0% found this document useful (0 votes)
188 views8 pages

WEB Configuration Gateway

The document describes a WEB configuration gateway product that allows monitoring of field devices in real-time from mobile phones, pads, and computers. It supports over 200 protocols and integrates with third party systems through open data interfaces. The gateway can collect and monitor data as well as allow configuration of devices remotely through a web browser without additional software.

Uploaded by

Saad Pathan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
188 views8 pages

WEB Configuration Gateway

The document describes a WEB configuration gateway product that allows monitoring of field devices in real-time from mobile phones, pads, and computers. It supports over 200 protocols and integrates with third party systems through open data interfaces. The gateway can collect and monitor data as well as allow configuration of devices remotely through a web browser without additional software.

Uploaded by

Saad Pathan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

WEB Configuration

Gateway

Mobile phone、PAD、
Computer can monitor
configuration pages in real
time.

Open data interfaces are


integrated by third party
systems
WEB Configuration Gateway

WEB Configuration Gateway


1 HMI2004-A9 ..……………………………………..……3
2 HMI2004-A9-GW ..……………………………………..……3

Supported supporte Supported


Model Interfaces
Points d devices Protols
2 ethernets
HMI2004-A9 5120 128 close to 200
4 serial ports
HMI2004-GW
2 ethernet
(With gateway 5120 128 close to 200
4 serial ports
function)

www.bacnetchina.com 2
HMI2004-A9、HMI2004-A9-GW
WEB Configuration Gateway Product mode :HMI2004-A9、HMI2004-A9-GW( With gateway )
Functional description : HMI2004-A9 、HMI2004-A9-GW is WEB configuration Gateway.
Mathching Configuration tool is X2View。WEB Configuration Gateway can realize the data
collection, data real-time monitoring and directly into the configuration screen user configuration
software without having to buy, only need to use PC or any mobile device with browser can access
configuration pages, remote monitoring equipment start-stop operations such as operation, bring
good operational experience to the user At the same time can be forwarded to BACnet IP/MSTP
server or Modbus TCP/RTU server, and open data interface by a third party system integration, and
open data interface by a third party system integration.
Application fields : WEB Configuration Gateway is converted into a standard BACnet
protocol standard Modbus protocol, or SMS alarm project to upload the cloud Applications in building
automation system, smart home, connect some unusual or industry control equipment, such as PLC
elevator fire lighting control system instrument meter, etc So users can through the WEB
configuration screen, or phone 、PAD、PC monitor to the field device
Runtime environment:
OS:Windows XP/Win 7/Win8/Win10/Win Server 2003/Win Server2008/Win Vista etc.

Browser: IE11(and above) 、Safari、Google Chrome、firefox、Opera etc.

Register Type&Num

Number of Registers is dynamic, each register can be builded up to 5120 points.


Supported BACnet type and number are Supported Modbus type and number are
shown below. shown below.
BACnet Register- Modbus Register-
BACnet Register-type Modbus Register-type
number number
0X(Coil Status)
AI(Read only ) 5120(0~5119) 5120(1~5121)
(Read and Write)

AO(Read and Write) 5120(0~5119) 1X(Input Status)


5120(1~5121)
(Read Only)
AV(Read and Write) 5120(0~5119) 4X(Holding Register)
5120(1~10241)
( Read and Write)
BI(Read only ) 5120(0~5119) 3X(Input Register)
5120(1~10241)
(Read only)
BO(Read and Write) 5120(0~5119)
Notes:
1.4X and 3X register address = translocation
BV(Read and Write) 5120(0~5119)
register address *2+1
0X and 1X register address = translocation
MI(Read only ) 5120(0~5119) register address +1
2. The data type of 4X and 3X can only be Float
MO(Read and Write) 5120(0~5119)

MV(Read and Write) 5120(0~5119)

3 www.bacnetchina.com
HMI2004-A9、HMI2004-A9-GW

WEB Configuration Gateway Product mode :HMI2004-A9、HMI2004-A9-GW( With gateway)

