0% found this document useful (0 votes)
377 views13 pages

Pump Series D-H-M-HD-PGH Parker

A Parker fixed displacement gear pump consists of two intermeshing hardened steel gears enclosed by die cast aluminum covers and a center section. The gears are precision ground and shrink fitted onto drive and driven shafts. Pressure loading of the gears from inlet pressure increases efficiency by reducing internal leakage. Rotation causes the gear mesh to increase on the inlet side and decrease on the outlet side, pumping fluid from inlet to outlet. Performance data is provided showing flow rates in gallons per minute for various models over a range of RPMs and pressures.

Uploaded by

Daniel Mar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
377 views13 pages

Pump Series D-H-M-HD-PGH Parker

A Parker fixed displacement gear pump consists of two intermeshing hardened steel gears enclosed by die cast aluminum covers and a center section. The gears are precision ground and shrink fitted onto drive and driven shafts. Pressure loading of the gears from inlet pressure increases efficiency by reducing internal leakage. Rotation causes the gear mesh to increase on the inlet side and decrease on the outlet side, pumping fluid from inlet to outlet. Performance data is provided showing flow rates in gallons per minute for various models over a range of RPMs and pressures.

Uploaded by

Daniel Mar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Fixed Displacement Gear Pumps

Introduction Series D/H/M/HD

General Description
Rotary
Hardened, ground shaft.
shaft seal,
. /
Gear

+eat Shield -
High strength aluminum
‘&At \ I Wearplatel ~“ ~ ~ center section.
II ‘.
/ II
4
/

‘- Heavy duty bronze-on-steel


Wustplate.

-~ Independent parting line O-Rings


ensures positive sealing.
---
G \
Die cast front cover of strength die cast
heavy duty aluminum Iinum rear cover.
alloy. / x%!...%,

Loading members designed to maintain high ~ = \,: ~ ‘~ \


efficiency throughout full pressure range L
and compensate for internal wear. IA.-’. i V)s

Driven Gear
Special designed sleeve bearings in the Front and Rear Cover,
for high load, long life, lower noise level and exceptional
resistance to contamination.

A Parker pressure loaded gear pump consists of two The phenolic heat shield, backup gasket, and molded
intermeshing, hardened steel, precision ground gear rubber seal form chambers behind the steel backed
assemblies, These precision gears are enclosed by a bronze wearplate. These chambers are connected either
high strength, die cast aluminum front cover, back to inlet or discharge pressure. Discharge pressure,
cover and a high yield strength extruded aluminum acting within the chambers, axially loads and deflects the
center section. wear plate toward the gear faces to take up gear side
clearances. This pressure loading on the wear plate
Gear assemblies consist of one drive gear shrink fit increases pump efficiency by reducing internal leakage
on precision ground and polished drive shaft. This shaft to a minimum, providing longer pump life.
extends outside the pump to permit coupling to an
external prime mover by means of a standard key way. Pump rotation is dependent on proper orientation of the
The second gear being the driven gear is also shrink heat shield, backup gasket, and rubber seal in the front
fit on a precision ground and polished driven shaft, cover housing, the center section and rear cover oriented
Retaining rings installed in grooves provided on the shaft respectively.
ensure that the gears will not move axially and a key
keeps the drive gear from moving radially. Pumping action is achieved by connecting the pump
drive shaft to a prime mover and rotating the gears away
A lip type shaft seal is provided at the drive shaft to pre- from the inlet port. Rotation causes the gear mesh to
vent external leakage of pump fluid. The sealing lip in increase on the inlet side and decrease on the outlet
contact with the fluid is spring loaded. Vent passages (pressure) side.
within the housings and driven shaft communicate
pump inlet pressure to the rotary seal area, thus im-
posing the lowest possible pressure at the rotary seal for
extended seal life.

For additional information - call your local


12 Parker Fluidpower Motion & Control Distributor.
Fixed Displacement Gear Pumps
Technical Information Series D

Performance Data
Data Based on 100 SSU
Flow In Gallons Per Minute – GPM (LPM) Viscosity Fluids at 120°F (49”C)

w
1
Pump Displacement 1500 Psl 2000 Psi !500 Psl
RPM
Model IN3 (CC/REV.) (103 Bar) (138 Bar) 172 Bar)
.42 .37 .32
1200
(2.20) (1.82) (1.59) (1.40) (1.21)
.87 .77 .71 .66 .61
D05 .114 (1.87) 1800
(3.30) (2.92) (2.69) (2.50) (2.31)
1.73 1.65 1.61 1.56 1.52
3600
(6.56) (6.25) (6.10) (5.91) (5.76)
.85 .73 .68 .62 .56
1200
(3.22) (2.77) (2.58) (2.35) (2.12)
1.26 1.16 1.10 1.05 .99
D07 .168 (2.76) 1800
(4.85) (4.40) (4.17) (3.98) (3.75)
2.56 2.47 2.42 2.37 2.33
3600
(9.70) (9.36) (9.17) (8.98) (8.83)
1.06 I .94 I .87 .81 .75
1200
(4.02) I (3.56) (3,30) (3.07) (2.84)
1.41 1.35 1.29

