100% found this document useful (1 vote)
546 views32 pages

Huawei Smart Solar Solutions

Huawei is a leading global provider of information and communications technology infrastructure and smart devices. They offer integrated solutions across telecom networks, IT, smart devices, and cloud services to connect people and organizations digitally. Huawei focuses on innovation that meets customer needs and invests heavily in research and development to drive technological advancement.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
546 views32 pages

Huawei Smart Solar Solutions

Huawei is a leading global provider of information and communications technology infrastructure and smart devices. They offer integrated solutions across telecom networks, IT, smart devices, and cloud services to connect people and organizations digitally. Huawei focuses on innovation that meets customer needs and invests heavily in research and development to drive technological advancement.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

About Huawei

Huawei is a leading global provider of information and communications technology (ICT) infrastructure and smart devices.
With integrated solutions across four key domains – telecom networks, IT, smart devices, and cloud services – we are commit-

ted to bringing digital to every person, home and organization for a fully connected, intelligent world. Huawei's end-to-end

portfolio of products, solutions and services are both competitive and secure. Through open collaboration with ecosystem

partners, we create lasting value for our customers, working to empower people, enrich home life, and inspire innovation in

organizations of all shapes and sizes. At Huawei, innovation focuses on customer needs. We invest heavily in basic research,

concentrating on technological breakthroughs that drive the world forward.

Employees R&D Personnel Countries

194,000 + 96,000+ 170+


Interbrand's Top 100 Fortune Global 500 Research institutes
Best Global Brands /labs/centers

74 61 14

No.1 118GW+
In global shipment 2015-2019 Accumulated global shipment at the end of 2019

S O L A R .H U A WE I . C O M / EU /
Residential PV Solution

WLAN/Ethernet/4G/3G/2G

FusionSolar
Management system
No Optimizer

RS485
Smart Energy Center Smart Power Sensor

Full Optimizer

Battery

Active Safety Higher Yields Better Experience

AI Powered Active Arcing Up to 30% More Energy by One-Fits-All Optimizer,


Protection Optimizers Easier Business

Module Auto-Mapping
Pinpoint Arc Fault Positioning 2x POWER Battery Ready with
within 5 sec
More Energy

SOLAR.HUAWEI.COM/EU/
Smart Energy Center

2x

Active Safety Higher Yields 2x POWER Battery Ready


AI Powered Up to 30% More 5KW AC Output plus
Active Arcing Protection Energy with Optimizer 5KW Battery Charge

Efficiency Curve Circuit Diagram


100%
DC Input
Switch EMI Filter
98%
+
96% PV1 DC/AC Output Output
- Converter Isolation Relay EMI Filter
94% +
PV2 L
92% - N
- PE
90% Battery
+
DC SPD

88% AC SPD
5% 10% 20% 30% 50% 75% 100%

260V 360V 480V

Load [%] SUN2000-2/3/3.68/4/4.6/5/6KTL-L1

SOLAR.HUAWEI.COM/EU/
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1
Technical Specification
SUN2000 SUN2000 SUN2000 SUN2000 SUN2000 SUN2000 SUN2000
Technical Specification -2KTL-L1 -3KTL-L1 -3.68KTL-L1 -4KTL-L1 -4.6KTL-L1 -5KTL-L1 -6KTL-L11

Efficiency
Max. efficiency 98.2 % 98.3 % 98.4 % 98.4 % 98.4 % 98.4 % 98.4 %
European weighted efficiency 96.7 % 97.3 % 97.3 % 97.5 % 97.7 % 97.8 % 97.8 %

Input (PV)
Recommended max. PV power 2 3,000 Wp 4,500 Wp 5,520 Wp 6,000 Wp 6,900 Wp 7,500 Wp 9,000 Wp
Max. input voltage 600 V 3
Start-up voltage 100 V
MPPT operating voltage range 90 V – 560 V 3
Rated input voltage 360 V
Max. input current per MPPT 12.5 A
Max. short-circuit current 18 A
Number of MPP trackers 2
Max. number of inputs 2

Input (DC Battery)


Compatible Battery LG Chem RESU 7H_R / 10H_R
Operating voltage range 350 ~ 450 Vdc
Max operating current 10 A @7H_R / 15 A @10H_R
Max charge power 3,500 W @7H_R / 5,000 W @10H_R
Max discharge Power @7H_R 2,200 W 3,300 W 3,500 W 3,500 W 3,500 W 3,500 W 3,500 W
Max discharge Power @10H_R 2,200 W 3,300 W 3,680 W 4,400 W 4,600 W 5,000 W 5,000 W

Compatible Battery HUAWEI Smart ESS Battery 5kWh – 30kWh 1


Operating voltage range 350 ~ 560 Vdc
Max operating current 15 A
Max charge Power 5,000 W 4
Max discharge Power 2,200 W 3,300 W 3,680 W 4,400 W 4,600 W 5,000 W 5,000 W

Output
Grid connection Single phase
Rated output power 2,000 W 3,000 W 3,680 W 4,000 W 4,600 W 5,000 W 5 6,000 W
Max. apparent power 2,200 VA 3,300 VA 3,680 VA 4,400 VA 5,000 VA 6 5,500 VA 7 6,000 VA
Rated output voltage 220 Vac / 230 Vac / 240 Vac
Rated AC grid frequency 50 Hz / 60 Hz
Max. output current 10 A 15 A 16 A 20 A 23 A 8 25 A 8 27.3 A
Adjustable power factor 0.8 leading ... 0.8 lagging
Max. total harmonic distortion ≤3%
Backup power output Yes (via Backup Box-5000 1)

