0% found this document useful (0 votes)
107 views2 pages

Jet - Jet Inox - Euroinox M-P: Technical Data

This document provides technical specifications for JET centrifugal electric pumps. The pumps are self-priming and can pump liquids from 0.4 to 10.5 cubic meters per hour to a maximum head of 62 meters. They are suitable for pumping clean water with low solids content in domestic, agricultural, and small industrial applications. The pumps feature cast iron or stainless steel bodies and technopolymer impellers. Single phase models include safety components, while three phase models require external overload protection.

Uploaded by

oiboriowo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
107 views2 pages

Jet - Jet Inox - Euroinox M-P: Technical Data

This document provides technical specifications for JET centrifugal electric pumps. The pumps are self-priming and can pump liquids from 0.4 to 10.5 cubic meters per hour to a maximum head of 62 meters. They are suitable for pumping clean water with low solids content in domestic, agricultural, and small industrial applications. The pumps feature cast iron or stainless steel bodies and technopolymer impellers. Single phase models include safety components, while three phase models require external overload protection.

Uploaded by

oiboriowo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

JET - JET INOX - EUROINOX M-P

PREPARED CENTRIFUGAL ELECTRIC PUMPS

SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS


TECHNICAL DATA
Operating range:
from 0.4 to 10.5 m3/h with head up to 62 metres.
Liquid quality requirements: clean, free from solid or abrasive
contaminants, non-viscous, non-aggressive, uncrystallised and chemically
neutral, close to the properties of water.
JET M-P Liquid temperature range: from 0°C to +35°C for domestic use
(EN 60335-2-41). For other use: from 0°C to +40°C
Maximum ambient temperature: +40°C
Maximum operating pressure: 8 bar (800 kPa)
Installation: fixed in a horizontal position.
Special executions on request: different frequencies and/or voltage.
Motor protection rating: IP 44
Terminal block protection rating: IP 55
JET 151-251 T-P Insulation class: F
Standard input voltage: single phase 220/240 V / 50 Hz
three phase 230/400 V - 50 Hz

APPLICATIONS
Self priming centrifugal pump with excellent suction capacity even in the presence of air bubbles.
Suitable for pumping water with low levels of sandy impurities. Especially used in domestic water supply installations. Suitable for small farms and
gardening, small scale industrial services and where self priming is necessary.

CONSTRUCTIONAL FEATURES OF THE PUMP


Pump body in cast iron for jet pumps and in stainless steel for the jetinox and euroinox pumps
Motor support in die cast aluminium.
Impeller, diffuser, venturi tube and sand guard in technopolymer
Stainless steel wear ring.
Carbon/ceramic mechanical seal.
SINGLE PHASE VERSION: electric pump set up with pressure gauge, pressure switch, power cord with plug and three-way brass fitting for use when
connecting to a tank
THREE-PHASE VERSION: electric pumpa set up with pressure gauge, pressure switch, remote overload protection and three-way brass fitting for use
when connecting to a tank

CONSTRUCTIONAL FEATURES OF THE MOTOR


Asynchronous type, closed, with external air cooling. Rotor mounted on oversized greased-for-life ball bearings, to guarantee low noise and long life.
Incorporated thermo-amperometric protection and permanently inserted capacitor in the single phase version. It is recommended to use overload
protection for three phase motor protection, in compliance with current legislation. Manufactured pursuant to CEI 2-3 and CEI 61-69 (EN 60335-2-41).

1 4 16
MATERIALS
N° PARTS * MATERIALS

200 UNI ISO 185 CAST IRON (FOR JET)


1 PUMP BODY AISI 304 STAINLESS STEEL
(FOR JETINOX AND EUROINOX)
EUROINOX
3 FRAME DIE CAST ALUMINIUM
7 28 3
4 IMPELLER TECHNOPOLYMER A 1 4 28 7
AISI 416 STAINLESS STEEL X12 CrS13 -
7 SHAFT WITH ROTOR
UNI 6900/71

16 MECHANICAL SEAL CARBON/CERAMIC

28 OR GASKET NBR RUBBER

160 VENTURI DIFFUSER NOZZEL GROUP TECHNOPOLYMER A

* In contact with liquid


160 16 3 JET - JETINOX

DAB PUMPS reserve the right to make modifications without prior notice

59
JET 62-82-102-112-132-MP - CENTRIFUGAL ELECTRIC PUMPS FOR
DOMESTIC WATER SUPPLY
Liquid temperature range pumped: from 0 °C to +35 °C - Maximum ambient temperature: +40°C
SELF-PRIMING AND MULTISTAGE CENTRIFUGAL PUMPS

