100% found this document useful (1 vote)
672 views2 pages

How Do You Establish A Modbus - TCP Communication From A SIMATIC S7-300 - S7-400 and W... - ID - 22660304 - Industry Support Siemens

This document provides information about establishing Modbus/TCP communication from a SIMATIC S7-300/S7-400 controller. It describes using the integrated PROFINET interface or a CP 343-1/CP 443-1 communication module. It lists the available products and provides manuals and download links for configuration block libraries. The document also mentions wizards and a sample application that can help configure the Modbus/TCP connections.

Uploaded by

shashank Pathak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
672 views2 pages

How Do You Establish A Modbus - TCP Communication From A SIMATIC S7-300 - S7-400 and W... - ID - 22660304 - Industry Support Siemens

This document provides information about establishing Modbus/TCP communication from a SIMATIC S7-300/S7-400 controller. It describes using the integrated PROFINET interface or a CP 343-1/CP 443-1 communication module. It lists the available products and provides manuals and download links for configuration block libraries. The document also mentions wizards and a sample application that can help configure the Modbus/TCP connections.

Uploaded by

shashank Pathak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

(http://www.siemens.

com)
Industry Online Support
Product Support

 Home (start)  Product Support

Entry type: FAQ Entry ID: 22660304, Entry date: 12/27/2017      (19)
 Rate

How do you establish a Modbus/TCP communication from a SIMATIC S7-300/S7-400 and


where can you find further information?
Entry Associated product(s)

This entry shows you how to establish a Modbus/TCP communication from a SIMATIC S7 and where you can find further information.

STEP 7 (TIA Portal)


You can use the integrated PROFINET interface of the CPU to establish a connection between a SIMATIC S7-300/400 and a third-party device via
Modbus/TCP or use an external CP 343-1 / CP 443-1 .

The following products are offered:

Product Communication via Connection Supported function Article number


codes

Modbus/TCP PN CPU Integrated PROFINET CPU with integrated 1, 2, 3, 4, 5, 6, 15 and 6AV6676-6MB20-3AX0


interface of the CPU PROFINET interface to third- 16
party devices

Modbus/TCP CP CP 343-1 and S7 controller with external CP 1, 2, 3, 4, 5, 6, 15 and 6AV6676-6MB00-6AX0


CP 443-1 343-1 or CP 443-1 to third- 16
party devices
Table 1

The contents of the SIMATIC Modbus/TCP PN CPU are included in STEP 7 V13 Update 3 (TIA Portal) and higher. The MODBUSPN instruction is to be
found under "Instructions > Communication > Other".
In STEP 7 (TIA Portal) V14 SP1 the Help for the MODBUSPN V2.0 instruction is shown for the MODBUSPN V1.1 instruction. To obtain the Help for the
MODBUSPN V1.1 instruction you should get in touch with  Technical Support (https://support.industry.siemens.com/cs/ww/en/sc/2090).

The contents of the SIMATIC Modbus/TCP PN CP are included in STEP 7 (TIA Portal) V14 and higher. The MODBUSCP instruction is to be found under
"Instructions > Communication > Communications Processor > MODBUS TCP".

Use of this instruction is charged and must be licensed separately on each CPU. For license ordering, please get in touch with your Siemens sales partner.
The CD then supplied includes the SOFTWARE REGISTRATION FORM which you use to call the license code. You do not need to run the setup on the
CD for TIA Portal. This is only necessary for STEP 7 V5.x.

Manual SIMATIC Modbus/TCP PN CPU (STEP 7 (TIA Portal))


modbustcppncpu_en.pdf (867.3 KB) (/cs/attachments/22660304/modbustcppncpu_en.pdf)

STEP 7 V5.x
You have two communication options for establishing a connection between a SIMATIC S7 and a third-party device using Modbus/TCP:

Via an external CP 343-1 or CP 443-1


Via the integrated PROFINET interface of the CPU or H-CPU

Both communication options can be used for non-redundant and for redundant Modbus/TCP communication.

The products below are offered.

Product Communication via Connection Supported function Article number


codes

Modbus/TCP CP CP 343-1 and S7 controller with external CP 1, 2, 3, 4, 5, 6, 15 and 6AV6676-6MB00-6AX0


CP 443-1 343-1 or CP 443-1 to third- 16
party devices

Modbus/TCP CP Redundant CP 343-1 and S7-400 H-Station or S7- 1, 2, 3, 4, 5, 6, 15 and 6AV6676-6MB30-3AX0


CP 443-1 300/400 station with 2 CPs to 16
third-party devices

Modbus/TCP PN CPU Integrated PROFINET CPU and 1, 2, 3, 4, 5, 6, 15 and 6AV6676-6MB20-3AX0


interface of the CPU and H- H-CPU with integrated 16
CPU PROFINET interface to third-
Modbus/TCP PN CPU party devices 1, 2, 3, 4, 5, 6, 15 and 6AV6676-6MB10-0AX0
Redundant 16

Modbus/TCP 20 SENTRON Integrated PROFINET CPU with integrated 4 (for reading out the 6AV6676-6MA30-0AX0
PAC interface of the CPU PROFINET interface up to 20 base type 3 and the
SENTRON PAC energy meters)
6 (for resetting the
Modbus/TCP 100 SENTRON CPU with integrated energy meters) 6AV6676-6MA30-1AX0
PAC PROFINET interface up to
100 SENTRON PAC

Modbus/TCP 512 SENTRON CPU with integrated 6AV6676-6MA30-2AX0


PAC PROFINET interface up to
512 SENTRON PAC
Table 2

The 3 products SIMATIC Modbus/TCP 20/100/512 SENTRON PACs make it possible to easily establish a Modbus/TCP communication with little need for
parameters between a CPU with integrated PROFINET interface and up to 512 SENTRON PAC devices (PAC4200 firmware 1.5.1 onwards and PAC3200
V2.2.1 onwards). In this case, the data of the base type 3 and energy meters are read out cyclically. In addition, the energy meters can be reset.