Software Features:

-Green and free installation, support both Chinese and


English;

-Support nearly 200 protocols to BACnet server Modbus


server uploads cloud;

-Support SMS E-mail and other communication methods to


send alarm information;

-Support JS script to achieve logical control;

-Support user group management, configuration screen


monitoring can set permissions;

-Supporting historical storage;

-A custom function that supports multiple forms of timer


events to facilitate extended application;

-Support LAN, easy realization of remote viewing and


control of touch screen via mobile PAD PC;

-Add new private protocol support, within 2 weeks;

Hardware Parameter:

CPU:4 core 1.4 GHz POWER:AC/DC 9~24V

Size(L×W×H):
Memory:
142mm×112mm×28mm (Wall-Hanging)
512M high performance memory
142mm×91mm×35mm (Guide Way)

System:LINUX Weight:250g

Watts:8W Material:Aluminum Cover


Setup:
Interface:2 Ethernet
Wall-Hanging(HMI2004-A9-B、HMI2004-A9-GW-B)
4 RS485
Guide Way (HMI2004-A9、HMI2004-A9-GW)
Temperature:-40~85℃(working)
Flash:4G
-40~85℃(storage and transportation)
Network:
Humidity:
1 High-performance 100M/10M adaptive
20% ~ 90%, no condensation (work),
Industrial Network Card, support AUTO
15% ~ 95%, no condensation (storage and transportation)
MDI/MDIX

www.bacnetchina.com 4
HMI2004-A9、HMI2004-A9-GW

Application Principle Diagram

Product Size

HMI2004-A9-B、HMI2004-A9-GW-B(Wall-Hanging) HMI2004-A9、HMI2004-A9-GW(Guide Way)

5 www.bacnetchina.com
Protocols Available for WEB Configuration
Gatways

Protocols Available

Common 26 MBus_EnergerMeter Mbus


1 BACnet IP 27 MBus_EnergyMeter_HaiLin
2 BACnet MS/TP 28 Modbus_HaiLin_EnergyMeter Modbus
3 Modbus RTU
4 Modbus ASCII water meter
5 Modbus TCP 29 MBus_WaterMeter Mbus
6 Modbus UDP 30 MBus_lyglhsb
7 Modbus RTU_TCP 31 ModbusRTU_Zenner Modbus
8 Modbus RTU_UDP 32 MBus_WaterMeter_LXSGY_15E
9 Modbus ASCII_TCP
10 Modbus ASCII_UDP Flow Meter
11 Modbus RTUServer 33 Modbus Kent
12 OPC XML-DA 34 Spirax SARCO M841
13 SNMP 35 SC_FlowMeter
36 Modbus_CNM
Simulation 37 MODBUS_LCD
14 Simulator 38 Modbus_LDZ_6_GuangHua
39 Modbus_BiaoYi_WL
Imported heat meter
15 MBus_EnergyMeter_EN Elevator
16 MBus_Honeywell 40 Hitachi Elevator BA Iterface
17 MBUS_XinTuo 41 Mitsubishi Elevator SMOS-PS2
18 MBus_Landis_Gyr 42 Mitsubishi Elevator KLR-F485
19 MBus_Siemens_FUE950 43 Otis Elevator BA Interface
20 MBUS_MaiTuo 44 ModbusRTU_Otis_BAS
21 MBus_Kamstrup 45 Otis_Elevator_BA_Jen2
22 MBus_HYDROMETER 46 ModbusTCP_Thyssenkrupp_Elevator
47 ModbusRTU_Thyssenkrupp_Elevator
Domestic energy scale 48 Mitsubishi Elevator SMOS-PS2_TCP
23 MBUS_AKE 49 Modbus_Otis_Elevator
24 MBus_YongGang 50 Modbus_Kone elevator
25 MBus_Zenner

