Huawei Smart Solar Solutions
Huawei Smart Solar Solutions
Huawei is a leading global provider of information and communications technology (ICT) infrastructure and smart devices.
With integrated solutions across four key domains – telecom networks, IT, smart devices, and cloud services – we are commit-
ted to bringing digital to every person, home and organization for a fully connected, intelligent world. Huawei's end-to-end
portfolio of products, solutions and services are both competitive and secure. Through open collaboration with ecosystem
partners, we create lasting value for our customers, working to empower people, enrich home life, and inspire innovation in
organizations of all shapes and sizes. At Huawei, innovation focuses on customer needs. We invest heavily in basic research,
74 61 14
No.1 118GW+
In global shipment 2015-2019 Accumulated global shipment at the end of 2019
S O L A R .H U A WE I . C O M / EU /
Residential PV Solution
WLAN/Ethernet/4G/3G/2G
FusionSolar
Management system
No Optimizer
RS485
Smart Energy Center Smart Power Sensor
Full Optimizer
Battery
Module Auto-Mapping
Pinpoint Arc Fault Positioning 2x POWER Battery Ready with
within 5 sec
More Energy
SOLAR.HUAWEI.COM/EU/
Smart Energy Center
2x
88% AC SPD
5% 10% 20% 30% 50% 75% 100%
SOLAR.HUAWEI.COM/EU/
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1
Technical Specification
SUN2000 SUN2000 SUN2000 SUN2000 SUN2000 SUN2000 SUN2000
Technical Specification -2KTL-L1 -3KTL-L1 -3.68KTL-L1 -4KTL-L1 -4.6KTL-L1 -5KTL-L1 -6KTL-L11
Efficiency
Max. efficiency 98.2 % 98.3 % 98.4 % 98.4 % 98.4 % 98.4 % 98.4 %
European weighted efficiency 96.7 % 97.3 % 97.3 % 97.5 % 97.7 % 97.8 % 97.8 %
Input (PV)
Recommended max. PV power 2 3,000 Wp 4,500 Wp 5,520 Wp 6,000 Wp 6,900 Wp 7,500 Wp 9,000 Wp
Max. input voltage 600 V 3
Start-up voltage 100 V
MPPT operating voltage range 90 V – 560 V 3
Rated input voltage 360 V
Max. input current per MPPT 12.5 A
Max. short-circuit current 18 A
Number of MPP trackers 2
Max. number of inputs 2
Output
Grid connection Single phase
Rated output power 2,000 W 3,000 W 3,680 W 4,000 W 4,600 W 5,000 W 5 6,000 W
Max. apparent power 2,200 VA 3,300 VA 3,680 VA 4,400 VA 5,000 VA 6 5,500 VA 7 6,000 VA
Rated output voltage 220 Vac / 230 Vac / 240 Vac
Rated AC grid frequency 50 Hz / 60 Hz
Max. output current 10 A 15 A 16 A 20 A 23 A 8 25 A 8 27.3 A
Adjustable power factor 0.8 leading ... 0.8 lagging
Max. total harmonic distortion ≤3%
Backup power output Yes (via Backup Box-5000 1)
General Data
Operating temperature range -25 ~ +60 °C (Derating above 45°C @ Rated output power)
Relative operating humidity 0 %RH~100 %RH
Operating altitude 0 ~ 4,000 m (Derating above 2,000 m)
Cooling Natural convection
Display LED indicators; integrated WLAN + FusionSolar APP
RS485, WLAN via inverter built-in WLAN module
Communication
Ethernet via Smart Dongle-WLAN-FE (Optional); 4G / 3G / 2G via Smart Dongle-4G (Optional)
Weight (incl. mounting bracket) 12.0 kg (26.5 lb)
Dimension (incl. mounting bracket) 365mm * 365mm * 156 mm (14.4 x 14.4 x 6.1 inch)
Degree of protection IP65
Optimizer Compatibility
DC MBUS compatible optimizer SUN2000-450W-P
Input
Rated Input DC Power 1 450 W
Absolute maximum input voltage 80 V
MPPT operating voltage range 8 - 80 V
Maximum Short Circuit Current (Isc) 13 A
Max. efficiency 99.5 %
Weighted efficiency 99.0 %
Overvoltage category II
Output
Max. output voltage 80 V
Max. output current 15 A
Output bypass 2 Yes
Shutdown output voltage per optimizer 3 0V
Shutdown output impedance per optimizer 1k ohm ± 10 %
Standard Compliance
Safety IEC62109-1 (class II safety)
RoHS Yes
General Data
Dimension (W x H x D) 71 x 138 x 25 mm (2.8 x 5.4 x 1.0 inch)
Weight (including cables) 0.55 kg (1.2 lb.)
