0% found this document useful (0 votes)
1K views12 pages

Ex Long Short Stroke MKII Instruction Manual-022-UK

The document provides instructions for HB Products' Ex Long & Short stroke linear position transmitters. It describes the key features, measuring principle, technical specifications, approvals, design, electrical connection, LED indicators, calibration instructions, and installation of the position transmitters. The position transmitters are designed for linear position measurement in compressors and provide a 4-20 mA output signal. They have approvals for use in hazardous explosive atmospheres including ATEX and IECEx certifications.

Uploaded by

Tom Wtom
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views12 pages

Ex Long Short Stroke MKII Instruction Manual-022-UK

The document provides instructions for HB Products' Ex Long & Short stroke linear position transmitters. It describes the key features, measuring principle, technical specifications, approvals, design, electrical connection, LED indicators, calibration instructions, and installation of the position transmitters. The position transmitters are designed for linear position measurement in compressors and provide a 4-20 mA output signal. They have approvals for use in hazardous explosive atmospheres including ATEX and IECEx certifications.

Uploaded by

Tom Wtom
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Instructions manual

Ex Long & Short stroke – LPI POSITION


TRANSMITTER MKII
For linear position measurement in compressors

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 1 / 12


Revision history
Version Date Initials Description
Version 1.0 12.09.2016 MME This is the first version of the Ex manual for SA96DX-I/Ex and
SLC-M1/25/Ex
Version 2.0 26.01.2017 MME ATEX and IECEx certificates updated with issued certification
from Tüv.
Version 2.1 20.03.2017 MME Plug for IP67 version is updated with two references.
Version 2.2 07.08.2017 MME Reference for the European parliament and council updated to
match the new 2014/34/EU

*Note: For earlier certificate number: DEMKO 05 ATEX 135657, IECEx ULD 06.0009 refer to old Ex manual:
Ex Long_Shortstroke Manual 130213.pdf

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 2 / 12


Table of Contents
Introduction ..................................................................................... 4
Key features ..................................................................................... 4
Measuring principle ......................................................................... 4
Technical data.................................................................................. 5
Intrinsically safe ratings ................................................................... 5
Approvals ......................................................................................... 6
Design and function ......................................................................... 6
Electrical connection ....................................................................... 6
LED indication .................................................................................. 7
Calibration instructions: .................................................................. 7
ATEX certificate ............................................................................... 8
IECEx Certificate............................................................................... 9
Installation ..................................................................................... 10
Installation Example ...................................................................... 11
Declaration of conformity ............................................................. 12

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 3 / 12


Introduction
HB Products’ linear position sensors designed for The sensors is unique, with a short body length
position control on industrial compressors and fast response time.

Key features
- Saves on assembly time and - Rugged stainless steel construction
manufacturing costs as magnet or target
tube need not be installed. - Produced to comply with ATEX/IECEX and
standards.
- Small transducer body length to stroke
ratio.

Measuring principle
Non-contact True Position Measurement with Inductive Eddy Current Technology.
HB Products’ innovative electronics has made it possible to use alu as the target material, which in many
applications makes it possible to cut down on manufacturing costs and avoid mounting a magnet.

The Eddy Current non-contact measuring principle has been used for displacement and position sensing on
industrial applications for more than 30 years.

Function
Eddy current transducer performance is dependent on the impedance coupling between the
electromagnetic field in the sensor coil and the eddy currents in the conductive target (see illustration
below). Sensor performance is related to the change in sensor coil impedance over the calibrated range of
target motion.
The electrical parameters of target material resistivity and permeability determine the performance
capability of inductive measuring systems. Both magnetic and nonmagnetic materials can provide high
output sensitivity in terms of impedance change per unit of target displacement. Typically, aluminium has
been used as the target material since steel has a lower output and needs more accurate circuit tuning.
Temperature Compensation is dynamic and measured automatically by the sensor Coil.

