NO Features Setup Illustration
1 Single OverVoltage Alarm when Max single voltage over setting,buzzer alarm
2 Single Under voltage Alarm when Min single voltage under setting,buzzer alarm
3 Single Over Voltage protection when Max single voltage over setting,Stop charge
4 Single Under Voltage protectionwhen min single voltage under setting,Stop discharge
In Over voltage protection, when Max voltage under
5 Single Over Voltage recovery setting, Charge sart agin.
In under voltage protection, when Min under voltage
6 Single under voltage recovery over seting,discharge start again.
7 Total voltage over protection when total voltage over setting, stop charge
8 Total voltage under protection when total voltage under setting, stop discharge
when charge current over setting & over current delay
9 Charge over current protection time, stop charge
when charge current over setting & over current delay
10 Charge over current delay time, stop charge
when over current over setting & over current delay
11 Disharge over current protecti time, stop discharge
when over current over setting & over current delay
12 Discharge over current delay time, stop discharge
Any single voltage over setting, it will discharge
13 Balance limiting voltage balance
When charge, voltage will over the setting, it will start
14 Balance start voltage balance
When charge, max voltage distance have to over
15 Blance voltage distance setting, it maybe balance
16 Blance Current Balance current setting
Factory has been calibrated
17 System reference voltage
18 Current Meature According to the BMS current
current defaults to factory to 30A,do not revise
19 Power start current another
20 short cut protection current Over this current & short cut delay time
21 short cut delay time Over this current & short cut delay time
System without current and over this time, it into
standy , it will turn off bluetooth automatically. When
22 Automatically Standby time charge/discharge, system will recovery.
23 Totage voltage parameter to regular total voltage ,do not adjust
BMS real Series, if it test the series is not the same as
24 Battery real Series the setting, system will not start discharge.
25 Charge high temperature protecwhen battery temperature over setting, stop charge
when battery temperature under setting,system will
26 charge high temp recovery charge again
when battery temperature over setting, system stop
27 discharge high temp protection discharge
when battery temperature under setting, system
28 discharge high temp recovery discharge again
when MOS temperature over setting,stop
29 power high temp protection charge/disharge
when MOS temperatuer under setting,
30 Power high temp recovery charge/discharge recovery
31 Battery physical capacity battery standard capacity
can input any one, when battery full charge, system
32 battery residual capacity will adjust into your seted physical capacity
33 Total cyclic capacity Without setting
34 one circle length of tire tire run one circle distance for HALL testing
35 one circle pluse times motor run one circle ,Hall pluse times for Hall test
Series with Series connection resistance to make up
36 Connection Resistance n single voltage abnormal for signal wires too long
Notice 3.7V Ternary Setup 3.2V LiFePO4 Setup 2.4V LTO Set up
