100% found this document useful (1 vote)
250 views4 pages

Masterseal 930/masterseal 933

The document describes MasterSeal 930, a pre-formed elastic bandage for waterproofing joints or cracks. It is bonded using MasterSeal 933 epoxy adhesive. The bandage is suitable for water retaining structures and approved for potable water. Application instructions and details on packaging, storage and handling are provided.

Uploaded by

Paladi Ravi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
250 views4 pages

Masterseal 930/masterseal 933

The document describes MasterSeal 930, a pre-formed elastic bandage for waterproofing joints or cracks. It is bonded using MasterSeal 933 epoxy adhesive. The bandage is suitable for water retaining structures and approved for potable water. Application instructions and details on packaging, storage and handling are provided.

Uploaded by

Paladi Ravi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

MasterSeal 930/MasterSeal 933

Dynamic joint waterproofing bandage and epoxy resin adhesive for rapid return to
service applications
Approved by “the Secretary of State” for use with potable water

DESCRIPTION APPLICATION METHOD


MasterSeal 930 is a highly elastic pre- formed bandage for (a) Surface Preparation
waterproofing over joints or cracks in water retaining Concrete and masonry surfaces should be mechanically
structures, such as reservoirs and water towers, where a high abraded to maximise adhesion. It is essential that all
degree of movement is expected in both vertical and surfaces are clean, free from dust, oil, grease and any other
horizontal applications. The material is suitable for use on a contaminants that may affect the adhesion adversely. All
number of different substrates including concrete, brick, block metal surfaces should be abrasive blasted to SA2½.
and metals. It is bonded to the substrate using MasterSeal
933, a two component epoxy resin adhesive. Prepare an area of substrate around the joint or crack
allowing at least 25 mm to either side of the bandage to be
applied.

Joints or cracks in concrete, brick or block subject to active


water ingress must be prepared and repaired with
MasterSeal 590.

Damaged concrete should be repaired with MasterEmaco S


420.

Allow time for the repair products to cure before proceeding


to the next stage.

Masking the crack or joint


For cracks or joints of less than 25mm in width apply a 25mm
wide masking tape.
For designed joints of more than 25mm in width masking tape
is not always required, in which case the MasterSeal 933
adhesive is applied up to the edge of the joint.
FIELD OF APPLICATION In all cases the edges of the de-bonded area should be
MasterSeal 930 is used to ensure continuity of waterproofing straight and parallel.
over joints or cracks in structures such as:
• Water reservoirs Masking the outer edges of the crack or joint
• Water towers Apply the masking tape to allow a minimum of 5mm to either
• Tunnels side of the MasterSeal 930 bandage.
• Basements
• Filter beds (b) Mixing Adhesive
Use a gate paddle or similar in a slow speed drill to mix
FEATURES AND BENEFITS MasterSeal 933 Part B (hardener) for 30 seconds, before
• 3 day return to service at ≥ 14°C adding to MasterSeal 933 Part A (resin) and mix for a
• 10 day return to service at ≥ 7°C minimum of 2 minutes until a homogenous mixture of a
• Proven high performance uniform grey colour is achieved. This should happen within
• Reg 31 approved for contact with potable water four minutes. Do not part mix; the materials have been
• Can be applied in damp conditions correctly packaged to the proportions required.
• Resistant to UV light, ozone and a wide range of
chemicals As with all epoxy resins, an exothermic reaction between the
• Suitable for horizontal and vertical joint/cracks two components generates heat. It is essential, therefore to
• Low adhesive consumption use the mixed material as soon as possible.
• No solvent wipe required
(c) Application
Do not apply to frozen substrates or if the ambient
TESTS AND APPROVALS
temperature is below 5°C or expected to fall below 5°C within
Approved by the Secretary of State for the Environment
24 hours.
under Regulation 31(4)(a) for use with potable water.
With a clean spreader, suitable trowel or brush, apply
Specific instructions for use available on request.
MasterSeal 933 adhesive between the masking tapes to a

Page 1 of 4
Date of Issue: September 2015
Version No. 2
MasterSeal 930/MasterSeal 933
Dynamic joint waterproofing bandage and epoxy resin adhesive for rapid return to
service applications
Approved by “the Secretary of State” for use with potable water

depth of 1- 2mm. Remove the central masking tape (if used) CLEAN UP AND STORAGE
immediately on completion. Immediately after use all tools and equipment can be cleaned
using a suitable solvent. Please note the solvent should not
Centrally position the MasterSeal 930 bandage onto the be used in a confined space or where spillages could come
MasterSeal 933 adhesive pushing it firmly with a spatula, or into contact with potable water.
trowel, to remove trapped air and ensure full contact.
Hardened adhesive can only be removed mechanically.
Run a straight edge down the sides of the bandage to ensure
a full bond. Overlap the edges of the bandage with 5mm of In reservoir applications wipe clean with a clean, lint free,
MasterSeal 933 adhesive applied at a depth of 1-2 mm to cloth and potable water only. Repeat as necessary.
encapsulate the edges of the bandage. Remove the masking
tapes and clean off all excess adhesive from surrounding
areas. STORAGE
All materials are to be stored under cover, clear of the ground
Where required the MasterSeal 930 bandage can be joined in dry, frost-free conditions. Rolls of MasterSeal 930 bandage
by heat welding. Ensure a minimum overlap of 25mm. must be stacked on end no more than 4 boxes high.

