DeviceXPlorer OPC Server
DxpSERVER series
TAKEBISHI Corporation, May 2015
TAKEBISHI Corporation 1
Corporate Profile
[Corp. Name] TAKEBISHI Corporation
[Head Office] 29 Mamedacho Nishikyogoku Ukyoku
Kyoto 615-8501, JAPAN
[Branch] Tokyo, Osaka, Nagoya, etc.
[Affiliates] Shanghai, Tianjin, Hongkong
Thailand, Netherlands
[Establish] April 24th, 1926
[Capital]2,600 million yen
[Sales] 73,000 million yen
[Employees] 560 persons
[Business ]
Industrial Equipment Semiconductors Social Infrastructure
Hongkong Shanghai Tianjin
FA System Embedded System OA System Private Brand
Kyoto
2014 Head Office
Thailand and Netherlands branches launched!
TAKEBISHI Corporation 2
Description of Business
IT System
TV System
Air Conditioner Mobile Distribution Devices
Servo Motor
IT and Social Infrastructure
IT System Industrial Equipment
15% Industrial
Elevator
Social Infra. Equipment
Solar System 15%
40% PLC
Semiconductor
Radiation Therapy Machine and Devices
Robot
30%
Electronics Devices Finishing Machines
Board
Storage
TFT Module Vision
Private PCs Semiconductor Video Copy
TAKEBISHI Corporation 3
TAKEBISHI Technologies
Enterprise Resource Planning
OPC
Cloud System Development
Manufacturing Execution System
OPC
Product System
Logging System
WEB System
Supervisory Control Energy System
And Data Acquisition Graphic
Open System development OPC Foundation VANS
Supplied hardware components Connectivity Wonderware Certified System Integrator
OPC OPC Wonderware Certified Software Provider
Control System
Process System
Embedded System
Vision Robot System
Process Automation Factory Automation Vision System
Mitsubishi EZSocket Partner
Control Panel Mitsubishi eF@ctory Partner
Wiring, Construction PLCs CC-Link Partner
Shake down COGNEX Premium Partner
Motor COGNEX System Integrator
TAKEBISHI Corporation 4
DeviceXPlorer OPC Server
DxpSERVER series
TAKEBISHI Corporation 5
DxpSERVER series
Connectivity
One Stop Open Network/Robot/NC/Database
Asia
Global Japanese/English/Korean/Chinese
High
Performance
OPC UA Next Generation Interface OPCUA
TAKEBISHI Corporation 6
DeviceXPlorer OPC Server 5.2
Accessible to 150 kinds of devices!
MITSUBISHI JTEKT OMRON YOKOGAWA HITACHI SHARP FUJI KEYENCE
MELSEC TOYOPUC SYSMAC FA-M3 EH/H Satellite MICREX KV
iQ-R Series
FANUC ROCKWELL YASKAWA PANASONIC SIEMENS TOSHIBA
MODBUS LSIS
PMC AllenBradley MP2000 FP-X Simatic-S7 V
S7-1500
MODBUS RFID・
DEVICES Open Network Robot・NC Software Energy Monitor
BCR
SLMP AnyWire MELDAS MITSUBISHI OPC DA EcoServerⅢ
CC-Link WAGO KAWASAKi OMRON DDE E-Energy
IEC60870 KEYENCE ODBC EcoMonitorLight
BACnet COGNEX DxpLink Smart Meter
HIOKI AZBIL
M-SYSMTE RKC
HAKKO CHINO
IDEC EUROTHERM
KOYO PANASONIC
3S DELTA
New! MOXA YOKOGAWA
TAKEBISHI Corporation 7
Feature of New Version
DxpSERVER can be used in 24-hour continuation operation DxpSERVER supports dynamic change of display language,
system. Hot Configuration can realize dynamic change of Support language is Japanese, English, Korea and Chinese
communication parameters without suspending communication (Traditional Chinese and Simplified Chinese).
with controller.
