s71500 Dq16x230vac 2a ST Manual en-US en-US
s71500 Dq16x230vac 2a ST Manual en-US en-US
Preface
___________________
Documentation guide 1
SIMATIC
___________________
Product overview 2
___________________
Wiring 3
S7-1500/ET 200MP
Digital output module
___________________
Parameters/address space 4
DQ 16x230VAC/2A ST Relay
(6ES7522-5HH00-0AB0)
___________________
Interrupts/diagnostics alarms 5
Manual
___________________
Technical specifications 6
___________________
Dimensional drawing A
___________________
Parameter data records B
07/2017
A5E34934019-AC
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Conventions
CPU: The term "CPU" is used in this manual both for the CPUs of the S7-1500 automation
system and for interface modules of the ET 200MP distributed I/O system.
STEP 7: In this documentation, "STEP 7" is used as a synonym for all versions of the
configuration and programming software "STEP 7 (TIA Portal)".
Please also observe notes marked as follows:
Note
A note contains important information on the product described in the documentation, on the
handling of the product or on the section of the documentation to which particular attention
should be paid.
Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions only form one element of such a concept.
Customer is responsible to prevent unauthorized access to its plants, systems, machines
and networks. Systems, machines and components should only be connected to the
enterprise network or the internet if and to the extent necessary and with appropriate security
measures (e.g. use of firewalls and network segmentation) in place.
Additionally, Siemens’ guidance on appropriate security measures should be taken into
account. For more information about industrial security, please visit
(http://www.siemens.com/industrialsecurity).
Siemens’ products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends to apply product updates as soon as available and to
always use the latest product versions. Use of product versions that are no longer supported,
and failure to apply latest updates may increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under (http://www.siemens.com/industrialsecurity).
Preface ................................................................................................................................................... 4
1 Documentation guide .............................................................................................................................. 7
2 Product overview .................................................................................................................................. 10
2.1 Properties ............................................................................................................................... 10
3 Wiring ................................................................................................................................................... 12
4 Parameters/address space ................................................................................................................... 15
4.1 Parameters ............................................................................................................................. 15
4.2 Declaration of parameters ...................................................................................................... 16
4.3 Address space ....................................................................................................................... 16
5 Interrupts/diagnostics alarms................................................................................................................. 22
5.1 Status and error displays ....................................................................................................... 22
5.2 Interrupts ................................................................................................................................ 24
5.3 Diagnostics alarms ................................................................................................................. 24
6 Technical specifications ........................................................................................................................ 25
A Dimensional drawing ............................................................................................................................. 31
B Parameter data records ........................................................................................................................ 33
B.1 Parameter assignment and structure of the parameter data records .................................... 33
Basic information
The System Manual and Getting Started describe in detail the configuration, installation,
wiring and commissioning of the SIMATIC S7-1500 and ET 200MP systems. The STEP 7
online help supports you in the configuration and programming.
Device information
Product manuals contain a compact description of the module-specific information, such as
properties, wiring diagrams, characteristics and technical specifications.
General information
The function manuals contain detailed descriptions on general topics regarding the SIMATIC
S7-1500 and ET 200MP systems, e.g. diagnostics, communication, motion control, Web
server, OPC UA.
You can download the documentation free of charge from the Internet
(http://w3.siemens.com/mcms/industrial-automation-systems-simatic/en/manual-
overview/Pages/Default.aspx).
Changes and supplements to the manuals are documented in a Product Information.
You can download the product information free of charge from the Internet
(https://support.industry.siemens.com/cs/us/en/view/68052815).
"mySupport"
With "mySupport", your personal workspace, you make the best out of your Industry Online
Support.
In "mySupport", you can save filters, favorites and tags, request CAx data and compile your
personal library in the Documentation area. In addition, your data is already filled out in
support requests and you can get an overview of your current requests at any time.
You must register once to use the full functionality of "mySupport".
You can find "mySupport" on the Internet (https://support.industry.siemens.com/My/ww/en).
"mySupport" - Documentation
In the Documentation area in "mySupport" you can combine entire manuals or only parts of
these to your own manual.
You can export the manual as PDF file or in a format that can be edited later.
You can find "mySupport" - Documentation on the Internet
(http://support.industry.siemens.com/My/ww/en/documentation).
Application examples
The application examples support you with various tools and examples for solving your
automation tasks. Solutions are shown in interplay with multiple components in the system -
separated from the focus on individual products.
You will find the application examples on the Internet
(https://support.industry.siemens.com/sc/ww/en/sc/2054).
See also
TIA Selection Tool (http://w3.siemens.com/mcms/topics/en/simatic/tia-selection-tool)
SAT (https://support.industry.siemens.com/cs/ww/en/view/98161300)
PRONETA (https://support.industry.siemens.com/cs/ww/en/view/67460624)
Article number
6ES7522-5HH00-0AB0
Properties
The module has the following technical properties:
● 16 digital outputs (relays)
● Supply voltage of the 24 V DC relay coils
● Rated output voltage 230 V AC (24 V DC up to 120 V DC/24 V AC up to 230 V AC)
● Rated output current 2A (per channel)
● Configurable substitute values (per channel)
● Configurable diagnostics
● Suitable for solenoid valves, DC contactors, and indicator lights
Configuration software
Function Firmware version STEP 7 GSD file in
of the module as of V13 SP1 with STEP 7 V12 or higher or
HSP 0119
STEP 7 V5.5 SP3 or higher
Firmware update V1.0.0 or higher X --- / X
Identification data I&M0 to I&M3 V1.0.0 or higher X --- / X
Parameter assignment in RUN V1.0.0 or higher X X
Module-internal Shared Output (MSO) V1.0.0 or higher X X
(PROFINET IO only) (PROFINET IO only)
Configurable submodules / submodules for V1.0.0 or higher X X
Shared Device (PROFINET IO only) (PROFINET IO only)
You can configure the module with STEP 7 and with a GSD file.