4.25V 3.65V 2.8V
3.1V 2.9V 1.9V
4.19V 3.6V 2.7V
3V 2.8V 1.8V
4.1V 3.4V 2.4V
3.15V 3V 2V
Single Max voltage x
Series 120V 120V 120V
Single Min Volage x Series 0V 0V 0V
50A 50A 50A
5S 5S 5S
200A 200A 200A
5S 5S 5S
4.2V 3.6V 2.7V
4.1V 3.4V 2.4V
0.002V 0.002V 0.002V
180MA 200MA 200MA
Between2.990-3.005has
calibrated, do not adjust. 2.990V-3.005V 2.990V-3.005V 2.990V-3.005V
100A/150A/200A/300A,
±10% for accurate
calibration of current According to your According to your According to your
values buying buying buying
Do not revise 20A 20A 20A
Setting is less than According to your According to your According to your
(Current meature*1.8) buying buying buying
300US 300US 300US
180S 180S 180S
Between(3300-3800)Do
not adjust 3300-3400 3300-3400 3300-3400
24S 24S 24S
60 degree 60degree 60degree
55degree 55degree 55degree
60degree 60degree 60degree
55degree 55degree 55degree
75degree 75degree 75degree
70degree 70degree 70degree
100AH 100AH 100AH
0AH 0AH 0AH
0AH 0AH 0AH
1000MM 1000MM 1000MM
23 23 23
0 0 0
序号 设置项目 说明
1 单体过压告警 当最高单体电压大于设定值后,蜂鸣器告警
2 单体欠压告警 当最低单体电压小于设定值后,蜂鸣器告警
当最高单体电压大于设定值后,关闭充电管,停
3 单体过压保护 止充电
当最低单体电压小于设定值后,关闭放电管,停
4 单体欠压保护 止放电
发生单体过压保护以后,当最高单体电压小于设
5 单体过压恢复 定值后,重新开启充电管
发生单体欠压保护以后,当最低单体电压大于设
6 单体欠压恢复 定值后,重新开启放电管
7 总压过压保护 当总电压大于设定值后,关闭充电管,停止充电
8 总压欠压保护 当总电压小于设定值后,关闭放电管,停止放电
当充电电流大于设定值,且大于设定值的时间大
9 充电过流保护 于充电过流延时,关闭充电管,停止充电
当充电电流大于设定值,且大于设定值的时间大
10 充电过流延时 于充电过流延时,关闭充电管,停止充电
当放电电流大于设定值,且大于设定值的时间大
11 放电过流保护 于放电过流延时,关闭放电管,停止放电
当放电电流大于设定值,且大于设定值的时间大
12 放电过流延时 于放电过流延时,关闭放电管,停止放电
不管任何情况下,任意单体电压一旦超过设定值
13 均衡极限电压 ,此单体就会进行放电均衡
充电的时候,单体电压必须要大于设定值,才有
14 均衡起控电压 可能会均衡
充电时候,单体之间的最大压差必须要大于设定
15 均衡单体压差 值,才有可能会均衡
16 均衡电流大小 设置均衡电流
系统测量单体电压的一个基准电压,也是校准单
17 系统基准电压 体电压的一个参数,出厂已校准
根据购买的选项,有不同的量程,表示系统能够
18 电流传感量程 测量的最大电流,同时又是校准电流的参数
此电流默认出厂设置为30A,不可以擅自设置成
19 功率启动电流 其他数值
20 短路保护电流 大于此电流且大于设定的延时时间会认为是短路
21 短路保护延时 大于此电流且大于设定的延时时间会认为是短路
系统没有电流后延迟此设定值后系统进入待机,
此时会自动关闭蓝牙,当有放电或者充电电流后
22 自动待机时间 ,系统会自动恢复
用于校准总电压的参数,出厂已经校准好,请不
23 总压调节参数 要调
保护板实际连接的电池串数,如果系统检测到的
串数不等于此设定值,系统不会开启放电,状态
24 电池实际串数 会显示“均衡线掉串”
当电池1234的温度大于设定值,系统会关闭充
25 充电高温保护 电管 停止充电
当电池1234的温度小于设定值,系统会重新打
26 充电高温恢复 开充电管
当电池1234的温度大于设定值,系统会关闭放
27 放电高温保护 电管 停止放电
当电池1234的温度小于设定值,系统会重新打
28 放电高温恢复 开放电管
当MOS管温度大于设定值,系统会关闭放电管和
29 功率高温保护 充电官
当MOS管温度小于设定值,系统会重新打开放电
30 功率高温恢复 管和充电管
你电池组的标称容量,设置以后库仑计才能准确
31 电池物理容量 工作
你电池组当前的剩余容量,可以随意预估一个设
置进去,当电池组充满电后,系统会自动调节到
32 电池剩余容量 你设置的电池物理容量
33 总共循环容量 电池组累计的放电容量,无需设置
34 轮胎一周长度 轮胎转一圈走的距离,用于校准霍尔测速
35 一周脉冲次数 电机转一圈霍尔脉冲次数,用于校准霍尔测速
电池串与串之间的连接内阻,用于补偿因连接导
36 连接内阻n 线太长导致的大电流时候单体电压不准
注意 默认三元配置参数 默认铁锂配置参数 默认钛酸锂配置参数
4.25V 3.65V 2.8V
3.1V 2.9V 1.9V
4.19V 3.6V 2.7V
3V 2.8V 1.8V
4.1V 3.4V 2.4V
3.15V 3V 2V
单体最高电压*电池串数 120V 120V 120V
单体最低电压*电池串数 0V 0V 0V
50A 50A 50A
5S 5S 5S
200A 200A 200A
5S 5S 5S
4.2V 3.6V 2.7V
4.1V 3.4V 2.4V
0.002V 0.002V 0.002V
180MA 200MA 200MA
默认值2.990-3.005之间,已校
准,请不要调节 2.990V-3.005V 2.990V-3.005V 2.990V-3.005V
有100A-150A-200A-300A,几个
量程,购买时候的选项应该和这
个值对应,大约可以上下浮动
10%用于精确校准电流值 根据购买而定 根据购买而定 根据购买而定
请不要调节此参数 20A 20A 20A
设置值要小于(电流传感器量程
*1.8) 根据购买而定 根据购买而定 根据购买而定
300US 300US 300US
180S 180S 180S
默认值约(3300-3800)之间,
校准总电压,出厂已校准 3300-3400 3300-3400 3300-3400
24串 24串 24串
60度 60度 60度
55度 55度 55度
60度 60度 60度
55度 55度 55度
75度 75度 75度
70度 70度 70度
100AH 100AH 100AH
0AH 0AH 0AH
0AH 0AH 0AH
1000MM 1000MM 1000MM
23 23 23
0 0 0