0% found this document useful (0 votes)
233 views3 pages

11.2.1 Clivet DX Modular Air Handling Unit Compressed

This document provides specifications for a Clivet DX modular air handling unit. It has a cooling capacity range of 47,700 to 680,000 BTU/H and a heating capacity range of 16 to 220 kW. It can be configured with HEPA and sterilization functions and is compatible with different outdoor unit series. The unit has optional fresh air and return air configurations. It uses high strength aluminum alloy frames and patented chassis structure with low air leakage. It also features high performance heat exchangers, efficient fans and motors, and an inclining drain pan.

Uploaded by

irwantino susilo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
233 views3 pages

11.2.1 Clivet DX Modular Air Handling Unit Compressed

This document provides specifications for a Clivet DX modular air handling unit. It has a cooling capacity range of 47,700 to 680,000 BTU/H and a heating capacity range of 16 to 220 kW. It can be configured with HEPA and sterilization functions and is compatible with different outdoor unit series. The unit has optional fresh air and return air configurations. It uses high strength aluminum alloy frames and patented chassis structure with low air leakage. It also features high performance heat exchangers, efficient fans and motors, and an inclining drain pan.

Uploaded by

irwantino susilo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

All fresh air and all return air are optionalCooling

13. Nomenclature 15. Function Section Aplication


capacity range from 47.700~680.00 btuh
Heating capacity range from 16~220kWHEPA can
be configured
Sterilization can be configured
Compatible with different type of ODU series

Clivet
DX Modular
Air Handling Unit

14. ODU Dimensions 16. Fliw Ilustration

Commercial Air Conditioner Division


Clivet Group
Add.: Clivet Headquarters Building, 6 Clivet Avenue, Shunde, Foshan, Guangdong, China

Postal code: 528311

cac.clivet.com global.clivet.com

Note: Product specifications change from time to time as product improvements and developments are released and may vary from those in this document.

09 10
5. IDU Function Specifications 7. Sample Medical
Sample 1: Sample 2:
10. 1 Parameter of Air-cooled DX Constant Temperature/Purifiying Unit 11. 1 Parameter of Air-cooled DX Fresh Air Handling Unit
Function Section Size (mm) Features Applicable for all fresh air purposes for ordinary cases. Applicable for hospitals, clinics and temporary hospitals.
Aluminum
Air inlet Section length = 600 1. Patented chassis st ructure, with low air leakage and high strength Screw bolt Sealing strip alloy frame 2 PU injection

+
Aluminum
alloy frame 1
Interior uses high-strength
Primary filter Section length = 100 aluminium material

Rubber strip

Standard bag length = 381,


Split-type with structure made Anti-corrosion
coated steel sheet
Sealing strip
Sub-Hepa filter from composite material Galvanized
steel sheet
section length = 500
Air inlet+primary filter Supply HEPA filter+ Primary filter+ HEPA filter + DX coil + Electrode Constant temperature
DX coil Section length = 600/800 2. High performance heat exchanger +secondary filter fan DX coil+UV light Secondary filter UV light + Electric heater humidifier and humidity controller

Electric heating Section length = 300


We also support placing the HEPA filter in front of the room outlet

Electrostatic dedusting Section length = 400

3. High efficiency centrifugal fan and high quality motor for optimal working point and efficiency of the fan
Humidifying /

Fan /
HEPA filter

High efficiency filter Section length = 500


ROOM
4. Inclining drain pan for quick condensate drainage
Air Cleaning Options:
Flow equalization Section length = 700
Type Principle Advantage

Noise reduction Section length = 600 Electrostatic filter High voltage electrostatic adsorption Highly efficient way of dust removal and sterilization