Installation part (optional) Grounding Plate, Grounding Lug, PV Module Frame Plate
Input connector MC4
Output connector MC4
Output wire length 1.2 m (3.9 ft.) 4
Operating temperature / humidity range -40 ℃~85 ℃ 5 / 0 %RH~100 %RH
Degree of protection IP68
Compatible product SUN2000-2/3/3.68/4/4.6/5/6KTL-L1, SUN2000-3/4/5/6/8/10KTL-M1, SUN2000-12/15/17/20KTL-M2
Higher Revenue Simple & Easy Battery Ready Safe & Reliable
Max. efficiency 98.6% 17 kg Plug & Play battery interface Arc fault protection
PV1+
98%
DC/AC Output
PV1- EMI Converter Isolation Relay
Filter
96% PV2-
L1
PV2+
94% Output EMI L2
Filter Filter
L3
92% SPD
N
BAT+ PE
90% BAT-
SPD
0% 20% 40% 60% 80% 100%
470 V 600 V 850 V
Load [%] SUN2000-3/4/5/6/8/10KTL-M0
SOLAR.HUAWEI.COM/EU/
SUN2000-3/4/5/6/8/10KTL-M0
Technical Specification
Efficiency
Max. efficiency 98.2% 98.3% 98.4% 98.6% 98.6% 98.6%
European weighted efficiency 96.7% 97.1% 97.5% 97.7% 98.0% 98.1%
Input
Recommended max. PV power 6,000 Wp 8,000 Wp 10,000 Wp 12,000 Wp 14,880 Wp 14,880 Wp
Max. input voltage 1 1,100 V
Operating voltage range 2 140 V ~ 980 V
Start-up voltage 200 V
Full power MPPT voltage range 140 V ~ 850 V 190 V ~ 850 V 240 V ~ 850 V 285 V ~ 850 V 380 V ~ 850 V 470 V ~ 850 V
Rated input voltage 600 V
Max. input current per MPPT 11 A
Max. short-circuit current 15 A
Number of MPP trackers 2
Max. number of inputs 2
Output
Grid connection Three-phase
Rated output power 3,000 W 4,000 W 5,000 W 6,000 W 8,000 W 10,000 W
Max. apparent power 3,300 VA 4,400 VA 5,500 VA 6,600 VA 8,800 VA 11,000 VA 3
Rated output voltage 220 Vac / 380 Vac, 230 Vac / 400 Vac, 3W / N+PE
Rated AC grid frequency 50 Hz / 60 Hz
Max. output current 5.1 A 6.8 A 8.5 A 10.1 A 13.5 A 16.9 A
Adjustable power factor 0.8 leading ... 0.8 lagging
Max. total harmonic distortion ≤3%
General Data
Operating temperature range -25 ~ + 60 °C (-13 °F ~ 140 °F) (Derating above 45 °C @ Rated output power)
Relative operating humidity 0 %RH~100 %RH
Operating altitude 0 - 4,000 m (13,123 ft.) (Derating above 3000 m)
Cooling Natural convection
Display LED Indicators; Integrated WLAN + FusionSolar App
RS485;
Communication
RS485; WLAN/Ethernet via Smart Dongle-WLAN-FE; 4G / 3G / 2G via Smart Dongle-4G (Optional)
Weight (incl. mounting bracket) 17 kg (37.5 lb)
Dimension (incl. mounting bracket) 525 x 470 x 166 mm (20.7 x 18.5 x 6.5 inch)
Degree of protection IP65
Nighttime Power Consumption < 5.5 W
General Data
Max. Devices Supported 10
Max. Inverters Supported 10
Connection interface USB
Ethernet Interface 10/100M Ethernet
Installation Plug-and-play
Indicator LED Indicator
Dimensions (W * H * D) 146 x 48 x 33 mm (5.1 x 1.9 x 1.3 inch)
Weight 90 g (0.2 lb.)