0 2 4 6 8 10 12 Q US gpm 0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 Q IMP gpm 0 2 4 6 8 10 12 14 Q IMP gpm
P H H P H
kPa m kPa m H
ft ft
400 50
40
120
160
400 40
300 30 100 120
JET 62 JET 82
80 300 30 100

200 20 80
Hs 9 60
Hs 9
8 200 20
60
7 6 8
5 40 7
4 6
100 10 3 5 40
2 100 10 4
20 3 2 20

0 0 0 0 0 0
3 3
0 0,5 1 1,5 2 2,5 3 Q m /h 0 0,5 1 1,5 2 2,5 3 3,5 4 Q m /h
0 0,2 0,4 0,6 0,8 Q l/s 0 0,2 0,4 0,6 0,8 1 Q l/s
0 10 20 30 40 50 Q l/min 0 10 20 30 40 50 60 Q l/min

0 2 4 6 8 10 12 14 16 Q US gpm 0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm 0 2 4 6 8 10 12 14 Q IMP gpm
P H P H
kPa m H kPa m H
50 ft ft
600 60 200

160
400 40 500 50 160
JET 102 120 JET 112
400 40
300 30 100
120
Hs 9 Hs 9
80 300 30 8
8
7 7 6
200 20 6 80
60 5 4
5 4 200
3 20 3
2 2
40
100 10 40
100 10
20

0 0 0 0 0 0
0 0,5 1 1,5 2 2,5 3 3,5 4 Q m3/h 0 0,5 1 1,5 2 2,5 3 3,5 4 Q m3/h
0 0,2 0,4 0,6 0,8 1 Q l/s 0 0,2 0,4 0,6 0,8 1 Q l/s
0 10 20 30 40 50 60 Q l/min 0 10 20 30 40 50 60 Q l/min

A
0 2 4 6 8 10 12 14 16 18 20 22 24 Q US gpm
D
0 2 4 6 8 10 12 14 16 18 20 Q IMP gpm A1
P H
H C
kPa m
ft
140
DNM
400 40
DNM

JET 132 120

300 30 100

80
200 20
60

H
DNA
H1

Hs 9

H2
8 7 40
H3

6
100 10 5
4
3 20
2
0 0 0 I
E F
0 1 2 3 4 5 Q m3/h
0 0,2 0,4 0,6 0,8 1 1,2 1,4 Q l/s G
0 10 20 30 40 50 60 70 80 90 Q l/min B

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906.

ELECTRICAL DATA
MODEL POWER SUPPLY P1 MAX P2 NOMINAL In CAPACITOR
50 Hz KW kW HP A µF Vc
JET 62 MP 1x220-400 V ~ 0.72 0.44 0.6 3.12 12.5 450
JET 82 MP 1x220-400 V ~ 0.85 0.6 0.8 3.8 12.5 450
JET 102 MP 1x220-400 V ~ 1.13 0.75 1 5.1 16 450
JET 112 MP 1x220-400 V ~ 1.4 1 1.36 6.2 25 450
JET 132 MP 1x220-400 V ~ 1.49 1 1.36 6.6 25 450

GROSS
DNM PACK DIMENSIONS
I Ø DNA VOLUME WEIGHT
MODEL A A1 B C D E F G IØ H H1 H2 H3 GAS GAS L/A L/B H (mc) Kg
JET 62 MP 395 390 263 108 177 192 14 111 – 239 209 193 144 9 1” 1” 440 295 235 0.031 11.9
JET 82 MP 395 390 263 108 177 192 14 111 – 239 209 193 144 9 1” 1” 440 295 235 0.031 12.1
JET 102 MP 414 390 263 108 177 192 14 111 – 239 209 203 144 9 1” 1” 440 295 235 0.031 13.9
JET 112 MP 414 390 263 108 177 192 14 111 – 239 209 203 144 9 1” 1” 440 295 235 0.031 14.9
JET 132 MP 414 390 263 108 177 192 14 111 – 239 209 203 144 9 1” 1” 440 295 235 0.031 14.9

DAB PUMPS reserve the right to make modifications without prior notice