Photon Hydroxylation Technology air purifying disinfector. Photochemical decomposition and oxidation technology High efficient way of sterilization and removal 10. 2 Parameter of Air-cooled DX Constant Temperature/Purifiying Unit
6. Control systemses Wired controllers
of gaseous pollutants and odour
11. 2 Parameter of Air-cooled DX Fresh Air Handling Unit
(TiO2 ) ARC-FLASH Light catalysis oxidation Bactericidal
Blower, T1,T2,T2B
BMS Water pump
Ultra- Violet Rays Principle of ultraviolet sterilization High bactericidal properties

Control cabinet
P,Q,E Ozoniser Ozone sterilization High bactericidal properties
A,C,C

X,Y,E

X,Y,E
8. Operating range
Power line
X,Y,E Liquid pipe Type Cooling capacity (KW) Heating capacity (KW) Air volume (m3/h)
Liquid pipe
V6 Series /
Air return system 14~200 16~220
DX AHU 2500~40000

V6 Series /
X,Y,E Air fresh system 14~196 16~215
AHU kit DX AHU 1500~19000

Gas pipe
9. AHU KIT
KJR-29B wired controller: Model AHUKZ-01B AHUKZ-02B AHUKZ-03B
1. The wired controller features multiple modes, timed on/off, and temperature setting; Capacity(kW) 9~20 20~36 36~56
2. Alarm and real-time monitoring ensures reliable operation of the unit.
Liquid pipe inlet Φ8 Φ12.7 Φ15.9
Pipe connection(mm)
Starter panel: Liquid pipe outlet Φ8 Φ12.7 Φ15.9
1. Manual/automatic switch, remote control and motor speed control (DC motor);
2. Thermal relay protection, emergency stop, and status indicator;
If your requirement exceeds the above capacity range, please contact Midea, we will provide corresponding solutions according to your demand.
3. Fire alarm and fire control linkage.

05 06 07 08
1-1. Specifications (Return air condition) 2-1. Specifications (Fresh air condition) 3. ODU Dimensions 4. ODU Features
IDU air flow (m³/h) 2500 4000 5000 6000 7500 IDU air flow (m³/h) 1500 1900 2500 3000 4000 Model: MV6-i252WV2GN1, MV6-i335WV2GN1
EVI compressor Environmentally-friendly R410A refrigerant
Model IDU model (modulus) 0609 0612 0909 0912 0915 IDU model (modulus) 0609 0609 0909 0909 0912
Model

ODU model MV6-i252WV2GN1 MV6-i252WV2GN1 MV6-i280WV2GN1 MV6-i335WV2GN1 MV6-i450WV2GN1 ODU model MV6-i252WV2GN1 MV6-i252WV2GN1 MV6-i252WV2GN1 MV6-i335WV2GN1 MV6-i400WV2GN1
Thanks to the vapor injection DC The unit carries R410A when delivered
System Rated cooling capacity (kW) 14 21 28 33 45 System Rated cooling capacity (kW) 14 20 25 30 40
inverter compressor, the V6 VRF can from the factory, which is
parameters Rated heating capacity (kW) 16 23 30 35 50 parameters Rated heating capacity (kW) 16 22 27 33 44 990
run heating mode stably down to environment-friendly, non-toxic,

1635
Compressor Enhanced vapor injection DC inverter scroll compressor Compressor Enhanced vapor injection DC inverter scroll compressor -25°C, and the heating capacity can be energy efficient and not damaging to
Throttling mode Electronic expansion valve Throttling mode Electronic expansion valve improved greatly. the atmosphere's ozone layer.
ODU ODU

790
Power input (kW) 5.4/5.8 5.4/5.8 5.4/5.8 8.1/8.6 10.2/10.7 Power input (kW) 5.4/5.8 5.4/5.8 5.4/5.8 8.1/8.6 10.2/10.7
Noise value dB(A) 56 56 56 59 60 Noise value dB(A) 56 56 56 59 59