Degree of protection IP65
Power consumption (typical) 2.5 W
Operation Mode STA
Encryption Mechanism:WPA/WPA2
Encryption Algorithm
Encryption:TKIP/CCMP/AES
Wireless Parameter
Supported standards & frequencies 802.11b/g/n(2.412G—2.484G)
Environment
Operating temperature range -30 ℃ to +65 ℃ (-22 ℉ to 149 ℉)
Relative humidity range 5 - 95% RH
Storage temperature range -40℃ to +70℃ (-40 ℉ to 158 ℉)
Max. operating altitude 4,000 m (13,123 ft.)
Inverter Compatibility
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1
Inverter model SUN2000-3/4/5/6/8/10KTL-M0
SUN2000-12/15/17/20KTL-M0
*1: 3rd-party management system shall match the communication protocol with Huawei Smart Dongle.
General Data
Max. Devices Supported 10
Max. Inverters Supported 10
Connection interface USB
Installation Plug-and-play
Indicator LED Indicator
Dimensions (W * H * D) 130 x 48 x 33 mm (5.1 x 1.9 x 1.3 inch)
Weight 90 g (0.2 lb.)
Degree of protection IP65
Power consumption (typical) 3.5 W
Wireless Parameter
Sim card type mini-sim (15 mm*25 mm)
Environment
Operating temperature range -30 ℃ to +65 ℃ (-22 ℉ to 149 ℉)
Relative humidity range 5 - 95% RH
Storage temperature range -40 ℃ to +70 ℃ (-40 ℉ to 158 ℉)
Max. operating altitude 4,000 m (13,123 ft.)
Inverter Compatibility
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1
SUN2000-3/4/5/6/8/10KTL-M0
Inverter model SUN2000-12/15/17/20KTL-M0
SUN2000-60KTL-M0
SUN2000-100KTL-M1
1: To ensure stable data transmission, Huawei suggests 4G dongle to be installed in areas with stable mobile signal (2G signal ≥4 bars, 3G/4G signal ≥3 bars).
2: 3rd-party management system shall match the communication protocol with Huawei Smart Dongle.
3. For recommended carriers list and details on supported frequencies, please contact local distributors.
General Data
100 x 36 x 65.5 mm 100 x 72 x 65.5 mm
Dimension (H x W x D)
(3.9 x 1.4 x 2.6 inch) (3.9 x 2.8 x 2.6 inch)
Mounting type DIN35 Rail
Weight (including cables) 1.2 kg (2.6 lb) 1.5 kg (3.3 lb)
Power Supply
Power grid type 1P2W 3P4W
Input voltage (phase voltage) 176 Vac ~ 288 Vac
Power consumption ≤ 0.8 W ≤1W
Measurement Range
Line voltage / 304 Vac ~ 499 Vac
Phase voltage 176 Vac ~ 288 Vac
Current 0 ~ 100 A 0 ~ 250 A
Measurement Accuracy
Voltage ±0.5 %
Current / Power / Energy ±1 %
Frequency ±0.01 Hz
Communication
Interface RS485
Baud rate 9,600 bps
Communication protocol Modbus-RTU
Environment
Operating temperature range -25 ℃ ~ 60 ℃
Storage temperature range -40 ℃ ~ 70 ℃
Operating humidity 5 %RH ~ 95 %RH (non-condensing)
Others
RS485 Cable (10 m / 33 ft.)