CURING SHELF LIFE


Full hardening of MasterSeal 933 adhesive is generally Rotate stock in order not to exceed the shelf life of 12 months
achieved after 2 to 3 days dependent upon the ambient for adhesive and 24 months for bandage.
temperature.
HANDLING AND TRANSPORT
For information on return to service times for potable water Usual preventive measures for the handling of chemical
applications see the cure curve data on the table below.
products should be observed when using this product, for
example do not eat, smoke or drink while working and wash
PACKAGING
hands when taking a break or when the job is completed.
MasterSeal 930 bandage is available in the following widths
and thickness: Specific safety information referring the handling and
100mm (wide) x 1mm (thick) x 20m (length) transport of this product can be found in the Material Safety
150mm (wide) x 1mm (thick) x 20m (length) Data Sheet. For full information on Health and Safety matters
200mm (wide) x 1 mm (thick) x 20m (length) regarding this product the relevant Health and Safety Data
200mm (wide) x 2mm (thick) x 20m (length)
Sheet should be consulted.
MasterSeal 933 adhesive is a 2-component, 5 kg unit. Disposal of product and its container should be carried out
according to the local legislation in force. Responsibility for
COVERAGE this lies with the final owner of the product.
Bandage width Linear metres per kg
100mm 3.5 - 7.0 metres CONTACT DETAILS
150mm 2.6 – 5.2 metres BASF plc,
200mm 1.7 - 3.5 metres
Construction Chemicals,
Bandage width Linear metres per 5 kg pack 19 Broad Ground Road
100mm 17.5 - 35.0 metres Lakeside
150mm 13.0 - 26.0 metres Redditch
200mm 8.4 - 17.5 metres Worcestershire
Bandage width Adhesive per 1 metre length of B98 8YP
bandage Tel: +44 (0) 1527 512255
100mm 0.15 - 0.3 kg Fax +44 (0) 1527 503576
150mm 0.22- 0.45 kg www.master-builders-solutions.basf.co.uk
200mm 0.30 - 0.6 kg

A 5kg pack yields approximately 3.6 litres of adhesive. © BASF plc, Construction Chemicals
Coverage will vary dependent upon substrate profile and
condition.

Page 2 of 4
Date of Issue: September 2015
Version No. 2
MasterSeal 930/MasterSeal 933
Dynamic joint waterproofing bandage and epoxy resin adhesive for rapid return to
service applications
Approved by “the Secretary of State” for use with potable water

Product Data
Property Unit Data
Colours – MasterSeal 933 adhesive & MasterSeal
Light Grey
930 Bandage

MasterSeal 933 Adhesive

Density of mixed material kg/m3 Approx. 1400

Mixing time minutes Approx. 2

minutes
Working time 30 (+20ºC)

Adhesion to concrete N/mm2 ≥ 3.0

MasterSeal 930 Bandage

400 (1 mm thickness)
Elongation at break %
500 (2 mm thickness)

24.0 (1 mm thickness)
Tear resistance N
40.0 (2 mm thickness)

MasterSeal 930/933 Return to Service Cure Curve

Page 3 of 4
Date of Issue: September 2015
Version No. 2
MasterSeal 930/MasterSeal 933
Dynamic joint waterproofing bandage and epoxy resin adhesive for rapid return to
service applications
Approved by “the Secretary of State” for use with potable water

MasterSeal 930/MasterSeal 933 - BASF plc, Construction Chemicals, Version 2

Health and Safety Spillage


*For full information on Health and Safety matters regarding this product the Chemical products can cause damage; clean spillage immediately.
relevant Health and Safety Data Sheet should be consulted.
DISCLAIMER
The following general comments apply to all products. “BASF plc, Construction Chemicals" (the Company) endeavours to ensure that
advice and information given in Product Data Sheets, Method Statements and
As with all chemical products, care should be taken during use and storage to Material Safety Data Sheets (all known as Product Literature) is accurate and
avoid contact with eyes, mouth, skin and foodstuffs, (which may also be tainted correct. However, the Company has no control over the selection of its products
with vapour until the product is fully cured and dried). Treat splashes to eyes for particular applications. It is important that any prospective customer, user or
and skin immediately. If accidentally ingested, seek medical attention. Keep specifier, satisfies him/her-self that the product is suitable for the specific
away from children and animals. Reseal containers after use. application. In this process, due regard should be taken of the nature and
composition of the background/base and the ambient conditions both at the time
Solvent Based Products of laying/applying/installing the material and when the completed work is to be
Use in well ventilated areas; avoid inhaling. Suitable respiratory equipment may brought into use.
be needed, eg when spraying. Can cause skin, eye irritation. Wear protective
eye shields and gloves during use. Do not smoke or allow sparks or naked lights Accordingly, no liability will be accepted by the Company for the selection, by
when stored or in use. others, of a product, which is inappropriate to a particular application.

Resin Products Products are sold subject to the Company's standard conditions of sale and all
Can cause irritation, dermatitis or allergic reaction. Use protective equipment customers, users and specifiers, should ensure that they examine the
particularly for skin and eyes. Use only in well ventilated areas. Company's latest Product Literature.
® = registered trademark of BASF group in many countries

Page 4 of 4
Date of Issue: September 2015