100% found this document useful (3 votes)
601 views14 pages

07 Gas Turbine Valves - 0

Uploaded by

VILAS VIJAYAN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (3 votes)
601 views14 pages

07 Gas Turbine Valves - 0

Uploaded by

VILAS VIJAYAN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

HALE HAMILTON

Excellence in Pressure & Flow Control Gas Turbine Valves


A CIRCOR International, Inc. Company

Gas Turbine Valves

DV4 Drain Valves

ASV134 Purge Valves

Back Pressure Maintaining Valve


DR5 Mk9
with pressure offset

FV2 & 3 Fuel Flow Control Valves

We design, machine, build and test all our products on one site in Hale Hamilton (Valves) Ltd
Uxbridge. If you don’t see what you want in our standard ranges, Cowley Road, Uxbridge, UB8 2AF, UK
contact us and we’ll do our best to meet your needs. Tel: 01895 236 525
www.halehamilton.com
Sep 10
HALE HAMILTON
®
Gas Turbine
Excellence in Pressure & Flow Control
Drain Valve
A CIRCOR International, Inc. Company

Description
These valves were developed for gas turbine control
applications but they may be suitable for use in similar
harsh environments.
DV4 is used to drain unburnt fuel in case of a failed
turbine start or to drain water after washing
operations. DV4 is normally open. The actuator is
pneumatic with spring return and is integrated into the
valve body.
The valves are suitable for use with combinations of
particulate fuel combustion products, diesel/paraffin
type fuel, de-mineralised water and detergent.
The base model DV4 (Mk0) is rated for 250 C. It has
no electrical or visual position indication.
DV4 Mk2, Mk3 and Mk4 have a mechanical
visual/tactile indicator and may be supplied with micro
switches to indicate fully open only; fully closed only;
fully open and fully closed or with no switches.
DV4 Mk3 has a hard (metal) seat.
DV4 Mk4 is designed to hold open at a higher
inlet/pilot pressure.

Alternative materials
Options Please contact us for details Standard Materials can be supplied
• Position switches: DV4 can be supplied with one • Body: Stainless Steel
or two internal switches to indicate: fully open, • O rings: Viton (Chemraz on DV4 Mk3 only)
fully closed or both.
• Seat: PEEK (Copper on DV4 Mk3 only)
• The switches are hermetically sealed to MIL 8805
symbol 5 • Diaphragm: Viton
• Certification: units are suitable for Category 3
ATEX service Please supply the
Ordering Information following information
when ordering
• Valve type
• Maximum working pressure
• Flow medium
• Port configuration
• Operating and storage temperature ranges
• Certification and QA requirements

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
April 10
HALE HAMILTON
®
Gas Turbine
Excellence in Pressure & Flow Control
Drain Valve
A CIRCOR International, Inc. Company

DV4 Auto Drain Valve Typical Dimensions in mm except where


shown otherwise

Specification Ø101
• Nominal Bore: 24 mm (15/16”) Pilot Indicator
• Inlet pressure: up to 31 bar (450 psi)
• Pilot pressure: 3 to 9 bar (40 to 135 psi)
• Inlet & outlet Ports: 1”NPT female
• Pilot port: 1/4” NPT
• Conduit port: 1/2” NPT (when switches are fitted)

142
• Weight: approx. 5.5kg
• Medium: combinations of particulate fuel Outlet
combustion products, diesel/paraffin fuel, de- 76AF
mineralised water and detergent.

58
• Operating temperature range: -20 to +204°C
(+250°C for DV4 (Mk0) only)

Inlet

Part Numbers and Spares Kits Please refer to Service Instruction SI946 available on request

