0% found this document useful (0 votes)
363 views

Method Statement Fisher Plug

This document provides installation instructions for four different fixing anchors: FIS VS360S threaded rod anchor, FUR 10X100 S5 anchor, SX 8 X 40 anchor, and SX 10 X 50 anchor. For each anchor, the document lists suitable applications and step-by-step installation instructions involving drilling holes, inserting the anchor, and screwing in a rod or bolt. The overall document instructs on the proper installation of these mechanical anchors for securing various materials and equipment.

Uploaded by

Chezy629
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
363 views

Method Statement Fisher Plug

This document provides installation instructions for four different fixing anchors: FIS VS360S threaded rod anchor, FUR 10X100 S5 anchor, SX 8 X 40 anchor, and SX 10 X 50 anchor. For each anchor, the document lists suitable applications and step-by-step installation instructions involving drilling holes, inserting the anchor, and screwing in a rod or bolt. The overall document instructs on the proper installation of these mechanical anchors for securing various materials and equipment.

Uploaded by

Chezy629
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

DEFIX CONCRETE PRODUCTS SDN BHD (986490-X)

No.8, Jalan PJS 5/26, Taman Desaria


PJS 5, Petaling Jaya
46000 Selangor, Malaysia
TELEPHONE +603-7773 2886 TELEFAX +603-7773 2889

1.Method Statement Diagram for FIS VS360S with M8


Threaded rod

Application
• Hose Reel
• Metal Panel
Meter Panel

Accessories
1.Fischer Threaded Rod M8
2.Injection mortal FIS VS 360S
3.Nozzle extension (Cut to length)
4.Despenser
5.Cone Drill
6.Centring Sleeve

Installation

• Hammer Drill 10mm hole to a depth of 65mm on centerline of fixing position using SDS
drill.
• Remove any debris from the hole. Using blow-out pump.
• Attach mixing nozzle+ extension to cartridge before placing in application gun, discharge
resin until the colour become even. Failure to do this could result in the resin not curing
properly.
DEFIX CONCRETE PRODUCTS SDN BHD (986490-X)
No.8, Jalan PJS 5/26, Taman Desaria
PJS 5, Petaling Jaya
46000 Selangor, Malaysia
TELEPHONE +603-7773 2886 TELEFAX +603-7773 2889

• Inject mixed resin into the hole. Starting with the nozzle at the bottom of the hole and
working outwards. The hole should be approximately 2/3rds filled.
• Immediately after resin is injected into the hole, twist threaded rod into the resin. Make sure
that excess resin emerges from the mouth of the hole as an indication that sufficient resin
has been used. Wipe away any excess while wet or chip off when cured.
• Leave resin to cure completely before applying any load. Curing time is dependent on the
temperature.
• Tighten the nut to the maximum recommended torque of 10Nm using calibrated torque
wrench.
DEFIX CONCRETE PRODUCTS SDN BHD (986490-X)
No.8, Jalan PJS 5/26, Taman Desaria
PJS 5, Petaling Jaya
46000 Selangor, Malaysia
TELEPHONE +603-7773 2886 TELEFAX +603-7773 2889

2.Method Statement Diagram for FUR 10X100 S5

Application
• Aircond Outer Unit
Fire extinguisher
• Cable
Basin Trunking
OKU & Basin Normal

Installation

• The FUR is suitable for push-through installation.


• Screwing in the screw causes the individual teeth to expand. In solid materials, the teeth
create even expansion forces. In hollow materials, the teeth expand through the solid part of
the block and form an undercut in the cavity.
• With vertically perforated bricks, only use rotary drilling (no impact drilling).
• Recommended for the installation of timber constructions.
• FUR-SS with hexagon head screw or FUR-FUS with hexagon head screw and U-washer is
recommended for the installation of metal constructions.
DEFIX CONCRETE PRODUCTS SDN BHD (986490-X)
No.8, Jalan PJS 5/26, Taman Desaria
PJS 5, Petaling Jaya
46000 Selangor, Malaysia
TELEPHONE +603-7773 2886 TELEFAX +603-7773 2889

3.Method Statement Diagram for SX 8 X 40

Application
• Air cond Inner unit
• Sop & paper Toilet

Installation

• The SX with rim is suitable for pre-positioned installation.


• When turning in the screw, the SX expands in four directions, thus providing a secure
anchoring in the building material.
• The required screw length is given by: Plug length + fixture thickness + 1 x screw diameter.
• Suitable for wood, chipboard and spacing screws fischer ASL.
DEFIX CONCRETE PRODUCTS SDN BHD (986490-X)
No.8, Jalan PJS 5/26, Taman Desaria
PJS 5, Petaling Jaya
46000 Selangor, Malaysia
TELEPHONE +603-7773 2886 TELEFAX +603-7773 2889

4.Method Statement Diagram for SX 10 X 50

Application
• Urinal
• Fire extinguisher
• Basin OKU & Basin Normal

Installation

• The SX with rim is suitable for pre-positioned installation.


• When turning in the screw, the SX expands in four directions, thus providing a secure
anchoring in the building material.
• The required screw length is given by: Plug length + fixture thickness + 1 x screw diameter.
• Suitable for wood, chipboard and spacing screws fischer ASL.