VZ13 - Machine-level HMI

including 21 CFR Part 11 with


FactoryTalk® View Machine
Edition : Advanced Lab
Agenda

1 2 3 4
Lab Overview FactoryTalk® 21 CFR Part 11 Hands-On Lab
View ME v11.0 Overview

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 3


What is this Hands-On Lab About?
If you are experienced with building FactoryTalk® View Machine
Edition applications for PanelView™ Plus, this session allows
you to pick-and-choose from subjects related to more
advanced capabilities.

Topics include:
• Trending
• Recipes
• Data logging
• Using process faceplates and global objects
• Working with Logix extended tag properties
• Using Logix extended tag properties with runtime language switching
• Applying ActiveX controls in an application
• Creating a context-sensitive alarm system
• Designing for 21 CFR Part 11

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 4


What’s New in FactoryTalk®
View Machine Edition v11.0
Increased Display Count for PanelView™ Plus 7 Standard
FactoryTalk® View ME v11.0

Beginning with v11.0, PanelView™ Plus 7 Standard


supports up to 100 total displays in an application

• Increased from 50 to 100 total display limit


• 50 on-top displays, 50 replace displays per application
• Extends range of applications for PanelView™ Plus 7 Standard
• New option for application requiring a 6” terminal –
PanelView™ Plus 7 Standard can now replace 6”
PanelView™ Plus 6 terminals
• PanelView™ Plus 7 v11.0 firmware required

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 6


Optimized Audit Log Messages
FactoryTalk® View ME v11.0

The number of audit messages logged for operator


actions is optimized in v11.0, reducing message
overload and ‘clutter’ in the audit log

• Reduction of duplicate audit messages for operator actions such as:


• Tag writes
• Recipe downloads
• Creates a more readable operator action audit log
• When using the onboard audit log on a PanelView™ Plus, this
optimization reduces the frequency of on board audit log
management

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 7


Graphic Performance Improvement for PanelView™ Plus 7 Performance
FactoryTalk® View ME v11.0

Graphic rendering optimization can result in improved


display load speed on PanelView™ Plus 7 Performance

• Graphic rendering speed improvement for PanelView™ Plus 7


Performance HMI
• Does not impact PanelView™ Plus 7 Standard HMI – applies to
PanelView™ Plus 7 Performance HMI only
• Included in v11.0, with patch for FactoryTalk® View ME/PanelView
Plus 7 Performance v8.20-v10.0 available now in Knowledgebase
AID 1073963
• May 2018 Patch Rollup must be installed before Sept 2018
patch
• Display rendering time can be improved by 10% – 20%

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 8


Runtime File and Application Backup Version ID
FactoryTalk® View ME v11.0

Assist developers working with different versions of


FactoryTalk® View ME, tools will now show the
version of an .MER or .APA

• Application Manager for FactoryTalk® View ME shows the version


of an .MER or .APA file being worked with
• When restoring an .MER or .APA file to a Studio project, users can
see the version of the runtime / archive file prior to restoring the
entire application
• File Transfer Utility shows runtime file version, letting you verify that
the proper version of PanelView™ Plus firmware is installed on a
PanelView™ Plus prior to download
• New FactoryTalk® View ME Version Reader tool used separately
from FactoryTalk® View Studio can quickly check the version of
.MER and .APA files
• No FactoryTalk® View Studio dependencies – Studio install is not
required to run Version Reader tool

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 9


FactoryTalk® View Studio Software Usability Enhancements
FactoryTalk® View ME v11.0

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 10


OS Platform Support
FactoryTalk® View ME v11.0

FactoryTalk® View v11.0 continues support for Microsoft operating systems and updates

OS Support SQL Server Support No Longer Support


Windows Server 2016 (64 bit) (for datalog and FactoryTalk® Alarms
& Events) Windows XP (8.10)
Windows Server 2012 R2 (64 bit)
Windows Vista (8.00)
Windows Server 2008 R2 (64 bit) MSSQL 2017 (64 bit)
MSSQL 2016 (64 bit) Windows Server 2003 (8.00)
Windows 10 (32 / 64 bit)
Windows Server 2012 (10.00)
Windows 7 SP 1 (32 / 64 bit) MSSQL 2014 (32 / 64 bit)
Windows 8 (10.00)
MSSQL 2012 (32 / 64 bit)
MSSQL 2008 R2 (32 / 64 bit) Windows 8.10 (10.00)

MSSQL 2008 (32 bit)