Part Number Type number Closed Pressure Switches Seat Spares


NC53026 DV4 0.7 bar none PEEK K872
NB58841/1 DV4 Mk2 1.4 bar both PEEK K1640/1
NB58841/2 DV4 Mk2 1.4 bar closed PEEK K1640/2
NB58841/3 DV4 Mk2 1.4 bar open PEEK K1640/3
NB58841/4 DV4 Mk2 1.4 bar none PEEK K1640/4
NB60117/1 DV4 Mk3 1.4 bar both Copper K1739/1
NB60117/2 DV4 Mk3 1.4 bar closed Copper K1739/2
NB60117/3 DV4 Mk3 1.4 bar open Copper K1739/3
NB60117/4 DV4 Mk3 1.4 bar none Copper K1739/4
N102950/1 DV4 Mk4 3 bar both PEEK K2262/1
N102950/2 DV4 Mk4 3 bar closed PEEK K2262/2
N102950/3 DV4 Mk4 3 bar open PEEK K2262/3
N102950/4 DV4 Mk4 3 bar none PEEK K2262/4

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
April 10
HALE HAMILTON
®
Gas Turbine
Excellence in Pressure & Flow Control
Drain Valve
A CIRCOR International, Inc. Company

How it Works

Diaphragm

Inlet

Pilot
Pressure

Valve
Outlet
(Drain)

The valve is held open by a spring and closed when the actuator pilot port is pressurised.
The valve is designed to be operated with the pilot pressure supplied from the inlet.
When the force applied by the pilot pressure acting on the area of the diaphragm is higher than the
spring force, the valve starts to close. The pressure at which the valve is fully closed is different for each
type and is listed in the table.
For instructions on adjusting the set pressure or on servicing the valve please contact Hale Hamilton
Valves Ltd.

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
April 10
HALE HAMILTON
®
Gas Turbine
Excellence in Pressure & Flow Control
Purge Valve
A CIRCOR International, Inc. Company

Description
These valves were developed for gas turbine control
applications but they may be suitable for use in similar
harsh environments.
ASV134 is used in gas turbine systems to purge the
fuel nozzle. In the normal position (actuator un-
pressurised) the inlet is blocked and the outlet is
connected to the vent. When the actuator is
pressurised, the inlet is connected to the outlet and
the vent is blocked. All ports are momentarily
connected together during changeover.
The actuator is pneumatic with spring return and is
integrated into the valve body.

Alternative materials
Options Please contact us for details Standard Materials can be supplied
• Position switches: ASV134 can be fitted with one • Body: Stainless Steel
external switch to indicate the energised position. • O rings: Viton
This increases overall height to 208mm.
• Seats: PEEK
• Diaphragm: Viton

Please supply the


Ordering Information following information
when ordering
• Valve type
• Maximum working pressure
• Flow medium
• Port configuration
• Operating and storage temperature ranges
• Certification and QA requirements

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
April 10
HALE HAMILTON
®
Gas Turbine
Excellence in Pressure & Flow Control
Purge Valve
A CIRCOR International, Inc. Company

ASV134 Fuel Nozzle Purge Valve Typical Dimensions in mm except where


shown otherwise

Specification
• Nominal Bore: 19 mm (3/4”)
• Inlet pressure: up to 15 bar (220 psi)
• Pilot pressure: 3 to 9 bar (40 to 135 psi) Pilot
• Inlet & outlet Ports: 3/4” NPT female
• Vent port: 1/2” NPT Inlet

180
• Pilot port: 1/8” NPT
Outlet

125
• Weight: approx. 10.5kg

91
Medium: Air
• Maximum operating temperature: 232°C (when Vent

62
switch is fitted valve must not exceed 180°C and
actuator must not exceed 150°C)

34
• Maximum pilot air temperature: 38°C
• Ambient temperature range: -29 to +149°C Ø110

Part Numbers and Spares Kits Please refer to Service Instruction SI1070 available on request

Part Number Type number Switch Spares


NB54950 ASV134 no K1372
NB56102 ASV134 mk1 yes K1372

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
April 10
HALE HAMILTON
®
Gas Turbine
Excellence in Pressure & Flow Control
Purge Valve
A CIRCOR International, Inc. Company

How it Works

Diaphragm

Actuator
Actuator

Inlet
Inlet

Outlet Outlet

Vent
Vent

Valve
CLOSED OPEN

The valve is held closed by a spring and opened when the actuator port is pressurised.
In the normal position (actuator un-pressurised) the inlet is blocked and the outlet is connected to the
vent. When the actuator is pressurised, the inlet is connected to the outlet and the vent is blocked. All
ports are momentarily connected together during changeover.
The valve is pressure balanced to reduce the load on the actuator.
ASV134 Mk1 has a microswitch to indicate valve position. The switch is closed when the valve is open
(actuator pressurised).
For instructions on adjusting the set pressure or on servicing the valve please contact Hale Hamilton
Valves Ltd.

