Instrumentation Engineering Sample Questions
Instrumentation Engineering Sample Questions
Questions And Answers
No. Question
A surface height profile is given by, y = a + b sin
2π x
l
1
(0 x l) where a, b, l are constants and x is the horizontal coordinate. The
roughness of the surface, based on absolute deviation, is
A) B)
2b
π π
Options C) D)
6b
π π
Correct
A
Answer
For N-bit Successive Approximation ADCs, other parameters such as clock frequency
2 remaining constant, the conversion time is proportional to
B)
A) N 2
√N
Options
C) log N D) N
Correct
B
Answer
3 The radius of a sphere is given as (40.0 ± 0.5)mm. The estimated error in its mass is:
A) ± 3.75% B) ± 1.25%
Options C) ± 12.5% D) ± 0/125%
Correct
B
Answer
4 A zero error in a vernier caliper is termed as
A) accidental error B) interference error
Options C) systematic error D) random error
Correct
B
Answer
5 Given the discrete-time sequence x[n] = [2, 0, -1,-3, 4, 1, -l, X(ejπ) is
A) 8 B) 6π
Options C) 8π D) 6
Correct
C
Answer
6 Linear variable differential transformer has
A) two primary coils connected in phase B) two primary coils connected in opposition
and a secondary coil and a secondary coil
Options C) one primary coil and two secondary D) one primary coil and two secondary coils
coils connected in phase connected in opposition
Correct
D
Answer
Position sensor units having a constant sensitivity of lV/mm are used for feedback in
number of position controlled system units, each having an overall forward path dc
gain of 50. If the random dc bias errors in the outputs of various sensor units are
7 characterized as normal with mean 0 and standard deviation (σ) 0.01V, for a constant
set point of 5V, the true position outputs of the various controlled system units can be
characterized as normal with
A) mean of 5.0, σ of 0.01 B) mean of 0.0, σ of 0.01
Options C) mean of 5.0, σ of 0.0098 D) mean of 4.902, σ of 0.0098
Correct
C
Answer
The refractive index of the core of an optical fiber is n1and that of the cladding is nf If
8 (n1 – n2) = ∆n, then the fiber can be made single mode with numerical aperture
unchanged by
B) reducing both core diameter and ∆n
A) reducing core diameter and increasing ∆n
Options C) reducing core diameter alone
D) reducing ∆n alone
Correct
D
Answer
For a suppressed carrier amplitude modulator (AM-SC) system, the carrier and the
9 modulating inputs are xc (t) = cos ωc t and xm (t) = 0.5 sin ωm t, respectively. The output
of the system is proportional to
A) sin (ωc + ωm) t – sin (ωc - ωm) t B) sin (ωc + ωm) t + cos (ωc -ωm) t
Options C) (1 + 0.5 sin ωm t) cos ωc t D) (1- 0.5 sin ωm t) cos ωc t
Correct
B
Answer
The 3-dB cut-off frequency of a first analog high pas filter is ωc the output will have a
10
phase shift of
A) B)
-π
2 4
Options C) D)
π
2 2
Correct
B
Answer
11 In an INTEL 8085 microprocessor the ADDRESS-DATA bus and the DATA bus are
A) Non multiplexed B) Multiplexed
Options C) Duplicated D) Same as CONTROL bus
Correct B
Answer
A 3 ½ digit nultimeter has an accuracy specification of (± 0.5% of reading ± 5 counts).
12 If the meter reads 2.00 mA on a full scale of 20mA, the worst-case error in the reading
is
B) 2.5%
A) 0.5%
Options D) 5.5%
C) 3.0%
Correct
C
Answer
The measurements of a source voltage are 5.9V, 5.7V and 6.1V. The sample standard
13
deviation of the readings is
A) 0.013 B) 0.04
Options C) 0.115 D) 0.2
Correct
D
Answer
Consider the following systems:
System 2: G(s) =
1
2(2s+1
)
14 System 1: G(s) =
1
2(5s+1
)
The true statement regarding the system is
A) Bandwidth of system 1 is greater than B) Bandwidth of system 1 is lower than
the bandwidth of system 2 the bandwidth of system 2
Options C) Bandwidth of both the systems are the D) Bandwidth of both the systems are
same infinite
Correct A
Answer
The transfer function of a system is
A
15 s2 + ω2
The steady-state gain of the system to a unit-step input is
A)
A
ω2
B) 0
Options
C) ∞ D) not possible to be determined
Correct
C
Answer
16 In 8085 microprocessor, CY flag may be set by the instruction
A) SUB B) INX
Options C) CMA D) ANA
Correct
A
Answer
V1 and V2 are the input voltages of an instrumentation amplifier. The output of the
instrumentation amplifier is found to be 100(V1 – V2) + 10-4 (V1 + V2). The gain and
17
the common mode rejection ratio (CMRR) of the instrumentation amplifier
respectively are
A) (50, 60 dB) B) (50, 120 dB)
Options C) (100, 60dB) D) (100, 120 dB)
Correct
C
Answer
18 The sequence x[n] whose z-transform is X[z] = e(1/Z) is
Options A) B)
1 1
n! -n!
u[n] u[-n]
C) (-1)n D)
1 1
n! -(n+1)!
u[n] u[-n-1]
The time taken by an ionized atom, of mass m kg and charge e Coulombs, pulsed into
19
a field-free region with V volts, to reach a detector L meters away is
A) B)
1
L
L
m m
2eV 2eV
√ √
Options D)
C) m 2
L L
2eV m
√ 2eV
√
Correct
B
Answer
The clock frequency of a timer-counter is 10MHz. The timer-counter is used in the
20 period mode and the input to the timer-counter is a square wave of frequency 2 kHz.
The display of the timer-counter will show a value
A) 200 B) 2000
Options C) 5000 D) 50000
Correct
C
Answer