Method Statement Fisher Plug
Method Statement Fisher Plug
Application
• Hose Reel
• Metal Panel
Meter Panel
Accessories
1.Fischer Threaded Rod M8
2.Injection mortal FIS VS 360S
3.Nozzle extension (Cut to length)
4.Despenser
5.Cone Drill
6.Centring Sleeve
Installation
• Hammer Drill 10mm hole to a depth of 65mm on centerline of fixing position using SDS
drill.
• Remove any debris from the hole. Using blow-out pump.
• Attach mixing nozzle+ extension to cartridge before placing in application gun, discharge
resin until the colour become even. Failure to do this could result in the resin not curing
properly.
DEFIX CONCRETE PRODUCTS SDN BHD (986490-X)
No.8, Jalan PJS 5/26, Taman Desaria
PJS 5, Petaling Jaya
46000 Selangor, Malaysia
TELEPHONE +603-7773 2886 TELEFAX +603-7773 2889
• Inject mixed resin into the hole. Starting with the nozzle at the bottom of the hole and
working outwards. The hole should be approximately 2/3rds filled.
• Immediately after resin is injected into the hole, twist threaded rod into the resin. Make sure
that excess resin emerges from the mouth of the hole as an indication that sufficient resin
has been used. Wipe away any excess while wet or chip off when cured.
• Leave resin to cure completely before applying any load. Curing time is dependent on the
temperature.
• Tighten the nut to the maximum recommended torque of 10Nm using calibrated torque
wrench.
DEFIX CONCRETE PRODUCTS SDN BHD (986490-X)
No.8, Jalan PJS 5/26, Taman Desaria
PJS 5, Petaling Jaya
46000 Selangor, Malaysia
TELEPHONE +603-7773 2886 TELEFAX +603-7773 2889
Application
• Aircond Outer Unit
Fire extinguisher
• Cable
Basin Trunking
OKU & Basin Normal
Installation
Application
• Air cond Inner unit
• Sop & paper Toilet
Installation
Application
• Urinal
• Fire extinguisher
• Basin OKU & Basin Normal
Installation