1 CT 100 A/40 mA (5 m/16.4 ft.) 3 CT 250 A/50 mA (5 m/16.4 ft.)
Accessories
SmartLogger
4G/3G/2G
RS485
Weather Station FusionSolar Smart PV
RS485 Management system
PV Module Smart PV Inverter
AI Powered Active Arcing 2 Strings per MPPT, More Energy No Fuse & Other Quick-wear Parts,
Protection Yields Inverter Touch Free
SOLAR.HUAWEI.COM/EU/
Smart String Inverter
PV1+
98% PV1- PVA
PV2+
DC/AC Output
97% PV2-
PVAB- EMI Converter Isolation Relay
Filter
96%
PV3+
L1
PV3- PVB
Output EMI L2
95% PV4+
Filter Filter
PV4-
L3
SPD
94% N
PE
93% SPD
0.00% 20.00% 40.00% 60.00% 80.00% 100.00%
480V 600V 850V
SOLAR.HUAWEI.COM/EU/
SUN2000-12/15/17/20KTL-M0
Technical Specification
Efficiency
Max. efficiency 98.50% 98.65% 98.65% 98.65%
European weighted efficiency 98.00% 98.30% 98.30% 98.30%
Input
Recommended max. PV power 24,000 Wp 29,760 Wp 29,760 Wp 29,760 Wp
Max. input voltage 1 1,080 V
Operating voltage range 2 160 V ~ 950 V
Start voltage 200 V
Full power MPPT voltage range 380 Vdc~850 Vdc 380 Vdc~850 Vdc 400 Vdc~850 Vdc 480 Vdc~850 Vdc
Rated input voltage 600 V
Max. input current per MPPT 22 A
Max. short-circuit current 30 A
Number of MPP trackers 2
Max. number of inputs 4
Output
Grid connection Three phase
Rated output power 12,000 W 15,000 W 17,000 W 20,000 W
Max. apparent power 13,200 VA 16,500 VA 18,700 VA 22,000 VA
Rated output voltage 220 Vac / 380 Vac, 230 Vac / 400 Vac, 3W + N + PE
Rated AC grid frequency 50 Hz / 60 Hz
Max. output current 20 A 25.2 A 28.5 A 33.5 A
Adjustable power factor 0.8 leading ... 0.8 lagging
Max. total harmonic distortion ≤3%
General Data
Operation temperature range -25 ~ + 60 °C (-13 °F ~ 140 °F) (Derating above 45 °C @ Rated output power)
Relative humidity 0 % RH ~ 100% RH
Max. operating altitude 0 - 4,000 m (13,123 ft.) (Derating above 2000 m)
Cooling Natural Convection
Display LED indicators; integrated WLAN + FusionSolar APP
RS485;
Communication WLAN/Ethernet via Smart Dongle-WLAN-FE (Optional)
4G / 3G / 2G via Smart Dongle-4G (Optional)
Weight (with mounting plate) 25 kg
Dimensions (W x H x D)
525 x 470 x 262 mm (20.7 x 18.5 x 10.3 inch)
(incl. mounting plate)
Degree of protection IP65
Nighttime Power Consumption < 5.5 W
SOLAR.HUAWEI.COM/EU/
SUN2000-33KTL-A
Technical Specification
Efficiency
Max. Efficiency 98.6%
European Efficiency 98.4%
Input
Max. Input Voltage 1 1,100 V
Max. Current per MPPT 22 A
Max. Short Circuit Current per MPPT 30 A
Start Voltage 250 V
MPPT Operating Voltage Range 2 200 V ~ 1,000 V
Rated Input Voltage 620 V
Number of MPP trackers 4
Max. number of inputs 8
Output
Rated AC Active Power 30,000 W
Max. AC Apparent Power 33,000 VA
Max. AC Active Power 30,000 W 3
Rated Output Voltage 230 V / 400 V, 3W + N + PE;
Rated AC Grid Frequency 50 Hz / 60 Hz
Rated Output Current 43.3 A
Max. Output Current 48 A
Adjustable Power Factor Range 0.8 leading... 0.8 lagging
Max. Total Harmonic Distortion <3%
Protection
Input-side Disconnection Device Yes
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes
Communication
Display LED indicators; WLAN adaptor + FusionSolar APP
RS485 Yes
USB Yes
Monitoring BUS (MBUS) Yes (isolation transformer required)
General Data
Dimensions (W x H x D) 930 x 550 x 283 mm (36.6 x 21.7 x 11.1 inch)
Weight (with mounting plate) 62 kg (136.7 lb.)
Operating Temperature Range -25 °C ~ 60 °C (-13°F ~ 140°F)
Cooling Method Natural Convection
Max. Operating Altitude 4,000 m (13,123 ft.)