6 www.bacnetchina.com
Protocol supported by WEB Configuration of the
gateway

51 Mitsubishi Elevator MAXIEZ 79 Haiwell E/S PLC


52 Mitsubishi Elevator MAXIEZ 80 Haiwell H/N PLC
81 Panasonic FP
Electricity Meter 82 XINJE PLC
53 IEC104 IEC104 83 DELTA_DVP
54 DLT645-1997 84 FATEK_FB
55 DLT645-2007 85 OMRON_FINS_UDP
56 Modbus PM800 86 OMRON_FINS_Serial
57 Modbus IEM3000 87 Saia_SBus_UDP
58 CDT 88 Toshiba_PROVISOR_TC200
59 DLT645-CHINT
60 Modbus_woyat Modbus Siemens PLC
89 Siemens S7-200 PPI
Airconditon 90 Siemens S7-200 Network
61 Toshiba_Airconditioning 91 Siemens S7-300 Network
62 EMERSON_ACM03U1 92 Siemens S7-1200 Network
63 Hisense_Airconditioning 93 XT55 GPS SERVER
64 Joton Tmaster
65 Modbus_DAIKIN_IRACC Lighting control
66 DAIKIN_DRCH-R5 94 KNXnetIP
67 VotonThermostat 95 KNXnetIP_MultiCast
68 SysGreen_Airconditioning 96 DyNet
69 Hitachi_Chiller 97 Modbus LDS
70 SANYO_DG-52GHT 98 MicroPara_DR0816
71 Gree_BaseStationAirconditioning 99 MicroPara_DR1220
100 MicroPara_DH0416
PLC 101 LitePuter_DP_105E
72 Mitsubishi FX1S 102 LitePuter_PLNET
73 Mitsubishi FX2N 103 MicroPara
74 Mitsubishi FX3U 104 ULaiDe
75 Mitsubishi FX_485ADP_485BD 105 LDS
76 Mitsubishi Melsec_Q_Serial 106 E_Linker_ECWG485
77 Mitsubishi Melsec_Q_TCP 107 Lutron_Telnet
78 MEGMEET_MC200

www.bacnetchina.com 7
Protocol supported by WEB Configuration of the
gateway

UPS Other Protocols


108 SANTAK UPS 131 FFU
119 DELTA UPS ES3000 132 Panasonic MINAS A5
110 LEGRAND UPS 133 SINOLY JINE_JA05
111 EMERSON_HIPULSE 134 SAUTER_CASE_VAV
112 EMERSON_Liebert_UPS 135 saj110 _AlarmSystem
113 ModbusRTU_GE_UPS 136 EMEC_LDPH 137 RKC_CH402
114 EKSI_UPS 138 YuDian_AI_Single_loop
139 GreenDaoFenMuJi
Solar Control 140 SOLIN
115 Cibsolar_CA 141 Condair_PH
116 Kaseman GRC TNC-6 142 BIGBANIAN_AIRC800
143 ACTI_SignalSelector
Fire Alarm 144 Modbus_TG01W
117 JB-3208 CRT 145 Ebara_Densan_S-BCS
118 Siemens Cerberus FS18 146 Modbus_HOLTOP_HDK_09S_BA
119 BOSCH_DS7400XI_TCP 147 YeeFung_Parking_System
120 BOSCH_DS7400XI 148 Projector
121 VESDA_Open_HLI_Protocol 149 HeFei_Ahhfat
122 YANRONG_YR_LC_TXAH 150 BoosterBoiler_NEURON_NXQ
123 NOTIFIRE_NFS2_3030_CRT 151 Epson_PJLink

Attemperator
124 LTM9662_485NET M9600
125 SC_HuangMei

Radar
126 Hypersee_Radar
If you would like
127 Hypersee_Alarm_Radar
to know more
Weight products, please
128 Buhler_MEAF pay attention to
129 METTLER_TOLEDO_SICS the wechat
130 YAOHUA_XK3190 public account.

8 www.bacnetchina.com

You might also like