DxpSERVER support interpreter language “Lua“. DxpLink is TAKEBISHI original HTTP protocol. Tag data is
User can embed user logic performed in constant cycle/event. shared between DxpSERVER and communication traffic with
Realize OPC Item bridge, logging in CSV, and log trace, etc. PLC can be reduced. Remote Monitoring system can be built
easily.
TAKEBISHI Corporation 8
Feature of New Version
User can define the template with multi member variables of Administrator can define
structure, and create instance based on the template structure. user authority for operation
Generation of tags with the same structure becomes easy. of OPC Server. User
authority management
protects the system failure
by operation mistake.
The batch data writing to tag via file which is written value in Function for monitoring continuation area of PLC register. Even if
csv format. User writes the csv file path to the OPC tag, and engineer doesn’t have PLC engineering tool, engineer can be
DxpSERVER writes value to PLC. develop host system efficiently.
Using batch data writing, user can reduce OPC interface
overhead.
Test1.txt : 1,2,3,4,5,6,7,8,9,10,11,・・・
TAKEBISHI Corporation 9
Connectivity with MELSEC
Series CPU Ethernet Serial Others
Q100UDEH / Q50UDEH Q81BD-J71GP21(S)- SX
Built-in USB Port
Q26UD(E)H / Q20UD(E)H Built-in Ethernet Q80BD-J71GP21(S)- SX
Built-in Serial Port
MELSEC-Q Q13UD(E)H / Q10UD(E)H QJ71E71-100 Q81BD-J71LP21(S)-2 5
QJ71C24N
(Universal Model) Q06UD(E)H / Q04UD(E)H QJ71E71-B2 Q80BD-J71LP21(S)-2 5
QJ71C24N-R2
Q03UD(E) / Q02U QJ71E71-B5 Q80BD-J71LP21G
QJ71C24N-R4
Q01U / Q00U(J) Q80BD-J71BR11
Q25(P/PR)H Built-in USB Port Q81BD-J61BT11(N)
Built-in Ethernet
MELSEC-Q Q12(P/PR)H Built-in Serial Port Q80BD-J61BT11(N)
QJ71E71-100
(High Performance Q06(P)H QJ71C24N Q81BD-J71GF11-T2
QJ71E71-B2
Model ) Q02(P)H QJ71C24N-R2 QJ71MT91
QJ71E71-B5
Q01 / Q00(J) QJ71C24N-R4 QJ71MB91
MELSEC-Q GX-Simulator
Q12DCCPU-V Built-in Ethernet
(C Language CPU)
MELSEC-Q Q170M
Built-in Ethernet
(Motion CPU) Q172/173D(S)CPU (- S1 )
L26CPU-BT Built-in USB Port
MELSEC-L Built-in Ethernet
L02CPU LJ71C24(-R2)
FX3U(C) Built-in Serial Port
FX3G FXxx-232-BD
MELSEC-FX FX2N(C) FX3U-ENET(-L) FXxx-485-BD
FX1(S/N/NC) FXxx-232ADP
FX0(S/N) FXxx-485ADP
Q4A(R) A(1S)J71QE71(N)-T Built-in Serial Port
MELSEC-QnA Q3A A(1S)J71QE71(N)- B2 AJ71QC24(N)(-R2 /- R4)
Q2A(S/SH)(-S1 ) A(1S)J71QE71(N)- B5 A1SJ71QC24(N)(- R2 )
A4U AJ71E71(-S3) Built-in Serial Port
A3(N/A/U) A(1S)J71E71(N)-T AJ71UC24
MELSEC-A
A2(N/A/U)(S/ S H) (- S1) A(1S)J71E71(N)- B2 AJ71C24-S8
A1(N)(S/SH) A(1S)J71E71(N)- B5 A1SJ71UC24
GT16 Built-in Ethernet (UHF belt RFID)
GOT1000
GT15 GT15-J71E71-100
10 TAKEBISHI Corporation 10
Communication Performance - MELSEC
High Performance (30K - 50K words/sec)
The universal model of MELSEC-Q series became high-speed of cycle time (scan time) and external communication.