Latest operating system info can be found at the


Rockwell Automation Compatibility and Download Center
PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 11
21 CFR Part 11 Overview
FactoryTalk® View Machine Edition 21CFR Part11 Compliance Overview
Requirement Description FTView ME
Data Integrity When exporting audit log information to a CSV log file (10.00) that is stored on removable media, if that media is ○ (8.20)
unavailable or full, the audit log information will not be exported. The end user must create a process to manage the ○ (9.00)
audit logs. ◒ (10.00)
◒ (11.00)
When forwarding audit log information to FactoryTalk® AssetCentre there is no buffering or caching of audit messages
in the local system. If the network connection to the FactoryTalk® AssetCentre system is lost, operator audit information
sent while the systems are disconnected will be lost.
Audit Trail, FactoryTalk® View ME records audit log information as operator actions occur. All tag writes are audited. System ◒ (8.20)
Change Control actions, such as user logging in to acknowledge an alarm, are also audited. ◒ (9.00)
Support ● (10.00)
● (11.00)
System Access, FactoryTalk® View ME uses FactoryTalk® Security as the user authentication service. FactoryTalk® Security can be ● (8.20)
Identification integrated with a Microsoft Active Directory to provide centralized user management. When integrating with Microsoft ● (9.00)
Codes & Active Directory, ex. Windows Server 2008/2012/2016 Active Directory authentication is limited to LDAP or LDAP over ● (10.00)
Passwords SSL. ● (11.00)
Electronic FactoryTalk® View ME supports electronic signature. FactoryTalk® View ME objects that write data can be configured to ● (8.20)
Signatures require an electronic signature. ● (9.00)
● (10.00)
● (11.00)
Open Systems PanelView™ Plus 6/7 are closed systems. N/A

Key ● – Meets; ◒ – Complies with considerations; ○ – Does not meet

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 13


Configure Onboard Audit Trail System
FactoryTalk® View Machine Edition 10.00

Overview
• Store up to 10,000 actions on device
• Capacity connections can be used to generate alarms
• Control system can clear audit history
Benefits
• Apply FactoryTalk® View ME in applications requiring
regulatory compliance, US 21CFR Part 11, EU Annex 11
• No requirement for FactoryTalk® AssetCentre

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 20


Onboard Audit Trail Supports Regulated Industry Applications
FactoryTalk® View Machine Edition 10.00

Overview
• Store up to 10,000 actions on device
• View history using Audit Trail List
• View single entry details using Audit Trail Detail
• Capacity tags can be used to generate alarms

Benefits Audit Trail List


• Use FactoryTalk® View Machine Edition in applications
requiring regulatory compliance such as US 21CFR
Part 11 or EU Annex 11
• No requirement for FactoryTalk® AssetCentre

Audit Trail Detail

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 21


Export Alarm History and Audit History to CSV
FactoryTalk® View Machine Edition 10.00

Overview
• Configured at design-time:
• Select what is exported (Alarm history, Audit history, or
Diagnostics)
• Provide a unique identifier for file name
• Creation triggered at runtime via tag
• CSV files are time-stamped, and tamper detectable

Benefits
• Application controls when export occurs
• Captures source data for a ‘batch record’

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 22


Where can I learn more…

• Whitepaper is available on Rockwell Automation


literature library, FTALK-WP016B-EN-P
http://literature.rockwellautomation.com/idc/groups/l
iterature/documents/wp/ftalk-wp016_-en-p.pdf
• Whitepaper contains much more detail about how to
design an application that enables 21CFR Part11
compliance

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 23


PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 24
Hands-On Lab
Hands-On Lab

• Pick and choose format


• Lab sections
• Accessing Logix Extended Properties
• Advanced Alarm Topics
• Runtime User Management
• Comparing Trends
• Using Process Faceplates
• Designing Faceplates and Reusable Objects
• Multiple Recipe Solutions
• Exploring Design Time Improvements
• Application Documenter
• How to Achieve 21 CFR Part 11

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 26


YouTube Video Playlists
FactoryTalk View SE / ME, FactoryTalk® AssetCentre, and Studio 5000 View Designer® Software

Rockwell Automation provides “how to” videos for various features in FactoryTalk® View SE
Software, FactoryTalk® View ME Software with PanelView™ Plus 7 HMI, View Designer
Software with PanelView™ 5000 HMI, and other Rockwell Automation products

▪ Created by Commercial Engineering to demonstrate


product features and how they are configured
▪ New content added monthly

▪ FactoryTalk® View Site Edition Playlist


▪ PanelView™ Plus and FactoryTalk® View Machine
Edition Playlist
▪ FactoryTalk® AssetCentre Playlist
▪ PanelView™ 5000 & Studio 5000 View Designer®
Playlist

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 27


Share your feedback
Please complete the session
survey on the mobile app

1
Download the Events ROK
mobile app

2
Select TechEd and login
Use your email and last name that
you used to register for the event.

3 Click on Schedule on the main


menu

• Select the session you are attending


• Click on the survey tab
• Complete the survey and submit

PUBLIC | TechEd | #ROKLiv e | Copy right ©2019 Rockwell Automation, Inc. 28


Thank you

www.rockwellautomation.com

You might also like