Protection & Feature


Anti-Islanding protection Yes
DC reverse polarity protection Yes
Insulation monitoring Yes
DC surge protection Yes, compatible with TYPE II protection class according to EN/IEC 61643-11
AC surge protection Yes, compatible with TYPE II protection class according to EN/IEC 61643-11
Residual current monitoring Yes
AC overcurrent protection Yes
AC short-circuit protection Yes
AC overvoltage protection Yes
Over-heat protection Yes
Arc fault protection Yes
Battery reverse charging from grid Yes

General Data
Operating temperature range -25 ~ +60 °C (Derating above 45°C @ Rated output power)
Relative operating humidity 0 %RH~100 %RH
Operating altitude 0 ~ 4,000 m (Derating above 2,000 m)
Cooling Natural convection
Display LED indicators; integrated WLAN + FusionSolar APP
RS485, WLAN via inverter built-in WLAN module
Communication
Ethernet via Smart Dongle-WLAN-FE (Optional); 4G / 3G / 2G via Smart Dongle-4G (Optional)
Weight (incl. mounting bracket) 12.0 kg (26.5 lb)
Dimension (incl. mounting bracket) 365mm * 365mm * 156 mm (14.4 x 14.4 x 6.1 inch)
Degree of protection IP65

Optimizer Compatibility
DC MBUS compatible optimizer SUN2000-450W-P

Standard Compliance (more available upon request)


Safety EN/IEC 62109-1, EN/IEC 62109-2
G98, G99, EN 50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777.2, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, IEC61727,
Grid connection standards
IEC62116
*1 Available in 2020 Q3.
*2 Inverter max input PV power is 10,000 Wp when long strings are designed and fully connected with SUN2000-450W-P power optimizers.
*3 The maximum input voltage and operating voltage upper limit will be reduced to 495 V when inverter connects and works with LG battery.
*4 2,500 W @ 5kWh HUAWEI ESS battery
*5 AS4777.2: 4,991W. *6. VDE-AR-N 4105: 4,600VA / AS4777.2: 4,999VA. *7. AS4777.2, C10/11, RD1699: 5,000VA. *8. AS4777.2: 21.7A.
Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/
Smart PV Optimizer

One-Fits-All Optimizer Arc Fault Pinpoint


<1.5 min Pairing with Inverter <5s Module Auto-Mapping
Easier Business Positioning

Technical Specification SUN2000-450W-P

Input
Rated Input DC Power 1 450 W
Absolute maximum input voltage 80 V
MPPT operating voltage range 8 - 80 V
Maximum Short Circuit Current (Isc) 13 A
Max. efficiency 99.5 %
Weighted efficiency 99.0 %
Overvoltage category II

Output
Max. output voltage 80 V
Max. output current 15 A
Output bypass 2 Yes
Shutdown output voltage per optimizer 3 0V
Shutdown output impedance per optimizer 1k ohm ± 10 %

Standard Compliance
Safety IEC62109-1 (class II safety)
RoHS Yes

General Data
Dimension (W x H x D) 71 x 138 x 25 mm (2.8 x 5.4 x 1.0 inch)
Weight (including cables) 0.55 kg (1.2 lb.)
Installation part (optional) Grounding Plate, Grounding Lug, PV Module Frame Plate
Input connector MC4
Output connector MC4
Output wire length 1.2 m (3.9 ft.) 4
Operating temperature / humidity range -40 ℃~85 ℃ 5 / 0 %RH~100 %RH
Degree of protection IP68
Compatible product SUN2000-2/3/3.68/4/4.6/5/6KTL-L1, SUN2000-3/4/5/6/8/10KTL-M1, SUN2000-12/15/17/20KTL-M2

Long String Design (Full Optimizer) SUN2000-2-6KTL-L1 SUN2000-3-10KTL-M1 SUN2000-12-20KTL-M2


Minimum optimizer number per string 4 6 6
Maximum optimizer number per string 25 50 50
Maximum DC power per string 5,000 W 10,000 W 10,000 W
*1 Rated power of the module at STC shall not exceed “Rated Input DC Power” of power optimizer. Modules with power up to +5% power tolerance are acceptable.
*2 Power optimizer is bypassed in the string connected to an operating inverter when it fails to work
*3 Power optimizer output 0Vdc when disconnecting to the inverter or inverter is shutdown.
*4 Fits PV module in landscape and portrait installation.
*5 Full power capability refers to online smart design tool.

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


Smart Energy Center

Higher Revenue Simple & Easy Battery Ready Safe & Reliable
Max. efficiency 98.6% 17 kg Plug & Play battery interface Arc fault protection

Efficiency Curve Circuit Diagram


Efficiency [%]
DC
100% Switch

PV1+
98%
DC/AC Output
PV1- EMI Converter Isolation Relay
Filter
96% PV2-
L1
PV2+
94% Output EMI L2
Filter Filter
L3
92% SPD
N
BAT+ PE

90% BAT-
SPD
0% 20% 40% 60% 80% 100%
470 V 600 V 850 V
Load [%] SUN2000-3/4/5/6/8/10KTL-M0

SOLAR.HUAWEI.COM/EU/
SUN2000-3/4/5/6/8/10KTL-M0
Technical Specification

SUN2000 SUN2000 SUN2000 SUN2000 SUN2000 SUN2000


Technical Specification -3KTL-M0 -4KTL-M0 -5KTL-M0 -6KTL-M0 -8KTL-M0 -10KTL-M0

Efficiency
Max. efficiency 98.2% 98.3% 98.4% 98.6% 98.6% 98.6%
European weighted efficiency 96.7% 97.1% 97.5% 97.7% 98.0% 98.1%

