Anc Storm Valve
Anc Storm Valve
400
UNIT NO. 682
PN. 682-10 & 20
DATE 26-Jul-2002
Features
! Valve closes automatically when disconnecting the running string
! Valve equalizes automatically when reconnecting running string
! Expendable plug for through-bore access
! Rugged alloy-steel construction
! Tool-joint connections
Benefits
! Simple to operate
! Compatible with compression packer operation
! Dependable design
! Easy to redress
Applications
! Weather-related emergencies
! Wellhead repair
Weatherford products and services are subject to Weatherford’s standard terms and
1 of 9 conditions. For more information concerning the full line of Weatherford products and services,
please contact your authorized Weatherford representative. Unless noted otherwise,
trademarks and servicemarks noted herein are the property of Weatherford.
Weatherford products and services are subject to Weatherford’s standard terms and
2 of 9 conditions. For more information concerning the full line of Weatherford products and services,
please contact your authorized Weatherford representative. Unless noted otherwise,
trademarks and servicemarks noted herein are the property of Weatherford.
OPERATION
Normal well conditions will allow ample drill pipe to be run below the storm packer for proper weight and for proper
well circulation. If the drill pipe weight is less than 20,000 lb., drill collars should be run below the tool for weight.
MAKE-UP (Recommended)
After the storm packer has been set in the slips on its pick-up joint, make up the lower half of the storm valve, making
sure all breaks are tong tight and lock screws are secure. Hand make-up the top back-off sub on the drill pipe. Pick
up on joint or stand and stab into the mating parts. Hand rotate twenty (20) rounds to the right. Tighten drill pipe
connection holding back-ups on the top connector. Remove tongs and continue hand make-up of the back-off sub
and tighten as you would any safety joint. Check the left-hand break out several times, assuring proper torque.
CAUTION: DO NOT LIFT DRILL STRING UNTIL BACK-OUT THREADS ARE FULLY ENGAGED.
After reaching setting depth, rotate and set storm packer, set weight on packer. Maintain a neutral weight (0) and
rotate the back-out sub twelve (12) rounds to the left. At this point the valve is closed and threads are still engaged.
Pressure may now be applied to assure valve is operational. Test only to ½ the test pressure required to shear the
pump out plug. Release the pressure. An additional twelve (10) rounds will totally release from tool.
RE-CONNECT PROCEDURE
To re-connect drill pipe to storm valve, lower the drill pipe slowly and tag the top of the valve with a maximum of 1,000
lb. of weight on the valve. During re-connect, be prepared to handle any pressure from the drill pipe and casing side.
With 1,000 lb. of weight set on the valve, rotate five (5) rounds to the right and then pull 2,000-lb. tension on the tool
to assure the threads are engaged. Slack down to neutral weight (0) and rotate an additional five (5) rounds to the
right. At this point the valve is closed and in a position to pump out the pre-loaded plug. This procedure is
recommended if extended circulation periods at rates of 10 BPM or greater are needed. If the pump out plug is not to
be sheared, a total of twenty-two (22) rounds to the right should be applied. This will open the valve fully for
pumping. A maximum rate of nine (9) barrels per minute is recommended with the plug in place.
Weatherford products and services are subject to Weatherford’s standard terms and
3 of 9 conditions. For more information concerning the full line of Weatherford products and services,
please contact your authorized Weatherford representative. Unless noted otherwise,
trademarks and servicemarks noted herein are the property of Weatherford.
ASSEMBLY – 682-10
1. Place top sub (1) in vise. If a gage ring is required, install gage ring (2) onto top sub
(1) (LEFT HAND THREAD) and install set screws (3) in gage ring (2).
2. Install valve mandrel (10) into mandrel retainer (7). Install mandrel retainer (7) onto 1
top sub (1). Install set screws (6) in top sub (1).
3. Install o-ring (5) on top sub (1). Install upper body (4) onto top sub (1). Install o-ring
(9) on upper body (4). 2
4. Install valve (12) onto valve mandrel (10). 3
5. Install extension body (11) onto upper body (4) and install set screws (8) in extension LEFT
body (11). HAND
6. Install o-ring (20) in circulating body (19). Install plug (22) in circulating body (19) and THREAD
install shear screws (21) in circulating body (19).
7. Install o-rings (18) onto valve (12) Install circulating body (19) over valve (12) and into
extension body (11). Install set screws (16) in extension body (11).
8. Install o-ring (17) on circulating body (19). Install o-ring (14) on extension body (11).
4
9. Install lower body (15) onto extension body (11). Install set screws (13) into lower
body (15).
