Product Data Sheet: Wide Response Range

This document provides product information on the ZP732-2P dual sensor smoke and heat detector. It combines optical smoke sensing and thermal monitoring to provide early warning of fires. It has a wide temperature and smoke sensitivity range that meets various international standards. The detector self-tests regularly and can be set to isolate smoke sensing or use heat-only detection. It plugs into various base options and has an addressable design so the panel can monitor its exact location and status.

Uploaded by

Deepak Dubey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views2 pages

Product Data Sheet: Wide Response Range

This document provides product information on the ZP732-2P dual sensor smoke and heat detector. It combines optical smoke sensing and thermal monitoring to provide early warning of fires. It has a wide temperature and smoke sensitivity range that meets various international standards. The detector self-tests regularly and can be set to isolate smoke sensing or use heat-only detection. It plugs into various base options and has an addressable design so the panel can monitor its exact location and status.

Uploaded by

Deepak Dubey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Product Data Sheet

ZP732-2P
ZP7 Series Addressable Combination Smoke
and Heat Detector - POLAR WHITE

Wide response range


Designed to provide the earliest response to a wide
range of fire types, the ZP732-2P POLAR WHITE
dual sensor combines optical smoke sensing and
thermal monitoring to provide an accurate warning of
fire. Individual software monitoring of each element
measures actual smoke levels, in addition to
temperature rates of rise. Smoke sensing can be
isolated for areas where ambient smoke may exist at
certain times of the day, or used on a day night basis
in premises where heat only is required whilst the
building is occupied.

Temperature response meets the requirements of


EN54 Part 5 (Class A1 and A2), with smoke
sensitivity complying with EN54 Part 7 and test
procedure CEA4021. Several international approval
bodies approved this detector.

Automatic self test Standard Features


The smoke element is regularly recalibrated by the Senses both smoke and heat
E
panel for contamination and constant sensitivity. Self
test and selectable alarm verification are all provided E Heat only facility
automatically by the ZP control panel software. E Smoke element complies with EN54 Part 7 and CEA4021
E Heat element complies with EN54 Part 5 Class A1 and A2
Up to 127 sensing devices may be connected to
each of the control panel loops. All loop devices E Analogue sensing - reduces false and unwanted alarms
incorporate switch settings enabling them to be
assigned a unique address, which is polled by the E Addressable - system knows the status and location of
every detector
panel every two seconds.

Whilst effective in operation, the ZP732-2 is


unobtrusive when installed. The low profile moulding
makes the unit ideal for both commercial and
industrial interiors. A red LED indicator, situated on
the sensor moulding, flashes to indicate when the
unit is in alarm.

Locking base option


For ease of removal these detectors plug into a
range of base units by a simple twist and lock action.
A site selectable option is provided to lock the sensor
into its base. Once applied the unit can only be
removed by means of a special tool.

Space for address labels is provided on detector and


base mouldings, ensuring that units are replaced in
their correct location. The address numbers can be
identified from floor level.
ZP732-2P
ZP7 Series Addressable Combination Smoke
and Heat Detector - POLAR WHITE

Specifications
Model No ZP732-2P
Specification EN54 Pt5 (Class A1 and A2), EN54 Pt7 and CEA4021
Description Combination smoke and thermal detector
Compatibility All ZP addressable systems
Mounting Plugs into base
Wiring 2 core loop or spur
Area coverage Smoke element - 100m², subject to local codes
Thermal element - 50m², subject to local codes
Monitoring Open and short circuit fault, sensor removal and device type
Detection principle Smoke - photo electric light scatter, heat - thermistor
Addressing method 7 way DIL switches in head
Indication Alarm LED (red)
Operating voltage 19.5 to 20.5 V pulsed address line
Current 600uA quiescent, 700uA alarm
Application Indoor installation
EN60529 rating IP32
Temperature range -10ºC to +50ºC
Humidity range 20% to 95% RH (non condensing)
EMC CE compliant
Material Moulded ABS
Dimensions 106mm (Dia) x 58mm (H) (excluding base)
Height 67mm - from ceiling with ZP7-SB1 surface base
Colour Polar White
Weight 105g (excluding base)

Ordering Information
Part No. Description

ZP732-2P ZP7 Series Addressable Combination Smoke and Heat Detector - POLAR
WHITE
ZP7-IB-P ZP7 Series Addressable Detector Isolator Base - POLAR WHITE
ZP7-RB1-P ZP7 Series Addressable Detector Base, Recessed Mounting - POLAR
WHITE
ZP7-SB1-P ZP7 Series Addressable Detector Base, Surface Mounting - POLAR WHITE

As a company of innovation, UTC Fire & Security reserves the right to change product specifications without notice. For the latest product specifications, visit UTC Fire & Security
online or contact your sales representative.
IPS-ZP732-2P-2012-10-26 07:45:10 Released : 19-OCT-12