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 4 / 12


Technical data
Supply voltage and load: Ambient temperature range:
12-28V DC The ambient temperature range is:
Max 450mW T5: -20°C < Ta < +70 °C
T6: -20°C < Ta < +70 °C
Signal output:
4-20 mA IP-degree:
The IP degree is as standard: IP65
Measuring range:
SA96DX-I/Ex: IP67:
100 – 1000mm depending on type In case where a DIN plug e.g. Phonix Contact art.
NO. SAC-4P-3,0-PUR/AD - 1438956 or Binder art.
SLCD-M1/25/Ex: NO. 31 5235 500 000 is used the IP degree is:
5-100mm depending on type IP67

Device category: Pressure:


The device category is: 2G for Zone 1 Max 150 bar

Type of protection: Current draw:


The type of protection is: ib Max 50 mA

Gas resp. gas group: Update time:


The gas group is: IIC 50m.sec ± 10m.sec

Temperature class: Temperature coefficient:


The temperature class is: T5/T6 Better than 40ppm/°C

Intrinsically safe ratings


Intrinsically safe ratings of the positions sensors are:

 Maximum voltage (Ui) = 28V


 Maximum Current (li) = 116mA
 Maximum Power (Pi) = 585mW
 Internal Capacitance (Ci) = 22nF
 Internal Inductance (Li) = 1mH

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 5 / 12


Approvals
The sensor complies with the approvals below

IECEx and ATEX


EMC Test
EMC Emission EN61000-3-2
EMC Immunity EN61000-4-2
Vibration resistance:
IEC 68-2-6, 10g, 10 to 2000Hz
Environmental test, incl.
Damp heat cyclic, Low storage temperature, Sinus vibration, Shock test, Dry heat test, and Cooling test.

Design and function


The sensor consists of a pressure-proof stainless steel pipe (in which the sensor coil is mounted) connected
to the electronic housing by a cable.
All components are fully sealed with two compound potting materials. In the sensor coil, this eliminates any
risk of short circuit, and in the electronic housing this eliminates any risk of condense.

SA96DX-I/Ex sensor has a measuring range from 100 to 1000 mm.


SLCD-M1/25/Ex sensor has a measuring range from 5 to 100 mm.
The signal transmitted is a 4 - 20 mA analogue signal.
Cable connection is a DIN plug.

Electrical connection
DIN 43 650 Connector
DIN Plug connection:
1 = Supply +12 to 28V DC
2 = Common
3 = 4-20mA Output

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 6 / 12


LED indication
Normal operation:
When the sensor is mounted and operating, the compressor capacity is indicated. The position is indicated
in a range of 0-100%, corresponding to 4..20 mA.

SA96DX-I/Ex SLCD-M1/25/Ex/Ex

Calibration instructions:
Calibration must be done before operation:
1. Before connecting voltage to the LDS check wiring connections are correct on the plug.
2. Apply supply voltage for a minimum of 1 minute before calibration.
3. Enable calibration mode by pressing the calibration button for 5 seconds.
4. Move slide valve to 0% position and push calibration button ONCE.
5. Observe: The red LED will light up constantly (ON) for some seconds. When the red LED flashes it will
indicate that the unit is ready for 100% calibration.
6. Now move the slide valve to 100% position and push the calibration button TWICE. The red LED will flash
rapidly.
7. Observe: When the red LED goes off the calibration procedure is complete.

Note.
The LED`s power down after 5min (no flashing) …….To activate the LED’s push the button once.
The green LED indicate end position ……. <1% = green LED flash, between 1 to 99% green LED is OFF, >99%
= green LED is ON.
The red LED indicate power up and show status during calibration acc. to the calibration instruction.

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 7 / 12


ATEX certificate

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 8 / 12


IECEx Certificate

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 9 / 12


Installation

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 10 / 12


Installation Example

HB Products A/S – Bøgekildevej 21 – DK8361 Hasselager – [email protected] – www.hbproducts.dk 11 / 12

You might also like