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
April 10
Back Pressure
HALE HAMILTON
®

Excellence in Pressure & Flow Control Maintaining Valve


A CIRCOR International, Inc. Company (with pressure offset)
Description
Back pressure maintaining valves (BPMV) control the
inlet pressure by venting pressure to the outlet if the
inlet pressure exceeds the set value.
DR5 Mk 9 is a dome-loaded, back pressure
maintaining valve with a spring loaded offset.
The valve remains closed until the pressure in the
upper dome exceeds the pressure in the lower dome
by more than 1bar (the spring offset). The valve then
opens and allows flow from inlet to outlet. The valve is
balanced to improve sensitivity.
DR5 Mk 9 is intended for use in maintaining back
pressure in gas turbine lubrication applications. The
spring offset ensures that some back pressure is
maintained if control pressure is lost.
This valve was developed for gas turbine control
applications but it may be suitable for use in similar
harsh environments.

See next page for specification Alternative materials can


Standard Specification of individual types Standard Materials be supplied
• Temperature range: -20 to +70°C (extended • Body: Aluminium Alloy
temperature range versions can be supplied) • Internal parts: Stainless Steel
• Valve Seat: PEEK
• O rings and Diaphragm: Viton

Please supply the following


Options Please contact us for details Ordering Information information when ordering
• Materials: suitable combinations of materials can • Maximum inlet pressure
be supplied for various applications. • Set pressure
• Flow medium
• Operating and storage temperature ranges
• Certification and QA requirements

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
Sept 10
Back Pressure
HALE HAMILTON
®

Excellence in Pressure & Flow Control Maintaining Valve


A CIRCOR International, Inc. Company (with pressure offset)
DR5 Mk9 Typical in mm except where shown otherwise
Dimensions
Specification Ø261

• Inlet pressure: 4.5bar


• Nominal set pressure: 3bar
• Offset pressure: 1bar
• Nominal bore: 63.5mm (2 1/2”)
477
• Inlet & Outlet ports: G3
• Upper dome ports: G3/4 (gauge port),
G1/4 (remote sensing port)
• Lower dome ports: G3/8 (gauge port),
G1/4 (control port)
Outlet Inlet
• Weight: approx. 27.6 kg

334

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
Sept 10
Back Pressure
HALE HAMILTON
®

Excellence in Pressure & Flow Control Maintaining Valve


A CIRCOR International, Inc. Company (with pressure offset)
How it Works

Gauge Port
Remote
Sensing Upper Dome

Lower Dome

Control
Pressure
Inlet Outlet

Valve

The lower dome of the valve contains pressurised gas at a set pressure. This acts as a spring pushing on
the diaphragm to allow the valve to close. The upper dome on the other side of the diaphragm is
connected to the remote sensing pressure. An external spring pulls the diaphragm upward and also acts
against the pressure in the upper dome. The valve is closed while the remote sensing pressure is lower
than the combination of the set pressure and the external spring.
The diaphragm moves down when the remote sensing pressure becomes higher than the sum of set
pressure and the equivalent pressure from the spring. This opens the valve and allows flow from inlet to
outlet.
To use the valve as a back pressure maintaining valve, the remote sensing port must be externally
connected to the inlet. There is no internal connection to the upper dome.
The pressure in the lower dome may be supplied from an external source of gas. In this case the inlet
pressure is maintained at 1bar higher than the control pressure.
For instructions on adjusting the set pressure or on servicing the valve please contact Hale Hamilton
Valves Ltd.

