 
Volume: 12.844 l 

Ensto Group P.O. Box 77 email: [email protected] www.ensto.com


06101 Porvoo phone: +358 204 76 21
Finland

You might also like