Accessories
The following accessories are supplied with the module and can also be ordered separately
as spare parts:
● Labeling strips
● U connector
● Universal front door
Other components
The following component can be ordered separately:
Front connectors, including potential jumpers and cable ties
For more information on accessories, refer to the S7-1500/ET 200MP system manual
(https://support.industry.siemens.com/cs/ww/en/view/59191792).
Note
Note that the 24 V DC supply voltage for this module must always be supplied by terminals
19/20 and 39/40. Use the supplied potential jumpers for this purpose.
Note
Ensure that the maximum current load of 8 A per potential jumper is not exceeded.
DQ 16x230VAC/2A ST parameters
When you assign the module parameters in STEP 7, you use various parameters to specify
the module properties. The table below lists the parameters that can be set. The effective
range of the configurable parameters depends on the type of configuration. The following
configurations are possible:
● Central operation with a S7-1500 CPU
● Distributed operation on PROFINET IO in an ET 200MP system
● Distributed operation on PROFIBUS DP in an ET 200MP system
For parameter assignment in the user program, the parameters are transferred to the
module with the WRREC instruction (reconfiguration in RUN) using data records; see section
Parameter assignment and structure of the parameter data records (Page 33).
No supply voltage L+
Enabling of the diagnostics at no or insufficient supply voltage L+.
Figure 4-1 Address space for configuration as 16-channel DQ 16x230VAC/2A ST QI with value
status
Figure 4-2 Address space for configuration as 2 x 8-channel DQ 16x230VAC/2A ST S QI with value
status
Note
Substitute value behavior in shared device operation with 2 x 8-channel configuration
If the system is in shared device mode and one of the associated IO controllers goes into
STOP or fails due to, for example, a communication failure, all submodules of the output
module follow the configured substitute value behavior (e.g. switch off).
This means that even when only one IO controller fails, the other IO controllers associated
with the shared device no longer control the assigned submodule of the output module.
The figure below shows the assignment of the address space for submodules 1 and 2 and
the value status.
Figure 4-3 Address space for configuration as 1 x 16-channel DQ 16x230VAC/2A ST MSO with
value status
The figure below shows the assignment of the address space for submodules 3 and 4 and
the value status.
Figure 4-4 Address space for configuration as 1 x 16-channel DQ 16x230VAC/2A ST MSO with
value status
Reference
You will find information on the module-internal shared input/shared output (MSI/MSO)
function in the function manual PROFINET with STEP 7 V13
(http://support.automation.siemens.com/WW/view/en/49948856) in the section Module-
internal shared input/shared output (MSI/MSO).
LED displays
The figure below shows the LED displays (status and error displays) of the
DQ 16x230VAC/2A ST.
PWR LED
CHx LED
5.2 Interrupts
Digital output module DQ 16x230VAC/2A ST supports diagnostic interrupts.
You can find detailed information on the event in the error organization block with the
"RALRM" instruction (read additional interrupt info) and in the STEP 7 online help.
Diagnostic interrupt
The module generates a diagnostic interrupt at the following event:
● Missing supply voltage L+
● Parameter assignment error
Diagnostics alarms
A diagnostics alarm is output for each diagnostics event and the ERROR LED flashes on the
module. The diagnostics alarms can, for example, be read from the diagnostics buffer of the
CPU. You can evaluate the error codes with the user program.
If the module is operated distributed with PROFIBUS DP in an ET 200MP system, you have
the option to read out diagnostics data with the instruction RDREC or RD_REC using data
record 0 and 1. The structure of the data records is available on the Internet in the "Manual
for interface module IM 155-5 DP ST (6ES7155-5BA00-0AB0)".
Product function
• I&M data Yes; I&M0 to I&M3
Engineering with
• STEP 7 TIA Portal configurable/integrated V13 SP1 / -
as of version
• PWM No
• Oversampling No
• MSO Yes
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Input current
Current consumption, max. 150 mA
Output voltage
Rated value (AC) 230 V; 24 V DC to 120 V DC / 24 V AC to 230 V
AC
• for uprating No
Isochronous mode
Isochronous operation (application synchro- No
nized up to terminal)
Interrupts/diagnostics/status information
Diagnostics function Yes
Substitute values connectable Yes
Alarms
• Diagnostic alarm Yes
Diagnostic messages
• Monitoring the supply voltage Yes
• Wire-break No
• Short-circuit No
Potential separation
Potential separation channels
• between the channels No
Decentralized operation
Prioritized startup Yes
Dimensions
Width 35 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 350 g
Table 6- 1 Switching capacity and service life of relay contacts for resistive load
Table 6- 2 Switching capacity and lifetime of the relay contacts for inductive load
Figure A-2 Dimension drawing of the DQ 16x230VAC/2A ST module, side view with open front
cover
For the configuration as a 2 x 8-channel module, the module has 2 submodules with eight
channels each. The parameters for the channels are located in data records 64 to 71 and
are assigned as follows:
● Data records 64 to 71 for channels 0 to 7 (submodule 1)
● Data records 64 to 71 for channels 8 to 15 (submodule 2)