Input
Recommended max. PV power 6,000 Wp 8,000 Wp 10,000 Wp 12,000 Wp 14,880 Wp 14,880 Wp
Max. input voltage 1 1,100 V
Operating voltage range 2 140 V ~ 980 V
Start-up voltage 200 V
Full power MPPT voltage range 140 V ~ 850 V 190 V ~ 850 V 240 V ~ 850 V 285 V ~ 850 V 380 V ~ 850 V 470 V ~ 850 V
Rated input voltage 600 V
Max. input current per MPPT 11 A
Max. short-circuit current 15 A
Number of MPP trackers 2
Max. number of inputs 2

Output
Grid connection Three-phase
Rated output power 3,000 W 4,000 W 5,000 W 6,000 W 8,000 W 10,000 W
Max. apparent power 3,300 VA 4,400 VA 5,500 VA 6,600 VA 8,800 VA 11,000 VA 3
Rated output voltage 220 Vac / 380 Vac, 230 Vac / 400 Vac, 3W / N+PE
Rated AC grid frequency 50 Hz / 60 Hz
Max. output current 5.1 A 6.8 A 8.5 A 10.1 A 13.5 A 16.9 A
Adjustable power factor 0.8 leading ... 0.8 lagging
Max. total harmonic distortion ≤3%

Features & Protections


Input-side disconnection device Yes
Anti-Islanding protection Yes
DC reverse polarity protection Yes
Insulation monitoring Yes
DC surge protection Yes, compatible TYPE II protection class according to EN/IEC 61643-11
AC surge protection Yes, compatible TYPE II protection class according to EN/IEC 61643-11
Residual current monitoring Yes
AC overcurrent protection Yes
AC short-circuit protection Yes
AC overvoltage protection Yes
Arc fault protection Yes
Ripple receiver control Yes
DC MBUS to optimizer No

General Data
Operating temperature range -25 ~ + 60 °C (-13 °F ~ 140 °F) (Derating above 45 °C @ Rated output power)
Relative operating humidity 0 %RH~100 %RH
Operating altitude 0 - 4,000 m (13,123 ft.) (Derating above 3000 m)
Cooling Natural convection
Display LED Indicators; Integrated WLAN + FusionSolar App
RS485;
Communication
RS485; WLAN/Ethernet via Smart Dongle-WLAN-FE; 4G / 3G / 2G via Smart Dongle-4G (Optional)
Weight (incl. mounting bracket) 17 kg (37.5 lb)
Dimension (incl. mounting bracket) 525 x 470 x 166 mm (20.7 x 18.5 x 6.5 inch)
Degree of protection IP65
Nighttime Power Consumption < 5.5 W

Standard Compliance (more available upon request)


Certificate EN/IEC 62109-1, EN/IEC 62109-2
G98, G99, EN 50438, EN50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4,
Grid connection standards
IEC61727, IEC62116, DEWA
*1 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.
*2 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.
*3 C10 / 11: 10,000 VA

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


Smart Dongle-WLAN-FE

Smart Simple Reliable


WLAN & Fast Ethernet (FE) communication Plug & Play IP65
Support 3rd-party monitoring system 1 Support max. 10 devices Support auto reconnection

Technical Specification SDongleA-05

General Data
Max. Devices Supported 10
Max. Inverters Supported 10
Connection interface USB
Ethernet Interface 10/100M Ethernet
Installation Plug-and-play
Indicator LED Indicator
Dimensions (W * H * D) 146 x 48 x 33 mm (5.1 x 1.9 x 1.3 inch)
Weight 90 g (0.2 lb.)
Degree of protection IP65
Power consumption (typical) 2.5 W
Operation Mode STA

Encryption Mechanism:WPA/WPA2
Encryption Algorithm
Encryption:TKIP/CCMP/AES

Wireless Parameter
Supported standards & frequencies 802.11b/g/n(2.412G—2.484G)

Environment
Operating temperature range -30 ℃ to +65 ℃ (-22 ℉ to 149 ℉)
Relative humidity range 5 - 95% RH
Storage temperature range -40℃ to +70℃ (-40 ℉ to 158 ℉)
Max. operating altitude 4,000 m (13,123 ft.)

Standard Compliance (more available upon request)


Certificate SRRC, CE, RCM

Inverter Compatibility
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1
Inverter model SUN2000-3/4/5/6/8/10KTL-M0
SUN2000-12/15/17/20KTL-M0

*1: 3rd-party management system shall match the communication protocol with Huawei Smart Dongle.

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


Smart Dongle-4G

Smart Simple Reliable


2G, 3G, 4G communication 1 Plug & Play IP65
Support 3rd-party monitoring system 2 Support max. 10 devices Support auto reconnection

Technical Specification SDongleA-03-EU

General Data
Max. Devices Supported 10
Max. Inverters Supported 10
Connection interface USB
Installation Plug-and-play
Indicator LED Indicator
Dimensions (W * H * D) 130 x 48 x 33 mm (5.1 x 1.9 x 1.3 inch)
Weight 90 g (0.2 lb.)
Degree of protection IP65
Power consumption (typical) 3.5 W

Wireless Parameter
Sim card type mini-sim (15 mm*25 mm)

4G: FDD-LTE / TDD-LTE


Supported standards & frequencies 3G: WCDMA / HSDPA / HSUPA / HSPA+
2G: GSM / GPRS / EDGE 3

Environment
Operating temperature range -30 ℃ to +65 ℃ (-22 ℉ to 149 ℉)
Relative humidity range 5 - 95% RH
Storage temperature range -40 ℃ to +70 ℃ (-40 ℉ to 158 ℉)
Max. operating altitude 4,000 m (13,123 ft.)