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
Sept 10
HALE HAMILTON
®
Gas Turbine
Excellence in Pressure & Flow Control
Control Valves
A CIRCOR International, Inc. Company

Description
These valves were developed for gas turbine control
applications but they may be suitable for use in similar
harsh environments.
FV2 is for the control of gaseous fuel flow. It consists
of a valve cartridge and an electrical, rotary actuator.
FV3 is for the control of liquid fuel flow. It consists of a
valve cartridge with an electrical, rotary actuator; a
relief valve and a pressure maintaining valve.
In both FV2 and FV3 the effective orifice of the valve
is controlled by the angle of the spool within the
cartridge. The spool is rotated to the required angle
by the actuator.
The valve cartridge is available in various flow ranges
and can be removed and replaced without disturbing
the valve.
The actuator is flameproof and is available in two
variants: LA16 includes a stepper motor and a
position sensor but no electronic drive system; LA17
has an electronic drive system and is slightly larger.
The actuator can be removed and replaced without
disturbing the valve.
Either actuator can be fitted on either valve.

Alternative materials
Options Please contact us for details Standard Materials can be supplied
• Actuator: available with or without electronic drive • Body: Stainless Steel
controller • O rings: Viton
• Flow cartridge: various flow rate ranges are
available Please supply the
• Relief valve: FV3 may be supplied with or without Ordering Information following information
when ordering
a relief valve • Valve type
• Certification: units are suitable for Category 2 • Flow rate range
ATEX service
• Maximum working pressure
• Relief valve setting (FV3 only)
• Pressure maintaining valve setting (FV3
only)
• Flow medium
• Port configuration
• Operating and storage temperature ranges
• Certification and QA requirements

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
Sep 10
HALE HAMILTON
®
Gas Turbine
Excellence in Pressure & Flow Control
Control Valves
A CIRCOR International, Inc. Company

FV2 Gas Fuel Valve Typical Dimensions in mm except where


shown otherwise

Specification
• Nominal Bore: 38 mm (1 1/2”)

247 (LA16)
308 (LA17)
• Inlet pressure: up to 41 bar (600 psi)
• Maximum Flow (largest orifice): 0.7 kg/s of natural
gas - pressure ratio 1.1:1
• Inlet & outlet Ports: 1 1/2” ANSI 600 flange
• Weight: approx. 28.5kg (with LA16 actuator);
29.5kg (with LA17 actuator)
• Medium: gaseous fuel
• Operating temperature range: -40 to +70°C Inlet

Outlet
Ø156

254

FV3 Liquid Fuel Valve Typical Dimensions in mm except where


shown otherwise

Specification
• Nominal Bore: 19 mm (3/4”) 293 (LA16)
• Inlet pressure: up to 120 bar (1750 psi) 354 (LA17)
• Outlet flow range: 3.6 to 58 l/min of Diesel
• Inlet, outlet & spill ports: fittings for 20mm or 3/4”
tube

Spill
• Relief valve exhaust port: G3/4
• Weight: approx. 26kg (with LA16 actuator); Relief
27kg (with LA17 actuator) Exhaust
Inlet
Outlet
• Medium: Diesel 183 97
• Operating temperature range: -40 to +80°C

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
Sep 10
HALE HAMILTON
®
Gas Turbine
Excellence in Pressure & Flow Control
Control Valves
A CIRCOR International, Inc. Company

LA16, LA17 Actuator Typical Dimensions in mm except where


shown otherwise

Specification
Ø172
LA16 LA17
Control Input Direct access 4 to 20 mA
to stepper
motor
Position Indication 4 to 20 mA 4 to 20 mA

257 (LA17)
(direct from

196 (LA16)
inductive
sensor)
Power Supply N/A 24V dc
Other functions N/A Motor lock;
fault relay; fail
closed or open
as required
Operating -40 to +90°C -40 to +80°C
temperature range
Weight approx 12.5 kg 13.5 kg
• Earth stud: M6
• Cable ports: 2 x M20 - 1.5

In addition to our standard product range, we have an extensive range of special designs and offer
a custom build service. Contact our Sales office if you don’t see what you want in our catalogue.
Hale Hamilton (Valves) Ltd
The information contained within this catalogue is for reference purposes only and is subject to
change. Cowley Road, Uxbridge, UB8 2AF, UK
When selecting a product, the total system design must be considered to ensure safe, trouble free Tel: 01895 236 525
performance. Component function, material compatibility, adequate ratings, proper installation, www.halehamilton.com
operation and maintenance are the responsibility of the system designer and user.
Sep 10

You might also like