Relative Humidity 0 ~ 100%
DC Connector Amphenol Helios H4
AC Connector Waterproof PG Terminal + OT Connector
Protection Degree IP65
Topology Transformerless
Nighttime Power Consumption < 2.5 W
+ MPPT3
92% -
-
+
90% + MPPT4
0% 20% 40% 60% 80% 100% -
-
SPD
580V 720V 850V Current DC
Sensor Switch 2
SOLAR.HUAWEI.COM/EU/
SUN2000-36KTL
Technical Specification
Efficiency
Max. Efficiency 98.8% @480 V; 98.6% @380 V / 400 V
European Efficiency 98.6% @480 V; 98.4% @380 V / 400 V
Input
Max. Input Voltage 1 1,100 V
Max. Current per MPPT 22 A
Max. Short Circuit Current per MPPT 30 A
Start Voltage 250 V
MPPT Operating Voltage Range 2 200 V ~ 1,000 V
Rated Input Voltage 620 V @380 Vac / 400 Vac; 720 V @480 Vac
Number of MPP trackers 4
Max. number of inputs 8
Output
Rated AC Active Power 36,000 W
Max. AC Apparent Power 40,000 VA
Max. AC Active Power (cosφ=1) Default 40,000 W; 36,000 W optional in settings
220 V / 380 V, 230 V / 400 V, default 3W + N + PE; 3W + PE optional in settings
Rated Output Voltage
277 V / 480 V, 3W + PE
Rated AC Grid Frequency 50 Hz / 60 Hz
Rated Output Current 54.6 A @380 V, 52.2 A @400 V, 43.4 A @480 V
Max. Output Current 60.8 A @380 V, 57.8 A @400 V, 48.2 A @480 V
Adjustable Power Factor Range 0.8 leading... 0.8 lagging
Max. Total Harmonic Distortion <3%
Protection
Input-side Disconnection Device Yes
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes
Communication
Display LED indicators; WLAN adaptor + FusionSolar APP
RS485 Yes
USB Yes
Monitoring BUS (MBUS) Yes (isolation transformer required)
General Data
Dimensions (W x H x D) 930 x 550 x 283 mm (36.6 x 21.7 x 11.1 inch)
Weight (with mounting plate) 62 kg (136.7 lb.)
Operating Temperature Range -25°C ~ 60°C (-13°F ~ 140°F)
Cooling Method Natural Convection
Max. Operating Altitude 4,000 m (13,123 ft.)
Relative Humidity 0 ~ 100%
DC Connector Amphenol Helios H4
AC Connector Waterproof PG Terminal + OT Connector
Protection Degree IP65
Topology Transformerless
Nighttime Power Consumption < 2.5 W
*1 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.
*2 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.
100%
-
L1
+
Output EMI L2
MPPT2
99%
+
Filter Filter L3
-
N
98% -
DC/AC Output
+ Inverter Isolation SPD PE
97% + MPPT3 Relay
- EMI
96% -
DC SPD Filter
Switch 1
95%
+
94% + MPPT4
-
93% -
+
92% + MPPT5
91%
-
-
90% +
+ MPPT6
0% 20% 40% 60% 80% 100% -
-
SPD
520V 600V 800V Current DC
Sensor Switch 2
SOLAR.HUAWEI.COM/EU/
SUN2000-60KTL-M0
Technical Specification
Efficiency
Max. efficiency 98.9% @480 V; 98.7% @380 V / 400 V
European efficiency 98.7% @480 V; 98.5% @380 V / 400 V
Input
Max. Input Voltage 1 1,100 V
Max. Current per MPPT 22 A
Max. Short Circuit Current per MPPT 30 A
Start Voltage 200 V
MPPT Operating Voltage Range 2 200 V ~ 1,000 V
Rated Input Voltage 600 V @380 Vac / 400 Vac; 720 V @480 Vac
Number of MPP trackers 6
Max. number of inputs 12
Output
Rated AC Active Power 60,000 W
Max. AC Apparent Power 66,000 VA
Max. AC Active Power (cosφ=1) 66,000 W
Rated Output Voltage 220 V / 380 V, 230 V / 400 V, default 3W + N + PE; 3W + PE optional in settings; 277 V / 480 V, 3W + PE
Rated AC Grid Frequency 50 Hz / 60 Hz
Rated Output Current 91.2 A @380 V, 86.7 A @400 V, 72.2 A @480 V
Max. Output Current 100 A @380 V, 95.3 A @400 V, 79.4 A @480 V
Adjustable Power Factor Range 0.8 leading... 0.8 lagging
Max. Total Harmonic Distortion <3%
Protection
Input-side Disconnection Device Yes
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes
Communication
Display LED indicators; WLAN adaptor + FusionSolar APP
RS485 Yes
USB Yes
Monitoring BUS (MBUS) Yes (isolation transformer required)
General Data
Dimensions (W x H x D) 1,075 x 555 x 300 mm (42.3 x 21.9 x 11.8 inch)
Weight (with mounting plate) 74 kg (163.1 lb.)
Operating Temperature Range -25°C ~ 60°C (-13°F ~ 140°F)
Cooling Method Natural Convection
Max. Operating Altitude 4,000 m (13,123 ft.)