5
DISASSEMBLY – 682-10
6
1. Place top sub (1) in vise. Remove set screws (8) and (13). 7
2. Remove lower body (15) from extension body (11).
3. Remove shear screws (21) and remove plug (22). 8
4. Remove set screws (16) from circulating body (19).
5. Remove circulating body (19) from extension body (11). Remove o-rings (17 & 20).
6. Remove extension body (11) from upper body (4) and remove o-ring (14). 9
7. Remove valve (12) from valve mandrel (10) and remove o-rings (18). 10
8. Remove upper body (4) from top sub (1) and remove o-ring (9). 11
9. Remove set screws (6) and remove mandrel retainer (7) from top sub (1). 12
10. Remove valve mandrel (10) from top sub (1). 13
11. (Optional) Remove set screws (3) and remove gage ring (2) from top sub (1). LEFT 14
HAND THREAD. 15
12. Remove o-rings (5) from top sub (1).
16
13. Clean and inspect all parts. Replace all worn or damaged parts. 17
Weatherford products and services are subject to Weatherford’s standard terms and
4 of 9 conditions. For more information concerning the full line of Weatherford products and services,
please contact your authorized Weatherford representative. Unless noted otherwise,
trademarks and servicemarks noted herein are the property of Weatherford.
ASSEMBLY – 682-20
1. Place top sub (1) in vise. If a gage ring is required, install gage ring (2) onto top 1
sub (1). (LEFT HAND THREAD) and install set screws (3) in gage ring (2).
2. Install valve mandrel (11) into mandrel retainer (7). Install mandrel retainer (7)
onto top sub (1). Install set screws (6) in top sub (1).
2
3. Install o-rings (5) on top sub (1). Install upper body (4) onto top sub (1).
4. Install valve (12) onto valve mandrel (11). Install o-ring (10) onto upper body (4). 3
5. Install o-ring (14) in extension body (9) and install extension body (9) onto upper
body (4). Install set screws (8) in extension body (9). LEFT
HAND
6. Install o-ring (20) in circulating body (19). Install plug (23) in circulating body (19)
THREAD
and install shear pin (22) in circulating body (19) and plug (23). Install pipe plugs
(21) in circulating body (19).
7. Install o-rings (18) onto valve (12). Install circulating body (19) over valve (12)
and into extension body (9). Install set screws (16) in extension body (9).
8. Install o-ring (15) on extension body (9). 4
9. Install lower body (17) onto extension body (9) and install set screws (13) into
lower body (17).
DISASSEMBLY – 682-20
5
1. Place top sub (1) in vise. Remove set screws (8) and (13).
2. Remove lower body (17) from extension body (9). 6
7
3. Remove pipe plugs (21) and remove shear pin (22) from plug (23). Remove plug
(23) from lower circulating body (19).
8
4. Remove set screws (16) from circulating body (9).
5. Remove circulating body (19) from extension body (9). Remove o-ring (20). 9
6. Remove extension body (9) from upper body (4) and remove o-rings (14 & 15). 10
7. Remove valve (12) from valve mandrel (11) and remove o-rings (18).
11
8. Remove upper body (4) from top sub (1) and remove o-ring (10).
9. Remove set screws (6) and remove mandrel retainer (7) from top sub (1). 12
10. Remove valve mandrel (11) from top sub (1).
11. (Optional) Remove set screws (3) and remove gage ring (2) from top sub (1). 13
LEFT HAND THREAD. 14
12. Remove o-rings (5) from top sub (1).
15
13. Clean and inspect all parts. Replace all worn or damaged parts.
16
17
18
18
19
OPTIONAL SHEAR PINS 20
21
PART SHEAR 22
NUMBER (PSI) 23
682-20-910 (WHITE) 1500
682-20-900 (BLUE) 3000
682-20-901 (RED) 6000
Weatherford products and services are subject to Weatherford’s standard terms and
5 of 9 conditions. For more information concerning the full line of Weatherford products and services,
please contact your authorized Weatherford representative. Unless noted otherwise,
trademarks and servicemarks noted herein are the property of Weatherford.
DIMENSIONAL DATA F
DIMENSIONS (IN./mm) E
SIZE PRODUCT
(IN.) NUMBER A B C D E D
DIMENSIONS (IN./mm)
SIZE PRODUCT
(IN.) NUMBER F G H J K
C F
4.750 1.750 1.500 4.500 1.500
4-3/4 682-10 120,65 44,450 38,100 114,30 38,100
G
A H
J K
Weatherford products and services are subject to Weatherford’s standard terms and
6 of 9 conditions. For more information concerning the full line of Weatherford products and services,
please contact your authorized Weatherford representative. Unless noted otherwise,
trademarks and servicemarks noted herein are the property of Weatherford.