Since 960-word data can be read in one communication message, when scan time is 5 ms and physical communication
time is 10 ms, 960 words can be acquired in 25 ms and nearly 40K [words/s] high-speed communications are possible.
Load sharing by multi-port communication
Ethernet unit or built-in Ethernet of MELSEC-Q series has 16 Ethernet TCP
port. OPC Server can have multi port settings and distribute communication
load. The communication load to single port will be reduced.
[ Test Environment ]
5.0sec
PC System
MELSEC-QnU series
CPU Intel(R) Core(TM) i7 CPU 860
Ethernet communication Performance Sample
4.0sec RAM 3GB
OS Windows 7 Professional 32bit OS
OPC Server DXP2007 Series (Ver. 4.2)
3.0sec OPC Client VC++ OPC Client
PLC System
CPU MELSEC Q06UDHCPU
2.0sec
Ethernet Unit QJ71E71-100 (Cross Cable Connection)
Scan Time 1ms (All point value change every scan)
1.0sec Access Area Continuation area of Data Register “D”
The data of the left table is a test result of
1K 2K 4K 8K 16K 32K 64K 128K our company, The value is not guaranteed.
points points points points points (2Port) (4Port) (8Port)
TAKEBISHI Corporation 11
MELSEC PX Developer Combination
Function Feature Merit
If user specify PX Developer project file in OPC tag for each variables of instrumentation
DxpSERVER group setting, DxpSERVER tag is imported automatically, and user can rise
accesses PX Developer database and import PX the development efficiency and reduce
Developer instrumentation tag in DxpSERVER. development costs. Moreover, user can use
generic package by adoption of OPC to PA field.
Instrumentation Import
Tag Setting
Database
Instrumentation Tag of PX Developer
TAKEBISHI Corporation 12
MELSEC SYSTEM LABEL Combination
Function Feature Merit
If user specify iQ Works project file in DxpSERVER User doesn’t need to create tag settings for
group setting, DxpSERVER accesses iQ Works via system label. This combination function will
MELSOFT library and import system label tag in reduce development cost and help rapid
DxpSERVER. development of host system.
TAKEBISHI Corporation 13
OPC Client Sample Program
Quick Start for developing OPC Client
To develop OPC Client with VC++, VB.NET, VC# , we provide various samples programs.
User does not need to read OPC interface specifications carefully to develop OPC Client.
DeviceXPlorer OPC Server DxpSERVER series
OPC DA Custom Interface
OPC DA Automation Rapper RCW
TAKEBISHI Corporation 14
OPC Client Packages in the world is usable
We check connectivity with OPC Client package products,
such as SCADA/DCS/CAD etc.
Type Product
SCADA InTouch/Historian (Wonderware),
GENESIS (ICONICS),
Cimplicity/iFix (GE),
RSView (Rockwell), WinCC (Siemens),
Citect SCADA (Schneider Electric),
JoyWatcher (JT Engineering),
ASTMAC (Yokogawa), Monity (MCR),
KingView (WellinTech)
CAD DELMIA (Dassault Systemes),
iCAD/VPS (Fujitsu),
Vmech (Lattice Techonology),
3DCreate (CMS), SMASH (Sanmatsu)
Other Harmonas/PREXION/DGPL (Azbil),
LabVIEW (Natinal Instruments),
Cogent DataHub (Cogent),
DxpLOGGER (Takebishi)
TAKEBISHI Corporation 15
New OPC server exhibition schedule
①DMS 2015 (Tokyo, Japan)
②CIIF2015 (Shanghai, China)
③SCF 2015 (Tokyo, Japan)
④OPC Foundation Seminar (USA)
OPC grows to Unified Architecture
TAKEBISHI Corporation
29, Mamedacho, Nishikyogoku,
Ukyo-Ku, Kyoto, 615-8501, Japan
TEL +81-75-325-2171, FAX +81-75-325-2273 Web Search Engine
TAKEBISHI Corporation 16