Service Codes – Rational SelfCookingCenter® whitefficiency®
Service 10
What's the cause? SC pump has high water level
Remedy? Drain SC pump hose
Service 11
What's the cause? CDS sensor sending too many pulses
Remedy? See if there is leaking in the level electrode and water path to the steam
generator
Service 12
What's the cause? CDS sensor without signal
Remedy? Check if the CDS sensor's signal is blocked of there is low water pressure
Service 13
What's the cause? Steam generator isn't refilled during steam mode
Remedy? Check the level electrode's 0-1 signal to the PCB
Service 14
What's the cause? Level electrode isn't recognizing water
Remedy? Water conductivity is too low and needs reverse osmosis treatment
Service 16
What's the cause? Old software structure
Remedy?
Service 17
What's the cause? SD card not initialized
Remedy? Clean the existing SD card or use a new one
Service 18
What's the cause? Defective SD card
Remedy? Use a new SD card
Service 19.1
What's the cause? SD card not inserted
Remedy? Insert the SD card
Service Codes – Rational SelfCookingCenter® whitefficiency® 1
Service 20.x
What's the cause? Defective thermocouple
Probes (x):
o 20.1: Cabinet B1 thermocouple
o 20.2: Quenching B2 thermocouple
o 20.4: Humidity B4 thermocouple
o 20.8: Steam generator B5 thermocouple
o COMBINATION OF FAULTY PROBES CAN DISPLAY (EXAMPLE: FAULTY B2
AND B4 THERMOCOUPLES WILL DISPLAY AS "20.6")
Remedy? Replace thermocouple
Service 23
What's the cause? SSR steam short circuit
Remedy? Repair or replace
Service 24
What's the cause? SSR hot air short circuit
Remedy? Repair or replace
Service 25
What's the cause? Improper water flow during CleanJet
Remedy? Check the water pressure, water supply, moistening valve and nozzle and CDS
sensor
BONUS TIP: One of our members, Ectofix, provided a helpful Service 25
troubleshooting sheet to help resolve this issue even further
Service 26
What's the cause? Permanently closed drain valve
Remedy? Replace the drain valve assembly
Service 27
What's the cause? Drain valve won't close during initialization
Remedy? Start the rinse/abort program
Service 28
What's the cause? Thermocouple steam generator B5 temperature is above 356°F
(180°C)
Remedy? Indicator will go off when temperature goes below 230°F (110°C)
Service 29
What's the cause? PCB temperature is above 185°F (85°C)
Remedy? Check the air filter, cooling fan and control panel gasket as well as external
heat sources and air escape openings
Service Codes – Rational SelfCookingCenter® whitefficiency® 2
Service 30
What's the cause? Unit runs in emergency humidity control
Remedy? Humidity control is out of function and needs to be repaired or replaced
Service 31.x
What's the cause? Faulty core probe
Probes (x):
o 31.1: Shaft probe
o 31.2: Fifth probe (near shaft)
o 31.4: Fourth probe
o 31.8: Third probe
o 31.16: Second probe
o 31.32: First probe in tip
o COMBINATION OF FAULTY PROBES CAN DISPLAY (EXAMPLE: FAULTY
FOURTH AND THIRD PROBE WILL DISPLAY AS "31.12")
Remedy? Repair or replace the faulty probe
Service 32.0-1-2
What's the cause? Faulty ignition box
Ignition boxes:
o 32.0: Ignition box top
o 32.1: Ignition box bottom (floor models only)
o 32.2: Both ignition boxes
Remedy? Change the ignition box that appears in error code
Service 33.1-2
What's the cause? Faulty ignition box
Ignition boxes:
o 31.1: Ignition box bottom (floor models only)*
o 31.2: Both ignition boxes
Remedy? Check the ignition wiring or ignition box gas valve and supply
Service 34.xx
What's the cause? Bus signal problems
Probes (x):
o 34.1: Motor top
o 34.2: Motor bottom
o 34.4: Ignition module top
o 34.8: Ignition module bottom
o COMBINATION OF BUS SIGNAL PROBLEMS CAN DISPLAY (EXAMPLE:
IGNITION MODULE TOP AND BOTTOM WILL DISPLAY AS "34.12")
Remedy? See if the bus cable plug and cable connection are connected or damaged
Service Codes – Rational SelfCookingCenter® whitefficiency® 3
Service 35
What's the cause? Bus signal can't be processed due to disconnected ultravent
Remedy? Connect the ultravent
Service 36
What's the cause? Defective differential pressure sensor P1
Remedy? Repair or replace the sensor
Service 37
What's the cause? Differential pressure sensor P1 isn't in expected range
Remedy? Check the connection of hoses
Service 40
What's the cause? Care pump is broken or doesn't fill enough solution into the steam
generator
Remedy? Check if the hose from the care pump outlet isn't kinked and reset error by
completed a successful rinse program
Service 41
What's the cause? Defective solenoid valve Y3, blocked moistening valve or CDS isn't
sending pulses
Remedy? Resolve issue and reset error by completed a successful rinse program
Service 42
What's the cause? Defective solenoid Y4 Care, hose to Care container blocked/kinked
or CDS isn't sending pulses
Remedy? Resolve issue and reset error by completed a successful rinse program
Service 43
What's the cause? Solenoid Y1, Y3 or Y4 is passing water/won't close and CDS is
always sending pulses
Remedy? Reset error by completed an abort program
Service 44
What's the cause? Steam not heating during CleanJet+Care
Remedy? Reset error by completed an abort program
Service 60
What's the cause? Incorrect initialization of ignition box
Remedy? Check the gas settings and switch the unit off and on again before running SD
Repair program
Service Codes – Rational SelfCookingCenter® whitefficiency® 4
Service 63
What's the cause? Self-test running without water
Remedy? Allow the unit to cool down and see if B1, B2 and B4 are below 104°F
(40°C); Set Selftest to ON and switch unit off and on
again before running Selftest
Service 100
What's the cause? Defective SC pump or calcified level electrode
Remedy? Reset error by completed an abort program
Service 120
What's the cause? Defective Care pump M12 or level electrode
Remedy? Reset error by completed an abort program