SDongleA-05 Quick Guide (WLAN-FE)
Document Issue: 05
Part Number: 31500BXP
Release Date: 2020-08-25
Copyright © Huawei Technologies Co., Ltd. 2020. All rights reserved.
The information in this document is subject to change without notice. Every
effort has been made in the preparation of this document to ensure accuracy
of the contents, but all statements, information, and recommendations in this
document do not constitute a warranty of any kind, express or implied. You
can download this document by scanning the QR code.
• SDongleA-05 (Dongle for short) is a smart communications expansion module that works
with Huawei inverters to implement communication between inverters and the
management system using WLAN or FE.
• A Dongle can be used for device cascading using RS485 communication (inverter cascaded
or inverters cascaded with other devices). A maximum of 10 devices can be cascaded.
• When multiple inverters are cascaded, only one Smart Dongle or one SmartLogger is
allowed.
Application Scenario of the SUN2000-(3KTL–20KTL)
As the Master Inverter
1 Communication Scenario
• Inverters with different appearances are used in the same communication scenario. The
inverters in this document are used as an example.
• In the communications scenario, ensure that the wireless network of the inverter and router
is not disturbed and that the signal is normal.
FusionSolar APP
Master
inverter
Management system
Router Number of devices in the
RS485 communication scenario
Limited Number Actual Number
Devices in the Maximum number Number of other
Slave Number of
dashed box are of devices that can devices (such as Smart
optional. slave
inverter 1 be connected to Power Sensor and
inverters
the Dongle energy storage devices)
10 N≤9 ≤9–N
Slave
In the RS485 cascading communication networking, the slave
inverter N inverter model can be SUN2000-(3KTL–20KTL)-M0,
SUN2000-50KTL/60KTL-M0, SUN2000-29.9KTL/36KTL,
SUN2000-33KTL-A.
2 Installation and Commissioning
1. Install the Dongle.
WLAN Communication
LED indicator
Inverter USB port
FE Communication
You are advised to use a CAT 5E outdoor shielded network cable (outer diameter < 9 mm;
internal resistance ≤ 1.5 Ω/10 m) and shielded RJ45 connectors.
Inverter USB port
LED
Operation Remarks Description
Color Status
The Dongle is not secured or is
N/A Off
not powered on.
Yellow
(blinking green The Dongle is secured and
Steady on
and red powered on.
Normal
simultaneously)
Blinking at short
intervals (on for The parameters for connecting
Red
0.2s and then off to the router are to be set.
for 0.2s)
Installing
the Dongle The Dongle is faulty. Replace the
Red Steady on
Dongle.
No communication with the
inverter
• Remove and insert the
Blinking at long Abnormal Dongle.
Blinking red
intervals (on for • Check whether inverters
and green
1s and then off match the Dongle.
alternatively
for 1s) • Connect the Dongle to other
inverters. Check whether the
Dongle or the USB port of the
inverter is faulty.
Before setting parameters, ensure that the AC and DC side of the inverter has been powered on.
2. Install the FusionSolar app (2.5.0 or later) and perform Setup Wizard. For details, see the
corresponding FusionSolar App Quick Guide. You can download the document by scanning
the Quick Guide QR code. If the operation has been performed, ignore it.
• Method 1: Search for
FusionSolar in Google Play
and install the app.
• Method 2: Scan the QR
code to download and
install the app.
FusionSolar Google Play Quick Guide
LED Indicator
Operation Remarks Description
Color Status
Blinking at long
intervals (on for 0.5s
Green Normal Connecting to the router
and then off for
Router 0.5s)
connection Failed to connect to the router.
settings Blinking at short
Check whether the parameters
intervals (on for 0.2s
Red Abnormal for connecting the Dongle to the
and then off for
router are properly set. If not, set
0.2s)
the parameters correctly.
Successfully connected to the
Green Steady on Normal
management system.
Failed to connect to the
management system. Check
Blinking at long whether the parameters for
Management Red intervals (on for 1s Abnormal connecting inverters to the
system and then off for 1s) management system are properly
settings set. If not, set the parameters
correctly.
Blinking at short
The inverter is communicating
intervals (on for 0.2s
Green Normal with the management system
and then off for
through the Dongle.
0.2s)
• In areas (such as the UK) where the FusionSolar app is not available, or
when a third-party management system is used, only the SUN2000 app
can be used for commissioning. This document uses the FusionSolar app
as an example to describe the commissioning method. For the SUN2000
app, perform operations as required.
• To obtain the SUN2000 App, scan the QR code or search for “SUN2000”
in Huawei AppGallery, download the latest installation package, and
install the SUN2000 app by following the instructions. The SUN2000 app
version should be 3.2.00.002 (Android) or later.
Performance Parameters
Model on the Nameplate SDongleA-05
Maximum Number of Devices 10 (Inverters are connected with each other over RS485.)
Network Port 10/100M Ethernet port
Encryption Mode Not encrypted, WPA, WPA2, WPA/WPA2
Installation Mode Plug-and-play (applicable to inverters only)
Indicator LED
Dimensions (W x H x D) 146 mm x 48 mm x 33 mm
Net Weight 90 g
Ingress Protection Rating IP65
Typical Power Consumption 2.5 W
802.11b, 802.11g, 802.11n
Standard and Frequency Band
2.412 GHz to 2.484 GHz
Operating Temperature –30ºC to +65ºC
Relative Humidity (Non-
5%–95% RH
condensing)
Storage Temperature –40ºC to +70ºC
Highest Altitude 4000 m