License request
Fill in the SOFTWARE REGISTRATION form with the "IDENT_CODE" and "License No.".
Send the form to Customer Support as a Service Request. Here you enable the checkbox "Problem with SIMATIC authorization/license".
You will ©then be sent
Siemens AGthe REG_KEY
2009-2020 activation
- Imprint code for your CPU.
(http://www.siemens.com/corporate_info) Privacy policy (http://www.siemens.com/privacy) Cookie policy (http://www.siemens.com/cookie-policy-en) /
Terms of use (http://www.siemens.com/terms_of_use)
Download Digital ID (http://www.siemens.com/digital_id_en) 0.0.0.0
There is a demo version available for downloading for the following products.

Modbus/TCP PN CPU
(Article number: 6AV6676-6MB20-3AX0)
Download:  109745187 (/cs/document/109745187/block-library-for-modbus-tcp-communication-via-the-integrated-pn-interface-of-a-simatic-cpu?
lc=en-bh)
Modbus/TCP PN CPU Redundant
(Article number: 6AV6676-6MB10-0AX0)
Download:  103475102 (/cs/document/103475102/block-library-for-a-redundant-modbus-tcp-communication-over-the-integrated-pn-interface-of-a-
simatic-h-cpu?lc=en-bh)
Modbus/TCP CP Redundant
(Article number: 6AV6676-6MB30-3AX0)
Download:  109739221 (/cs/document/109739221/block-library-for-redundant-modbus-tcp-communication-via-cp443-1-or-cp343-1?lc=en-bh)
Modbus/TCP CP
(Article number: 6AV6676-6MB00-6AX0)
Download:  109749851 (/cs/document/109749851/block-library-for-modbus-tcp-communication-via-the-cp343-1-or-cp443-1?lc=en-bh)
Modbus/TCP SENTRON PAC
(Article number: 6AV6676-6MA30-0AX0, 6AV6676-6MA30-1AX0, 6AV6676-6MA30-2AX0)
Download:  103474714 (/cs/document/103474714/block-library-for-reading-out-the-values-of-pac3200-4200-devices-over-modbus-tcp?lc=en-bh)

Note
Entry ID  60735352 (/cs/document/60735352/simatic-s7-300-s7-400%3a-wizard-for-creating-connection-data-for-modbus-tcp-communication-
(modbus-tcp-wizard-)?lc=en-bh) includes the Modbus TCP Wizard for creating the parameters for the Modbus/TCP communication.
Entry ID  49973600 (/cs/document/49973600/wizard-for-creating-connection-data-for-modbus-tcp-communication-for-reading-of-values-from-pac-
devices-with-help-of-pn-cpus-(modbus-tcp-pac-wizard-)?lc=en-bh) includes the Modbus/TCP PAC Wizard for creating the parameters for the
Modbus/TCP communication for CPUs with integrated PROFINET interface.
Entry ID  38586568 (/cs/document/38586568/communication-between-simatic-s7-and-modicon-m340-via-modbus-tcp?lc=en-bh) includes a
sample application for configuring a Modbus/TCP connection between SIMATIC S7 and Modicon M340 with the blocks from Modbus/TCP CP
and Modbus/TCP PN-CPU.

Additional Keywords
Loadable drivers, Communication blocks, Modbus, Redundancy

Security information
In order to protect technical infrastructures, systems, machines and networks against cyber threats, it is necessary to
implement – and continuously maintain – a holistic, state-of-the-art IT security concept. Siemens’ products and solutions
constitute one element of such a concept. For more information about cyber security, please visit
https://www.siemens.com/cybersecurity#Ouraspiration. (https://www.siemens.com/cybersecurity#Ouraspiration)

Also available in the following languages:


 German
 Spanish
 Chinese

Entry belongs to product tree folder(s):


 Automation Technology  Products for specific requirements  Customized Automation  Customized Software (products?pnid=14838)
 Automation Technology  Products for specific requirements  Customized Automation  Customized Software  SIMATIC Modbus/TCP
(products?pnid=14843)

Rate entry

     no rating Submit rating

Requests and feedback

What do you want to do?

You have a technical question / problem: Ask the Technical Support


 Create support request

You want to discuss in our forum and exchange experiences with other users
 Go to the Forum (/tf/bh/en)

You want to create CAx data for one or more products


 Go to the CAx download manager

You would like to send us feedback on this Entry


 Provide feedback

Note: The feedback always relates to the current entry / product. Your message will be forwarded to our technical editors working in the Online Support. In a few days, you will receive a response if your feedback
requires one. If we have no further questions, you will not hear from us.

© Siemens AG 2009-2020 - Imprint (http://www.siemens.com/corporate_info) Privacy policy (http://www.siemens.com/privacy) Cookie policy (http://www.siemens.com/cookie-policy-en) /
Terms of use (http://www.siemens.com/terms_of_use)

You might also like