M
D09 .210 (3.45) 1800
(5.34) (5.12) (4.89)
3.04 2.99 2.94
3600
(1 1.52) (11.33) (11.14)
1.32 1.19 1.12 1.06 .99
1200
(5.00) (4.51) (4.24) (4.02) (3.75)
1.99 1.86 1.79 1.73 1.66
Dll .262 (4.29) 1800
(7.54) (7.05) (6.78) (6.56) (6.29)
3.97 3.86 3.81 3.76 3.70
3800
(15.05) (14.63) (14.44) (14.25) (14.02)
1.66 1.52 1.44 1.37 1.30
1200
(6.29) (5.76) (5.46) (5.19) (4.92)
2.49 I 2.35 I 2.27 2.20 2.13
D14 .329 (5.38) 1800
(9.44) I (8.91) I (8.60) (8.34) (8.07)
4.99 I 4.88 I 4.82 4.76 4.70
3600
(18.91) (18.50) (18.27) (18.04) (17.81)
2.04 1.88 1.80 1.72
1200
(7.73) (7.13) I (6.82) (6.52) ;672)
2.83 2.75 2.67

%2--k&
D17 .404 (6.62) 1800
(10.73) (10.42) (10.12)
5.95 5.88 5.82
3600
(22.55) (22.29) (22.06)
2.64 2.46 2.37 2.28 2.19

d=
1200
(10.00) (9.32) (8.98) (8.64) (8.30)
3.97 3.79 3.70 3.61 3.52
D22 .522 (8.55) 1800
(15.05) (14.36) (14.02) (13.68) (13.34)
7.93 7.79 7.71 7.64 7.57
3600
(30.05) I (29.52) (29.22) (28.96) (28.69)
3.25 I 3,05 I 2.95 2.85
1200
(12.32) (11.56) I (11.18) (10.80)
4.87 I 4.67 4.57 4.47
D27 .641 (10.50) 1800
(18.46) (17.70) I (17.32) (16.94)
8.12 7.96 7.88 7.80
3000
(30.77) (30.17) (29.86) (29.56)

For additional information - call your local


14 Parker Fluidpower Motion & Control Distributor.
Fixed Displacement Gear Pumps
Technical Information Series D

Performance Data

Based On Oil Temperature of 120eF (49”C)


(100 SSU) Atmospheric Inlet

D05, D07
D07 3.0
6.0 (11.4) 100Psl
2500 PSI (6.9 Bar)
(172 Bar)
2600 PSI ’07
2.5 (172 Bar)
5.0 (9.5)

cc D05
w 2500 PSI 2.0 / 100 Psl
~ 4.0 (7.6)
(172 Bar)
‘6”9 ‘ar) D05
n- 2500 PSI
IJJ (172 Bar)
cl) / 1.5
c 3.0 { (5.7) {
0 D07
I 1000 Psl
1- (69 Bar)
3 / 1.0 /
~ 2.0 T / x D05 (3.6)
z /
1000 Psl
(69 Bar)
/ / D07 0.5
1.0 100 PSI (6.9 Bar) (1.9) /
~ D05
100 PSI (6.9 Bar)
,
1000 2000 3000 4000 20C4) 3000 4

SPEED (RPM) SPEED (RPM)

D09, Dll
4.50 100 Psi
9.0 (17.1) (6.9 Bar)
D11
D11 2500 PSI
(172 Bar)
3.75 A
7.5 (14.2) 100 Psl
(6.9 Bar)
D09
2500 PSI
3.00 (172 Bar)
6.0 , (11.4)

2.25
4.5 (8.5)

1000 PSI (69 Bar)


1.50 /
3.0 - r (5.6) “
1000 PSI (69 Bar)

/ 5 .75
1.5 (2,8)
100 PSI (6.9 Bar)
+ @ D09
~ 100 PSI (6.9 Bar)
1000 2000 3000 4000 1000 2000 3000 4000

SPEED (RPM) SPEED (RPM)

