100% found this document useful (3 votes)
1K views1 page

Brosur TAL JEC 3406 - Rev27

This document provides specifications for Thermal Aluminium Conductor (TAL), including its technical properties, sizes available, calculated cross-sectional area and weight, breaking load, DC resistance, current carrying capacity, and standard length per reel. TAL has sizes ranging from 240 mm2 to 2500 mm2. It lists the number of wires, diameter of each wire, and other calculated measurements for each size. It also provides notes on ambient temperature, continuous operating temperature, wind velocity, and conductivity of TAL.

Uploaded by

Muhammad Yusuf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (3 votes)
1K views1 page

Brosur TAL JEC 3406 - Rev27

This document provides specifications for Thermal Aluminium Conductor (TAL), including its technical properties, sizes available, calculated cross-sectional area and weight, breaking load, DC resistance, current carrying capacity, and standard length per reel. TAL has sizes ranging from 240 mm2 to 2500 mm2. It lists the number of wires, diameter of each wire, and other calculated measurements for each size. It also provides notes on ambient temperature, continuous operating temperature, wind velocity, and conductivity of TAL.

Uploaded by

Muhammad Yusuf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TAL

TAL
Thermal Aluminium Conductor
Standard Specification : JEC 3406 : 2010

Thermal Aluminium

Technical Properties
Calculated Approx. Calculated DC Resistance Current Standard
Number / Dia. Approx.
Size Cross Sect. Overall Breaking at 20° C Carrying Length
of Wire Weight
Area Diameter Load Max. Capacity * per Reel

mm² No. / mm mm² mm kg/km kN Ohm/km A m


240 19 / 4.0 238.8 20.00 654 34.2 0.122 897 2,000
400 37 / 3.7 397.8 25.90 1,097 58.0 0.0737 1,258 2,000
510 37 / 4.2 512.6 29.40 1,413 73.3 0.0571 1,491 2,000
660 61 / 3.7 655.9 33.30 1,812 95.6 0.0448 1,753 2,000
850 61 / 4.2 845.1 37.80 2,334 120.9 0.0342 2,073 2,000
980 91 / 3.7 978.4 40.70 2,716 142.7 0.0302 2,272 1,000
1030 91 / 3.8 1032.0 41.80 2,865 150.5 0.0286 2,353 1,000
1260 91 / 4.2 1260.8 46.20 3,499 180.3 0.0234 2,672 1,000
1600 127 / 4.0 1595.9 52.00 4,438 228.5 0.0186 3,083 1,000
2020 127 / 4.5 2019.8 58.50 5,617 289.0 0.0147 3,540 500
2500 127 / 5.0 2493.6 65.00 6,935 357.0 0.0118 3,988 500
*Note :
Ambient temperature : 40o C Continuous operating temperature of conductor : 150°C
wind velocity : 0.5 m/sec Conductivity of TAL : 60% IACS

20430-00 Rev. 1.0 / 2014