Relative Humidity 0 ~ 100%
DC Connector Amphenol Helios H4
AC Connector Waterproof PG Terminal + Terminal Clamp
Protection Degree IP65
Topology Transformerless
Nighttime Power Consumption <2W
96%
-
+
+ MPPT5
95% -
-
EMI
+
Filter
94% +
-
MPPT6
-
DC SPD
93% Switch 2
+
+ MPPT7
92% -
-
+
91% + MPPT8
-
90%
-
+
MPPT9
0% 20% 40% 60% 80% 100%
+
-
+
+
MPPT10
-
- SPD
Load [%] Current DC
Sensor Switch 3
SOLAR.HUAWEI.COM/EU/
SUN2000-100KTL-M1
Technical Specification
Efficiency
Max. efficiency 98.8% @480 V, 98.6% @380 V / 400 V
European efficiency 98.6% @480 V, 98.4% @380 V / 400 V
Input
Max. Input Voltage 1 1,100 V
Max. Current per MPPT 26 A
Max. Short Circuit Current per MPPT 40 A
Start Voltage 200 V
MPPT Operating Voltage Range 2 200 V ~ 1,000 V
Nominal Input Voltage 720 V @480 Vac, 600 V @400 Vac, 570 V @380 Vac
Number of MPP trackers 10
Max. number of inputs 20
Output
Nominal AC Active Power 100,000 W
Max. AC Apparent Power 110,000 VA
Max. AC Active Power (cosφ=1) 110,000 W
Nominal Output Voltage 480 V/ 400 V/ 380 V, 3W+(N)+PE
Rated AC Grid Frequency 50 Hz / 60 Hz
Nominal Output Current 120.3 A @480 V, 144.4 A @400 V, 152.0 A @380 V
Max. Output Current 133.7 A @480 V, 160.4 A @400 V, 168.8 A @380 V
Adjustable Power Factor Range 0.8 leading... 0.8 lagging
Max. Total Harmonic Distortion <3%
Protection
Input-side Disconnection Device Yes
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes
Communication
Display LED indicators; WLAN adaptor + FusionSolar APP
RS485 Yes
USB Yes
Monitoring BUS (MBUS) Yes (isolation transformer required)
General Data
Dimensions (W x H x D) 1,035 x 700 x 365 mm
Weight (with mounting plate) 90 kg
Operating Temperature Range -25°C ~ 60°C
Cooling Method Smart Air Cooling
Max. Operating Altitude without Derating 4,000 m
Relative Humidity 0 ~ 100%
DC Connector Staubli MC4
AC Connector Waterproof Connector + OT/DT Terminal
Protection Degree IP66
Topology Transformerless
Nighttime Power Consumption < 3.5 W
Device Management
Max. Number of Connected Devices 80
Communication Interface
WAN WAN x 1, 10 / 100 / 1000 Mbps
LAN LAN x 1, 10 / 100 / 1000 Mbps
RS485 COM x 3, 1200 / 2400 / 4800 / 9600 / 19200 / 115200 bps, 1000 m
MBUS MBUS x 1, 115.2 kbps, Compatible with PLC No MBUS Communication Interface
LTE(FDD):B1,B2,B3,B4,B5,B7,B8,B20
2G / 3G / 4G 1 DC-HSPA+/HSPA+/HSPA/UMTS: 850/900/1900/2100 MHz
GSM/GPRS/EDGE: 850/900/1800/1900 MHz 2
Digital / Analog Input / Output DI x 4, DO x 2, AI x 4
Active DO 12V, 100mA (connection with relay, sensor)
Communication Protocol
Ethernet Modbus-TCP, IEC 60870-5-104
RS485 Modbus-RTU, IEC 60870-5-103 (standard), DL / T645
Interaction
LED LED Indicator x 3 – RUN, ALM, 4G
WEB Embedded Web
USB USB 2.0 x 1
APP Communication by WLAN for Commissioning
Environment
Operating Temperature Range -40°C ~ 60°C (-40°F ~ 140°F)
Storage Temperature -40°C ~ 70°C (-40°F ~ 158°F)
Relative Humidity (Non-condensing) 5% ~ 95%
Max. Operating Altitude 4,000 m (13,123 ft.)