Standard Compliance (more available upon request)


Certificate CE, Type Approval for Thailand, MIC

Inverter Compatibility
SUN2000-2/3/3.68/4/4.6/5/6KTL-L1
SUN2000-3/4/5/6/8/10KTL-M0
Inverter model SUN2000-12/15/17/20KTL-M0
SUN2000-60KTL-M0
SUN2000-100KTL-M1
1: To ensure stable data transmission, Huawei suggests 4G dongle to be installed in areas with stable mobile signal (2G signal ≥4 bars, 3G/4G signal ≥3 bars).
2: 3rd-party management system shall match the communication protocol with Huawei Smart Dongle.
3. For recommended carriers list and details on supported frequencies, please contact local distributors.

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


Smart Power Sensor

Accurate Simple & Easy Energy Efficient


Class 1 measurement accuracy LCD display, easy to set and check Overall power consumption ≤ 1 W

Technical Specification DDSU666-H DTSU666-H 250A/50mA

General Data
100 x 36 x 65.5 mm 100 x 72 x 65.5 mm
Dimension (H x W x D)
(3.9 x 1.4 x 2.6 inch) (3.9 x 2.8 x 2.6 inch)
Mounting type DIN35 Rail
Weight (including cables) 1.2 kg (2.6 lb) 1.5 kg (3.3 lb)

Power Supply
Power grid type 1P2W 3P4W
Input voltage (phase voltage) 176 Vac ~ 288 Vac
Power consumption ≤ 0.8 W ≤1W

Measurement Range
Line voltage / 304 Vac ~ 499 Vac
Phase voltage 176 Vac ~ 288 Vac
Current 0 ~ 100 A 0 ~ 250 A

Measurement Accuracy
Voltage ±0.5 %
Current / Power / Energy ±1 %
Frequency ±0.01 Hz

Communication
Interface RS485
Baud rate 9,600 bps
Communication protocol Modbus-RTU

Environment
Operating temperature range -25 ℃ ~ 60 ℃
Storage temperature range -40 ℃ ~ 70 ℃
Operating humidity 5 %RH ~ 95 %RH (non-condensing)

Others
RS485 Cable (10 m / 33 ft.)
1 CT 100 A/40 mA (5 m/16.4 ft.) 3 CT 250 A/50 mA (5 m/16.4 ft.)
Accessories

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


Commercial PV Solution

SmartLogger
4G/3G/2G
RS485
Weather Station FusionSolar Smart PV
RS485 Management system
PV Module Smart PV Inverter

PV Module Smart PV Inverter

PV Module Smart PV Inverter

Active Safety Higher Yields Maintenance Free

AI Powered Active Arcing 2 Strings per MPPT, More Energy No Fuse & Other Quick-wear Parts,
Protection Yields Inverter Touch Free

Built-in PID Recovery,


C&I Tailored Enhanced Arcing Online Smart I-V Curve Diagnosis,
Secure Better Module
Protection Performance Module Touch Free

SOLAR.HUAWEI.COM/EU/
Smart String Inverter

Higher Revenue Simple & Easy Safe & Reliable


Max. efficiency 98.65% 25 kg Arc fault protection

Efficiency Curve Circuit Diagram


Efficiency [%]
DC
99% Switch

PV1+
98% PV1- PVA
PV2+
DC/AC Output
97% PV2-
PVAB- EMI Converter Isolation Relay
Filter

96%
PV3+
L1
PV3- PVB
Output EMI L2
95% PV4+
Filter Filter
PV4-
L3
SPD
94% N
PE

93% SPD
0.00% 20.00% 40.00% 60.00% 80.00% 100.00%
480V 600V 850V

Load [%] SUN2000-12/15/17/20KTL-M0

SOLAR.HUAWEI.COM/EU/
SUN2000-12/15/17/20KTL-M0
Technical Specification

SUN2000 SUN2000 SUN2000 SUN2000


Technical Specification -12KTL-M0 -15KTL-M0 -17KTL-M0 -20KTL-M0

Efficiency
Max. efficiency 98.50% 98.65% 98.65% 98.65%
European weighted efficiency 98.00% 98.30% 98.30% 98.30%

Input
Recommended max. PV power 24,000 Wp 29,760 Wp 29,760 Wp 29,760 Wp
Max. input voltage 1 1,080 V
Operating voltage range 2 160 V ~ 950 V
Start voltage 200 V
Full power MPPT voltage range 380 Vdc~850 Vdc 380 Vdc~850 Vdc 400 Vdc~850 Vdc 480 Vdc~850 Vdc
Rated input voltage 600 V
Max. input current per MPPT 22 A
Max. short-circuit current 30 A
Number of MPP trackers 2
Max. number of inputs 4

Output
Grid connection Three phase
Rated output power 12,000 W 15,000 W 17,000 W 20,000 W
Max. apparent power 13,200 VA 16,500 VA 18,700 VA 22,000 VA
Rated output voltage 220 Vac / 380 Vac, 230 Vac / 400 Vac, 3W + N + PE
Rated AC grid frequency 50 Hz / 60 Hz
Max. output current 20 A 25.2 A 28.5 A 33.5 A
Adjustable power factor 0.8 leading ... 0.8 lagging
Max. total harmonic distortion ≤3%

Features & Protections


Input-side disconnection device Yes
Anti-islanding protection Yes
AC over-current protection Yes
AC short-circuit protection Yes
AC over-voltage protection Yes
DC reverse-polarity protection Yes
DC surge protection Type II
AC surge protection Yes, compatible TYPE II protection class according to EN/IEC 61643-11
Residual current monitoring unit Yes
Arc fault protection Yes
Ripple receiver control Yes

