The Experts for industrial
Sealing technology
Introduction...
Hi- Tech Seal Pvt. Ltd. 2002
Ankleshwar 15,000
Hi- Tech
Hi- Tech
HTS /M44
HTS /M45
HTS /M65
HTS /M46
HTS /M65S
HTS /20M
HTS /20R
HTS /20C
HTS /20S
HTS /open
HTS /Close
HTS /50U
HTS /MG1
HTS /53U
HTS /12,13
HTS /82B
HTS /82W
HTS /80IBO
HTS /80IBV
HTS /80UU
HTS /75U
HTS /M70W-2
HTS
HTS 80B
HTS /87U
HTS /87W
HTS /150
HTS /150S
HTS /2U
HTS /2W
HTS /2WW
HTS /80B
HTS /85U
HTS /80A
HTS /80B
HTS /M70W-1
HTS /M70W-4
HTS /90 B 31
HTS /90 B 32
HTS /90 B 335
HTS /90 B 345
HTS /90 B 38
HTS /90 B 36
HTS /90 B 39
HTS /90 B 35
HTS /90 B 35D
API Plan 21
NOTE
Recirculation From Pump Case Through
Orifice and Cooler to Seal
Connections ‘1’ For Flushing Inlet.
API Plan 23
NOTE
Recirculation From Seal with Pumping Ring
Through Cooler and BACK to Seal
Connection ‘1’ & ‘2’ for Circulation Inlet & Outlet
API Plan 23
NOTE
Recirculation From Seal with Pumping Ring Through
Cooler and BACK to Seal
Connection ‘1’ & ‘2’ for Circulation Inlet & Outlet
API Plan 31
NOTE
Recirculation From Pump case Through clone separator
Delivering Clean Fluid
Through Cooler to Seal & Fluid with Solids Back to
Pump Suction Connection ‘1’ For Flushing Inlet
API Plan 32
NOTE
Connection ‘1’ For Flushing Inlet
External Liquid Mixes in the Pump Media
Injection to seal From External Source of Clean Liquid
The Purchase Will Specify The Fluid Characteristics and
The Vendor Shall Specify Volume Pressure &
Temperature Required
API Plan 41
NOTE
Connection ‘1’ For Flushing Inlet
Recirculation From Pump Case Through Cyclone
Separator Delivering Clean Fluid Through Cooler to Seal &
Fluid with Solids Back to Pump Suction
API Plan 52
NOTE
Connections ‘1’& ‘2’ For Flushing inlet & Outlet for Out
Board Seal Non Pressurized Thermosyphon
API Plan 53
NOTE
Connection ‘1’ & ‘2’ For Flushing Inlet & Outlet
For Outboard Seal
API Plan 54
NOTE
Connection ‘1’ & ‘2’ For Flushing Inlet & Outlet
API Plan 61
NOTE
Connection ‘1’ & ‘2’For Vent & Dran
API Plan 61
NOTE
Connection ‘1’ & ‘2’For Quenching Inlet & Outlet
API Plan 1
Note
Integral ( Internal ) Connection for Flushing Exists in The Stuffing Box
Flushing Connection need not be Provided in the Gland Plate
API Plan 2
Note
Dead Ended Seal Box With No Circulation of Flushed Fluid, Water Cooled
Stuffing Box Jacket & Throat Bushing Required When Specified
Connections ‘1’ & ‘2’ Plugged for Possible Future Circulation
API Plan 11
Note
Recirculaton From Pump Case Though Orifice To Seal
Connection ‘1’ For Flushing Inlet
API Plan 13
NOTE
Recirculation From Seal Chamber Through Orifice &
Back to Pump Suction
Connections ‘1’ For Flushing Liquid Circulation
HTS / 90 B 39
HTS / 90 B 38
HTS / 90 B 37
HTS / 90 B 42
HTS / 90 B 33D
Model : HTS /SD3 Model : HTS /DS 3A
Model : HTS /SD2 Model : HTS /DS 2A
Model : HTS /DS 1
Model : HTS /SH3 Model : HTS /SH3A
Model : HTS /SH4 Model : HTS /SH4A
Model : HTS /DB5
REFURBISHMENT OF EAGLE - BURGMANN, FLOWSERVE ( FSL), LEAK -PROOF
FLEXIBOX, SEALOL, PILLAR, EKATO, SUMIKA, ROLON SEALS
Trans Printers @ 9426334918 / 9978107392
Unit -I Plot No. 9, Rushi Complex, B/h. Gokuldham Apartment, Khwaza Chowkadi,
GIDC., Ankleshwar 393 002, Gujarat - India Tel: 02646-227236
Mobile: +(91) 99257 20427 / 99096 79711
E-MAIL: [email protected] | [email protected]
Website: www.hi-techseal.com
Unit -I Plot No. -3, Opp. India Hotal,Rajosana Ahemdabad Palanpur
Highway, Chapi - 385210 Tal Vadgam, Dist - B.K. Gujarat
Marketing Location : Dahej, Vadodara, Ahemdabad, Surat, Vapi, Mumbai, Pune, Hydrabad, Goa, Chennai, Delhi,
Baddi, Indore,Panipat, Haridwar, Dehradun, Ludhiana, J&K.....