Electrical
AC Power Supply 100 V~240 V, 50 Hz / 60 Hz
DC Power Supply 12 V / 24 V
Power Consumption Typical 8 W, Max. 15 W
Mechanical
Dimensions (W x H x D) 225 x 160 x 44 mm (8.9 x 6.3 x 1.7 inch, without mounting ears and antenna)
Weight 2 kg (4.4 lb.)
Protection Degree IP20
Installation Options Wall Mounting, DIN Rail Mounting, Tabletop Mounting
*1: When putting inside metal box, extended antenna will be needed.
*2: For recommended carriers list and details on supported frequencies, please contact local distributors.
Data Collection
Dashboard
Energy Flow
Basic
Energy Generation & Consumption
Feature
Device Management
Report Management
Alarm Management
System Configuration
Intelligent O&M
Mobile O&M
Advanced
Feature
Proactive Diagnosis
Basic Optional
Smart I-V Curve Diagnosis is able to carry out online I-V curve analysis on entire strings with
advanced diagnosis algorithm. The scanning would help to find out and identify the strings
with low performance or faults, which would help to achieve proactive maintenance, higher
O&M efficiency and lower operation cost.
Smart
Support plant-level, array-level and inverter-level analysis and
diagnosis
Automatically identify different failure types and provide recovery
suggestion
Efficient
One-click scanning without onsite experts or equipment
Online I-V curve scanning on entire strings of 5 MW plant within 5min
Automatic report generation of 5 MW plant within 15min
Network
Ethernet
FusionSolar
SmartLogger
Smart PV Management system
WLAN 3G/4G RS485
Weather Station
(optional)
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1*, SUN2000-3/4/5/6/8/10KTL-M0,
Smart PV Inverter SUN2000-12/15/17/20KTL-M0, SUN2000-33KTL-A/36KTL, SUN2000-
60KTL-M0, SUN2000-100KTL-M1
Certification TUV
* I-V curve diagnosis is not supported when inverter is connected with power optimizer.
6
5
4
3 Normal Curve
2
1 Abnormal Curve with shading on Modules
0
0 100 200 300 400 500 600 700 800
Voltage [V]
9
8
Current [A]
7
6
5
4
3 Normal Curve
2
Abnormal Curve with String Current Mismatch
1
0
0 100 200 300 400 500 600 700 800
Voltage [V]
4kW
设备图 Residential PV System in Waregem, Belgium
COD
May, 2018
System Configuration
• 18 × 295Wp modules
• 6 × 375W optimizers
• SUN2000L-4KTL, WLAN
• Smart PV safety box
8kW
设备图 Residential energy system in Sydney, Australia COD
Dec, 2017
System Configuration
• 36 × 270Wp modules
• 24 × 375W optimizers
• SUN2000L-3KTL & -5KTL
• LG Chem RESU10H Type R
SOLAR.HUAWEI.COM/EU/
Case Reference
15kW
设备图 Residential PV system in NSW, Australia
COD
Feb, 2019
System Configuration
• 37 × 310Wp Longi modules, 12 x existed old modules
• 3 x SUN2000L-5KTL
• WLAN communication
33kW
Residential PV system in Hanadacho Chokushi, Japan
COD
April, 2018
System Configuration
• 120 × 275Wp modules
• 8 × SUN2000L-4.125KTL-JP
• SmartACBox12in1
SOLAR.HUAWEI.COM/EU/
Case Reference
1MWp
Distributed PV System in Kuala Lumpur,Malaysia
COD
Mar 2016
System Configuration
• SUN2000-36KTL
2.8MWp
设备图 Distributed PV system at Singapore Changi Airport
COD
System Configuration Dec, 2016
• SUN2000-36KTL
SOLAR.HUAWEI.COM/EU/
Case Reference
85.8KWp
Distributed PV System in Brazil
COD
System Configuration Feb, 2018
• 264 x 325Wp modules
• 2 x SUN2000-36KTL
260KWp
Distributed PV System in Brazil
COD
Mar, 2018
System Configuration
• 788 x 330Wp modules
• 4 x SUN2000-36KTL
SOLAR.HUAWEI.COM/EU/
Case Reference
616KWp
Distributed PV System in Multan, Pakistan
COD
Oct, 2019
System Configuration
• SUN2000-36 KTL
• SUN2000-60 KTL
1.25MWp
Distributed PV System in South Africa
COD
System Configuration Sep, 2019
• SUN2000-60KTL
SOLAR.HUAWEI.COM/EU/