General Data
Operation temperature range -25 ~ + 60 °C (-13 °F ~ 140 °F) (Derating above 45 °C @ Rated output power)
Relative humidity 0 % RH ~ 100% RH
Max. operating altitude 0 - 4,000 m (13,123 ft.) (Derating above 2000 m)
Cooling Natural Convection
Display LED indicators; integrated WLAN + FusionSolar APP
RS485;
Communication WLAN/Ethernet via Smart Dongle-WLAN-FE (Optional)
4G / 3G / 2G via Smart Dongle-4G (Optional)
Weight (with mounting plate) 25 kg
Dimensions (W x H x D)
525 x 470 x 262 mm (20.7 x 18.5 x 10.3 inch)
(incl. mounting plate)
Degree of protection IP65
Nighttime Power Consumption < 5.5 W

Standard Compliance (more available upon request)


Safety EN/IEC 62109-1, EN/IEC 62109-2
G98, G99, EN 50438, EN50549, CEI 0-21, CEI 0-16, VDE-AR-N-4105, VDE-AR-N-4110, AS 4777, C10/11, ABNT, UTE
Grid connection standards
C15-712, RD 1699, RD 661, PO 12.3, TOR D4, IEC61727, IEC62116, DEWA
*1 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.
*2 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


SUN2000-33KTL-A
Smart String Inverter

Smart Efficient Safe Reliable


8 strings intelligent monitoring Max. efficiency 98.6% Fuse free design Type II surge arresters for DC & AC

Efficiency Curve Circuit Diagram


Efficiency [%]
100% +
+ MPPT1
-
98% -
L1
+
Output EMI L2
96% + MPPT2
Filter Filter L3
-
N
94% - DC EMI
DC/AC PE
Switch 1 Filter Output SPD
Inverter Relay
92%
+
+ MPPT3
-
90% -
+
0% 20% 40% 60% 80% 100% + MPPT4
-

480V 620V 850V -


SPD
Current DC
Sensor Switch 2

Load [%] SUN2000-33KTL-A

SOLAR.HUAWEI.COM/EU/
SUN2000-33KTL-A
Technical Specification

Technical Specification SUN2000-33KTL-A

Efficiency
Max. Efficiency 98.6%
European Efficiency 98.4%

Input
Max. Input Voltage 1 1,100 V
Max. Current per MPPT 22 A
Max. Short Circuit Current per MPPT 30 A
Start Voltage 250 V
MPPT Operating Voltage Range 2 200 V ~ 1,000 V
Rated Input Voltage 620 V
Number of MPP trackers 4
Max. number of inputs 8

Output
Rated AC Active Power 30,000 W
Max. AC Apparent Power 33,000 VA
Max. AC Active Power 30,000 W 3
Rated Output Voltage 230 V / 400 V, 3W + N + PE;
Rated AC Grid Frequency 50 Hz / 60 Hz
Rated Output Current 43.3 A
Max. Output Current 48 A
Adjustable Power Factor Range 0.8 leading... 0.8 lagging
Max. Total Harmonic Distortion <3%

Protection
Input-side Disconnection Device Yes
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes

Communication
Display LED indicators; WLAN adaptor + FusionSolar APP
RS485 Yes
USB Yes
Monitoring BUS (MBUS) Yes (isolation transformer required)

General Data
Dimensions (W x H x D) 930 x 550 x 283 mm (36.6 x 21.7 x 11.1 inch)
Weight (with mounting plate) 62 kg (136.7 lb.)
Operating Temperature Range -25 °C ~ 60 °C (-13°F ~ 140°F)
Cooling Method Natural Convection
Max. Operating Altitude 4,000 m (13,123 ft.)
Relative Humidity 0 ~ 100%
DC Connector Amphenol Helios H4
AC Connector Waterproof PG Terminal + OT Connector
Protection Degree IP65
Topology Transformerless
Nighttime Power Consumption < 2.5 W

Standard Compliance (more available upon request)


Certificate EN 62109-1/-2, IEC 62109-1/-2, IEC 62116
IEC 61727, VDE-AR-N-4105, VDE 0126-1-1, BDEW, G59/3, UTE C 15-712-1, CEI 0-16, CEI 0-21, RD 661, RD
Grid Code
1699, P.O. 12.3, RD 413, C10/11, EN 50438-Turkey, ABNT
*1 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.
*2 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.
*3. The maximum active power is determined by PQ mode setting. If PQ mode 1 is selected, the maximum active power equals the maximum apparent power. If PQ mode 2 is selected, the maximum active power
equals the rated active power.

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


SUN2000-36KTL
Smart String Inverter

Smart Efficient Safe Reliable


8 strings intelligent monitoring Max. efficiency 98.6% Fuse free design Type II surge arresters for DC & AC

Efficiency Curve Circuit Diagram


Efficiency [%] +
+ MPPT1
100% -
-
L1
98% +
Output EMI
+ MPPT2 L2
Filter Filter
- L3
96% PE
- DC EMI SPD
Switch 1 Filter DC/AC Output
Inverter
94% +
Relay

+ MPPT3
92% -
-
+
90% + MPPT4
0% 20% 40% 60% 80% 100% -
-
SPD
580V 720V 850V Current DC
Sensor Switch 2

Load [%] SUN2000-36KTL

SOLAR.HUAWEI.COM/EU/
SUN2000-36KTL
Technical Specification

Technical Specification SUN2000-36KTL

Efficiency
Max. Efficiency 98.8% @480 V; 98.6% @380 V / 400 V
European Efficiency 98.6% @480 V; 98.4% @380 V / 400 V