Hydraulic Pump/Motor Division


Otsego, Ml 49078
Motion&Control 15
Fixed Displacement Gear Pumps
Technical Information Series D

Performance Data

Based On Oil Temperature of 120 ‘F (49”C)


(100 SSU) Atmospheric Inlet

D14, D17

12.0 D17 9.0


(34.1) 1
2500 PSI
(172 Bar)

10,0
D14 7.5 100 Psl
2500 PSI (26.4) (6.9 Bar)
(172 Bar) D17
K
~ 8.0 / / 6.0
(22.7)
n
D14
Y 4,5
m 6.0
D17 (17.1)
g
1000 PSI (69 Bar)
1- D14
~ 4.0 3.0
1000 PSI (89 Bar) (11,4)
z—

2,0 1,5
D17
100 PSI (6.9 Bar)
D14
100 PSI (6,9 Bar)
1000 2000 3000 4000 1000 2000 3000 4000
SPEED.(RPM) SPEED(RPM)

D22, D27
m..
uLt 9.0 100 Psl
15.0 -
(34,1) I

F
D27 ‘6”9 ‘ar) D22
2500 PSI
(172 Bar)
/ 7.5
(138 Bar) (28.4)
100 Psl
u (6.9 Bar) D27
u
~ 10.0 / ‘ s
~
6.0
(22.7)
2000 Psl
(136 Bar)
J
n
{ :
4.5
/ D27 y (17.1)
o D22
x 1000 Psl
(69 Bar) 1000 Psl ~
1- (69 Bar)
3 A
& 5.0 ii (11347
~ /

/ D27 1,5
/ 100 Psl (5.7)
(6.9 Bar) D22
100 Psl
- (6.9 Bar) ‘k
1000 2000 3000 4000 1( o 2000 3000 4000
SPEED(RPM) SPEED (RPM)

For additional information - call your local


16 Parker Fluidpower Motion & Control Distributor.
Fixed Displacement Gear Pumps
Technical Information Series D

Dimensions — 2 Bolt Mounting


Millimeter equivalents for inch dimensions are shown in (**)

Clockwise Rotation and “A” Shaft Shown


(Port locations reverse for CCW rotation)

MTG.HOLE
.392(9.96)DIA.THRU
2-HOLES
7 WOODRUFF KEY A L .42 (10.67) FLANGE
2.000(50.80)~lA. .125 (3.175) WIDE X
1.998(50.75) .625 (15.88) DIA.
t- l\
,50
(12.70)

,L
t
( .500 (12.70) —— —
,499 (12.67)

! 58

—(;9:2+——— &y&, -----4


~ 3.25 ~
(82.55)

FRONT VIEW SIDE VIEW

IN LET

k?+-%i

REAR VIEW

CIA” Dimensions: Inches (ITlfll)


. .
D05 D07 D09 D11 D14 D17 D22 D27

2.48 2.57 2.64 2.72 2.83 2.96 3.15 3.34


(62.99) (65.28) (67.06) (69.09) (71.88) (75.18) (80.01) (84.84)
,

Hydraulic Pump/Motor Division


Otsego, Ml 4907’8
Motion &Contml 17
Fixed Displacement Gear Pumps
Technical Information Series D

Dimensions — 4 Bolt Mounting


Millimeter equivalents for inch dimensions are shown in (**)

Clockwise Rotation and “A” Shaft Shown


(Port locations reverse for CCW rotation.)

01)
55)
KEYSHAFT
WOODRUFF KEY
“125 WIDE X “625 DIA.
(15.88)
(3.175)
7’I
Tmm”” -
1.781 (45.24)
1.779 (45.19) ~“’ - - ,-

‘~” ‘ri’ ~ . _ -
.50

‘1K
(12.70)
.500 (12.70)
.499 (12.67)
DIA. .133 (3.36)
.093 (2.36)
1.005

L
7
.995
2.005 (50.93) “’q..(,:,::,,-s
1.995 (50.67)
~1.375TYP.
(34.93)
— 2“750 TYP.
SIDE VIEW
(69.85)

FRONT VIEW

Ou

~jJ-J--+--+j El

Dimensions: Inches (mm)


. .
D05 D07 D09 D11 D14 D17 D22 D27

3.22 3.31 3.38 3.47 3.58 3.70 3.90 4.09


(81.79) (84.07) (85.85) (88.14) (90.93) (93.98) (99.06) (103.89)

“S” Tang-end Shaft Option — For Use With 4 Bolt Mounting


Primarily used to direct couple to electric motor drive.