Refrigerant R410A charge amount (kg) 11 11 11 11 13 Refrigerant R410A charge amount (kg) 11 11 11 11 13
Connection methods Welding connection Connection methods Welding connection Front view Side view Top view
Easy to install Long refrigerant pipe allows easier installation
Connecting pipe Liquid pipe 12.7 12.7 12.7 12.7 15.9 Connecting pipe Liquid pipe 12.7 12.7 12.7 12.7 15.9
Dimension Dimension
Gas pipe 25.4 25.4 25.4 25.4 28.6 Gas pipe 19.1 19.1 19.1 19.1 25.4 Model: MV6-i400WV2GN1
Comes equipped with holes in four The max. allowed level difference

Level difference between IDU~ODU 110m


1-2. Specifications (Return air condition) 2-2. Specifications (Fresh air condition) directions, allowing piping, wire and between IDU and ODU can be 90m
communication cables to be easily (ODU on the top)/110m (ODU at the
IDU air flow (m³/h) 10000 12000 15000 20000 24000 IDU air flow (m³/h) 5000 7000 8000 10000 14000 arranged in any direction. bottom), and the total piping length is
IDU model (modulus) 1212 1215 1515 1521 1821 Model IDU model (modulus) 0915 0915 1212 1215 1518 1340 1000m.
Model

90m
1635
ODU model MV6-i560WV2GN1 MV6-i670WV2GN1 MV6-i850WV2GN1 2*MV6-560WV2GN1 2*MV6-670WV2GN1 ODU model MV6-i560WV2GN1 MV6-i615WV2GN1 MV6-i850WV2GN1 2*MV6-560WV2GN1 2*MV6-615WV2GN1

Rated cooling capacity (kW) 56 67 84 112 134 System Rated cooling capacity (kW) 52 61 82 106 122
System
parameters

850
parameters Rated heating capacity (kW) 60 70 90 120 140 Rated heating capacity (kW) 57 67 88 112 136

Compressor Enhanced vapor injection DC inverter scroll compressor Compressor Enhanced vapor injection DC inverter scroll compressor

Throttling mode Electronic expansion valve Throttling mode Electronic expansion valve
ODU ODU Industry's first multi-channel liquid cooling system(MCLCS) Black box for data backup
Power input (kW) 15.8/15.4 17.8/17.0 22.8/23.2 2*15.8/15.4 2*17.8/17.0 Power input (kW) 15.8/15.4 17.8/17.0 22.8/23.2 2*15.8/15.4 2*17.8/17.0 Front view Side view Top view
Noise value dB(A) 62 64 64 62 62 Noise value dB(A) 62 62 64 62 62 An optional multifunctional small PCB
The V6 VRF uses refrigerant cooling
Refrigerant R410A charge amount (kg) 17 22 25 2*17 2*22 Refrigerant R410A charge amount (kg) 17 17 25 2*17 2*17 Model: MV6-i560WV2GN1, MV6-i615WV2GN1 can be installed on the unit's side
technology to cool the electric control
Connection methods Welding connection Connection methods Welding connection columns, enabling installation and
box. It decreases the average
Connecting pipe Liquid pipe 15.9 19.1 22.2 2*15.9 2*19.1 Connecting pipe Liquid pipe 15.9 15.9 22.2 2*15.9 2*19.1 service engineers to activate
temperature of electrical control
Dimension Dimension Auto-commissioning or check the
Gas pipe 28.6 31.8 35 2*28.6 2*31.8 Gas pipe 28.6 28.6 35 2*25.4 2*31.8 components by about 8 degrees,
operating status without removing the
1340 guaranteeing the stable and safe
front panel. It can also perform
1-3. Specifications (Return air condition) 2-3. Specifications (Fresh air condition) running of the control system.