Input
Max. Input Voltage 1 1,100 V
Max. Current per MPPT 22 A
Max. Short Circuit Current per MPPT 30 A
Start Voltage 250 V
MPPT Operating Voltage Range 2 200 V ~ 1,000 V
Rated Input Voltage 620 V @380 Vac / 400 Vac; 720 V @480 Vac
Number of MPP trackers 4
Max. number of inputs 8

Output
Rated AC Active Power 36,000 W
Max. AC Apparent Power 40,000 VA
Max. AC Active Power (cosφ=1) Default 40,000 W; 36,000 W optional in settings
220 V / 380 V, 230 V / 400 V, default 3W + N + PE; 3W + PE optional in settings
Rated Output Voltage
277 V / 480 V, 3W + PE
Rated AC Grid Frequency 50 Hz / 60 Hz
Rated Output Current 54.6 A @380 V, 52.2 A @400 V, 43.4 A @480 V
Max. Output Current 60.8 A @380 V, 57.8 A @400 V, 48.2 A @480 V
Adjustable Power Factor Range 0.8 leading... 0.8 lagging
Max. Total Harmonic Distortion <3%

Protection
Input-side Disconnection Device Yes
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes

Communication
Display LED indicators; WLAN adaptor + FusionSolar APP
RS485 Yes
USB Yes
Monitoring BUS (MBUS) Yes (isolation transformer required)

General Data
Dimensions (W x H x D) 930 x 550 x 283 mm (36.6 x 21.7 x 11.1 inch)
Weight (with mounting plate) 62 kg (136.7 lb.)
Operating Temperature Range -25°C ~ 60°C (-13°F ~ 140°F)
Cooling Method Natural Convection
Max. Operating Altitude 4,000 m (13,123 ft.)
Relative Humidity 0 ~ 100%
DC Connector Amphenol Helios H4
AC Connector Waterproof PG Terminal + OT Connector
Protection Degree IP65
Topology Transformerless
Nighttime Power Consumption < 2.5 W

Standard Compliance (more available upon request)


Certificate EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 60068, IEC 61683
IEC 61727, VDE-AR-N4105, VDE 0126-1-1, BDEW, G59/3, UTE C 15-712-1, CEI 0-16, CEI 0-21, RD 661, RD 1699,
Grid Code
P.O. 12.3,RD 413, EN-50438-Turkey, EN-50438-Ireland, C10/11, MEA, Resolution No.7, NRS 097-2-1, AS/NZS 4777.2

*1 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.
*2 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


SUN2000-60KTL-M0
Smart String Inverter

Smart Efficient Safe Reliable


12 strings intelligent monitoring Max. efficiency 98.7% Fuse free design Type II surge arresters for DC & AC

Efficiency Curve Circuit Diagram


+
MPPT1
Efficiency [%]
+
-

100%
-
L1
+
Output EMI L2
MPPT2
99%
+
Filter Filter L3
-
N
98% -
DC/AC Output
+ Inverter Isolation SPD PE
97% + MPPT3 Relay
- EMI
96% -
DC SPD Filter
Switch 1
95%
+
94% + MPPT4
-
93% -
+
92% + MPPT5

91%
-
-

90% +
+ MPPT6
0% 20% 40% 60% 80% 100% -
-
SPD
520V 600V 800V Current DC
Sensor Switch 2

Load [%] SUN2000-60KTL-M0

SOLAR.HUAWEI.COM/EU/
SUN2000-60KTL-M0
Technical Specification

Technical Specification SUN2000-60KTL-M0

Efficiency
Max. efficiency 98.9% @480 V; 98.7% @380 V / 400 V
European efficiency 98.7% @480 V; 98.5% @380 V / 400 V

Input
Max. Input Voltage 1 1,100 V
Max. Current per MPPT 22 A
Max. Short Circuit Current per MPPT 30 A
Start Voltage 200 V
MPPT Operating Voltage Range 2 200 V ~ 1,000 V
Rated Input Voltage 600 V @380 Vac / 400 Vac; 720 V @480 Vac
Number of MPP trackers 6
Max. number of inputs 12

Output
Rated AC Active Power 60,000 W
Max. AC Apparent Power 66,000 VA
Max. AC Active Power (cosφ=1) 66,000 W
Rated Output Voltage 220 V / 380 V, 230 V / 400 V, default 3W + N + PE; 3W + PE optional in settings; 277 V / 480 V, 3W + PE
Rated AC Grid Frequency 50 Hz / 60 Hz
Rated Output Current 91.2 A @380 V, 86.7 A @400 V, 72.2 A @480 V
Max. Output Current 100 A @380 V, 95.3 A @400 V, 79.4 A @480 V
Adjustable Power Factor Range 0.8 leading... 0.8 lagging
Max. Total Harmonic Distortion <3%

Protection
Input-side Disconnection Device Yes
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes

Communication
Display LED indicators; WLAN adaptor + FusionSolar APP
RS485 Yes
USB Yes
Monitoring BUS (MBUS) Yes (isolation transformer required)

General Data
Dimensions (W x H x D) 1,075 x 555 x 300 mm (42.3 x 21.9 x 11.8 inch)
Weight (with mounting plate) 74 kg (163.1 lb.)
Operating Temperature Range -25°C ~ 60°C (-13°F ~ 140°F)
Cooling Method Natural Convection
Max. Operating Altitude 4,000 m (13,123 ft.)
Relative Humidity 0 ~ 100%
DC Connector Amphenol Helios H4
AC Connector Waterproof PG Terminal + Terminal Clamp
Protection Degree IP65
Topology Transformerless
Nighttime Power Consumption <2W

Standard Compliance (more available upon request)