TANG WIDTH t-(Qe~~’)1 (J+ ‘E’ .5,, ~,A MM COUPLING l-+;:,


ON SHAFT (14.35) “
.148 (3,76)
.146 —.
(3.71) +

) cOupL’NGK’Tp’N8:GEsHA” (4) MOUNTING BOLTSAND WkHERS

For additional information - call your local


18 Parker Fluidpower Motion & Control Distributor.
Fixed Displacement Gear Pumps
Technical Information Series D

Dimensions — 2 Bolt Mounting


(With “L” Back Cover For Tank Mounting)
Millimeter equivalents for inch dimensions are shown in (*•)

Counterclockwise Rotation and “A” Shaft Shown


(Pump mounting flange opposite side of back cover
centerline for CW rotation.)

RELIEF VALVE ASS’Y 666051


~BACK COVER ASSY
r

/-Txi!!””A”
/
\ I A

1/ ,50
(12i70)
)

I 1.625 \

---
\.= (9.65)

.531
(1349)-
m’-
10” ----
R, TYP.

OF DHIVk
..-
O-RING

FRONT VIEW SIDE VIEW

I ++ 8 UNC-2B

-lM

~ ’34X 143 WASHER (2 REO’D)

~ INLET PORT
1/2 N. P.T.F.

REAR VIEW

“A” Dimensions: Inches (mm)


D05 D07 D09 D11 D14 D17 D22 D27

3.39 3.48 3.55 3.75 3.87 4.06 4.26


(86.11) (66.39) (90.1 7) (;2!%6) (95.25) (98.30) (103.12) (108.20)

Hydraulic Pump/Motor Division


Otsego, Ml 49078
Fixed Displacement Gear Pumps
Technical Information Series D

Dimensions — 4 Bolt Mounting


(With “L” Back Cover For Tank Mounting)
Millimeter equivalents for inch dimensions are shown in (’*)

Clockwise Rotation and “A” Shaft Shown


(Pump mounting flange opposite side of back cover
centerline for CCW rotation.)

2.750
(69.65
1.375
(34.93

“A$*

D05 D07 D09 D11 D14 D17 D22 027

4.14 4.23 4.30 4.39 4.50 4.62 4.81 5.01


(105.16) (107.44) (109.22) (111.51) (114.30) (117.35) (122.17) (127.25)

“R” Tang-end Shaft Option — For Use With 4 Bolt Mounting


Primarily used to direct couple to electric motor drives.

’75 DIA. MAX. COUPLING P(’::8)


(19.05)
SHAFT
.250
(6.35)
O!lj

.244 “25 TANG


(6.35)
(6.20)k
COUPLING KIT P/N 625367K
KIT INCLUDES (1) COUPLING,
(4) MOUNTING BOLTSAND WASHERS

For additional information - call your local


20 Parker Fluidpower Motion & Control Distributor.
Fixed Displacement Gear Pumps
Technical Information Series D

Dimensions — Accessories For “L” Back Cover Pump


Millimeter equivalents for inch dimensions are shown in (**)

Sub-Plate for Supply, Return and Gage Ports —


Kit No. 735555K
H-(I:L, (:s-i k[:r:;:FmRT

Tt.!4 (
(M 10)

Note: Kit includes: (1) sub-plate, (4) mounting bolts, (3) O-rings, (1) plug

Sub-Plate For Mounting (NFPA DO1) Directional Control Valve —


Kit No. 825602K
*(:,~5)+

1(’28T---
~“’w=n”’”’”o’
,08 x 4 PL (
(8L1ND) 7(1624 UN
SAEWON )

I\ ’A” h t
,60 (4.M,~A /
22,5 59)DEEP PORT–.2SS
(635)
\
I
2BTHDx 42(10.65)
(0% DEEP-4HOLES

&,;,y5,+5& (s3,, ma.


PRESS”!+PORT
2S4{635)D,A

Note: Kit includes: (1) sub-plate, (4) mounting bolts, (3) O-rings, (1) plug

Tanks (Hydraulic Reservoir)


2-Quart Capacity Tank — Kit No, 715631
“B” Dimension 4.67 (1 18.62) inches

4-Quart Capacity Tank — Kit No. 715632


“B” Dimension 10.17 (258.32) inches

6-Quart Capacity Tank — Kit No. 735560


“B” Dimension 14.17 (359.92) inches

,,
Note: Kit includes: (1) reservoir assembly, (1) suction strainer, (1) filler cap.

Hydraulic Pump/Motor Division


Otsego, Ml 49078
21
Nitrile
Fluoroelastomer