1635
automatic data backup of the last 30
IDU air flow (m³/h) 15000 16000 17500 19000
minutes' operating record.
IDU air flow (m³/h) 30000 35000 40000

825
IDU model (modulus) 2121 2124 2424 Model IDU model (modulus) 1518 1518 1521 1821
Model
Wide operating range Low noise
ODU model 2*MV6-850WV2GN1 3*MV6-615WV2GN1 3*MV6-670WV2GN1 ODU model 2*MV6-785WV2GN1 2*MV6-850WV2GN1 2*MV6-900WV2GN1 3*MV6-670WV2GN1

Rated cooling capacity (kW) 168 172 200 System Rated cooling capacity (kW) 152 164 180 196 The V6 VRF can operate stably in a wide ambient temperature Night Silent Mode feature which is easily set on the PCB
System
parameters
Front view Side view Top view
parameters Rated heating capacity (kW) 184 188 220 Rated heating capacity (kW) 165 180 198 215 range: from -5°C to 54°C in cooling mode and from -25°C to 24°C board allows the unit to be set to various time options
Compressor Enhanced vapor injection DC inverter scroll compressor Compressor Enhanced vapor injection DC inverter scroll compressor Model: MV6-i670WV2GN1, MV6-i785WV2GN1, MV6-i850WV2GN1 in heating mode. during Non-peak and Peak operation time minimizing the
Throttling mode Electronic expansion valve Throttling mode Electronic expansion valve units noise output.
ODU ODU
Power input (kW) 2*20.6/21.1 3*17.8/17.0 3*18.5/17.6 Power input (kW) 2*20.6/21.1 2*22.8/23.2 2*25/24.8 3*18.5/17.6 -5°C 54°C
Noise value dB(A) 63 63 64 Noise value dB(A) 63 64 64 62
Load
Refrigerant R410A charge amount (kg) 2*25 3*17 3*22 Refrigerant R410A charge amount (kg) 2*22 2*25 2*25 3*22

Connection methods Welding connection Connection methods Welding connection O


Sound

1830
Connecting pipe Liquid pipe 2*22.2 3*15.9 3*19.1 Connecting pipe Liquid pipe 2*22.2 2*19.1 2*19.1 3*19.1
1730 -25°C 24°C level
Dimension Dimension Judgment time Low-noise operation time 10hrs
6hrs
Gas pipe 2*35.0 3*28.6 3*31.8 Gas pipe 2*31.8 2*38.1 2*38.1 3*31.8
Max. 15dB(A) reduction
Notes: Notes: 6:00 12:00 14:00 18:00 20:00 0:00 6:00

850
1. Rated cooling capacity is measured under nominal air flow conditions with an indoor dry bulb/wet bulb temperature of 27/19°C and an outdoor dry bulb/wet bulb temperature of 35/24°C. 1. Rated cooling capacity is measured under nominal air flow conditions with an outdoor dry bulb/wet bulb temperature of 35/28°C. Highest Start End
2. Rated heating capacity is measured under nominal air flow conditions with an indoor dry bulb/wet bulb temperature of 20/15°C and an outdoor dry bulb/wet bulb temperature of 7/6°C. outdoor temp.
3. The equipped electric heater is auxiliary. Therefore, the additional heating capacity required in winter shall be calculated separately. 2. Rated heating capacity is measured under nominal air flow conditions with an outdoor dry bulb/wet bulb temperature of 7/6°C (no frost).
4. Performance test for piping conditions: the equivalent refrigerant pipe is 7.5m long. 3. The equipped electric heater is auxiliary. Therefore, the additional heating capacity required in winter shall be calculated separately. Notes: This function can be activated on site. Temperature (load) curve shown in
5. The ODU carries R410A when delivered from the factory. During installation and based on the liquid pipe length, the correct amount of refrigerant should be added. 4. Performance test for piping conditions: the equivalent refrigerant pipe is 7.5m long; The ODU carries R410A when delivered from the factory. the graph is just an example.
6. Compatible with different type of ODU series. See the manual for specific ODU specifications. During installation and based on the liquid pipe length, the correct amount of refrigerant should be added.
5. Operating temperature: cooling: 20°C to 43°C; heating: -5°C to +16°C. Front view Side view Top view
6. Compatible with different type of ODU series. See the manual for specific ODU specifications.

01 02 03 04