Certificate EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 60068, IEC 61683
IEC 61727, VDE-AR-N4105, VDE 0126-1-1, BDEW, VDE 4120, UTE C 15-712-1, CEI 0-16, CEI 0-21, RD 661, RD 1699,
Grid Connection Standards
P.O. 12.3, RD 413, EN-50438-Turkey, EN-50438-Ireland, C10/11
*1 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.
*2 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


SUN2000-100KTL-M1
Smart String Inverter

10 98.8% (@480V) String-level Smart I-V Curve Diagnosis


MPP Trackers Max. Efficiency Management Supported

MBUS Fuse Free Surge Arresters for IP66


Supported Design DC & AC Protection

Efficiency Curve Circuit Diagram


+

SUN2000-100KTL-M1 @480 V + MPPT1


Efficiency [%] -
-
+ L1
Output EMI
100% + MPPT2
Filter Filter
L2
- L3
- N
99% + DC/AC Output SPD PE
+ MPPT3 Inverter Relay
98%
-
- DC SPD
Switch 1
97% +
+ MPPT4
-

96%
-
+
+ MPPT5
95% -
-
EMI
+
Filter
94% +
-
MPPT6

-
DC SPD
93% Switch 2
+
+ MPPT7
92% -
-
+

91% + MPPT8
-

90%
-

+
MPPT9
0% 20% 40% 60% 80% 100%
+
-

625 V 720 V 850 V


-

+
+
MPPT10
-
- SPD
Load [%] Current DC
Sensor Switch 3

SOLAR.HUAWEI.COM/EU/
SUN2000-100KTL-M1
Technical Specification

Technical Specification SUN2000-100KTL-M1

Efficiency
Max. efficiency 98.8% @480 V, 98.6% @380 V / 400 V
European efficiency 98.6% @480 V, 98.4% @380 V / 400 V

Input
Max. Input Voltage 1 1,100 V
Max. Current per MPPT 26 A
Max. Short Circuit Current per MPPT 40 A
Start Voltage 200 V
MPPT Operating Voltage Range 2 200 V ~ 1,000 V
Nominal Input Voltage 720 V @480 Vac, 600 V @400 Vac, 570 V @380 Vac
Number of MPP trackers 10
Max. number of inputs 20

Output
Nominal AC Active Power 100,000 W
Max. AC Apparent Power 110,000 VA
Max. AC Active Power (cosφ=1) 110,000 W
Nominal Output Voltage 480 V/ 400 V/ 380 V, 3W+(N)+PE
Rated AC Grid Frequency 50 Hz / 60 Hz
Nominal Output Current 120.3 A @480 V, 144.4 A @400 V, 152.0 A @380 V
Max. Output Current 133.7 A @480 V, 160.4 A @400 V, 168.8 A @380 V
Adjustable Power Factor Range 0.8 leading... 0.8 lagging
Max. Total Harmonic Distortion <3%

Protection
Input-side Disconnection Device Yes
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes

Communication
Display LED indicators; WLAN adaptor + FusionSolar APP
RS485 Yes
USB Yes
Monitoring BUS (MBUS) Yes (isolation transformer required)

General Data
Dimensions (W x H x D) 1,035 x 700 x 365 mm
Weight (with mounting plate) 90 kg
Operating Temperature Range -25°C ~ 60°C
Cooling Method Smart Air Cooling
Max. Operating Altitude without Derating 4,000 m
Relative Humidity 0 ~ 100%
DC Connector Staubli MC4
AC Connector Waterproof Connector + OT/DT Terminal
Protection Degree IP66
Topology Transformerless
Nighttime Power Consumption < 3.5 W

Standard Compliance (more available upon request)


Certificate EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 61727, IEC 60068, IEC 61683
Grid Connection Standards VDE-AR-N4105, EN 50549-1, EN 50549-2, RD 661, RD 1699, C10/11
*1 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.
*2 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.
Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/
SmartLogger3000A

Smart Simple Reliable


Smart zero export control design Easy to install on site Safety by lightning protection module

Technical Specification SmartLogger3000A03EU SmartLogger3000A01EU

Device Management
Max. Number of Connected Devices 80

Communication Interface
WAN WAN x 1, 10 / 100 / 1000 Mbps
LAN LAN x 1, 10 / 100 / 1000 Mbps
RS485 COM x 3, 1200 / 2400 / 4800 / 9600 / 19200 / 115200 bps, 1000 m
MBUS MBUS x 1, 115.2 kbps, Compatible with PLC No MBUS Communication Interface
LTE(FDD):B1,B2,B3,B4,B5,B7,B8,B20
2G / 3G / 4G 1 DC-HSPA+/HSPA+/HSPA/UMTS: 850/900/1900/2100 MHz
GSM/GPRS/EDGE: 850/900/1800/1900 MHz 2
Digital / Analog Input / Output DI x 4, DO x 2, AI x 4
Active DO 12V, 100mA (connection with relay, sensor)

Communication Protocol
Ethernet Modbus-TCP, IEC 60870-5-104
RS485 Modbus-RTU, IEC 60870-5-103 (standard), DL / T645

Interaction
LED LED Indicator x 3 – RUN, ALM, 4G
WEB Embedded Web
USB USB 2.0 x 1
APP Communication by WLAN for Commissioning

Environment
Operating Temperature Range -40°C ~ 60°C (-40°F ~ 140°F)
Storage Temperature -40°C ~ 70°C (-40°F ~ 158°F)
Relative Humidity (Non-condensing) 5% ~ 95%
Max. Operating Altitude 4,000 m (13,123 ft.)