PARTS LIST
ITEM 4-3/4"
DESCRIPTION
NO 682-10-015
1
1 TOP SUB 682-10-620
2 GAGE RING (OPTIONAL) SEE CHART
3 SET SCREW (OPTIONAL) SEE CHART 2
4 UPPER BODY** 682-10-380 3
5 O-RING* 050-90-333 (2)
LEFT
6 SET SCREW * 003-C4-004 (3) HAND
7 MANDREL RETAINER 682-10-815 THREAD
8 SET SCREW* 5/8-11 x 1/2" 021-C10-008 (4)
9 O-RING* 050-90-235
10 VALVE MANDREL 682-10-315
11 EXTENSION BODY** 682-10-240
4
12 VALVE 682-10-665
13 SET SCREW* 5/8-11 x 1/2" 021-C10-008 (4)
14 O-RING* 050-90-342 5
15 LOWER BODY** 682-10-640
16 SET SCREW* 3/8-16 X 3/8" 003-C4-006 (3) 6
17 O-RING* 050-90-336 7
18 O-RING* 050-90-329 (4)
8
19 CIRCULATING BODY 682-10-235
20 O-RING* 050-90-325
21 SHEAR SCREW* 683 PSI/EA. B20-C4-006 (6)
9
22 PLUG* 682-10-915
*Common repair parts. 10
11
**These are mated parts and cannot be replaced separately without field
adaptation. 12
13
14
15
16
17
18
19
18
20
21
22
Weatherford products and services are subject to Weatherford’s standard terms and
7 of 9 conditions. For more information concerning the full line of Weatherford products and services,
please contact your authorized Weatherford representative. Unless noted otherwise,
trademarks and servicemarks noted herein are the property of Weatherford.
DIMENSIONAL DATA E
DIMENSIONS (IN./mm)
SIZE PRODUCT
D
(IN.) NUMBER A B C D
72.125 51.437 40.922 23.500
6-1/8 682-20
1831,97 1306,49 1039,41 596,90
DIMENSIONS (IN./mm)
SIZE PRODUCT
(IN.) NUMBER E F G H E
C
6.125 3.750 2.000 4.750
6-1/8 682-20
155,57 95,250 50,800 120,65 F
A
G
G
H
Weatherford products and services are subject to Weatherford’s standard terms and
8 of 9 conditions. For more information concerning the full line of Weatherford products and services,
please contact your authorized Weatherford representative. Unless noted otherwise,
trademarks and servicemarks noted herein are the property of Weatherford.
PARTS LIST
1
ITEM 6-1/8" 6-1/8"
DESCRIPTION
NO. 682-20-016 682-20-017
1 TOP SUB 682-20-610 682-20-611
2 GAGE RING (OPTIONAL) SEE CHART SEE CHART 2
3 SET SCREW (OPTIONAL) SEE CHART SEE CHART 3
4 UPPER BODY** 682-20-385 682-20-385
5 O-RING* 682-20-512 (2) 682-20-512 (2) LEFT
SET SCREW * 3/8-16 X 3/8" HAND
6 003-C6-006 (3) 003-C6-006 (3)
THREAD
7 MANDREL RETAINER 682-20-226 682-20-226
8 TORQUE SCREW* 021-C10-012 (4) 021-C10-012 (4)
9 EXTENSION BODY ** 682-20-390 682-20-390
10 O-RING* 050-90-347 050-90-347
11 VALVE MANDREL 682-20-210 682-20-210 4
12 VALVE 682-20-666 682-20-666
13 TORQUE SCREW* 021-C10-012 (4) 021-C10-012 (4)
14 O-RING* 050-90-338 050-90-338
15 O-RING* 050-90-347 050-90-347
5
16 SET SCREW* 3/8-16 X 3/8" 003-C4-006 (2) 003-C4-006 (2)
17 LOWER BODY** 682-20-620 682-20-621 6
18 O-RING* 050-90-332 (4) 050-90-332 (4) 7
19 CIRCULATING BODY 682-20-372 682-20-372
20 O-RING* 050-90-329 050-90-329 8
21 PIPE PLUG* 016-02-000 (2) 016-02-000 (2) 9
22 SHEAR PIN* 6,000 PSI 682-20-901 682-20-901 10
23 PLUG* 682-20-850 682-20-850
*Common repair parts. 11
**These are mated parts and cannot be replaced separately without field adaptation. 12
13
14
15
16
17
18
18
19
20
21
22
23
Weatherford products and services are subject to Weatherford’s standard terms and
9 of 9 conditions. For more information concerning the full line of Weatherford products and services,
please contact your authorized Weatherford representative. Unless noted otherwise,
trademarks and servicemarks noted herein are the property of Weatherford.