Step 1 Step 2 Step 3 Step 4 Step 5 Step 6: R 0 G 6 2 0 4 G N S X

This document provides guidance on selecting product codes for ordering liquid-cooled commercial generators and transfer switches from Generac. It outlines six steps to determine the correct codes based on factors like kW rating, engine type, voltage, fuel type, enclosure and emissions equipment. It also provides a sample product code and explanations of the code components.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views1 page

Step 1 Step 2 Step 3 Step 4 Step 5 Step 6: R 0 G 6 2 0 4 G N S X

This document provides guidance on selecting product codes for ordering liquid-cooled commercial generators and transfer switches from Generac. It outlines six steps to determine the correct codes based on factors like kW rating, engine type, voltage, fuel type, enclosure and emissions equipment. It also provides a sample product code and explanations of the code components.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

EASY ORDER SELECTION GUIDE— GENERAC LIQUID-COOLED PRODUCTS ONLY

To determine the correct product codes for a Commercial liquid-cooled generator and transfer switch
follow the steps below. A product code is required to order. To place an order, e-mail or fax the product
codes to your inside sales representative or place your order online. If you have questions, c
all1-888-Generac. Freight is FOB factory. Charges will be determined at the time of order.

STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6


kW Ratings Engine Voltage Fuel Enclosure Emission/Catalytic
e.g. (45 kW = e.g. (6.8L = 68) 120/240 1ø = A Natural Gas = N Steel = S Converter
045) 120/208 3ø = G Propane Vapor = V Aluminum = A No Catalyst = X
ALL
120/240 3ø = J Field Convertible Catalyst &
PRODUCT
277/480 3ø = K to LP = * A/F Ratio = C2
CODES
BEGIN 221 2.4L @ 1800 RPM A,G,J N* A X
WITH RG = 251 1.5L @ 3600 RPM A,G,J N* S, A X
22-60 kW 271 2.4L @ 1800 RPM A,G,J N* A X
301 1.5L @ 3600 RPM A,G,J N* S, A X
323 2.4L @ 1800 RPM A, G, J, K N* A X
363 2.4L @ 3600 RPM A, G, J, K N* S, A X
ALL 383 2.4L @ 1800 RPM A, G, J, K N* A X
PRODUCT 45 2.4L @ 3600 RPM A, G, J, K N* S, A X, C
CODES 48 5.4L @ 1800 RPM A, G, J, K N* A X, C
BEGIN 603 2.4L @ 3600 RPM A, G, J, K N, V S, A X
WITH QT=
70 6.8L @ 1800 RPM A, G, J, K N, V A X, C
70-150 kW
803 5.4L @ 3600 RPM A, G, J, K N, V A X
100 6.8L @ 2300 RPM Gear Drive A, G, J, K N, V A C
130 6.8L @ 3000 RPM Gear Drive A, G, J, K N, V A C
SAMPLE 6.8L @ 3600 RPM
150 A, G, J, K N, V A C

R G 0 6 0 2 4 G N S X

R G
PRODUCT CODE (Enter on Order Form) 1 = 22 - 30 kW - CARB emission compliant in State of California and City of Los Angeles and do not require
a catalyst. Emission compliant in State of Massachusetts.
2 = Catalyst & A/F Ratio may not be available for all models required for California and Massachusetts. Contact
your Generac representative for details on these emission requirements.
3 = Not available with catalyst. Units are not CARB Compliant and may not be sold in state of California, City of
Los Angeles, and state of Massachusetts.
* = Units are field convertible through 48 kW and are shipped for use with Natural Gas.
TRANSFER SWITCHES
STEP 1 STEP 2 STEP 3 STEP 4 STEP 5
SELECTION Transfer Switch Used With Switch Type Amp Rating Voltage Enclosure Type
CRITERIA Generator Controller Non-Service Rated = C e.g. (200 Amp = 120/240 1ø = A NEMA 3R= 3
R Controller, 200) 120/208 3ø = G
Service Entrance Rated = W
Nexus Controller = RTS 120/240 3ø = J
16 Circuit Load Shedding = J2
or Evolution Controller 277/480 3ø = K3
All 3ø = N

For Standby
Generators RTS C, W, J, N 100, 1504, 200, 3004, A, G, J, K 3
22 - 150 kW 400, 600, 800

SAMPLE R T S R 2 0 0 A 3

PRODUCT NUMBER
(Enter on Order Form)

1 = 120/240 1ø, 100 - 800 Amp NEMA 3R non-service rated only


2 = 120/240 1ø, 200 Amp service entrance rated NEMA 3R
3 = 277/480 3ø phase only for 32-160 kW
4 = 150 & 300 Amp only available in RTSW150A3 and RTSW300A3 configuration

NOTE: THERE ARE NO RETURNS, CHANGES OR CANCELLATIONS ON GENERAC COMMERCIAL SERIES ORDERS. 0182310SBY REV. B 11-2015
THIS EQUIPMENT IS BUILT-TO-ORDER ONCE PAYMENT IS RECEIVED. ©2015 Generac Power Systems, Inc.