Electrical
AC Power Supply 100 V~240 V, 50 Hz / 60 Hz
DC Power Supply 12 V / 24 V
Power Consumption Typical 8 W, Max. 15 W

Mechanical
Dimensions (W x H x D) 225 x 160 x 44 mm (8.9 x 6.3 x 1.7 inch, without mounting ears and antenna)
Weight 2 kg (4.4 lb.)
Protection Degree IP20
Installation Options Wall Mounting, DIN Rail Mounting, Tabletop Mounting
*1: When putting inside metal box, extended antenna will be needed.
*2: For recommended carriers list and details on supported frequencies, please contact local distributors.

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


FusionSolar Smart PV Management System

Simple & Swift


• Simple commissioning by APP
• Auto-detection of system equipment
• Registering your plant by scanning any
device

Convenient & Reliable


• Energy flow illustration
• Real-time data at anytime from
anywhere
• Performance data back-up

Improved O&M Experience


• Physical & logical module layout
• Module-level performance management*
• Smart I-V Diagnosis

* Full optimizer is required for SUN2000-2-6KTL-L1;

Feature List WEB APP

Swift Installation & Registration

Data Collection

Dashboard

Energy Flow

Basic
Energy Generation & Consumption
Feature

Device Management

Report Management

Alarm Management

System Configuration

Intelligent O&M

Mobile O&M
Advanced
Feature
Proactive Diagnosis

Smart I-V Curve Diagnosis

Basic Optional

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


Smart I-V Curve Diagnosis

Smart I-V Curve Diagnosis is able to carry out online I-V curve analysis on entire strings with
advanced diagnosis algorithm. The scanning would help to find out and identify the strings
with low performance or faults, which would help to achieve proactive maintenance, higher
O&M efficiency and lower operation cost.

Smart
 Support plant-level, array-level and inverter-level analysis and
diagnosis
 Automatically identify different failure types and provide recovery
suggestion

Efficient
 One-click scanning without onsite experts or equipment
 Online I-V curve scanning on entire strings of 5 MW plant within 5min
 Automatic report generation of 5 MW plant within 15min

Network

One Click Scanning Smart I-V Curve Diagnosis Report

Ethernet

FusionSolar
SmartLogger
Smart PV Management system
WLAN 3G/4G RS485

Weather Station
(optional)

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


Smart I-V Curve Diagnosis

Technical Specifications Smart I-V Curve Diagnosis

SUN2000-2/3/3.68/4/4.6/5/6KTL-L1*, SUN2000-3/4/5/6/8/10KTL-M0,
Smart PV Inverter SUN2000-12/15/17/20KTL-M0, SUN2000-33KTL-A/36KTL, SUN2000-
60KTL-M0, SUN2000-100KTL-M1

Communication SmartLogger3000A, Smart Dongle-WLAN-FE/4G

Management System FusionSolar Smart PV Management System, NetEco1000s

Scanning Time <1s (1 string)

Sampling Points per I-V Curve 128

Certification TUV
* I-V curve diagnosis is not supported when inverter is connected with power optimizer.

String-level Management Smart I-V Curve Diagnosis

Real time monitoring Fault Analysis

String I-V Curve Comparison


9
8
7
Current [A]

6
5
4
3 Normal Curve
2
1 Abnormal Curve with shading on Modules
0
0 100 200 300 400 500 600 700 800
Voltage [V]
9
8
Current [A]

7
6
5
4
3 Normal Curve
2
Abnormal Curve with String Current Mismatch
1
0
0 100 200 300 400 500 600 700 800
Voltage [V]

Version No.:03-(20200409) SOLAR.HUAWEI.COM/EU/


Case Reference

4kW
设备图 Residential PV System in Waregem, Belgium
COD
May, 2018
System Configuration
• 18 × 295Wp modules
• 6 × 375W optimizers
• SUN2000L-4KTL, WLAN
• Smart PV safety box

8kW
设备图 Residential energy system in Sydney, Australia COD
Dec, 2017
System Configuration
• 36 × 270Wp modules
• 24 × 375W optimizers
• SUN2000L-3KTL & -5KTL
• LG Chem RESU10H Type R

SOLAR.HUAWEI.COM/EU/
Case Reference

15kW
设备图 Residential PV system in NSW, Australia
COD
Feb, 2019
System Configuration
• 37 × 310Wp Longi modules, 12 x existed old modules
• 3 x SUN2000L-5KTL
• WLAN communication

33kW
Residential PV system in Hanadacho Chokushi, Japan
COD
April, 2018
System Configuration
• 120 × 275Wp modules
• 8 × SUN2000L-4.125KTL-JP
• SmartACBox12in1

SOLAR.HUAWEI.COM/EU/
Case Reference

1MWp
Distributed PV System in Kuala Lumpur,Malaysia
COD
Mar 2016
System Configuration
• SUN2000-36KTL

2.8MWp
设备图 Distributed PV system at Singapore Changi Airport
COD
System Configuration Dec, 2016

• SUN2000-36KTL

SOLAR.HUAWEI.COM/EU/
Case Reference

85.8KWp
Distributed PV System in Brazil
COD
System Configuration Feb, 2018
• 264 x 325Wp modules
• 2 x SUN2000-36KTL

260KWp
Distributed PV System in Brazil
COD
Mar, 2018
System Configuration
• 788 x 330Wp modules
• 4 x SUN2000-36KTL

SOLAR.HUAWEI.COM/EU/
Case Reference

616KWp
Distributed PV System in Multan, Pakistan
COD
Oct, 2019
System Configuration
• SUN2000-36 KTL
• SUN2000-60 KTL

1.25MWp
Distributed PV System in South Africa
COD
System Configuration Sep, 2019
• SUN2000-60KTL

SOLAR.HUAWEI.COM/EU/